Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Coluna/Columna ; 16(1): 29-32, Jan.-Mar. 2017. tab
Artigo em Inglês | LILACS | ID: biblio-840149

RESUMO

ABSTRACT Objective: The objective of this study is to relate the use of intraoperative electromyography with surgical time, proper placement of screws, type of curve and time spent per screw in idiopathic scoliosis correction surgery in a group of surgeons from Belo Horizonte. This study used the database of protocol evaluation of patients operated in the service, and separately analyzed the results of motor and somatosensory potentials. Methods: Retrospective study of 80 patients undergoing surgery for correction of idiopathic scoliosis between December 2008 and January 2015. A single group of Belo Horizonte spine surgeons performed the intraoperative electromyographic (EMG) monitoring. EMG was performed with stimulation of pedicle screws in patients undergoing instrumentation with pedicle screws as fixation elements. Results: The sample consisted of 85% females (mean age 17 years) and 37.5% of cases had classification type 1AN of Lenke. Of the total surgical cases, 60% had EMG changes. Of the total cases analyzed, 66.3% were true positives for the result. Conclusion: Intraoperative monitoring with EMG is a very important tool for the surgical treatment of patients with scoliosis undergoing instrumentation with pedicle screws. It enables to check if the screw is located on the correct path, helping to decrease the error rate and providing corrections to the surgical approach through a change of strategies. Moreover, it contributes to decrease the time to screw positioning and the total surgical time.


RESUMO Objetivo: O objetivo deste estudo é relacionar a utilização da eletromiografia intraoperatória com tempo cirúrgico, posicionamento dos parafusos, tipo de curva e tempo por parafuso em cirurgias de correção de escoliose idiopática, em um grupo de cirurgiões de Belo Horizonte. Este trabalho utilizou o banco de dados de avaliação do protocolo de pacientes operados no serviço, e analisou separadamente os resultados do potencial motor e somatossensorial. Métodos: Estudo retrospectivo de 80 pacientes submetidos a tratamento cirúrgico para correção de escoliose idiopática no período de dezembro de 2008 e janeiro de 2015. Foi realizada a monitorização eletromiográfica (EMG) intraoperatória por um único grupo de cirurgiões de coluna de Belo Horizonte. Foi realizada EMG com estimulação dos parafusos pediculares nos pacientes submetidos à instrumentação com parafusos pediculares como elementos de fixação. Resultados: A amostra foi constituída por 85% sendo indivíduos do sexo feminino (média de idade de 17 anos) e 37,5% dos casos tinham classificação do tipo 1AN de Lenke. Do total de casos cirúrgicos, 60% apresentaram alteração EMG. Do casos analisados, 66,3% eram verdadeiros positivos para o resultado. Conclusão: A monitorização intraoperatória com EMG é uma ferramenta importante para o tratamento cirúrgico de pacientes com escoliose submetidos à instrumentação com parafusos pediculares. É possível verificar se o parafuso está localizado no trajeto correto, contribuindo para diminuição do índice de erros e propiciando correções da abordagem cirúrgica, com a mudança de estratégias. Além disso, contribui diretamente para a redução de tempo de posicionamento do parafuso e do tempo cirúrgico total.


RESUMEN Objetivo: El objetivo de este estudio es relacionar el uso de la electromiografía intraoperatoria con el tiempo quirúrgico, la colocación de los tornillos, el tipo de curva y el tiempo por tornillo en la cirugía de corrección de la escoliosis idiopática en un grupo de cirujanos de Belo Horizonte. Este trabajo utilizó la base de datos de evaluación de protocolos de los pacientes operados en el servicio y analizó los resultados de los potenciales motor y somatosensorial por separado. Métodos: Estudio retrospectivo de 80 pacientes que se sometieron a tratamiento quirúrgico para la corrección de la escoliosis idiopática entre diciembre de 2008 y enero de 2015. Un solo grupo de cirujanos de columna de Belo Horizonte realizó la monitorización electromiográfica (EMG) intraoperatoria. Se realizó EMG con la estimulación de los tornillos pediculares en pacientes sometidos a la instrumentación con tornillos pediculares como elementos de fijación. Resultados: La muestra consistió en 85% de mujeres (edad media de 17 años) y el 37,5% de los casos tenía clasificación del tipo 1AN de Lenke. Del total de los casos quirúrgicos, el 60% tenía cambio EMG. De los casos analizados, el 66,3% fueron verdaderos positivos para el resultado. Conclusión: La monitorización intraoperatoria con EMG es una herramienta importante para el tratamiento quirúrgico de los pacientes con escoliosis sometidos a la instrumentación con tornillos pediculares. Esto permite comprobar si el tornillo se encuentra en la trayectoria correcta, lo que ayuda a disminuir la tasa de errores y favorece correcciones del abordaje quirúrgico, con el cambio de las estrategias. Por otra parte, contribuye directamente a la reducción del tiempo de posicionamiento del tornillo y del tiempo quirúrgico total.


Assuntos
Humanos , Feminino , Coluna Vertebral , Eletromiografia/métodos , Parafusos Pediculares , Escoliose/cirurgia
2.
Coluna/Columna ; 9(3): 265-270, jul.-set. 2010. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-570578

RESUMO

OBJETIVO: Comparar a rigidez de um sistema de fixação pedicular composto por parafusos pediculares poliaxiais de travamento tipo Dytech® com outro composto por parafusos pediculares poliaxiais com travamento do tipo Lock 1®, submetidos a forças de compressão. MÉTODOS: A amostra utilizada para avaliar os sistemas de fixação respeitou as regras do padrão formulado pela American Society for Testing Materials (ASTM) no ensaio F1717-04. Os modelos foram divididos em: Grupo 1, composto pelos ensaios de parafusos poliaxiais com sistema Dytech® de travamento, e o Grupo 2, formado por parafusos poliaxiais com travamento tipo Lock 1®. Foram testados três conjuntos completos montados. Cada sistema foi testado uma única vez por ser esse um ensaio destrutivo. O instrumental implantado foi produzido com titânio de mesma origem. Os grupos experimentais foram submetidos a testes mecânicos na máquina universal de ensaios EMIC, modelo EMIC DL 10000®. RESULTADOS: Os resultados de compressão nas amostras do Grupo 1 tiveram uma carga máxima média de 967,17 N e carga de escoamento média de 804,71 N. Nas amostras do Grupo 2 tivemos uma carga máxima média de 906,04 N e carga de escoamento média de 834,56 N. A respeito da integridade dos instrumentais metálicos usados, não foi observado nenhum tipo de escorregamento ou soltura de porcas, parafusos ou outros componentes. CONCLUSÃO: O sistema de parafusos poliaxiais com travamento tipo Dytech® apresentou valores de rigidez maiores, enquanto o sistema de parafusos com travamento tipo Lock 1® mostrou deslocamento máximo maior.


OBJECTIVE: To compare rigidity of a pedicle fixation system composed of poliaxial pedicle screws with Dytech® lock system to one composed of poliaxial screws with Lock 1® system, submitted to compression strengths. METHODS: The sample used to evaluate the fixation systems respected the norms of the standard described by the American Society for Testing Materials (ASTM) in trial F1717-04. The models were divided into: Group 1, composed of trials using poliaxial screws with Dytech® system, and Group 2, used poliaxial screws with Lock 1® system. Three complete sets were tested. Each system was tested only once because itïs a destructive essay. The implanted components were produced with titanium coming from the same origin. The experimental groups were submitted to mechanical tests in a universal testing machine EMIC, model EMIC DL 10000®. RESULTS: The samples of Group 1 showed an average maximum charge of 967,17 N, and an average discharging load of 814,71 N. The samples of Group 2 showed an average maximum charge of 906,04 N, and an average discharging load of 834,56 N. About the integrity of the used metallic components, was not noted any kind of failure in all of them. CONCLUSION: The pofilaxial screws system with Dytech® lock has presented greater rigidity, while the Lock 1® system screws showed greater maximum displacement.


OBJETIVO: comparar la rigidez de un sistema de fijación pedicular compuesto por tornillos pediculares poliaxiales de traba tipo Dytech® con otro compuesto por tornillos pediculares poliaxiales con traba del tipo Lock 1®, sometidos a fuerzas de compresión. MÉTODOS: la muestra utilizada para evaluar los sistemas de fijación respetó las reglas del patrón formulado por la American Society for Testing Materials (ASTM) en el ensayo F1717-04. Los modelos fueron divididos en: Grupo 1, compuesto por los ensayos de tornillos poliaxiales con sistema Dytech® de traba, y el Grupo 2, formado por tornillos poliaxiales con traba tipo Lock 1®. Fueron probados tres conjuntos completos montados. Cada sistema fue probado una vez por ser ese un ensayo destructivo. El instrumental implantado fue producido con titanio del mismo origen. Los grupos experimentales fueron sometidos a pruebas mecánicas en la máquina universal de ensayos EMIC, modelo EMIC DL 10000®. RESULTADOS: los resultados de compresión en las muestras del Grupo 1 tuvieron una carga máxima promedio de 967.17 N y carga de declive promedio de 804.71 N. En las muestras del Grupo 2, tuvimos una carga máxima promedio de 906.04 N y carga de declive promedio de 834.56 N. Con respecto a la integridad de los instrumentales metálicos usados, no fue observado ningún tipo de deslizamiento o soltura de tuercas, tornillos y otros componentes. CONCLUSIÓN: el sistema de tornillos poliaxiales con traba tipo Dytech® presentó valores de rigidez mayores, mientras que el sistema de tornillos con traba tipo Lock 1® mostró un desplazamiento mayor.


Assuntos
Humanos , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Fixação de Fratura , Titânio
3.
Coluna/Columna ; 9(2): 113-118, abr.-jun. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-557018

RESUMO

OBJETIVO: comparar a rigidez de um sistema de instrumentação da coluna vertebral composto por parafusos pediculares fixos com duplo bloqueio (interno e externo) com um sistema composto por parafusos pediculares fixos com bloqueio interno único, submetidos a forças de compressão. MÉTODOS: o modelo experimental utilizado nesses testes para avaliação dos sistemas de fixação foi elaborado de acordo com as normas descritas pela American Society for Testing Materials (ASTM) no ensaio F1717-04. Foram montados dois grupos, sendo o Grupo 1 composto pelos ensaios com parafusos fixos com sistema de duplo bloqueio e o Grupo 2, com parafusos fixos com bloqueio interno único. Foram utilizados três conjuntos de hastes e parafusos para cada grupo. Cada conjunto foi submetido a um teste biomecânico. Os componentes metálicos utilizados foram todos produzidos pela mesma empresa, apresentando mesma origem em relação à matéria-prima. Os modelos experimentais foram submetidos a testes mecânicos na máquina universal de ensaios EMIC, modelo EMIC DL 10000. RESULTADOS: os resultados obtidos no ensaio de compressão nas amostras do Grupo 1 apresentaram uma carga máxima média de 2104,15 N e uma carga de escoamento média de 1882,55 N. Os resultados obtidos no ensaio de compressão nas amostras do Grupo 2 apresentaram uma carga máxima média de 1420,5 N e uma carga de escoamento média de 1314,37 N. CONCLUSÃO: o sistema de parafusos fixos com duplo bloqueio (Grupo 1) apresentou maior resistência a forças de compressão quando comparado ao sistema de parafusos com travamento interno isolado.


OBJECTIVE: to compare the rigidity of a pedicle fixation system composed of fixed pedicle screws with double locked system (internal and external) to one composed of fixed pedicle screws with single internal locked system, submitted to compression strengths. METHODS: the experimental model used to evaluate the fixation systems was constructed according to the standard described by the American Society for Testing Materials (ASTM) in trial F1717-04. The samples were divided into two groups. Group 1 was composed of tests with fixed screws with double locked system; in Group 2 fixed screws with single internal locked system were used. Three sets of rods and screws were used for each group; these sets were submitted to a biomechanical test. The metallic components were produced by the same company and with the same origin. The experimental groups were submitted to mechanical tests at the universal testing machine EMIC, model EMIC DL 10000. RESULTS: the results obtained in the compression trial in samples of Group 1 showed an average maximum charge of 2104,15 N and an average discharging load of 1882,55 N. The results obtained in the compression trial in the samples of Group 2 showed an average maximum charge of 1420,5 N and an average discharging load of 1314,37 N. CONCLUSION: the screws with double locked system (Group 1) presented greater resistance to compression strengths when compared to the screws with single internal locked system.


OBJETIVO: comparar la rigidez de un sistema de instrumentación de la columna vertebral, compuesto por tornillos pediculares fijos con duplo bloqueo (interno y externo), con un sistema compuesto por tornillos pediculares fijos con bloqueo interno único, sometidos a fuerzas de compresión. MÉTODOS: el modelo experimental utilizado en estos testes para evaluación de los sistemas de fijación fue elaborado de acuerdo con las normas descritas por la American Society for Testing Materials (ASTM) en el ensayo F1717-04. Fueron formados dos grupos, siendo el Grupo 1 compuesto por los ensayos con tornillos fijos con sistema de duplo bloqueo, y el Grupo 2, tornillos fijos con bloqueo interno único. Fueron utilizados tres conjuntos de astas y tornillos para cada grupo. Cada conjunto fue sometido a un test biomecánico. Los componentes metálicos utilizados fueron todos producidos por la misma empresa, con mismo origen en relación a la materia prima. Los modelos experimentales fueron sometidos a testes mecánicos en la máquina universal de ensayos EMIC, modelo EMIC DL 10000. RESULTADOS: los resultados obtenidos en el ensayo de compresión en las muestras del Grupo 1 tuvieron una carga máxima promedio de 2104.15 N y una carga de declive promedio de 1882.55 N. Los resultados obtenidos en el ensayo de compresión en las muestras del Grupo 2 tuvieron una carga máxima promedio de 1420.50 N y una carga de declive promedio de 1314.37 N. CONCLUSIÓN: el sistema de tornillos fijos con duplo bloqueo (Grupo 1) presentó mayor resistencia a las fuerzas de compresión cuando comparado a los tornillos con traba interna aislada.


Assuntos
Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Dor Lombar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA