Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Braz Oral Res ; 37: e059, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37341232

RESUMO

The aim of this study was to compare the quantification of hard-tissue debris by using micro-computed tomography (micro-CT) and nano-focus computed tomography (nano-CT) after root canal instrumentation. Ten mandibular molars containing an isthmus in the mesial root were scanned in a SkyScan 1172 micro-CT device with a voxel size of 12.8 µm and in a NanoTom nano-CT device with 5.5 µm. The mesial root canals were irrigated with 5 mL of saline solution at the orifice level, instrumented with Reciproc R25 files and a second scanning was performed by micro-CT and nano-CT devices for post-instrumentation images. DataViewer software was used for registering the pre- and post-operative micro-CT and nano-CT images. The root canal and the debris were segmented for quantitative analysis of the volume of the canal and volume of debris using CTAn software. Statistical analysis was performed using the T test for comparison between volume of the canal after instrumentation and volume of debris in both image modalities. The level of significance was set at p < 0.05. Nano-CT images showed higher values of debris when compared with micro-CT (p < 0.05) after root canal instrumentation. No difference was observed between the volume of the root canal after instrumentation in the two imaging methods used (p > 0.05). Nano-CT technology can be recommended as a more precise method for quantitative analysis of hard-tissue debris. Moreover, in Endodontic research it is a promising method, as it is capable of providing higher spatial and contrast resolution, faster scanning and higher image quality.


Assuntos
Cavidade Pulpar , Tratamento do Canal Radicular , Humanos , Cavidade Pulpar/diagnóstico por imagem , Microtomografia por Raio-X , Dente Molar/diagnóstico por imagem , Período Pós-Operatório
2.
Braz. oral res. (Online) ; 37: e059, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1439753

RESUMO

Abstract The aim of this study was to compare the quantification of hard-tissue debris by using micro-computed tomography (micro-CT) and nano-focus computed tomography (nano-CT) after root canal instrumentation. Ten mandibular molars containing an isthmus in the mesial root were scanned in a SkyScan 1172 micro-CT device with a voxel size of 12.8 µm and in a NanoTom nano-CT device with 5.5 µm. The mesial root canals were irrigated with 5 mL of saline solution at the orifice level, instrumented with Reciproc R25 files and a second scanning was performed by micro-CT and nano-CT devices for post-instrumentation images. DataViewer software was used for registering the pre- and post-operative micro-CT and nano-CT images. The root canal and the debris were segmented for quantitative analysis of the volume of the canal and volume of debris using CTAn software. Statistical analysis was performed using the T test for comparison between volume of the canal after instrumentation and volume of debris in both image modalities. The level of significance was set at p < 0.05. Nano-CT images showed higher values of debris when compared with micro-CT (p < 0.05) after root canal instrumentation. No difference was observed between the volume of the root canal after instrumentation in the two imaging methods used (p > 0.05). Nano-CT technology can be recommended as a more precise method for quantitative analysis of hard-tissue debris. Moreover, in Endodontic research it is a promising method, as it is capable of providing higher spatial and contrast resolution, faster scanning and higher image quality.

3.
Restor Dent Endod ; 47(1): e2, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35284328

RESUMO

Objectives: This study investigated the impact of micro-computed tomography (micro-CT)-based voxel size on the analysis of material/dentin interface voids and thickness of different endodontic cements. Materials and Methods: Following root-end resection and apical preparation, maxillary premolars were filled with mineral trioxide aggregate (MTA), Biodentine, and intermediate restorative material (IRM) (n = 24). The samples were scanned using micro-CT (SkyScan 1272; Bruker) and the cement/dentin interface and thickness of materials were evaluated at voxel sizes of 5, 10, and 20 µm. Analysis of variance and the Tukey test were conducted, and the degree of agreement between different voxel sizes was evaluated using the Bland and Altman method (p < 0.05). Results: All materials showed an increase in thickness from 5 to 10 and 20 µm (p < 0.05). When evaluating the interface voids, materials were similar at 5 µm (p > 0.05), while at 10 and 20 µm Biodentine showed the lowest percentage of voids (p < 0.05). A decrease in the interface voids was observed for MTA and IRM at 20 µm, while Biodentine showed differences among all voxel sizes (p < 0.05). The Bland-Altman plots for comparisons among voxel sizes showed the largest deviations when comparing images between 5 and 20 µm. Conclusions: Voxel size had an impact on the micro-CT evaluation of thickness and interface voids of endodontic materials. All cements exhibited an increase in thickness and a decrease in the void percentage as the voxel size increased, especially when evaluating images at 20 µm.

4.
Aust Endod J ; 47(3): 631-638, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34097337

RESUMO

The aim of this study was to compare the efficacy of UAI with ESI, sonic activation with Eddy® and syringe irrigation in removing debris, and dentin removal during canal irrigation. Twenty-four mandibular molars containing isthmus type V and with a mean curvature of 32.5° were instrumented and divided into three groups for final irrigation: UAI with ESI, sonic activation with Eddy and syringe irrigation. The samples were scanned in a SkyScan 1172 micro-CT device for pre-, post-instrumentation and post-irrigation images and analysis of dentin removal. Statistical analysis was performed using Wilcoxon, Kruskal-Wallis and Dunn tests. UAI and sonic activation significantly improved debris removal (P < 0.05). No significant difference was observed regarding dentin removal between the groups (P > 0.05), although higher values were found for UAI. Sonic activation with Eddy® showed to be an effective and safe device since it was able to remove debris without causing damage to the canal walls.


Assuntos
Projetos de Pesquisa , Seringas , Dentina , Microtomografia por Raio-X
5.
Imaging Sci Dent ; 50(2): 161-168, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32601591

RESUMO

PURPOSE: The aim of this study was to evaluate the influence of voxel size and different post-processing algorithms on the analysis of dental materials using micro-computed tomography (micro-CT). MATERIALS AND METHODS: Root-end cavities were prepared in extracted maxillary premolars, filled with mineral trioxide aggregate (MTA), Biodentine, and Intermediate Restorative Material (IRM), and scanned using micro-CT. The volume and porosity of materials were evaluated and compared using voxel sizes of 5, 10, and 20 µm, as well as different software tools (post-processing algorithms). The CTAn or MeVisLab/Materialise 3-matic software package was used to perform volume and morphological analyses, and the CTAn or MeVisLab/Amira software was used to evaluate porosity. Data were analyzed using 1-way ANOVA and the Tukey test (P<0.05). RESULTS: Using MeVisLab/Materialise 3-matic, a consistent tendency was observed for volume to increase at larger voxel sizes. CTAn showed higher volumes for MTA and IRM at 20 µm. Using CTAn, porosity values decreased as voxel size increased, with statistically significant differences for all materials. MeVisLab/Amira showed a difference for MTA and IRM at 5 µm, and for Biodentine at 20 µm. Significant differences in volume and porosity were observed in all software packages for Biodentine across all voxel sizes. CONCLUSION: Some differences in volume and porosity were found according to voxel size, image-processing software, and the radiopacity of the material. Consistent protocols are needed for research evaluating dental materials.

6.
J Mater Sci Mater Med ; 31(2): 14, 2020 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-31965336

RESUMO

The aim of this study was to evaluate volumetric and morphological stability of 3 root-end filling materials in addition to porosity and interface voids, using micro-computed tomography (µCT) in high resolution and a highly accurate approach for image analysis. Following root-end resection and apical preparation, two-rooted maxillary premolars were divided into three groups, according to the filling materials: White MTA Angelus, Biodentine, and IRM. Samples were scanned by µCT at 5 µm after the setting time and at time intervals of 7 and 30 days after immersion in phosphate-buffered saline (PBS). Volumetric and morphological changes besides material porosity and interface voids were evaluated by comparing initial values and those obtained after immersion. Data were analyzed statistically, using ANOVA and t-tests (α = 0.05). All materials showed volumetric stability. Regarding the morphological changes, Biodentine had a significant thickness reduction after storage in PBS when compared with MTA. Biodentine also showed an increase in porosity, as well as in percentage and thickness of voids after 30 days of immersion. In conclusion, µCT in high resolution and an accurate image analysis approach may be used to evaluate morphological changes of endodontic materials. Although Biodentine showed suitable adaptability and lower values of porosity than MTA, after PBS immersion there was a dimensional reduction of this material, besides an increase in porosity and interface voids.


Assuntos
Materiais Dentários/química , Teste de Materiais/métodos , Microtomografia por Raio-X , Restauração Dentária Permanente , Raiz Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA