J Biomater Appl ; 35(3): 353-370, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32571172

RESUMO

Ti6Al4V used in biomedical applications still has several surface-related problems, such as poor bone compatibility and low wear resistance. In this work, the formation of a protective layer of titanium nitride obtained by plasma treatment in hollow cathode was studied, and the best experimental conditions were verified by a statistical factorial design of experiments. The samples were characterized in terms of their physical and chemical properties, correlating the effects of time (min) and temperature (°C). An achieved ideal condition was further analysed in terms of in vitro cytotoxicity, micro-abrasion, and electrochemical properties. The carried-out assessment has shown that nitrided condition has an improvement in wettability, microhardness, along with TixNy formation and roughness increment, when compared to pristine condition.


Assuntos
Ligas/química , Materiais Revestidos Biocompatíveis/química , Gases em Plasma/química , Titânio/química , Animais , Sobrevivência Celular , Corrosão , Técnicas Eletroquímicas , Eletrodos , Humanos , Camundongos , Propriedades de Superfície , Temperatura , Fatores de Tempo , Molhabilidade