Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Oral Maxillofac Surg ; 68(4): 825-32, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20307767

RESUMO

PURPOSE: The aim of the present study was to investigate the healing, integration, and maintenance of autogenous onlay bone grafts and implant osseointegration either loaded in the early or the delayed stages. MATERIALS AND METHODS: A total of 5 male dogs received bilateral blocks of onlay bone grafts harvested from the contralateral alveolar ridge of the mandible. On one side, the bone block was secured by 3 dental implants (3.5 mm x 13.0 mm, Osseospeed; AstraTech AB, Mölndal, Sweden). Two implants at the extremities of the graft were loaded 2 days after installation by abutment connection and prosthesis (simultaneous implant placement group); the implant in the middle remained unloaded and served as the control. On the other side, the block was fixed with 2 fixation screws inserted in the extremities of the graft. Four weeks later, the fixation screws were replaced with 3 dental implants. The loading procedure (delayed implant placement group) was performed 2 days later, as described for the simultaneous implant placement sites. The animals were sacrificed 12 weeks after the grafting procedure. Implant stability was measured through resonance frequency analysis. The bone volume and density were assessed on computed tomography. The bone to implant contact and bone area in a region of interest were evaluated on histologic slides. RESULTS: The implant stability quotient showed statistical significance in favor of the delayed loaded grafts (P = .001). The bone-to-implant contact (P = .008) and bone area in a region of interest (P = 0.005) were significantly greater in the delayed group. Nevertheless, no difference was found in terms of graft volume and density between the early loaded and delayed-loaded approaches. CONCLUSIONS: The protocol in which the implant and bone graft were given delayed loading allows for effective quality of implant osseointegration and stabilization, with healing and remodeling occurring in areas near the implant resulting in denser bone architecture.


Assuntos
Aumento do Rebordo Alveolar/métodos , Transplante Ósseo , Implantação Dentária Endóssea , Prótese Dentária Fixada por Implante , Osseointegração , Análise de Variância , Animais , Densidade Óssea , Parafusos Ósseos , Dente Suporte , Retenção em Prótese Dentária , Análise do Estresse Dentário , Cães , Masculino , Probabilidade , Estatísticas não Paramétricas , Fatores de Tempo , Tomografia Computadorizada por Raios X , Vibração
2.
J Oral Maxillofac Surg ; 66(4): 647-56, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18355588

RESUMO

PURPOSE: Bone maintenance after mandibular reconstruction with autogenous iliac crest may be disappointing due to extensive resorption in the long term. The potential of the guided-bone regeneration (GBR) technique to enhance the healing process in segmental defects lacks comprehensive scientific documentation. This study aimed to investigate the influence of polylactide membrane permeability on the fate of iliac bone graft (BG) used to treat mandibular segmental defects. MATERIALS AND METHODS: Unilateral 10-mm-wide segmental defects were created through the mandibles of 34 mongrel dogs. All defects were mechanically stabilized, and the animals were divided into 6 treatment groups: control, BG alone, microporous membrane (poly L/DL-lactide 80/20%) (Mi); Mi plus BG; microporous laser-perforated (15 cm(2) ratio) membrane (Mip), and Mip plus BG. Calcein fluorochrome was injected intravenously at 3 months, and animal euthanasia was carried out at 6 months postoperatively. RESULTS: Histomorphometry showed that BG protected by Mip was consistently related to larger amounts of bone compared with other groups (P

Assuntos
Regeneração Óssea , Transplante Ósseo/métodos , Regeneração Tecidual Guiada Periodontal/métodos , Mandíbula/cirurgia , Membranas Artificiais , Implantes Absorvíveis , Análise de Variância , Animais , Cães , Masculino , Permeabilidade , Poliésteres , Porosidade , Procedimentos de Cirurgia Plástica/métodos
3.
Clin Oral Implants Res ; 19(4): 393-401, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18324960

RESUMO

The information concerning the molecular events taking place in onlay bone grafts are still incipient. The objective of the present study is to correlate the effects of perforation of resident bone bed on (1) the timing of onlay autogenous graft revascularization; (2) the maintenance of volume/density of the graft (assessed through tomography); and (3) the occurrence of bone remodeling proteins (using immunohistochemistry technique) delivered in the graft. Thirty-six New Zealand White rabbits were subjected to iliac crest onlay bone grafting on both sides of the mandible. The bone bed was drill-perforated on one side aiming at accelerating revascularization, whereas on the other side it was kept intact. After grafts fixation and flaps suture all animals were submitted to tomography on both mandible sites. Six animals were sacrificed, respectively, at 3, 5, 7, 10, 20 and 60 days after surgery. A second tomography was taken just before sacrifice. Histological slides were prepared from each grafted site for both immunohistochemistry analysis [osteopontin, osteocalcin, type I collagen and vascular endothelial growth factor (VEGF) anti-bodies] and histometric analysis. The values on bone volume measured on tomography showed no statistic significance (P>or=0.05) between perforated and intact sites. Grafts placed on perforated beds showed higher bone density values compared with non-perforated ones at 3 days (P

Assuntos
Remodelação Óssea , Transplante Ósseo/fisiologia , Mandíbula/cirurgia , Neovascularização Fisiológica , Processo Alveolar/irrigação sanguínea , Animais , Densidade Óssea , Colágeno Tipo I/análise , Ílio/cirurgia , Imuno-Histoquímica , Osteocalcina/análise , Osteopontina/análise , Coelhos , Tomografia por Raios X , Fator A de Crescimento do Endotélio Vascular/análise
4.
J Oral Implantol ; 33(5): 267-76, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17987858

RESUMO

Two bovine hydroxyapatites (BHAs), one with granule size of 150 to 200 microm and one with granule size of 300 to 329 micro, and 2 synthetic hydroxyapatites (SHAs), with granule size of 150 and 300 microm, respectively, were compared for effectiveness in repairing circumferential bone defects in dogs. The hydroxyapatites (HAs) were characterized through powder x-ray diffraction (XRD) analysis and scanning electron microscopy (SEM). Three trephined bone defects (5.0 mm wide x 4 mm long) were created in the humeruses of 8 dogs. In a random manner, the defects on each side were treated with either BHA with small granules (BHA[s]), BHA with large granules (BHA[L]), SHA with small granules (SHA[s]), SHA with large granules (SHA[L]), or left to heal unaided (bilateral control). Four dogs were sacrificed after 6 and 12 postoperative weeks, respectively. Ground sections of each defect were submitted to histologic and histomorphometric analysis (percentage of area occupied by bone, bone marrow, and biomaterial). As a rule, the HA granules exhibited direct bone contact, regardless of the origin and the size of the granules. Control sites were related and had an increased amount of connective tissue infiltration. At 12 weeks, BHA(s) exhibited improved bone formation compared with SHA(s) and SHA(L). The SHA(s) delivered reduced amounts of bone compared with the remaining groups (control included). The area of bone measured in BHA(s) sites was significantly higher at 12 weeks than 6 weeks. The XRD revealed the tested HA samples to be highly crystalline, while BHA appeared with rougher surface at SEM analysis. The BHA(s) performed better than the SHA(s) and SHA(L), as assessed by the amount of bone measured in both implantation sites at 12 weeks. The BHA's material characteristic itself rather than granules size accounted for the distinctive biological behavior. The increased roughness of the BHAs' surface, as assessed through SEM, seemed to benefit the osteoconduction process.


Assuntos
Regeneração Óssea/fisiologia , Substitutos Ósseos/química , Hidroxiapatitas/química , Animais , Bovinos , Cristalografia por Raios X , Cães , Úmero/cirurgia , Masculino , Microscopia Eletrônica de Varredura , Tamanho da Partícula , Estatísticas não Paramétricas , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA