Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Biomater Adv ; 154: 213645, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37806213

RESUMO

Cardiovascular stenting is the most widely used therapy to treat coronary artery disease caused by partial or total obstruction of the artery due to atherosclerotic plaque formation, with potentially fatal effects. There are different types of stents: bare metal stents, drug-eluting stents, bioabsorbable stents and dual therapy stents. However, they can lead to long-term complications, such as in-stent restenosis and late thrombosis. To reduce these adverse effects, research has focused on biodegradable metallic stents, since they retain the mechanical properties necessary to contain the injured artery while it is being repaired and, once their function has been fulfilled, the stent degrades without altering the system or compromising the patient's health. In this work we have evaluated the biological response of the degradation products of a bare Mg based biomaterial surface-modified by the plasma electrolytic oxidation (PEO) method on vascular tissue cells, hemocompatibility and inflammatory response. The results obtained are compatible with a biosafe material for future use as a cardiovascular implant, but it is necessary to continue with in vivo and mechanical properties tests to ensure and guarantee its use. SIGNIFICANCE STATEMENT: The development of fully bioresorbable stents is a promising alternative for the management of coronary artery disease without causing long-term problems at the implantation site. In this work, the hematological and immunological biocompatibility of bare Mg modified superficially by plasma electrolytic oxidation (PEO-Mg) was evaluated by in vitro and ex vivo assays. PEO-Mg was found to be compatible with blood and immune components surrounding the implantation site with no signs of toxicity to endothelial cells, macrophages, and arterial tissue. In addition, degradation products of PEO-Mg are eliminated by phagocytosis. However, an in-depth study of the physical and mechanical properties and in vivo biocompatibility must be carried out for its future use as a biomedical implant.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Humanos , Magnésio , Doença da Artéria Coronariana/terapia , Células Endoteliais , Stents Farmacológicos/efeitos adversos , Stents/efeitos adversos
2.
Crit Rev Biomed Eng ; 49(1): 51-65, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34347987

RESUMO

Titanium dioxide nanotubes combine the geometrical properties of a tubular structure with the physico-chemical properties of TiO2. The nanotubes improve the surface characteristics of a material such as titanium, which possesses high mechanical resistance, and low density, enhancing its use for biomedical devices. The nanotubular layer increases the device's interaction with cells. In this paper, we discuss various aspects of the anodizing technique to obtain ordered nanotubes and careful control of the process parameters to obtain highly ordered TiO2 nanotubes. Also, we review the biological activity of TiO2 nanotubes, the effect of nanotube size on bioactivity, and the antibacterial effect of TiO2 nanotubes without doping. Finally, novel applications of TiO2 nanotubes employed as a biomaterial are discussed.


Assuntos
Nanotubos , Antibacterianos/farmacologia , Materiais Biocompatíveis , Propriedades de Superfície , Titânio
3.
J Biomed Mater Res A ; 109(1): 104-121, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32441468

RESUMO

Nanotubular structures were produced on a commercially pure titanium surface by anodization in an aqueous electrolyte that contained carboxymethyl cellulose and sodium fluoride. The internal diameters obtained were about 100, 48, and 9.5 nm, respectively. Several heat treatments at 200, 350, and 600°C were made to produce nanotubes with different titanium dioxide polymorphs (anatase, rutile). All tested surfaces were superhydrophilic, this behavior was maintained after at least 30 days, regardless of the heat treatment. Although in previous works the nanotube features effect on the bacteria behavior had been studied; this item still unclear. For the best of our knowledge, the effect of small internal diameters (about 10 nm) with and without heat treatment and with and without ultraviolet (UV) irradiation on the bacteria strains comportment has not been reported. From our results, both the internal diameter and the postanodized treatments have an effect on the bacteria strains comportment. All nanotubular coatings UV treated and heat treated at 350 and 600°C; despite they have different inner diameters, inhibit the bacteria growth of both Staphylococcus aureus and Pseudomonas aeruginosa strains. The nanotubular coatings obtained at 20 V and heat treated at 350°C produced the lower bacteria adhesion against both strains evaluated.


Assuntos
Antibacterianos/farmacologia , Carboximetilcelulose Sódica/química , Nanotubos , Titânio/farmacologia , Aderência Bacteriana , Eletrólitos , Testes de Sensibilidade Microbiana , Pseudomonas aeruginosa/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos , Propriedades de Superfície , Raios Ultravioleta
4.
Bioinorg Chem Appl ; 2020: 8891069, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33376478

RESUMO

Silver nanoparticles (AgNPs) have been widely employed or incorporated into different materials in biological application, due to their antibacterial properties. Therefore, antimicrobial capacity and cytotoxicity have been highly studied. However, most of these reports do not consider the possible corrosion of the nanomaterials during their exposure to atmospheric conditions since AgNPs undergo a transformation when they come in contact with a particular environment. Derived from this, the functionality and properties of the nanoparticles could decrease noticeably. The most common silver corrosion process occurs by the interaction of AgNPs with sulfur species (H2S) present in the atmospheric air, forming a corrosion layer of silver sulfide around the AgNPs, thus inhibiting the release of the ions responsible for the antimicrobial activity. In this work, AgNPs were synthesized using two different methods: one of them was based on a plant extract (Brickellia cavanillesii), and the other one is the well-known method using sodium borohydride (NaBH4). Chemical stability, corrosion, antibacterial activity, and toxic activity were evaluated for both sets of prepared samples, before and after exposition to atmospheric air for three months. The structural characterization of the samples, in terms of crystallinity, chemical composition, and morphology, evidenced the formation of link structures with nanobridges of Ag2S for non- "green" AgNPs after the air exposition and the intact preservation of silver core for the "green" sample. The antibacterial activity showed a clear improvement in the antimicrobial properties of silver in relation to the "green" functionalization, particle size control, and size reduction, as well as the preservation of the properties after air exposition by the effective "green" protection. The cytotoxicity effect of the different AgNPs against mononuclear cells showed a notable increment in the cell viability by the "green" functionalization.

5.
J Mater Sci Mater Med ; 28(11): 169, 2017 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-28956201

RESUMO

Surface characteristics can mediate biological interaction improving or affecting the tissue integration after implantation of a biomaterial. Features such as topography, wettability, surface energy and chemistry can be key determinants for interactions between cells and materials. Plasma electrolytic oxidation (PEO) is a technique used to control this kind of parameters by the addition of chemical species and the production of different morphologies on the surfaces of titanium and its alloys. With the purpose to improve the biological response, surfaces of c.p titanium and Ti6Al4V were modified by using PEO. Different electrolytes, voltages, current densities and anodizing times were tested in order to obtain surfaces with different characteristics. The obtained materials were characterized by different techniques such as X-ray diffraction (XRD), scanning electron microscopy (SEM) and glow discharge optical emission spectroscopy (GDOES). Wettability of the obtained surfaces were measured and the corresponding surface energies were calculated. Superhydrophilic surfaces with contact angles of about 0 degrees were obtained without any other treatment but PEO and this condition in some cases remains stable after several weeks of anodizing; crystal phase composition (anatase-rutile) of the anodic surface appears to be critical for obtaining this property. Finally, in order to verify the biological effect of these surfaces, osteoblast were seeded on the samples. It was found that cell behavior improves as SFE (surface free energy) and coating porosity increases whereas it is affected negatively by roughness. Techniques for surface modification allow changes in the coatings such as surface energy, roughness and porosity. As a consequence of this, biological response can be altered. In this paper, surfaces of c.p Ti and Ti6Al4V were modified by using plasma electrolytic oxidation (PEO) in order to accelerate the cell adhesion process.


Assuntos
Materiais Revestidos Biocompatíveis/síntese química , Eletrólitos/química , Galvanoplastia/métodos , Alicerces Teciduais/química , Titânio/química , Ligas , Células Cultivadas , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Humanos , Teste de Materiais , Osteoblastos/citologia , Osteoblastos/efeitos dos fármacos , Osteoblastos/fisiologia , Oxirredução , Propriedades de Superfície , Titânio/farmacologia , Molhabilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA