Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Arq. bras. med. vet. zootec. (Online) ; 75(5): 993-1004, Sept.-Oct. 2023. tab
Artigo em Inglês | LILACS-Express | VETINDEX | ID: biblio-1513662

RESUMO

ABSTRACT Feed additives, such as β-glucans, nucleotides, ascorbic acid (vitamin C), and α-tocopherol (vitamin E) can improve fish immunity and contribute to enhanced zootechnical performance of the fish. This study aimed to evaluate the effect of different concentrations of vitamin- mineral premix with or without the inclusion of an immunostimulant boost (β-glucans, nucleotides and vitamins C and E) on the zootechnical performance, hemato-immunological parameters, histological changes, and survival of Nile tilapia juveniles. To this end, isocaloric and isoproteic diets were prepared with three different concentrations of vitamin-mineral premix (1.0, 1.5, and 2.0 kg ton-1); additionally, the effects of 4% immunostimulant boost in the diet were examined considering six diets (without the immunostimulant boost: 0.1%, 0.15%, and 0.2%, and with the immunostimulant boost: 0.1% I, 0.15% I, and 0.2% I). We used 24 experimental units, each including 15 fish. Nile tilapia juveniles (1.88 g±0.25) were fed for 50 d with supplemented diets. Further, zootechnical indexes; histological changes in the liver, spleen, and intestine; intestinal morphology; and hemato-immunological parameters were evaluated. The fish that received supplementation showed higher zootechnical values, compared to those that did not receive the supplementation of immunostimulant reinforcement. Weight gain (30.45g±3.06), daily weight gain (0.60g±0.06), final weight (32.41g±3.15) and feed conversion (0.95±0.06) were higher in tilapia fed with an inclusion concentration of 0.2%. Hematological parameters were not affected by either the pre-mix concentrations or the booster of the immunostimulant. There was an increase in the number of intestinal folds, length of the fold, total area and number of goblet cells in the group supplemented with immunostimulant reinforcement. Supplementation with the immunostimulant promoted growth and improved intestinal morphology and immunological parameters of Nile tilapia juveniles.


RESUMO Os aditivos alimentares, tais como β-glucanos, nucleotídeos, ácido ascórbico (vitamina C) e α-tocoferol (vitamina E), podem melhorar a imunidade dos peixes e contribuir para um melhor desempenho zootécnico. Este estudo teve como objetivo avaliar o efeito de diferentes concentrações de premix vitamínico mineral com ou sem a inclusão de um imunoestimulante (β-glucanos, nucleotídeos e vitaminas C e E) no desempenho zootécnico, nos parâmetros hematoimunológicos, nas alterações histológicas e na sobrevivência dos juvenis de tilápia-do-Nilo. Para esse fim, foram preparadas dietas isocalóricas e isoproteicas com três concentrações diferentes de premix vitamínico e mineral (1,0, 1,5, e 2,0kg ton-1); além disso, foram examinados os efeitos da inclusão de 4% de imunoestimulante na dieta, considerando-se seis dietas (sem o imunoestimulante: 0,1%, 0,15% e 0,2%, e com a inclusão de imunoestimulante: 0,1% I, 0,15% I e 0,2% I). Foram utilizadas 24 unidades experimentais, cada uma com 15 peixes. Os juvenis de tilápia-do-Nilo (1,88g±0,25) foram alimentados, durante 50 dias, com as dietas suplementadas. Além disso, foram avaliados índices zootécnicos; alterações histológicas no fígado, baço e intestino; morfologia intestinal; e parâmetros hematoimunológicos. Os peixes que receberam suplementação apresentaram valores zootécnicos mais elevados, em comparação aos que não receberam a suplementação de reforço imunoestimulante. O ganho de peso (30,45g±3,06), o ganho de peso diário (0,60g ± 0,06), o peso final (32,41g±3,15) e a conversão alimentar (0,95±0,06) foram maiores nas tilápias alimentadas com uma concentração de inclusão de 0,2%. Os parâmetros hematológicos não foram afetados nem pelas concentrações de premix nem pelo reforço do imunoestimulante. Foi observado o aumento no número de pregas intestinais, no comprimento da prega, na área total e no número de células caliciformes no grupo suplementado com o boost imunoestimulante. A suplementação com o imunoestimulante promoveu o crescimento e melhorou a morfologia intestinal e os parâmetros imunológicos de juvenis de tilápia-do-Nilo.

2.
J Biomed Mater Res A ; 103(6): 2176-85, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25231734

RESUMO

Nanostructured materials have been widely studied concerning their potential biomedical applications, primarily to selectively carry specific drugs or molecules within a tissue or organ. In this context, boron nitride nanotubes (BNNTs) have generated considerable interest in the scientific community because of their unique properties, presenting good chemical inertness and high thermal stability. Among the many applications proposed for BNNTs in the biomedical field in recent years, the most important include their use as biosensors, nanovectors for the delivery of proteins, drugs, and genes. In the present study, BNNTs were synthesized, purified, and functionalized with glycol chitosan through a chemical process, yielding the BNNT-GC. The size of BNNT-GC was reduced using an ultrasound probe. Two samples with different sizes were selected for in vitro assays. The nanostructures were characterized by transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FTIR), thermal analysis (TGA), and dynamic light scattering (DLS). The in vitro assays MTT and neutral red (NR) were performed with NIH-3T3 and A549 cell lines and demonstrated that this material is not cytotoxic. Furthermore, the BNNT-GC was applied in gene transfection of plasmid pIRES containing a gene region that express a green fluorescent protein (GFP) in NIH-3T3 and A549 cell lines. The gene transfection was characterized by fluorescent protein produced in the cells and pictured by fluorescent microscopy. Our results suggest that BNNT-GC has moderate stability and presents great potential as a gene carrier agent in nonviral-based therapy, with low cytotoxicity and good transfection efficiency.


Assuntos
Compostos de Boro/farmacologia , Quitosana/farmacologia , Células Eucarióticas/metabolismo , Nanotubos/química , Transfecção/métodos , Animais , Morte Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Difusão Dinâmica da Luz , Células Eucarióticas/efeitos dos fármacos , Humanos , Camundongos , Células NIH 3T3 , Nanotubos/ultraestrutura , Plasmídeos/metabolismo , Espectroscopia de Infravermelho com Transformada de Fourier , Eletricidade Estática , Termogravimetria
3.
Arq. bras. med. vet. zootec ; 62(3): 570-577, jun. 2010. graf
Artigo em Português | VETINDEX | ID: vti-5847

RESUMO

Avaliaram-se as células endoteliais, a espessura corneana e a pressão intraocular (PIO) de cães portadores de catarata madura, empregando-se viscoelástico à base de hialuronato de sódio 3 por cento e sulfato de condroitina 4 por cento e hidroxipropilmetilcelulose 2 por cento, utilizando-se 20 cães, distribuídos entre os dois grupos dos viscoelásticos. A técnica cirúrgica adotada foi a da facoemulsificação bimanual. As avaliações tonométricas foram efetuadas antes e após o ato cirúrgico, aos 1, 7, 14, 21, 28 e 60 dias de pós-operatório, e a microscopia especular, antes e após 7, 28 e 60 dias. Não houve diferença estatística entre os grupos quanto à PIO, com exceção aos 14 dias, em que se observou maior PIO com o uso de hialuronato de sódio 3 por cento e sulfato de condroitina 4 por cento. Não houve diferença entre os grupos quanto aos parâmetros relacionados ao endotélio, com diminuição discreta da densidade celular endotelial e aumento da área celular com a utilização de hidroxipropilmetilcelulose 2 por cento. A utilização de ambos os dispositivos viscoelásticos analisados é recomendada para o procedimento de facoemulsificação em cães.(AU)


The endothelial cells, the corneal thickness, and the intraocular pressure (IOP) were evaluated in dogs with cataract, using viscoelastic substances based on 3 percent sodium hyaluronate and 4 percent chondroitin sulfate and comparing them with 2 percent hydroxypropylmethylcellulose. Twenty dogs were distributed in two groups of ten, each using one viscoelastic material. The surgical technique was bimanual phacoemulsification. The tonometric evaluations were made before and at one, seven, 14, 21, 28, and 60 days after the surgery and the specular microscopy before and after seven, 28, and 60 days. No statistical difference between groups was found according to IOP, except at 14 days, which was significantly higher with the use of 3 percent sodium hyaluronate and 4 percent chondroitin sulfate. There was no statistical difference between the groups considering the parameters related to the endothelium, with slight decrease in endothelial cell density and increase of cell area with the use of 2 percent hydroxypropylmethylcellulose. The use of both viscoelastic devices is recommended for the phacoemulsification in dogs.(AU)


Assuntos
Animais , Cães , Extração de Catarata , Facoemulsificação , Polímeros/uso terapêutico , Catarata/veterinária
4.
Arq. bras. med. vet. zootec ; Arq. bras. med. vet. zootec. (Online);62(3): 570-577, June 2010. graf
Artigo em Português | LILACS | ID: lil-554925

RESUMO

Avaliaram-se as células endoteliais, a espessura corneana e a pressão intraocular (PIO) de cães portadores de catarata madura, empregando-se viscoelástico à base de hialuronato de sódio 3 por cento e sulfato de condroitina 4 por cento e hidroxipropilmetilcelulose 2 por cento, utilizando-se 20 cães, distribuídos entre os dois grupos dos viscoelásticos. A técnica cirúrgica adotada foi a da facoemulsificação bimanual. As avaliações tonométricas foram efetuadas antes e após o ato cirúrgico, aos 1, 7, 14, 21, 28 e 60 dias de pós-operatório, e a microscopia especular, antes e após 7, 28 e 60 dias. Não houve diferença estatística entre os grupos quanto à PIO, com exceção aos 14 dias, em que se observou maior PIO com o uso de hialuronato de sódio 3 por cento e sulfato de condroitina 4 por cento. Não houve diferença entre os grupos quanto aos parâmetros relacionados ao endotélio, com diminuição discreta da densidade celular endotelial e aumento da área celular com a utilização de hidroxipropilmetilcelulose 2 por cento. A utilização de ambos os dispositivos viscoelásticos analisados é recomendada para o procedimento de facoemulsificação em cães.


The endothelial cells, the corneal thickness, and the intraocular pressure (IOP) were evaluated in dogs with cataract, using viscoelastic substances based on 3 percent sodium hyaluronate and 4 percent chondroitin sulfate and comparing them with 2 percent hydroxypropylmethylcellulose. Twenty dogs were distributed in two groups of ten, each using one viscoelastic material. The surgical technique was bimanual phacoemulsification. The tonometric evaluations were made before and at one, seven, 14, 21, 28, and 60 days after the surgery and the specular microscopy before and after seven, 28, and 60 days. No statistical difference between groups was found according to IOP, except at 14 days, which was significantly higher with the use of 3 percent sodium hyaluronate and 4 percent chondroitin sulfate. There was no statistical difference between the groups considering the parameters related to the endothelium, with slight decrease in endothelial cell density and increase of cell area with the use of 2 percent hydroxypropylmethylcellulose. The use of both viscoelastic devices is recommended for the phacoemulsification in dogs.


Assuntos
Animais , Cães , Extração de Catarata , Facoemulsificação , Polímeros/uso terapêutico , Catarata/veterinária
5.
Vet Rec ; 164(12): 359-63, 2009 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-19305006

RESUMO

Eighty-four female cats undergoing ovariohysterectomy in a blinded, randomised, prospective clinical study were assigned to one of three groups of 28 to receive either 0.01 mg/kg buprenorphine (group B), 4 mg/kg carprofen (group C), or the same doses of both drugs (group BC). A dynamic and interactive visual analogue scale (DIVAS) from 0 to 100 mm, and a simple descriptive scale (SDS) from 0 to 4 were used to evaluate the cats' degree of analgesia and sedation for 24 hours postoperatively. There was no significant difference in the cats' sedation scores by SDS or DIVAS, and no difference in their pain scores by DIVAS. By SDS, the cats in group BC had significantly lower pain scores than the cats in group C (P<0.001) and group B (P<0.05). Nine of the cats in group B, nine in group C and five in group BC required rescue analgesia, and the cats in group C required rescue earlier than those in group B (P<0.05).


Assuntos
Analgésicos Opioides/administração & dosagem , Anti-Inflamatórios não Esteroides/administração & dosagem , Buprenorfina/administração & dosagem , Carbazóis/administração & dosagem , Gatos , Dor Pós-Operatória/veterinária , Anestesia Geral/veterinária , Animais , Comportamento Animal/efeitos dos fármacos , Gatos/fisiologia , Gatos/cirurgia , Quimioterapia Combinada , Feminino , Histerectomia/métodos , Histerectomia/veterinária , Ovariectomia/métodos , Ovariectomia/veterinária , Medição da Dor/veterinária , Dor Pós-Operatória/tratamento farmacológico , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
6.
Ars vet ; 25(2): 058-062, 2009.
Artigo em Português | VETINDEX | ID: vti-765122

RESUMO

A caudectomia é realizada em algumas raças de cães visando prevenir traumas, além de uma questão de estética. O objetivo deste estudo foi avaliar os efeitos comportamentais, endócrinos, neurológicos e respiratórios produzidos pela caudectomia em cães recém-nascidos. Foram utilizados cinqüenta e dois filhotes de dois a sete dias de idade. A anestesia epidural sacrococígea foi realizada utilizando uma agulha 27 G x ½`` e seringa de insulina com 0,2 mL de lidocaína 0,5% com adrenalina. A caudectomia foi realizada em metade dos filhotes de cada fêmea e a outra metade foi utilizada como controle. A concentração de cortisol plasmático, ganho de peso, freqüência respiratória, vocalização, defecação, micção, movimentação, e reflexos anogenital, de sucção, magnum, flexor, vestibular e tátil foram avaliados antes e 1, 2, 3, 4, 8 e 24 horas após a caudectomia. Os resultados foram comparados utilizando ANOVA, seguidos de Student Newman Keuls, Friedman or Mann-Whitney tests. Não houve diferença em tempo ou entre os grupos em nenhuma variável. A caudectomia realizada após anestesia epidural não alterou frequência respiratória, comportamento, reflexos neurológicos e concentração de cortisol plasmático até 24 horas após a cirurgia. Deve ser considerado que a anestesia epidural pode ter mascarado um efeito prejudicial da caudectomia nestas variáveis.PALAVRAS-CHAVE: Anestesia epidural. Cães.Caud

7.
Ars vet ; 25(2): 58-62, 2009. tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1451898

RESUMO

Tail docking is performed in some dog breeds to prevent injuries and to improve appearance. It has been forbidden in some countries for ethical reasons. The aim of this study was to investigate the behavioural, endocrine, neurological and respiratory effects produced by tail docking in newborn dogs. Fifty-two puppies ranging from 2 to 7 days of age were used. Sacrococcigeal epidural anaesthesia was performed using a 27 G x ½" needle and an insulin syringe filled with 0.2 mL of 0.5% lignocaine with adrenaline. Tail docking was performed in half of the puppies of each litter and the other half were used as controls. Plasma cortisol concentration, weight gain, respiratory rate, vocalization, defecation, urination, movement and suction, anogenital, magnum, flexor, vestibular and tactile reflexes were investigated both before and 1, 2, 3, 4, 8 and 24 hours after tail docking. Data were compared using ANOVA, followed by Student Newman Keuls, Friedman or Mann-Whitney tests where applicable. Tail docking after epidural anaesthesia did not modify respiratory rate, behaviour, neurological reflexes or plasma cortisol concentration up to 24 hours after surgery. It should be considered that epidural anaesthesia might have masked a possible harmful effect of tail docking on these variables.


A caudectomia é realizada em algumas raças de cães visando prevenir traumas, além de uma questão de estética. O objetivo deste estudo foi avaliar os efeitos comportamentais, endócrinos, neurológicos e respiratórios produzidos pela caudectomia em cães recém-nascidos. Foram utilizados cinqüenta e dois filhotes de dois a sete dias de idade. A anestesia epidural sacrococígea foi realizada utilizando uma agulha 27 G x ½e seringa de insulina com 0.2 mL de lidocaína 0,5% com adrenalina. A caudectomia foi realizada em metade dos filhotes de cada fêmea e a outra metade foi utilizada como controle. A concentração de cortisol plasmático, ganho de peso, freqüência respiratória, vocalização, defecação, micção, movimentação, e reflexos anogenital, de sucção, magnum, flexor, vestibular e tátil foram avaliados antes e 1, 2, 3, 4, 8 e 24 horas após a caudectomia. Os resultados foram comparados utilizando ANOVA, seguidos de Student Newman Keuls, Friedman or Mann-Whitney tests. Não houve diferença em tempo ou entre os grupos em nenhuma variável. A caudectomia realizada após anestesia epidural não alterou frequência respiratória, comportamento, reflexos neurológicos e concentração de cortisol plasmático até 24 horas após a cirurgia. Deve ser considerado que a anestesia epidural pode ter mascarado um efeito prejudicial da caudectomia nestas variáveis.


Assuntos
Animais , Recém-Nascido , Cães , Cauda/cirurgia , Hidrocortisona/administração & dosagem , Anestesia Caudal/veterinária , Lidocaína/administração & dosagem , Doenças do Sistema Nervoso/veterinária , Comportamento Animal , Disruptores Endócrinos/análise
8.
J Vet Pharmacol Ther ; 30(3): 218-23, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17472653

RESUMO

This study evaluated the adverse effects of oral firocoxib in dogs. Six dogs (20.2+/-6.3 kg) were studied. Values for complete blood count (CBC), serum urea, creatinine, alanine transaminase, alanine phosphatase, gamma-glutamyl transferase, occult blood in feces, platelet aggregation, and buccal mucosal bleeding time were measured before and 7, 14, 21, and 29 days after SID treatment with firocoxib 5.3+/-0.34 mg/kg (FG) or lactose 1 mg/kg (LG) for 28 days, in a randomized crossover study. Gastrointestinal (GI) tract endoscopy was performed before treatment began and at 29 days. Lesions were scored from grade 0 to 6. Data were analyzed using anova and paired t-tests (P<0.05). None of the dogs presented adverse clinical effects. There were no significant changes in CBC, biochemical profiles within groups, or differences between groups. Pretreatment mean+/-SD bleeding time (LG, 70.7+/-32.1 sec; FG, 75.8+/-38.1 sec) and platelet aggregation (LG, 86.4+/-10.2%; FG, 85.6+/-9.2%) were not significantly different from readings at 29 days (LG, 95.2+/-25 sec; FG, 91.7+/-24 sec and LG, 73.2+/-15.1%; FG, 84+/-10.3%) nor the groups were different. None of the dogs had positive fecal occult blood tests, and endoscopic lesion scores were grade 0 both before treatment and at 29 days. Administration of firocoxib did not cause any adverse effects on GI, or hematological or serum biochemical variables and appears to have been well tolerated by dogs.


Assuntos
4-Butirolactona/análogos & derivados , Inibidores de Ciclo-Oxigenase 2/farmacocinética , Doenças do Cão/induzido quimicamente , Cães/metabolismo , Hipersensibilidade a Drogas/veterinária , Sulfonas/farmacocinética , 4-Butirolactona/administração & dosagem , 4-Butirolactona/efeitos adversos , 4-Butirolactona/sangue , 4-Butirolactona/farmacocinética , Administração Oral , Animais , Análise Química do Sangue/veterinária , Estudos Cross-Over , Inibidores de Ciclo-Oxigenase 2/administração & dosagem , Inibidores de Ciclo-Oxigenase 2/efeitos adversos , Inibidores de Ciclo-Oxigenase 2/sangue , Hipersensibilidade a Drogas/etiologia , Endoscopia Gastrointestinal/veterinária , Feminino , Masculino , Sangue Oculto , Sulfonas/administração & dosagem , Sulfonas/efeitos adversos , Sulfonas/sangue
9.
J Vet Pharmacol Ther ; 29(6): 531-7, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17083457

RESUMO

This study compared pressure and thermal thresholds after administration of three opioids in eight cats. Pressure stimulation was performed via a bracelet taped around the forearm. Three ball-bearings were advanced against the forearm by inflation of a modified blood pressure bladder. Pressure in the cuff was recorded at the end point (leg shake and head turn). Thermal threshold was tested as previously reported using a heated probe held against the thorax [Dixon et al. (2002) Research in Veterinary Science, 72, 205]. After baseline recordings, each cat received subcutaneous methadone 0.2 mg/kg, morphine 0.2 mg/kg, buprenorphine 0.02 mg/kg or saline 0.3 mL in a four period cross-over study. Measurements were made at 15, 30, 45 min and 1, 2, 3, 4, 8, 12 and 24 h after the injection. Data were analysed by anova (P<0.05). There were no significant changes in thresholds after saline. Thermal threshold increased at 45 min after buprenorphine (maximum 2.8+/-3 degrees C), 1-3 h after methadone (maximum 3.4+/-1.9 degrees C) and 45 min to 1 h (maximum 3.4+/-2 degrees C) after morphine. Pressure threshold increased 30-45 min (maximum 238+/-206 mmHg) after buprenorphine, 45-60 min after methadone (maximum 255+/-232 mmHg) and 45-60 min and 3-6 h (maximum 255+/-232 mmHg) after morphine. Morphine provided the best analgesia, and methadone appears a promising alternative. Buprenorphines limited effect was probably related to the subcutaneous route of administration. Previously, buprenorphine has produced much greater effects when given by other routes.


Assuntos
Analgésicos Opioides/farmacologia , Medição da Dor/veterinária , Dor/veterinária , Analgésicos Opioides/administração & dosagem , Animais , Buprenorfina/administração & dosagem , Buprenorfina/farmacologia , Gatos , Feminino , Temperatura Alta , Injeções Subcutâneas/veterinária , Masculino , Metadona/administração & dosagem , Metadona/farmacologia , Morfina/administração & dosagem , Morfina/farmacologia , Dor/prevenção & controle , Medição da Dor/efeitos dos fármacos , Pressão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA