Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Methods ; 230: 21-31, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39074539

RESUMO

Envisaging to improve the evaluation of ophthalmic drug products while minimizing the need for animal testing, our group developed the OphthalMimic device, a 3D-printed device that incorporates an artificial lacrimal flow, a cul-de-sac area, a moving eyelid, and a surface that interacts effectively with ophthalmic formulations, thereby providing a close representation of human ocular conditions. An important application of such a device would be its use as a platform for dissolution/release tests that closely mimic in vivo conditions. However, the surface that artificially simulates the cornea should have a higher resistance (10 min) than the previously described polymeric films (5 min). For this key assay upgrade, we describe the process of obtaining and thoroughly characterizing a hydrogel-based hybrid membrane to be used as a platform base to simulate the cornea artificially. Also, the OphthalMimic device suffered design improvements to fit the new membrane and incorporate the moving eyelid. The results confirmed the successful synthesis of the hydrogel components. The membrane's water content (86.25 ± 0.35 %) closely mirrored the human cornea (72 to 85 %). Furthermore, morphological analysis supported the membrane's comparability to the natural cornea. Finally, the performance of different formulations was analysed, demonstrating that the device could differentiate their drainage profile through the viscosity of PLX 14 (79 ± 5 %), PLX 16 (72 ± 4 %), and PLX 20 (57 ± 14 %), and mucoadhesion of PLXCS0.5 (69 ± 1 %), PLX16CS1.0 (65 ± 3 %), PLX16CS1.25 (67 ± 3 %), and the solution (97 ± 8 %). In conclusion, using the hydrogel-based hybrid membrane in the OphthalMimic device represents a significant advancement in the field of ophthalmic drug evaluation, providing a valuable platform for dissolution/release tests. Such a platform aligns with the ethical mandate to reduce animal testing and promises to accelerate the development of safer and more effective ophthalmic drugs.


Assuntos
Hidrogéis , Humanos , Hidrogéis/química , Soluções Oftálmicas/química , Impressão Tridimensional , Córnea/efeitos dos fármacos , Córnea/metabolismo , Administração Oftálmica , Membranas Artificiais
2.
Methods ; 228: 1-11, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38759909

RESUMO

The necessity of animal-free performance tests for novel ophthalmic formulation screening is challenging. For this, we developed and validated a new device to simulate the dynamics and physical-chemical barriers of the eye for in vitro performance tests of topic ophthalmic formulations. The OphthalMimic is a 3D-printed device with an artificial lacrimal flow, a cul-de-sac area, a support base, and a simulated cornea comprised of a polymeric membrane containing poly-vinyl alcohol 10 % (w/v), gelatin 2.5 % (w/v), and different proportions of mucin and poloxamer, i.e., 1:1 (M1), 1:2 (M2), and 2:1 (M3) w/v, respectively. The support base is designed to move between 0° and 50° to replicate the movement of an eyelid. We challenged the model by testing the residence performance of poloxamer®407 16 % and poloxamer®407 16 % + chitosan 1 % (PLX16CS10) gels containing fluconazole. The test was conducted with a simulated tear flow of 1.0 mL.min-1 for 5 min. The OphthalMimic successfully distinguished PLX16 and PLX16C10 formulations based on their fluconazole drainage (M1: 65 ± 14 % and 27 ± 10 %; M2: 58 ± 6 % and 38 ± 9 %; M3: 56 ± 5 % and 38 ± 18 %). In conclusion, the OphthalMimic is a promising tool for comparing the animal-free performance of ophthalmic formulations.


Assuntos
Soluções Oftálmicas , Poloxâmero , Poloxâmero/química , Soluções Oftálmicas/química , Administração Oftálmica , Fluconazol/administração & dosagem , Impressão Tridimensional , Córnea/efeitos dos fármacos , Córnea/metabolismo , Animais , Quitosana/química , Alternativas aos Testes com Animais/métodos , Lágrimas/química , Humanos , Gelatina/química
3.
Pharmaceutics ; 15(9)2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37765293

RESUMO

Animal models are still used in the research and development of ophthalmic drug products, mainly due to the difficulty in simulating natural physiological conditions with in vitro models, as there is a lack of dynamic protection mechanisms. Therefore, developing alternative ophthalmic models that evaluate drug penetration in the cornea while applying dynamic protection barriers is a contemporary challenge. This study aimed to develop a dynamic ex vivo model using porcine eyes with a simulated lacrimal flow to evaluate the performance of pharmaceutical drug products. A glass donor cell to support a simulated tear flow was designed, optimized, and custom-made. The system was challenged with different formulations (with fluconazole) including excipients with different viscosities (poloxamer 407) and mucoadhesive properties (chitosan). The results were compared to those obtained from a conventional excised cornea model mounted in Franz-type diffusion cells. The dynamic model could differentiate formulations, while the static model did not, overestimating ex vivo drug penetrated amounts. Hence, the dynamic model with simulated tear flow showed to be a simple and promising new alternative method for the drug penetration of ophthalmic formulations that ultimately can reduce the number of animals used in research.

4.
Gels ; 9(4)2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-37102881

RESUMO

There is a growing interest in innovative products for eyebrow hair loss treatment with fewer adverse effects. Nevertheless, a fundamental formulation aspect of preventing the fragile skin from the ocular region from being irritated is that the formulations remain restricted to the application region and do not run off. Consequently, the methods and protocols in drug delivery scientific research must be adapted to fulfill such performance analysis demand. Thus, this work aimed to propose a novel protocol to evaluate the in vitro performance of a topical gel formulation with a reduced runoff for minoxidil (MXS) delivery to eyebrows. MXS was formulated with 16% poloxamer 407 (PLX) and 0.4% of hydroxypropyl methylcellulose (HPMC). The sol/gel transition temperature, viscosity at 25 °C, and formulation runoff distance on the skin were evaluated to characterize the formulation. The release profile and skin permeation were evaluated in Franz vertical diffusion cells for 12 h and compared to a control formulation (4% PLX and 0.7% HPMC). Then, the formulation's performance at promoting minoxidil skin penetration with minimum runoff was evaluated in a vertical custom-made permeation template (divided into three areas: superior, middle, and inferior). The MXS release profile from the test formulation was comparable to that from the MXS solution and the control formulation. There was also no difference in the MXS amount that penetrated the skin in the permeation experiments in Franz diffusion cells using the different formulations (p > 0.05). However, the test formulation demonstrated a localized MXS delivery at the application site in the vertical permeation experiment. In conclusion, the proposed protocol could differentiate the test formulation from the control, attesting to its better performance in efficiently delivering MXS to the site of interest (middle third of application). The vertical protocol can be easily employed to evaluate other gels with a drip-free appeal.

5.
Arq. bras. oftalmol ; Arq. bras. oftalmol;84(5): 454-461, Sept.-Oct. 2021. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1339209

RESUMO

ABSTRACT Purpose: The aim of this study was to compare corneal structure and endothelial morphological changes after uneventful phacoemulsification cataract surgery between type 2 diabetic and nondiabetic patients and to determine the preoperative and intraoperative factors that may predict greater endothelial cell density loss. Methods: Forty-five diabetic pa­tients (45 eyes) and 43 controls (43 eyes) with age-related cataract were enrolled in this prospective observational study. Corneal (thickness and volume) and anterior segment parameters were measured by Scheimpflug tomography; endothelial cell density and morphology (coefficient of variation of cell size, hexagonal cells) were recorded using noncontact specular microscopy. Patients were evaluated preoperatively and at one and six months after surgery. Univariate and multivariate linear regression analyses were performed to evaluate the relationship between demographic, clinical, ocular, and intraoperative parameters and postoperative endothelial cell density changes at six months. Results: Significant postoperative endothelial cell loss occurred one month after surgery in both groups (p<0.001), which remained stable until month 6; there were no differences between patients with and without diabetes mellitus at any time point. The mean postoperative central corneal thickness at one and six months did not change significantly from the mean preoperative value in either group (p>0.05). Multivariate linear regression analysis showed that older age (p=0.042) and higher cataract grades (p=0.001) were significantly associated with greater endothelial cell density reduction at six-month follow-up. Conclusion: This study showed that older age and denser cataracts might be associated with greater endothelial cell density reduction after cataract surgery. Other factors, such as diabetes mellitus and preoperative anterior segment parameters, did not influence postoperative changes in endothelial cell density.


RESUMO Objetivo: Comparar a estrutura da córnea e as alterações mor­fológicas endoteliais após cirurgia de catarata por facoemulsificação sem intercorrências entre pacientes com diabetes mellitus tipo 2 e não diabéticos; e determinar quais fatores pré e intra-operatórios relacionados com a maior redução da densidade celular endotelial. Métodos: Quarenta e cinco diabéticos (45 olhos) e 43 (43 olhos) controlos com catarata relacionada à idade foram incluídos neste estudo observacional prospectivo. Os parâmetros da córnea (espessura e volume) e do segmento anterior foram medidos pela tomografia Scheimpflug; a densidade e morfologia celular endotelial (coeficiente de variação do tamanho das células, células hexagonais) foram registrados usando microscopia especular não contato. Os pacientes foram avaliados no pré-operatório, 1 e 6 meses após a cirurgia. Foi realizada uma análise de regressão linear uni e multivariada para avaliar a relação entre os parâmetros demográficos, clínicos, oculares e intra-operatórios com a redução da densidade celular endotelial aos 6 meses. Resultados: Nos dois grupos houve uma perda significativa de células endoteliais ao 1º mês pós-ope­ratório (p<0,001), que permaneceu estável até ao 6º mês; sem diferenças estatisticas entre os grupos diabetes mellitus e não diabetes mellitus em qualquer avaliação. A espessura média da córnea no pós-operatório central aos 1 e 6 meses não mudou significativamente em relação ao valor médio pré-operatório nos dois grupos (p>0.05). A análise de regressão multivariada linear mostrou que a idade avançada (p=0.042) e os graus mais elevados de catarata (p=0.001) foram significativamente associados à maior redução densidade celular endotelial aos 6 meses de seguimento. Conclusão: Este estudo mostrou que a idade avançada e as cataratas mais densas podem predispor a uma maior redução densidade celular endotelial após a cirurgia de catarata. Outros fatores, como diabetes mellitus e parâmetros pré-operatórios do segmento anterior, não influenciaram significativamente as alterações pós-operatórias da densidade celular endotelial.

6.
Arq Bras Oftalmol ; 84(5): 454-461, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34550218

RESUMO

PURPOSE: The aim of this study was to compare corneal structure and endothelial morphological changes after uneventful phacoemulsification cataract surgery between type 2 diabetic and nondiabetic patients and to determine the preoperative and intraoperative factors that may predict greater endothelial cell density loss. METHODS: Forty-five diabetic pa-tients (45 eyes) and 43 controls (43 eyes) with age-related cataract were enrolled in this prospective observational study. Corneal (thickness and volume) and anterior segment parameters were measured by Scheimpflug tomography; endothelial cell density and morphology (coefficient of variation of cell size, hexagonal cells) were recorded using noncontact specular microscopy. Patients were evaluated preoperatively and at one and six months after surgery. Univariate and multivariate linear regression analyses were performed to evaluate the relationship between demographic, clinical, ocular, and intraoperative parameters and postoperative endothelial cell density changes at six months. RESULTS: Significant postoperative endothelial cell loss occurred one month after surgery in both groups (p<0.001), which remained stable until month 6; there were no differences between patients with and without diabetes mellitus at any time point. The mean postoperative central corneal thickness at one and six months did not change significantly from the mean preoperative value in either group (p>0.05). Multivariate linear regression analysis showed that older age (p=0.042) and higher cataract grades (p=0.001) were significantly associated with greater endothelial cell density reduction at six-month follow-up. CONCLUSION: This study showed that older age and denser cataracts might be associated with greater endothelial cell density reduction after cataract surgery. Other factors, such as diabetes mellitus and preoperative anterior segment parameters, did not influence postoperative changes in endothelial cell density.


Assuntos
Catarata , Diabetes Mellitus Tipo 2 , Facoemulsificação , Idoso , Contagem de Células , Córnea , Diabetes Mellitus Tipo 2/complicações , Endotélio Corneano , Humanos , Estudos Prospectivos
7.
J Sep Sci ; 38(17): 3038-46, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26140379

RESUMO

The Baccharis genus has more than 400 species of aromatic plants. However, only approximately 50 species have been studied in oil composition to date. From these studies, very few take into consideration differences between male and female plants, which is a significant and distinctive factor in Baccharis in the Asteraceae family. Baccharis articulata is a common shrub that grows wild in south Brazil, northern and central Argentina, Bolivia, Paraguay and Uruguay. It is considered to be a medicinal plant and is employed in traditional medicine. We report B. articulata male and female volatile composition obtained by simultaneous distillation-extraction technique and analyzed by gas chromatography with mass spectrometry. Also, an assessment of aromatic differences between volatile extracts was evaluated by gas chromatography with olfactometry. The results show a very similar chemical composition between male and female extracts, with a high proportion of terpene compounds of which ß-pinene, limonene and germacrene D are the main components. Despite the chemical similarity, great differences in aromatic profile were found: male plant samples exhibited the strongest odorants in number and intensity of aromatic attributes. These differences explain field observations which indicate differences between male and female flower aroma, and might be of ecological significance in the attraction of pollinating insects.


Assuntos
Baccharis/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Olfatometria/métodos , Extratos Vegetais/análise , Baccharis/fisiologia , Monoterpenos Bicíclicos , Compostos Bicíclicos com Pontes/análise , Cromatografia em Camada Fina , Cicloexenos/análise , Destilação , Limoneno , Monoterpenos/análise , Odorantes/análise , Óleos Voláteis/análise , Plantas Medicinais/química , Plantas Medicinais/fisiologia , Sesquiterpenos de Germacrano/análise , Temperatura , Terpenos/análise , Compostos Orgânicos Voláteis/análise
8.
Braz. arch. biol. technol ; Braz. arch. biol. technol;56(3): 513-519, May-June 2013. ilus, tab
Artigo em Inglês | LILACS | ID: lil-679199

RESUMO

This work investigates the antimicrobial activity of the Schinus molle L. leaves extracts obtained under supercritical conditions using carbon dioxide and co-solvents. Antimicrobial qualitative evaluation was carried out through the bioautography technique and the microorganisms studied were Staphylococcus aureus, Pseudomonas aeruginosas, Escherichia coli, Micrococcus luteus, and Salmonella choleraesuis. The supercritical fluid extraction was carried out in a pilot scale equipment using carbon dioxide modified by the addition of co-solvents, such as ethanol and water at 150 bar and 333 K. A mathematical modeling of the process was also performed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA