Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Arthroplasty ; 37(3): 431-437.e3, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34906660

RESUMO

BACKGROUND: We conducted a randomized controlled trial to evaluate the effectiveness of acceptance and commitment therapy (ACT) delivered via a mobile phone messaging robot to patients who had their total hip arthroplasty or total knee arthroplasty procedures postponed due to the COVID-19 pandemic. METHODS: Ninety patients scheduled for total hip arthroplasty or total knee arthroplasty who experienced surgical delay due to the COVID-19 pandemic were randomized to the ACT group, receiving 14 days of twice daily automated mobile phone messages, or the control group, who received no messages. Minimal clinically important differences (MCIDs) in preintervention and postintervention patient-reported outcome measures were utilized to evaluate the intervention. RESULTS: Thirty-eight percent of ACT group participants improved and achieved MCID on the Patient-Reported Outcome Measure Information System Physical Health compared to 17.5% in the control group (P = .038; number needed to treat [NNT] 5). For the joint-specific Hip Disability and Osteoarthritis Outcome Score Joint Replacement and Knee Disability and Osteoarthritis Outcome Score Joint Replacement (KOOS JR), 24% of the ACT group achieved MCID compared to 2.5% in the control group (P = .004; NNT 5). An improvement in the KOOS JR was found in 29% of the ACT group compared to 4.2% in the control group (P = .028; NNT 5). Fourteen percent of the ACT group participants experienced a clinical important decline in the KOOS JR compared to 41.7% in the control group (P = .027; NNT 4). CONCLUSION: A psychological intervention delivered via a text messaging robot improved physical function and prevented decline in patient-reported outcome measures in patients who experienced an unexpected surgical delay during the COVID-19 pandemic. LEVEL OF EVIDENCE: 1.


Assuntos
Terapia de Aceitação e Compromisso , Artroplastia de Quadril , COVID-19 , Telefone Celular , Osteoartrite do Joelho , Humanos , Osteoartrite do Joelho/cirurgia , Pandemias , SARS-CoV-2
2.
J Arthroplasty ; 35(12): 3758-3764, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32888750

RESUMO

BACKGROUND: Spinopelvic pathology has been identified as a potential risk factor for instability after total hip arthroplasty. Spinopelvic radiographic parameters used to diagnose spinopelvic disease may also impact optimal cup placement. The purpose of this study was to assess the arthroplasty surgeon accuracy in making spinopelvic measurements. METHODS: Five fellowship-trained or in-training arthroplasty surgeons reviewed 44 lateral lumbar radiographs in two sessions. All evaluators were instructed how to perform measurements but had little experience in doing so. Traditional measurements included the pelvic tilt (PT), pelvic incidence (PI), and sacral slope (SS), and novel measurements included the acetabular ante-inclination (AI) and pelvic femoral angle. Surgeon measurements were compared with those made by experienced engineers. intraclass coefficients (ICCs) were calculated and interpreted. RESULTS: The interobserver reliability for 4 of 5 of the spinopelvic parameters was good to excellent (ICC >0.75) with the highest reliability seen for PI measurement (ICC = 0.939). Only moderate interobserver reliability was observed for AI measurement (ICC = 0.559). Intraobserver reliability was the highest for the PI and SS, ranging from moderate to good (ICC, 0.718 to 0.896). The lowest intraobserver reliability was seen for the AI (ICC range, 0.026 to 0.545) and pelvic femoral angle (ICC range, 0.035 to 0.828). Surgeon measurements of PT and SS were compared with engineer measurements with extremely poor correlation observed (ICC <0 for all). CONCLUSION: Surgeon intraobserver and interobserver reliability in making novel radiographic measurements was low compared with traditional radiographic measurements. Surgeon reliability in making traditional measurements of the PT and SS was very poor compared with experienced assessors using software-based measurements.


Assuntos
Artroplastia de Quadril , Acetábulo , Humanos , Radiografia , Reprodutibilidade dos Testes , Sacro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA