Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29566882

RESUMO

INTRODUCTION AND OBJECTIVE: Auditory steady state responses to continuous amplitude modulated tones at rates between 70 and 110Hz, have been proposed as a feasible alternative to objective frequency specific audiometry in cochlear implant subjects. The aim of the present study is to obtain physiological thresholds by means of auditory steady-state response in cochlear implant patients (Clarion HiRes 90K), with acoustic stimulation, on free field conditions and to verify its biological origin. METHODS: 11 subjects comprised the sample. Four amplitude modulated tones of 500, 1000, 2000 and 4000Hz were used as stimuli, using the multiple frequency technique. The recording of auditory steady-state response was also recorded at 0dB HL of intensity, non-specific stimulus and using a masking technique. RESULTS: The study enabled the electrophysiological thresholds to be obtained for each subject of the explored sample. There were no auditory steady-state responses at either 0dB or non-specific stimulus recordings. It was possible to obtain the masking thresholds. A difference was identified between behavioral and electrophysiological thresholds of -6±16, -2±13, 0±22 and -8±18dB at frequencies of 500, 1000, 2000 and 4000Hz respectively. CONCLUSIONS: The auditory steady state response seems to be a suitable technique to evaluate the hearing threshold in cochlear implant subjects.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva/diagnóstico , Perda Auditiva/cirurgia , Estimulação Acústica , Adolescente , Audiometria , Criança , Feminino , Humanos , Masculino , Adulto Jovem
2.
Acta Otorrinolaringol Esp ; 62(3): 173-80, 2011.
Artigo em Espanhol | MEDLINE | ID: mdl-21208606

RESUMO

INTRODUCTION AND OBJECTIVES: The aim of this study was to examine the efficiency of the averaging technique for estimating multiple auditory steady state responses in normal hearing subjects and to provide quantifiable stopping criteria at near-threshold intensities. METHODS: Multiple amplitude-modulated (89-115 Hz) tones (500, 1,000, 2,000 and 4,000 Hz) were simultaneously presented to both ears at a fixed intensity of 40 dB HL. A total of 128 data epochs were averaged (23.9 minutes). RESULTS: The results showed that "classic" ensemble averaging, although accurate and time-efficient in most cases, could not extract all near-threshold MSSR from noise, even after recording a considerable number of sweeps. The present study also proposed a different approach to evaluate the background noise based on evaluating the mean of the variance close to the signal. CONCLUSIONS: The study proposed quantitative parameters to establish stopping criteria during auditory steady-state recordings.


Assuntos
Audiometria de Resposta Evocada/métodos , Limiar Auditivo , Potenciais Evocados Auditivos , Estimulação Acústica , Adulto , Audiometria de Tons Puros/métodos , Feminino , Humanos , Masculino , Ruído , Valores de Referência , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA