Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Braz J Otorhinolaryngol ; 90(1): 101336, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37839169

RESUMO

OBJECTIVE: The video otoscope has already proven to be useful for the diagnosis of several pathologies, so the objective of this study was to evaluate the diagnostic accuracy of the video otoscope in cases of tympanic membrane perforation. METHODS: This is a diagnostic accuracy study performed at the hearing health division of a tertiary-level referral hospital. Patients older than 8 years of age who had any symptom that could be related to perforation (otalgia, otorrhea, tinnitus, and/or hypoacusis) were invited to participate in the study. Participants were evaluated by three different diagnostic methods (otomicroscope, conventional otoscope, and video otoscope) performed by three different evaluators in a blind fashion. The microscope was considered the reference standard. RESULTS: 176 patients were evaluated, totaling 352 tympanic membranes. Twenty-seven tympanic membrane perforations were diagnosed by the microscope, a prevalence of 7.7%. The video otoscope showed a sensitivity of 85.2% (95% CI 81.5%‒88.9%), specificity of 98.1% (95% CI 96.7%‒99.5%) and accuracy of 97.1% (95% CI 95.4 %-98.8 %). The conventional otoscope showed a sensitivity of 96.3% (95% CI 94.3-98.3), specificity of 98.8% (95% CI 97.7-99.9) and accuracy of 98.6% (95% CI 97.4-99.8). The Kappa value between the microscope and the video otoscope was 0.8 and between the microscope and the conventional otoscope was 0.9. Regarding the participants' perception, 53.4% (p< 0.001) considered the video otoscope as the best method for understanding the tympanic membrane condition presented by them. CONCLUSIONS: The video otoscope showed relevant sensitivity and specificity for clinical practice in the diagnosis of tympanic membrane perforation. Moreover, this is an equipment that can facilitate the patient's understanding of the otologic pathology presented by him/her. In this regard, this method may be important for better patient compliance, requiring further studies to evaluate this hypothesis. LEVEL OF EVIDENCE: Is this diagnostic or monitoring test accurate? (Diagnosis)-Level 2 (Individual cross-sectional studies with consistently applied reference standard and blinding).


Assuntos
Perda Auditiva , Perfuração da Membrana Timpânica , Humanos , Masculino , Feminino , Perfuração da Membrana Timpânica/diagnóstico , Otoscópios , Estudos Transversais , Otoscopia/métodos , Membrana Timpânica
2.
Braz. j. otorhinolaryngol. (Impr.) ; Braz. j. otorhinolaryngol. (Impr.);90(1): 101336, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1534093

RESUMO

Abstract Objective The video otoscope has already proven to be useful for the diagnosis of several pathologies, so the objective of this study was to evaluate the diagnostic accuracy of the video otoscope in cases of tympanic membrane perforation. Methods This is a diagnostic accuracy study performed at the hearing health division of a tertiary-level referral hospital. Patients older than 8 years of age who had any symptom that could be related to perforation (otalgia, otorrhea, tinnitus, and/or hypoacusis) were invited to participate in the study. Participants were evaluated by three different diagnostic methods (otomicroscope, conventional otoscope, and video otoscope) performed by three different evaluators in a blind fashion. The microscope was considered the reference standard. Results 176 patients were evaluated, totaling 352 tympanic membranes. Twenty-seven tympanic membrane perforations were diagnosed by the microscope, a prevalence of 7.7%. The video otoscope showed a sensitivity of 85.2% (95% CI 81.5%‒88.9%), specificity of 98.1% (95% CI 96.7%‒99.5%) and accuracy of 97.1% (95% CI 95.4 %-98.8 %). The conventional otoscope showed a sensitivity of 96.3% (95% CI 94.3-98.3), specificity of 98.8% (95% CI 97.7-99.9) and accuracy of 98.6% (95% CI 97.4-99.8). The Kappa value between the microscope and the video otoscope was 0.8 and between the microscope and the conventional otoscope was 0.9. Regarding the participants' perception, 53.4% (p < 0.001) considered the video otoscope as the best method for understanding the tympanic membrane condition presented by them. Conclusions The video otoscope showed relevant sensitivity and specificity for clinical practice in the diagnosis of tympanic membrane perforation. Moreover, this is an equipment that can facilitate the patient's understanding of the otologic pathology presented by him/her. In this regard, this method may be important for better patient compliance, requiring further studies to evaluate this hypothesis. Level of evidence Is this diagnostic or monitoring test accurate? (Diagnosis)—Level 2 (Individual cross-sectional studies with consistently applied reference standard and blinding).

3.
Acta Otolaryngol ; 143(8): 699-703, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37603291

RESUMO

Background: Short array cochlear implant is indicated as rehabilitation in patients with severe to profound deafness, especially when there is cochlear ossification. In these cases, with reduced intracochlear patency, total insertion becomes more difficult, requiring the use of this type of electrode (15 mm). Few studies have been published to evaluate auditory performance, presenting controversial audiological results.Aims/Objectives: To report the speech perception of users of cochlear implants (CI) with short array. Material and Methods: A retrospective analysis of medical records of patients who underwent surgery for cochlear implantation with a short array, between 2009 and 2020, at the Hospital for Rehabilitation of Craniofacial Anomalies, University of São Paulo (HRAC-USP) was carried out. Results: There was performance evolution in the speech perception tests in the data analysis. Meningitis and congenital hearing loss were the main indications for CI in the sample. Conclusion. CI with a short array is an alternative in the management of patients with a history of cochlear ossification and severe or profound sensorineural hearing loss. Significance: To demonstrate the evolution of speech perception tests with short array cochlear implant in patients with or without ossified cochlea and its characteristics for application in clinical practice.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial , Percepção da Fala , Humanos , Osteogênese , Estudos Retrospectivos , Cóclea/cirurgia , Perda Auditiva Neurossensorial/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA