Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Bras Pneumol ; 35(9): 868-76, 2009 Sep.
Artigo em Inglês, Português | MEDLINE | ID: mdl-19820813

RESUMO

OBJECTIVE: To present a locally developed system of computer vision for use with HRCT images, designated SIStema para a Detecção e a quantificação de Enfisema Pulmonar (SISDEP, System to Detect and Quantify Pulmonary Emphysema), and to compare this system with a freeware system tool. METHODS: Thirty-three HRCT images scanned at the apex, hilum and base of the lungs of 11 patients with COPD were analyzed. The SISDEP was compared with the Osiris Medical Imaging Software Program regarding lung parenchyma segmentation, precision of the measurement of the cross-sectional area of the lungs in mm(2), mean lung density (MLD), relative area (RA) of the lung occupied by voxels with attenuation values < -950 hounsfield units (RA -950), 15th percentile point (Perc15) and visualization of hyperinflated areas using a color mask. RESULTS: Although both computational systems were efficient in segmenting the lungs, the SISDEP performed this task automatically and more rapidly. There were significant correlations between the two systems in terms of the results obtained for lung cross-sectional area, MLD, RA -950 and Perc15 (r(2) = 0.99, 0.99, 0.99 and 1.00, respectively). The color mask tool of the SISDEP allowed excellent visualization of hyperinflated areas, discriminating them from normal areas. CONCLUSIONS: The SISDEP was efficient in segmenting the lungs and quantifying lung hyperinflation, presenting an excellent correlation with the Osiris system. The SISDEP constitutes a promising computational tool for diagnosing and assessing the progression of emphysema in HRCT images of COPD patients.


Assuntos
Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Enfisema Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Máscaras , Pessoa de Meia-Idade , Estudos Prospectivos , Software/classificação , Software/normas , Estatísticas não Paramétricas
2.
J. bras. pneumol ; J. bras. pneumol;35(9): 868-876, set. 2009. ilus
Artigo em Português | LILACS | ID: lil-528392

RESUMO

OBJETIVO: Apresentar um sistema de visão computacional em imagens de TCAR, desenvolvido localmente e denominado SIStema para a Detecção e a quantificação de Enfisema Pulmonar (SISDEP). Comparar esse sistema a um sistema computacional de acesso livre. MÉTODOS: Foram utilizadas 33 imagens de TCAR de 11 pacientes com DPOC com cortes tomográficos em ápice, hilo e base. O SISDEP foi comparado a Osiris Medical Imaging Software Program quanto à segmentação do parênquima pulmonar; precisão das medidas da área de secção transversal dos pulmões em mm², densidade pulmonar média (DPM), porcentagem da relative area (RA, área relativa) dos voxels com densidade < -950 unidades hounsfield (ra -950), valores de 15º percentil de baixa atenuação (perc15) e visualização das áreas hiperaeradas por máscara colorida. RESULTADOS: Os dois sistemas realizaram uma segmentação pulmonar eficiente; porém o SISDEP o fez de modo automático e mais rápido. Na comparação das medidas de área de secção dos pulmões, DPM, Perc15 e RA -950, houve alta correlação (r² = 0,99; 0,99; 0,99; e 1,00, respectivamente) entre os dois sistemas. A ferramenta de máscara colorida do SISDEP permitiu excelente visualização das áreas hiperaeradas, discriminado-as das áreas normais. CONCLUSÕES: O SISDEP se mostrou eficiente na segmentação dos pulmões e na extração de dados quantitativos da aeração pulmonar com excelente correlação com o sistema Osiris. O SISDEP constitui uma promissora ferramenta computacional para a avaliação diagnóstica e o acompanhamento da evolução do enfisema em imagens de TCAR de pacientes com DPOC.


OBJECTIVE: To present a locally developed system of computer vision for use with HRCT images, designated SIStema para a Detecção e a quantificação de Enfisema Pulmonar (SISDEP, System to Detect and Quantify Pulmonary Emphysema), and to compare this system with a freeware system tool. METHODS: Thirty-three HRCT images scanned at the apex, hilum and base of the lungs of 11 patients with COPD were analyzed. The SISDEP was compared with the Osiris Medical Imaging Software Program regarding lung parenchyma segmentation, precision of the measurement of the cross-sectional area of the lungs in mm², mean lung density (MLD), relative area (RA) of the lung occupied by voxels with attenuation values < -950 hounsfield units (ra -950), 15th percentile point (perc15) and visualization of hyperinflated areas using a color mask. RESULTS: Although both computational systems were efficient in segmenting the lungs, the SISDEP performed this task automatically and more rapidly. There were significant correlations between the two systems in terms of the results obtained for lung cross-sectional area, MLD, RA -950 and Perc15 (r² = 0.99, 0.99, 0.99 and 1.00, respectively). The color mask tool of the SISDEP allowed excellent visualization of hyperinflated areas, discriminating them from normal areas. CONCLUSIONS: The SISDEP was efficient in segmenting the lungs and quantifying lung hyperinflation, presenting an excellent correlation with the Osiris system. The SISDEP constitutes a promising computational tool for diagnosing and assessing the progression of emphysema in HRCT images of COPD patients.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Tomografia Computadorizada por Raios X/métodos , Pulmão , Máscaras , Estudos Prospectivos , Estatísticas não Paramétricas , Software/classificação , Software/normas
3.
J Bras Pneumol ; 35(2): 164-73, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19287920

RESUMO

OBJECTIVE: Failure of noninvasive ventilation (NIV) has been associated with short-term adverse effects related to the use of masks. The aim of this study was to compare the incidence, type and intensity of adverse effects, as well as the comfort, of total face masks (TFMs), facial masks (FMs) and nasal masks (NMs) during NIV. METHODS: This was a randomized crossover trial involving 24 healthy volunteers submitted to six sessions of NIV in bilevel positive airway pressure mode using the TFM, FM and NM masks at low and moderate-to-high pressure levels. A written questionnaire was applied in order to evaluate eleven specific adverse effects related to the use of the masks. Comfort was assessed using a visual analog scale. The CO2 exhaled into the ventilator circuit was measured between the mask and the exhalation port. RESULTS: The performance of the TFM was similar to that of the NM and FM in terms of comfort scores. Higher pressure levels reduced comfort and increased adverse effects, regardless of the mask type. When the TFM was used, there were fewer air leaks and less pain at the nose bridge, although there was greater oronasal dryness and claustrophobia. Air leaks were most pronounced when the FM was used. The partial pressure of exhaled CO2 entering the ventilator circuit was zero for the TFM. CONCLUSIONS: The short-term adverse effects caused by NIV interfaces are related to mask type and pressure settings. The TFM is a reliable alternative to the NM and FM. Rebreathing of CO2 from the circuit is less likely to occur when a TFM is used.


Assuntos
Máscaras/efeitos adversos , Respiração com Pressão Positiva/instrumentação , Insuficiência Respiratória/terapia , Doença Aguda , Adolescente , Adulto , Análise de Variância , Estudos Cross-Over , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Máscaras/normas , Fatores de Tempo , Adulto Jovem
4.
J. bras. pneumol ; J. bras. pneumol;35(2): 164-173, fev. 2009. ilus, tab, graf
Artigo em Inglês, Português | LILACS | ID: lil-507333

RESUMO

OBJECTIVE: Failure of noninvasive ventilation (NIV) has been associated with short-term adverse effects related to the use of masks. The aim of this study was to compare the incidence, type and intensity of adverse effects, as well as the comfort, of total face masks (TFMs), facial masks (FMs) and nasal masks (NMs) during NIV. METHODS: This was a randomized crossover trial involving 24 healthy volunteers submitted to six sessions of NIV in bilevel positive airway pressure mode using the TFM, FM and NM masks at low and moderate-to-high pressure levels. A written questionnaire was applied in order to evaluate eleven specific adverse effects related to the use of the masks. Comfort was assessed using a visual analog scale. The CO2 exhaled into the ventilator circuit was measured between the mask and the exhalation port. RESULTS: The performance of the TFM was similar to that of the NM and FM in terms of comfort scores. Higher pressure levels reduced comfort and increased adverse effects, regardless of the mask type. When the TFM was used, there were fewer air leaks and less pain at the nose bridge, although there was greater oronasal dryness and claustrophobia. Air leaks were most pronounced when the FM was used. The partial pressure of exhaled CO2 entering the ventilator circuit was zero for the TFM. CONCLUSIONS: The short-term adverse effects caused by NIV interfaces are related to mask type and pressure settings. The TFM is a reliable alternative to the NM and FM. Rebreathing of CO2 from the circuit is less likely to occur when a TFM is used.


OBJETIVO: Falhas da ventilação não-invasiva (VNI) têm sido relacionadas a efeitos adversos agudos do uso de máscaras. O objetivo deste estudo foi comparar a incidência, tipo e intensidade de eventos adversos e conforto das máscaras facial total (MFT), facial (MF) e nasal (MN). MÉTODOS: Estudo randomizado, tipo cruzado, em 24 voluntários sadios submetidos a seis períodos de VNI, modo bilevel positive airway pressure em ajustes de baixa e moderada a alta pressão. Foi aplicado um questionário de avaliação de onze eventos adversos especificamente relacionados ao uso das máscaras. O conforto foi avaliado por escala visual analógica. O CO2 exalado no circuito foi medido entre a conexão da máscara e o orifício de exalação. RESULTADOS: A MFT teve desempenho similar a MF e MN quanto a escores de conforto. A aplicação de pressões mais altas reduziu o conforto e aumentou a incidência e a intensidade dos eventos adversos, independentemente do tipo de máscara. A MFT teve melhor desempenho quanto a vazamentos e dor no nariz e pior resultado quanto ao ressecamento oronasal e claustrofobia. A MF teve o pior resultado quanto a vazamentos. A pressão parcial do CO2 exalado no circuito permaneceu em zero com a MFT. CONCLUSÕES: Os eventos adversos agudos causados pelas interfaces de VNI são relacionados ao tipo de máscara e aos parâmetros de pressão. A MFT é uma alternativa confiável às MF e MN. A reinalação de CO2 a partir do circuito é menos provável de ocorrer com a MFT.


Assuntos
Adolescente , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Máscaras/efeitos adversos , Respiração com Pressão Positiva/instrumentação , Insuficiência Respiratória/terapia , Doença Aguda , Análise de Variância , Estudos Cross-Over , Análise de Falha de Equipamento , Máscaras/normas , Fatores de Tempo , Adulto Jovem
5.
J. vasc. bras ; 3(3): 273-276, set. 2004. ilus
Artigo em Português | LILACS | ID: lil-404085

RESUMO

Os autores relatam o caso de uma jovem de 23 anos com a forma completa da síndrome de unha-patela, uma desordem rara, herdada de natureza autossômica dominante. Além dos achados clássicos da síndrome, essa paciente apresentava sinais de hipertensão portal, manifestada por uma volumosa ascite, com circulação colateral exuberante observada em toda parede abdominal e torácica, e varizes de esôfago, sem evidências de hepatopatia associada. Curiosamente, sua tomografia computadorizada do abdome demonstrou ausência completa de veia cava inferior, confirmada pela venografia. Este é o primeiro caso descrito na literatura de associação de agenesia de veia cava inferior com a síndrome de unha-patela.


Assuntos
Humanos , Feminino , Adulto , Hipertensão Portal/diagnóstico , Veia Cava Inferior/patologia , Ascite/diagnóstico , Ascite Quilosa/diagnóstico
6.
J. bras. pneumol ; J. bras. pneumol;30(3): 270-273, maio-jun. 2004. ilus
Artigo em Português | LILACS | ID: lil-392968

RESUMO

A histoplasmose é uma doença fúngica causada pela inalação de esporos de Histoplasma capsulatum. A maioria dos indivíduos normais não apresenta doença após pequena inalação, porém exposições mais prolongadas podem levar ao desenvolvimento de infecção pulmonar aguda, crônica ou disseminada. Nos pacientes imunocomprometidos a infecção é disseminada e grave. Relatamos o caso de um paciente de treze anos, imunocompetente, com febre, tosse seca e dispnéia progressiva havia dois meses. O radiograma e a tomografia computadorizada de tórax evidenciavam infiltrado intersticial com micronódulos difusos. O paciente relatava contato intenso com pássaros em sua residência. Foi submetido a biópsia pulmonar a céu aberto, que evidenciou Histoplasma capsulatum em tecido pulmonar. A cultura do fragmento da biópsia confirmou a presença de Histoplasma capsulatum sp. O paciente foi tratado com anfotericina-B por 28 dias, seguida de itraconazol por seis meses, com resolução do quadro.


Assuntos
Humanos , Masculino , Adolescente , Anfotericina B , Antifúngicos , Histoplasma , Histoplasmose , Hospedeiro Imunocomprometido , Doença Aguda , Biópsia , Histoplasmose , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA