Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Sensors (Basel) ; 20(9)2020 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-32365638

RESUMO

Graffiti is a general term that describes inscriptions on a wall, a practice with ancient origins, ranging from simple drawings and writings to elaborate pictorial representations. Nowadays, the term graffiti commonly describes the street art dedicated to wall paintings, which raises complex questions, including sociological, legal, political and aesthetic issues. Here we examine the aesthetics of graffiti colors by quantitatively characterizing and comparing their chromatic structure to that of traditional paintings in museums and natural scenes obtained by hyperspectral imaging. Two hundred twenty-eight photos of graffiti were taken in the city of São Paulo, Brazil. The colors of graffiti were represented in a color space and characterized by several statistical parameters. We found that graffiti have chromatic structures similar to those of traditional paintings, namely their preferred colors, distribution, and balance. In particular, they have color gamuts with the same degree of elongation, revealing a tendency for combining similar colors in the same proportions. Like more traditional artists, the preferred colors are close to the yellow-blue axis of color space, suggesting that graffiti artists' color choices also mimic those of the natural world. Even so, graffiti tend to have larger color gamuts due to the availability of a new generation of synthetic pigments, resulting in a greater freedom in color choice. A complementary analysis of graffiti from other countries supports the global generalization of these findings. By sharing their color structures with those of paintings, graffiti contribute to bringing art to the cities.

2.
Iperception ; 9(2): 2041669518764192, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29755724

RESUMO

Based on known color vision theories, there is no complete explanation for the perceptual dichotomy of #TheDress in which most people see either white-and-gold (WG) or blue-and-black (BK). We determined whether some standard color vision tests (i.e., color naming, color matching, anomaloscope settings, unique white settings, and color preferences), as well as chronotypes, could provide information on the color perceptions of #TheDress. Fifty-two young observers were tested. Fifteen of the observers (29%) reported the colors as BK, 21 (40%) as WG, and 16 (31%) reported a different combination of colors. Observers who perceived WG required significantly more blue in their unique white settings than those who perceived BK. The BK, blue-and-gold, and WG observer groups had significantly different color preferences for the light cyan chip. Moreland equation anomaloscope matching showed a significant difference between WG and BK observers. In addition, #TheDress color perception categories, color preference outcomes, and unique white settings had a common association. For both the bright and dark regions of #TheDress, the color matching chromaticities formed a continuum, approximately following the daylight chromaticity locus. Color matching to the bright region of #TheDress showed two nearly distinct clusters (WG vs. BK) along the daylight chromaticity locus and there was a clear cutoff for reporting WG versus BK. All results showing a significant difference involved blue percepts, possibly due to interpretations of the illuminant interactions with the dress material. This suggests that variations in attributing blueness to the #TheDress image may be significant variables determining color perception of #TheDress.

3.
Neurotoxicology ; 66: 179-184, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29432854

RESUMO

Land exploitation that follows deforestation and mining can result in soil erosion and the release of mercury to the waters of rivers in the Amazon Basin. Inorganic mercury is methylated by bacteria that are present in the environment and it serves as a source of human contamination through fish consumption in the form of methylmercury. Long-term exposure to low-level methylmercury in the riverside populations can lead to nervous system alterations, some of which are visual impairments such as loss of luminance contrast sensitivity, restricted visual fields and color vision defects. The present study sought to examine color vision in a group of adults living in the central Brazilian Amazon who were exposed to low-levels of methylmercury. Total Hg concentrations were measured from hair collected at the time of the testing. The D15d and FM100 color vision arrangement tests were applied in a population of 36 (22 males) and 42 (25 males), respectively. Controls were healthy volunteers from the cities of São Paulo for the D15d and Belém for the FM100. There was a statistically significant difference in performance between those who were exposed and controls for both tests (p < 0.01 and p < 0.0001, respectively, Mann-Whitney U test), meaning that adults living in this region of the Amazon made more mistakes on both tests when compared to controls. A linear regression was performed using Hg concentrations and test scores. Hg concentrations accounted for 7% and 2% of color D15d and FM100 arrangement test errors, respectively. Although other studies have previously found color vision impairment in the Amazon, they tested inhabitants on the east side of the Amazon, while this study was conducted in the central Amazon region and it is the first study in a population with no direct contact with the Hg source of contamination. These results suggest that long-term exposure to low-level methylmercury in riverside populations is more widely spread in the Amazon Basin than previously reported. This information is needed to implement public health policies that will ensure a safer environment for the Amazonian population.


Assuntos
Defeitos da Visão Cromática/induzido quimicamente , Exposição Ambiental , Compostos de Metilmercúrio/efeitos adversos , Adolescente , Adulto , Brasil , Feminino , Cabelo/química , Humanos , Masculino , Compostos de Metilmercúrio/análise , Pessoa de Meia-Idade , Testes Visuais , Adulto Jovem
4.
Psychol. neurosci. (Impr.) ; 6(2): 227-234, jul.-dez. 2013. ilus, tab
Artigo em Inglês | LILACS | ID: lil-699239

RESUMO

Early visual changes caused by diabetes include color vision losses and an abnormal full-field electroretinogram. The purpose of this study was to evaluate color vision in type 2 diabetic patients with no clinically detectable retinopathy using an objective psychophysical color vision test, evaluate retinal function assessed by full-field electroretinography (ffERG), and verify the agreement among the changes detected by each of these tests. Color vision was tested and ffERG was performed in 34 diabetic patients (20 males; ages 56 ± 9 years). Results were compared with those obtained from age-matched control groups. Color discrimination losses occurred in all three color-confusion axes with a higher incidence on the protan axis. The full-field electroretinographic data indicated that inner retinal components (i.e., ffERG oscillatory potentials) were more affected than outer retinal components, indicating impairment of second- and third-order retinal neurons early in the disease. Previous studies reported tritan losses as a classic color vision defect in diabetes, but our results showed that all three color-confusion axes (i.e., protan, deutan, and tritan) are compromised, at least during the very early stages of the disease, reflecting a diffuse pattern of color vision loss. The full-field electroretinographic results that showed abnormalities of the inner retina support the color vision findings...


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Visão de Cores , Diabetes Mellitus , Retinopatia Diabética/etiologia , Eletrofisiologia , Psicofísica/métodos , Percepção Visual
5.
Arq Bras Oftalmol ; 76(5): 270-3, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24232938

RESUMO

PURPOSE: The present study aimed to compare the postoperative contrast sensitivity functions between wavefront-guided LASIK eyes and their contralateral wavefront-guided PRK eyes. METHODS: The participants were 11 healthy subjects (mean age=32.4 ± 6.2 years) who had myopic astigmatism. The spatial contrast sensitivity functions were measured before and three times after the surgery. Psycho and a Cambridge graphic board (VSG 2/4) were used to measure luminance, red-green, and blue-yellow spatial contrast sensitivity functions (from 0.85 to 13.1 cycles/degree). Longitudinal analysis and comparison between surgeries were performed. RESULTS: There was no significant contrast sensitivity change during the one-year follow-up measurements neither for LASIK nor for PRK eyes. The comparison between procedures showed no differences at 12 months postoperative. CONCLUSIONS: The present data showed similar contrast sensitivities during one-year follow-up of wave-front guided refractive surgeries. Moreover, one year postoperative data showed no differences in the effects of either wavefront-guided LASIK or wavefront-guided PRK on the luminance and chromatic spatial contrast sensitivity functions.


Assuntos
Astigmatismo/cirurgia , Sensibilidades de Contraste/fisiologia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Miopia/cirurgia , Ceratectomia Fotorrefrativa/métodos , Adulto , Feminino , Humanos , Luz , Masculino , Estudos Prospectivos , Procedimentos Cirúrgicos Refrativos/métodos , Resultado do Tratamento
6.
Arq. bras. oftalmol ; Arq. bras. oftalmol;76(5): 270-273, set.-out. 2013. ilus
Artigo em Inglês | LILACS | ID: lil-690602

RESUMO

PURPOSE: The present study aimed to compare the postoperative contrast sensitivity functions between wavefront-guided LASIK eyes and their contralateral wavefront-guided PRK eyes. METHODS: The participants were 11 healthy subjects (mean age=32.4 ± 6.2 years) who had myopic astigmatism. The spatial contrast sensitivity functions were measured before and three times after the surgery. Psycho and a Cambridge graphic board (VSG 2/4) were used to measure luminance, red-green, and blue-yellow spatial contrast sensitivity functions (from 0.85 to 13.1 cycles/degree). Longitudinal analysis and comparison between surgeries were performed. RESULTS: There was no significant contrast sensitivity change during the one-year follow-up measurements neither for LASIK nor for PRK eyes. The comparison between procedures showed no differences at 12 months postoperative. CONCLUSIONS: The present data showed similar contrast sensitivities during one-year follow-up of wave-front guided refractive surgeries. Moreover, one year postoperative data showed no differences in the effects of either wavefront-guided LASIK or wavefront-guided PRK on the luminance and chromatic spatial contrast sensitivity functions.


OBJETIVO: A proposta do presente estudo é comparar funções de sensibilidade ao contraste obtidas após wavefront-LASIK e wavefront-PRK no olho contralateral. MÉTODOS: Os participantes foram 11 sujeitos saudáveis (idade média=32,4 ± 6,2 anos) com astigmatismo miópico. As funções de sensibilidade ao contraste espacial foram obtidas antes e três vezes após a cirurgia. O programa Psycho e uma placa gráfica da Cambridge Research Systems (VSG 2/4) permitiram gerar os estímulos com contraste espacial de luminância e cromático (verde-vermelho e azul-amarelo) de 0,85 até 13,1 ciclos/grau. Análises longitudinais e comparações entre as cirurgias foram realizadas. RESULTADOS: Não houve mudança significativa da sensibilidade ao contraste durante o primeiro ano após a cirurgia para o olho que recebeu o LASIK ou para o olho que recebeu o PRK. A comparação entre as cirurgias também foi semelhante no pós-operatório de um ano. CONCLUSÕES: Os resultados apresentados mostraram sensibilidade ao contraste semelhante durante o primeiro ano após a cirurgia refrativa com o wavefront. Além disso, no pós-operatório de um ano não houve diferença nas funções de sensibilidade ao contraste de luminância e cromático entre os olhos que receberam LASIK e os que receberam PRK.


Assuntos
Adulto , Feminino , Humanos , Masculino , Astigmatismo/cirurgia , Sensibilidades de Contraste/fisiologia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Miopia/cirurgia , Ceratectomia Fotorrefrativa/métodos , Luz , Estudos Prospectivos , Procedimentos Cirúrgicos Refrativos/métodos , Resultado do Tratamento
7.
Psychol. neurosci. (Impr.) ; 6(2): 227-234, 2013. ilus, tab
Artigo em Inglês | Index Psicologia - Periódicos | ID: psi-61335

RESUMO

Early visual changes caused by diabetes include color vision losses and an abnormal full-field electroretinogram. The purpose of this study was to evaluate color vision in type 2 diabetic patients with no clinically detectable retinopathy using an objective psychophysical color vision test, evaluate retinal function assessed by full-field electroretinography (ffERG), and verify the agreement among the changes detected by each of these tests. Color vision was tested and ffERG was performed in 34 diabetic patients (20 males; ages 56 ± 9 years). Results were compared with those obtained from age-matched control groups. Color discrimination losses occurred in all three color-confusion axes with a higher incidence on the protan axis. The full-field electroretinographic data indicated that inner retinal components (i.e., ffERG oscillatory potentials) were more affected than outer retinal components, indicating impairment of second- and third-order retinal neurons early in the disease. Previous studies reported tritan losses as a classic color vision defect in diabetes, but our results showed that all three color-confusion axes (i.e., protan, deutan, and tritan) are compromised, at least during the very early stages of the disease, reflecting a diffuse pattern of color vision loss. The full-field electroretinographic results that showed abnormalities of the inner retina support the color vision findings.(AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Visão de Cores , Diabetes Mellitus , Retinopatia Diabética/etiologia , Psicofísica/métodos , Eletrofisiologia , Percepção Visual
8.
J Refract Surg ; 26(8): 588-93, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19810663

RESUMO

PURPOSE: To compare intraocular straylight measurements and contrast sensitivity after wavefront-guided LASIK (WFG LASIK) in one eye and wavefront-guided photorefractive keratectomy (WFG PRK) in the fellow eye for myopia and myopic astigmatism correction. METHODS: A prospective, randomized study of 22 eyes of 11 patients who underwent simultaneous WFG LASIK and WFG PRK (contralateral eye). Both groups were treated with the NIDEK Advanced Vision Excimer Laser System, and a microkeratome was used for flap creation in the WFG LASIK group. High and low contrast visual acuity, wavefront analysis, contrast sensitivity, and retinal straylight measurements were performed preoperatively and at 3, 6, and 12 months postoperatively. A third-generation straylight meter, C-Quant (Oculus Optikgeräte GmbH), was used for measuring intraocular straylight. RESULTS: Twelve months postoperatively, mean uncorrected distance visual acuity was -0.06 +/- 0.07 logMAR in the WFG LASIK group and -0.10 +/- 0.10 logMAR in the WFG PRK group. Mean preoperative intraocular straylight was 0.94 +/- 0.12 logs for the WFG LASIK group and 0.96 +/- 0.11 logs for the WFG PRK group. After 12 months, the mean straylight value was 1.01 +/- 0.1 log s for the WFG LASIK group and 0.97 +/- 0.12 log s for the WFG PRK group. No difference was found between techniques after 12 months (P = .306). No significant difference in photopic and mesopic contrast sensitivity between groups was noted. CONCLUSIONS: Intraocular straylight showed no statistically significant increase 1 year after WFG LASIK and WFG PRK. Higher order aberrations increased significantly after surgery for both groups. Nevertheless, WFG LASIK and WFG PRK yielded excellent visual acuity and contrast sensitivity performance without significant differences between techniques.


Assuntos
Sensibilidades de Contraste/fisiologia , Ofuscação , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Miopia/cirurgia , Ceratectomia Fotorrefrativa/métodos , Complicações Pós-Operatórias , Espalhamento de Radiação , Adulto , Humanos , Lasers de Excimer/uso terapêutico , Luz , Estudos Prospectivos , Acuidade Visual/fisiologia
9.
J Occup Environ Med ; 51(12): 1403-12, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19952794

RESUMO

OBJECTIVE: To evaluate whether there are visual and neuropsychological decrements in workers with low exposure to Hg vapor. METHODS: Visual fields, contrast sensitivity, color vision, and neuropsychological functions were measured in 10 workers (32.5 +/- 8.5 years) chronically exposed to Hg vapor (4.3 +/- 2.8 years; urinary Hg concentration 22.3 +/- 9.3 microg/g creatinine). RESULTS: For the worst eyes, we found altered visual field thresholds, lower contrast sensitivity, and color discrimination compared with controls (P <0.05). There were no significant differences between Hg-exposed subjects and controls on neuropsychological tests. Nevertheless, duration of exposure was statistically correlated to verbal memory and depression scores. CONCLUSIONS: Chronic exposure to Hg vapor at currently accepted safety levels was found to be associated with visual losses but not with neuropsychological dysfunctions in the sample of workers studied.


Assuntos
Poluentes Ocupacionais do Ar/efeitos adversos , Transtornos Mentais/induzido quimicamente , Transtornos Mentais/epidemiologia , Exposição Ocupacional/efeitos adversos , Transtornos da Visão/induzido quimicamente , Transtornos da Visão/epidemiologia , Adulto , Poluentes Ocupacionais do Ar/urina , Brasil/epidemiologia , Percepção de Cores/efeitos dos fármacos , Testes de Percepção de Cores , Sensibilidades de Contraste/efeitos dos fármacos , Creatinina/urina , Feminino , Humanos , Masculino , Mercúrio/urina , Pessoa de Meia-Idade , Testes Neuropsicológicos , Exposição Ocupacional/análise , Campos Visuais/efeitos dos fármacos , Adulto Jovem
10.
Vis Neurosci ; 25(3): 463-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18598419

RESUMO

We assessed chromatic discrimination in multiple sclerosis (MS) patients both with (ON) and without (no ON) a history of optic neuritis using the Cambridge color test (CCT). Our goal was to determine the magnitude and chromatic axes of any color vision losses in both patient groups, and to evaluate age-related changes in chromatic discrimination in both patient groups compared to normals. Using the CCT, we measured chromatic discrimination along the protan, deutan and tritan axes in 35 patients with MS (17 ON eyes) and 74 age matched controls. Color thresholds for both patient groups were significantly higher than controls' along the protan and tritan axes (p < 0.001). In addition, the ON and no-ON groups differed significantly along all three-color axes (p < 0.001). MS patients presented a progressive color discrimination impairment with age (along the deutan and tritan axes) that was almost two times faster than controls, even in the absence of ON. These findings suggest that demyelinating diseases reduce sensitivity to color vision in both red-green and blue-yellow axes, implying impairment in both parvocellular and koniocellular visual pathways. The CCT is a useful tool to help characterize vision losses in MS, and the relationship between these losses and degree of optic nerve involvement.


Assuntos
Testes de Percepção de Cores , Defeitos da Visão Cromática/etiologia , Defeitos da Visão Cromática/fisiopatologia , Esclerose Múltipla/complicações , Neurite Óptica/etiologia , Limiar Sensorial/fisiologia , Adolescente , Adulto , Idade de Início , Calibragem , Criança , Percepção de Cores , Discriminação Psicológica , Feminino , Lateralidade Funcional/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Neurite Óptica/fisiopatologia , Estimulação Luminosa
11.
Vis Neurosci ; 25(3): 487-91, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18598423

RESUMO

This longitudinal study addresses the reversibility of color vision losses in subjects who had been occupationally exposed to mercury vapor. Color discrimination was assessed in 20 Hg-exposed patients (mean age = 42.4 +/- 6.5 years; 6 females and 14 males) with exposure to Hg vapor during 10.5 +/- 5.3 years and away from the work place (relative to 2002) for 6.8 +/- 4.2 years. During the Hg exposure or up to one year after ceasing it, mean urinary Hg concentration was 47 +/- 35.4 mug/g creatinine. There was no information on Hg urinary concentration at the time of the first tests, in 2002 (Ventura et al., 2005), but at the time of the follow-up tests, in 2005, this value was 1.4 +/- 1.4 microg/g creatinine for patients compared with 0.5 +/- 0.5 microg/g creatinine for controls (different group from the one in Ventura et al. (2005)). Color vision was monocularly assessed using the Cambridge Colour Test (CCT). Hg-exposed patients had significantly worse color discrimination (p < 0.02) than controls, as evaluated by the size of MacAdam's color discrimination ellipses and color discrimination thresholds along protan, deutan, and tritan confusion axes. There were no significant differences between the results of the study in Ventura et al. (2005) and in the present follow-up measurements, in 2005, except for worsening of the tritan thresholds in the best eye in 2005. Both chromatic systems, blue-yellow and red-green, were affected in the first evaluation (Ventura et al., 2005) and remained impaired in the follow-up testing, in 2005. These findings indicate that following a long-term occupational exposure to Hg vapor, even several years away from the source of intoxication, color vision impairment remains irreversible.


Assuntos
Defeitos da Visão Cromática/induzido quimicamente , Mercúrio/toxicidade , Adulto , Percepção de Cores/efeitos dos fármacos , Percepção de Cores/fisiologia , Testes de Percepção de Cores , Creatinina/urina , Feminino , Humanos , Estudos Longitudinais , Masculino , Mercúrio/urina , Intoxicação por Mercúrio/fisiopatologia , Pessoa de Meia-Idade , Doenças Profissionais/fisiopatologia , Exposição Ocupacional
12.
Environ Res ; 107(1): 124-31, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-17719027

RESUMO

Visual field losses associated with mercury (Hg) exposure have only been assessed in patients exposed to methylmercury. Here we evaluate the automated visual field in 35 ex-workers (30 males; 44.20+/-5.92 years) occupationaly exposed to mercury vapor and 34 controls (21 males; 43.29+/-8.33 years). Visual fields were analyzed with the Humphrey Field Analyzer II (model 750i) using two tests: the standard automated perimetry (SAP, white-on-white) and the short wavelength automated perimetry (SWAP, blue-on-yellow) at 76 locations within a 27 degrees central visual field. Results were analyzed as the mean of the sensitivities measured at the fovea, and at five successive concentric rings, of increasing eccentricity, within the central field. Compared to controls, visual field sensitivities of the experimental group measured using SAP were lower for the fovea as well as for all five eccentricity rings (p<0.05). Sensitivities were significantly lower in the SWAP test (p<0.05) for four of the five extra-foveal eccentricity rings; they were not significant for the fovea (p=0.584) or for the 15 degrees eccentricity ring (p=0.965). These results suggest a widespread reduction of sensitivity in both visual field tests. Previous reports in the literature describe moderate to severe concentric constriction of the visual field in subjects with methylmercury intoxication measured manually with the Goldman perimeter. The present results amplify concerns regarding potential medical risks of exposure to environmental mercury sources by demonstrating significant and widespread reductions of visual sensitivity using the more reliable automated perimetry.


Assuntos
Poluentes Ocupacionais do Ar/toxicidade , Intoxicação por Mercúrio/fisiopatologia , Mercúrio/toxicidade , Exposição Ocupacional , Campos Visuais/fisiologia , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
13.
Am J Hum Genet ; 80(6): 1064-75, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17503325

RESUMO

The present study evaluated the color vision of 44 patients with Duchenne muscular dystrophy (DMD) (mean age 14.8 years; SD 4.9) who were submitted to a battery of four different color tests: Cambridge Colour Test (CCT), Neitz Anomaloscope, Ishihara, and American Optical Hardy-Rand-Rittler (AO H-R-R). Patients were divided into two groups according to the region of deletion in the dystrophin gene: upstream of exon 30 (n=12) and downstream of exon 30 (n=32). The control group was composed of 70 age-matched healthy male subjects with no ophthalmological complaints. Of the patients with DMD, 47% (21/44) had a red-green color vision defect in the CCT, confirmed by the Neitz Anomaloscope with statistical agreement (P<.001). The Ishihara and the AO H-R-R had a lower capacity to detect color defects--5% and 7%, respectively, with no statistical similarity between the results of these two tests nor between CCT and Anomaloscope results (P>.05). Of the patients with deletion downstream of exon 30, 66% had a red-green color defect. No color defect was found in the patients with deletion upstream of exon 30. A negative correlation between the color thresholds and age was found for the controls and patients with DMD, suggesting a nonprogressive color defect. The percentage (66%) of patients with a red-green defect was significantly higher than the expected <10% for the normal male population (P<.001). In contrast, patients with DMD with deletion upstream of exon 30 had normal color vision. This color defect might be partially explained by a retina impairment related to dystrophin isoform Dp260.


Assuntos
Testes de Percepção de Cores/métodos , Percepção de Cores , Defeitos da Visão Cromática/diagnóstico , Deleção de Genes , Distrofia Muscular de Duchenne/genética , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Defeitos da Visão Cromática/classificação , Distrofina/deficiência , Distrofina/genética , Éxons , Humanos , Masculino , Valores de Referência , Sensibilidade e Especificidade
14.
Vis Neurosci ; 23(3-4): 663-8, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16962010

RESUMO

Color vision impairment was examined in patients with type 2 diabetes mellitus (DM2) without retinopathy. We assessed the type and degree of distortions of individual color spaces. DM2 patients (n = 32), and age-matched controls (n = 20) were tested using the Farnsworth D-15 and the Lanthony D-15d tests. In addition, subsets of caps from both tests were employed in a triadic procedure (Bimler & Kirkland, 2004). Matrices of inter-cap subjective dissimilarities were estimated from each subject's "odd-one-out" choices, and processed using non-metric multidimensional scaling. Two-dimensional color spaces, individual and group (DM2 patients; controls), were reconstructed, with the axes interpreted as the R/G and B/Y perceptual opponent systems. Compared to controls, patient results were not significant for the D-15 and D-15d. In contrast, in the triadic procedure the residual distances were significantly different compared to controls: right eye, P = 0.021, and left eye, P = 0.022. Color space configurations for the DM2 patients were compressed along the B/Y and R/G dimensions. The present findings agree with earlier studies demonstrating diffuse losses in early stages of DM2. The proposed method of testing uses color spaces to represent discrimination and provides more differentiated quantitative diagnosis, which may be interpreted as the perceptual color system affected. In addition, it enables the detection of very mild color vision impairment that is not captured by the D-15d test. Along with fundoscopy, individual color spaces may serve for monitoring early functional changes and thereby to support a treatment strategy.


Assuntos
Percepção de Cores/fisiologia , Defeitos da Visão Cromática/etiologia , Diabetes Mellitus Tipo 2/complicações , Percepção Espacial/fisiologia , Adulto , Idoso , Cor , Testes de Percepção de Cores/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa/métodos
15.
Psicol. USP ; 17(4): 35-62, 2006. ilus
Artigo em Português | LILACS | ID: lil-457252

RESUMO

O artigo apresenta definições para os termos espaço de cores e sistemas de cores; classifica, de acordo com David Brainard (2003), os sistemas de cores em dois grupos: aparência de cores e diferenças de cores. Dentre os diversos sistemas de cores existentes, o artigo descreve dois deles: o sistema de cores Munsell – um dos mais utilizados entre os sistemas de aparência de cores – e a descrição do sistema de cores CIE 1931 – um dos mais utilizados dentre os sistemas de diferença de cores. Faz-se uma retrospectiva histórica da busca por espaços de cores que representem a percepção de cores humana assim como as diversas reconstruções de espaços de cores por métodos eletrofisiológicos ou psicofísicos. Muitas dessas reconstruções utilizam a escala multidimensional (mds). O artigo também introduz a possibilidade da reconstrução dos espaços de cores de pacientes com discromatopsia adquirida como uma distorção do espaço de indivíduos tricromatas normais


Assuntos
Percepção de Cores , Psicofísica
16.
Psicol. USP ; 17(4): 35-62, 2006. ilus
Artigo em Português | Index Psicologia - Periódicos | ID: psi-34310

RESUMO

O artigo apresenta definições para os termos espaço de cores e sistemas de cores; classifica, de acordo com David Brainard (2003), os sistemas de cores em dois grupos: aparência de cores e diferenças de cores. Dentre os diversos sistemas de cores existentes, o artigo descreve dois deles: o sistema de cores Munsell – um dos mais utilizados entre os sistemas de aparência de cores – e a descrição do sistema de cores CIE 1931 – um dos mais utilizados dentre os sistemas de diferença de cores. Faz-se uma retrospectiva histórica da busca por espaços de cores que representem a percepção de cores humana assim como as diversas reconstruções de espaços de cores por métodos eletrofisiológicos ou psicofísicos. Muitas dessas reconstruções utilizam a escala multidimensional (mds). O artigo também introduz a possibilidade da reconstrução dos espaços de cores de pacientes com discromatopsia adquirida como uma distorção do espaço de indivíduos tricromatas normais (AU)


Assuntos
Percepção de Cores , Psicofísica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA