Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Anal Chem Insights ; 9: 49-55, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24940040

RESUMO

A stripping method for the determination of xanthine in the presence of hypoxanthine at the submicromolar concentration levels is described. The method is based on controlled adsorptive accumulation at the thin-film mercury electrode followed by a fast linear scan voltammetric measurement of the surface species. Optimum experimental conditions were found to be the use of 1.0 × 10(-3) mol L(-1) NaOH solution as supporting electrolyte, an accumulation potential of 0.00 V for xanthine and -0.50 V for hypoxanthine-copper, and a linear scan rate of 200 mV second(-1). The response of xanthine is linear over the concentration ranges of 20-140 ppb. For an accumulation time of 30 minutes, the detection limit was found to be 36 ppt (2.3 × 10(-10) mol L(-1)). Adequate conditions for measuring the xanthine in the presence of hypoxanthine, copper and other metals, uric acid, and other nitrogenated bases were also investigated. The utility of the method is demonstrated by the presence of xanthine associated with hypoxanthine, uric acid, nitrogenated bases, ATP, and ssDNA.

2.
Anal Chem Insights ; 8: 21-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23761958

RESUMO

This paper describes a stripping method for the determination of acyclovir at the submicromolar concentration level. This method is based on controlled adsorptive accumulation of acyclovir at thin-film mercury electrode, followed by a linear cyclic scan voltammetry measurement of the surface species. Optimal experimental conditions include a NaOH solution of 2.0 × 10(-3) mol L(-1) (supporting electrolyte), an accumulation potential of -0.40 V, and a scan rate of 100 mV s(-1). The response of acyclovir is linear over the concentration range 0.02 to 0.12 ppm. For an accumulation time of 4 minutes, the detection limit was found to be 0.42 ppb (1.0 × 10(-9) mol L(-1)). More convenient methods to measure the acyclovir in presence of the didanosine, efavirenz, nevirapine, nelfinavir, lamivudine, and zidovudine were also investigated. The utility of this method is demonstrated by the presence of acyclovir together with Adenosine triphosphate (ATP) or DNA.

3.
J Pharm (Cairo) ; 2013: 495814, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-26555981

RESUMO

The zalcitabine (ddC) has been extensively used in the treatment of HIV patients due to its antiretroviral activity. The quality control of this active principle in medications is of outstanding importance to public health. The principal objective of the current study was the development of an alternative analytical methodology for the zalcitabine determination using a voltammetric process. The zalcitabine gives a reduction peak (at -1.22 V versus Ag/AgCl) at the hanging mercury drop electrode (HMDE). The differential pulse voltammetric response is evaluated with respect to the scan rate (20 mV/s), pulse amplitude (50 mV), support electrolyte (Clark-Lubs buffer), pH (2.0), and other variables. The response is linear over the 10.0 to 28.0 mg/L (47 to 133 µM) concentration range, and the detection limit is 2.08 mg/L. The validation of this method was realized using a governmental Brazilian document (Inmetro, 2007) and the results are reported for medication drugs.

4.
Comb Chem High Throughput Screen ; 14(1): 22-7, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20958254

RESUMO

This paper describes a stripping method for the determination of nevirapine at the submicromolar concentration levels. The method is based on controlled adsorptive accumulation of nevirapine at thin-film mercury electrode, followed by a linear cyclic scan voltammetry measurement of the surface species. Optimal experimental conditions include a 2.0 x 10(-3) mol L(-1) NaOH solution (supporting electrolyte), an accumulation potential of -0.20 V, and a scan rate of 100 mV s(-1). The response of nevirapine is linear over the concentration range 0.01-0.14 ppm. For an accumulation time of 6 minutes, the detection limit was found to be 0.87 ppb (3.0 x 10(-9) mol L(-1)). More convenient methods to measure the nevirapine in presence of the efavirenz, acyclovir, didanosine, indinavir, nelfinavir, saquinavir, lamivudine, zidovudine and metals ions were also investigated. The utility of this method is demonstrated by the presence of nevirapine together with ATP or DNA.


Assuntos
Álcalis/química , Eletrodos , Eletrólitos/química , Mercúrio/química , Nevirapina/análise , Inibidores da Transcriptase Reversa/análise , Adsorção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA