1.
Sensors (Basel) ; 21(4)2021 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-33669964

RESUMO

A low-cost signal processing circuit developed to measure and drive a heat dissipation soil matric potential sensor based on a single thermosensitive resistor is demonstrated. The SnSe2 has a high thermal coefficient, from -2.4Ω/°C in the 20 to 25 °C to -1.07Ω/°C in the 20 to 25 °C. The SnSe2 thermosensitive resistor is encapsulated with a porous gypsum block and is used as both the heating and temperature sensing element. To control the power dissipated on the thermosensitive resistor and keep it constant during the heat pulse, a mixed analogue/digital circuit is used. The developed control circuit is able to maintain the dissipated power at 327.98±0.3% mW when the resistor changes from 94.96Ω to 86.23Ω. When the gravimetric water content of the porous block changes from dry to saturated (θw=36.7%), we measured a variation of 4.77Ω in the thermosensitive resistor, which results in an end-point sensitivity of 130 mΩ/%. The developed system can easily meet the standard requirement of measuring the gravimetric soil water content with a resolution of approximately Δθw=1%, since the resistance is measured with a resolution of approximately µ31µΩ, three orders of magnitude smaller than the sensitivity.