Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
BMC Vet Res ; 8: 87, 2012 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-22726641

RESUMO

BACKGROUND: Understanding normal gait requires allowing for variations in normal patterns by the sex, age, and species in question. Therefore, the aim of this study was to evaluate kinetic and temporospatial parameters in clinically healthy sheep from three different age groups with a pressure-sensing walkway. The sheep were judged to be healthy based on the results of complete physical and orthopaedic examinations and had no history of lameness. Twenty-one clinically healthy female Santa Ines sheep were divided into three groups: G1 - seven animals, aged from 8 to 12 months and weighing 19.5-33 kg; G2 - seven individuals, aged from 2 to 4 years and weighing 26.5-42 kg; and G3 - seven sheep, aged more than 5 years and weighing 37.3-45 kg. The animals were examined from two directions: first on the left side and then on the right side of the handler. The data from the first five valid trials in each direction were collected for each sheep and analysed using the designated software. A trial was considered valid if the sheep walked within the correct velocity (1.1-1.3 m/s) and acceleration (from -0.15 to 0.15 m/s2) ranges. The peak vertical force (PVF), vertical impulse (VI), gait cycle time, stance time, swing time, stride length, and the percentage body weight distribution among the four limbs were determined. RESULTS: No significant differences were observed, in either the forelimbs or the hind limbs, between the left and right sides or between the two directions for any of the variables. No significant temporospatial differences were found among the groups. Significant PVF (%BW) differences were observed in the forelimbs (G1>G3) and hind limbs (G1>G3), and significant VI differences were observed in the forelimbs (G1>G3). CONCLUSIONS: Young healthy sheep differ from older sheep in the vertical forces they create when walking at the same velocity on a pressure-sensing walkway.


Assuntos
Envelhecimento/fisiologia , Marcha/fisiologia , Ovinos/fisiologia , Caminhada/fisiologia , Animais , Fenômenos Biomecânicos , Feminino , Membro Anterior/fisiologia , Membro Posterior/fisiologia , Pressão
2.
J Vet Dent ; 27(4): 212-21, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21322428

RESUMO

This study aimed to develop a plate to treat fractures of the mandibular body in dogs and to validate the project using finite elements and biomechanical essays. Mandible prototypes were produced with 10 oblique ventrorostral fractures (favorable) and 10 oblique ventrocaudal fractures (unfavorable). Three groups were established for each fracture type. Osteosynthesis with a pure titanium plate of double-arch geometry and blocked monocortical screws of free angulation were used. The mechanical resistance of the prototype with unfavorable fracture was lower than that of the favorable fracture. In both fractures, the deflection increased and the relative stiffness decreased proportionally to the diminishing screw number The finite element analysis validated this plate study, since the maximum tension concentration observed on the plate was lower than the resistance limit tension admitted by the titanium. In conclusion, the double-arch geometry plate fixed with blocked monocortical screws has sufficient resistance to stabilize oblique fractures, without compromising mandibular dental or neurovascular structures.


Assuntos
Placas Ósseas/veterinária , Técnicas de Fixação da Arcada Osseodentária/veterinária , Fraturas Mandibulares/veterinária , Animais , Fenômenos Biomecânicos , Placas Ósseas/normas , Cadáver , Simulação por Computador , Análise do Estresse Dentário/veterinária , Cães , Análise de Elementos Finitos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/veterinária , Imageamento Tridimensional , Técnicas de Fixação da Arcada Osseodentária/instrumentação , Modelos Lineares , Masculino , Fraturas Mandibulares/diagnóstico , Fraturas Mandibulares/cirurgia , Resistência à Tração , Tomografia Computadorizada por Raios X/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA