RESUMO
An innovative integrated paper-based microdevice was developed for protein separation by isoelectric focusing (IEF), allowing for robust design thanks to a 3D-printed holder integrating separation channel, reservoirs, and electrodes. To reach robustness and precision, the optimization focused on the holder geometry, the paper nature, the reservoir design, the IEF medium, and various focusing parameters. A well-established and stable pH gradient was obtained on a glass-fiber paper substrate with simple sponge reservoirs, and the integration of the electrodes in the holder led to a straightforward system. The separation medium composed of water/glycerol (85/15, v/v) allowed for reducing medium evaporation while being an efficient medium for most hydrophobic and hydrophilic proteins, compatible with mass spectrometry detection for further proteomics developments. To our knowledge, this is the first report of the use of glycerol solutions as a separation medium in a paper-based microdevice. Analytical performances regarding pH gradient generation, pI determination, separation efficiency, and resolution were estimated while varying the IEF experimental parameters. The overall process led to an efficient separation within 25 min. Then, this methodology was applied to a sample composed of saliva doped with proteins. A minimal matrix effect was evidenced, underscoring the practical viability of our platform. This low-cost, versatile and robust paper-based IEF microdevice opens the way to various applications, ranging from sample pre-treatment to integration in an overall proteomic-on-a-chip device.
Assuntos
Glicerol , Focalização Isoelétrica , Papel , Proteínas , Focalização Isoelétrica/instrumentação , Focalização Isoelétrica/métodos , Proteínas/análise , Proteínas/isolamento & purificação , Glicerol/química , Glicerol/análise , Concentração de Íons de Hidrogênio , Desenho de Equipamento , Humanos , Dispositivos Lab-On-A-Chip , Saliva/química , Técnicas Analíticas Microfluídicas/instrumentação , Proteômica/métodos , Interações Hidrofóbicas e HidrofílicasRESUMO
FioAntar, FIOCRUZ's research project in Antarctica, is based on the One Health approach. FioAntar aims to generate relevant information that will help reduce the risk of future pandemics and improve the search for chemical compounds and new biological molecules. After four expeditions to Antarctica under the scope of PROANTAR, Fiocruz has identified Influenza H11N2 virus in environmental fecal samples, as well as Histoplasma capsulatum and Bacillus cereus in soil samples. In addition, in a prospective virome analysis from different lakes in the South Shetland Islands, six viral orders were described, supporting future research related to the biodiversity and viral ecology in this extreme ecosystem. Our findings of environmental pathogens of public health importance are a warning about the urgency of establishing a surveillance agenda on zoonoses in Antarctica due to the imminent risks that ongoing environmental and climate changes impose on human health across the planet. FioAntar strives to establish a comprehensive surveillance program across Antarctica, monitoring circulation of pathogens with the potential to transcend continent boundaries, thereby mitigating potential spread. For Fiocruz, Antarctica signifies a new frontier, teeming with opportunities to explore novel techniques, refine established methodologies, and cultivate invaluable knowledge.
Assuntos
Monitoramento Ambiental , Regiões Antárticas , Humanos , Monitoramento Ambiental/métodos , Saúde Única , Animais , Saúde PúblicaRESUMO
Immunization with various Leishmania species lacking centrin induces robust immunity against a homologous and heterologous virulent challenge, making centrin mutants a putative candidate for a leishmaniasis vaccine. Centrin is a calcium-binding cytoskeletal protein involved in centrosome duplication in higher eukaryotes and Leishmania spp. lacking centrin are unable to replicate in vivo and are non-pathogenic. We developed a centrin-deficient Leishmania braziliensis (LbCen-/-) cell line and confirmed its impaired survival following phagocytosis by macrophages. Upon experimental inoculation into BALB/c mice, LbCen-/- failed to induce lesions and parasites were rapidly eliminated. The immune response following inoculation with LbCen-/- was characterized by a mixed IFN-γ, IL-4, and IL-10 response and did not confer protection against L. braziliensis infection, distinct from L. major, L. donovani, and L mexicana centrin-deficient mutants. A prime-boost strategy also did not lead to a protective immune response against homologous challenge. On the contrary, immunization with centrin-deficient L. donovani (LdonCen-/-) cross-protected against L. braziliensis challenge, illustrating the ability of LdonCen-/- to induce the Th1-dominant protective immunity needed for leishmaniasis control. In conclusion, while centrin deficiency in L. braziliensis causes attenuation of virulence, and disrupts the ability to cause disease, it fails to stimulate a protective immune response.
RESUMO
This study presents the development of a polyester microplate for detecting the S-protein of the SARS-CoV-2 virus in saliva and nasopharyngeal swab samples using direct enzyme-linked immunosorbent assay (ELISA) technology. The polyester microplate was designed to contain 96 zones with a 3 mm diameter each, and a volume of 2-3 µL. The experimental conditions including reagent concentration and reaction time were optimized. The microplate image was digitized and analyzed using graphical software. The linear range obtained between protein S concentrations and pixel intensity was 0-10 µg mL-1, with a correlation coefficient of 0.99 and a limit of detection of 0.44 µg mL-1. The developed methodology showed satisfactory intraplate and interplate repeatability with RSD values lower than 7.8%. The results achieved through immunoassay performed on polyester microplates were consistent with those of the RT-PCR method and showed a sensitivity of 100% and 90% and specificity of 85.71% and 100% for saliva and nasopharyngeal samples, respectively. The proposed direct immunoassay on polyester microplates emerges as an alternative to conventional immunoassays performed on commercial polystyrene plates, given the low cost of the device, low consumption of samples and reagents, lower waste generation, and shorter analysis time. Moreover, the immunoassay has shown great potential for diagnosing COVID-19 with precision and accuracy.
Assuntos
COVID-19 , Saliva , Humanos , Glicoproteína da Espícula de Coronavírus , Colorimetria , COVID-19/diagnóstico , ImunoensaioRESUMO
This case-control study compared the clinical profile, parasite load, polymerase chain reaction positivity, and response to therapy in patients with recurrent cutaneous leishmaniasis (RCL) with primary cutaneous leishmaniasis (CL). The RCL patients had milder diseases with lower parasite loads, a lower number of lesions, and more self-healing diseases than primary CL patients.
RESUMO
Two lineages (BA.1 and BA.2) of the Omicron variant are the main ones responsible for the recent COVID-19 pandemic waves worldwide. Monitoring the prevalence and spread of these variants is important as the presence of mutations might lower the efficacy of vaccines and hinder the benefits of monoclonal antibody therapies. Although the need to screen these new lineages is emerging, genetic sequencing is scarce due to its high cost. Alternatively, we propose using reverse transcription loop-mediated isothermal amplification (RT-LAMP) to infer the prevalence of these lineages and aid in genomic surveillance in countries with limited genetic sequencing capacity. For this, we designed specific primers and tested them on a panel of 267 sequenced RNA genomes from different lineages. The test for BA.1 and its descendants showed 96.63% sensitivity, 100% specificity, and 98.85% accuracy, and the test for BA.2 and descendants showed 90.00% sensitivity, 98.85% specificity, and 98.52% accuracy. These results demonstrate the potential of RT-LAMP to be an alternative to help monitor variants, especially in countries with scarce resources.
Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Colorimetria , Pandemias , COVID-19/diagnóstico , Técnicas de Amplificação de Ácido NucleicoRESUMO
Patients with cutaneous leishmaniasis (CL) due to Leishmania braziliensis infection have an exacerbated inflammatory response associated with tissue damage and ulcer development. An increase in the rate of patients who fail therapy with pentavalent antimony has been documented. An adjuvant therapy with an anti-inflammatory drug with the potential of Leishmania killing would benefit CL patients. The aim of the present study was to investigate the contribution of peroxisome proliferator-activated receptor-γ (PPAR-γ) activation by pioglitazone in the regulation of the inflammatory response and L. braziliensis killing by monocytes. Pioglitazone is an oral drug used in the treatment of diabetes, and its main mechanism of action is through the activation of PPAR-γ, which is expressed in many cell types of the immune response. We found that activation of PPAR-γ by pioglitazone decreases the inflammatory response in CL patients without affecting L. braziliensis killing by monocytes. Our data suggest that pioglitazone may serve as an adjunctive treatment for CL caused by L. braziliensis.
Assuntos
Leishmania braziliensis , Leishmaniose Cutânea , Humanos , Leishmaniose Cutânea/tratamento farmacológico , Monócitos , PPAR gama/uso terapêutico , Pioglitazona/farmacologia , Pioglitazona/uso terapêuticoRESUMO
Despite the advance of vaccination worldwide, epidemic waves caused by more transmissible and immune evasive genetic variants of SARS-CoV-2 have sustained the ongoing pandemic of COVID-19. Monitoring such variants is expensive, as it usually relies on whole-genome sequencing methods. Therefore, it is necessary to develop alternatives that could help identify samples from specific variants. Reverse transcription loop-mediated isothermal amplification is a method that has been increasingly used for nucleic acid amplification, as it is cheaper and easier to perform when compared to other molecular techniques. As a proof of concept that can help distinguish variants, we present an RT-LAMP assay capable of detecting samples carrying a group of mutations that can be related to specific SARS-CoV-2 lineages, here demonstrated for the Variant of Concern Gamma. We tested 60 SARS-CoV-2 RNA samples extracted from swab samples and the reaction showed a sensitivity of 93.33%, a specificity of 88.89% and a kappa value of 0.822 for samples with a Ct ≤ 22.93. The RT-LAMP assay demonstrated to be useful to distinguish VOC Gamma and may be of particular interest as a screening approach for variants in countries with poor sequencing coverage.
Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , COVID-19/epidemiologia , Colorimetria/métodos , Primers do DNA , Humanos , Técnicas de Diagnóstico Molecular/métodos , Mutação , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA Viral/genética , SARS-CoV-2/genética , Sensibilidade e EspecificidadeRESUMO
Since 2020, developed countries have rapidly shared both publicly and academically relevant wastewater surveillance information. Data on SARS-CoV-2 circulation is pivotal for guiding public health policies and improving the COVID-19 pandemic response. Conversely, low- and middle-income countries, such as Latin America and the Caribbean, showed timid activities in the Wastewater-Based Epidemiology (WBE) context. In these countries, isolated groups perform viral wastewater monitoring, and the data are unevenly shared or accessible to health agencies and the scientific community. This manuscript aims to highlight the relevance of a multiparty effort involving research, public health, and governmental agencies to support usage of WBE methodology to its full potential during the COVID-19 pandemic as part of a joint One Health surveillance approach. Thus, in this study, we explored the results obtained from wastewater surveillance in different regions of Brazil as a part of the COVID-19 Wastewater Monitoring Network ANA (National Water Agency), MCTI (Ministry of Science, Technology, and Innovations) and MS (Ministry of Health). Over the epidemiological weeks of 2021 and early 2022, viral RNA concentrations in wastewater followed epidemiological trends and variations. The highest viral loads in wastewater samples were detected during the second Brazilian wave of COVID-19. Corroborating international reports, our experience demonstrated usefulness of the WBE approach in viral surveillance. Wastewater surveillance allows hotspot identification, and therefore, early public health interventions. In addition, this methodology allows tracking of asymptomatic and oligosymptomatic individuals, who are generally underreported, especially in emerging countries with limited clinical testing capacity. Therefore, WBE undoubtedly contributes to improving public health responses in the context of this pandemic, as well as other sanitary emergencies.
RESUMO
BACKGROUND: Enzyme-linked immunosorbent assays (ELISA) are generally the chosen test for Chagas disease (CD) diagnosis; however, its performance depends on the antigen preparation adsorbed to the solid phase, which may lead to false-positive results and cross-reactions. The use of chimeric recombinant antigens can overcome this limitation. Four chimeric antigens from Trypanosoma cruzi (IBMP-8.1, IBMP-8.2, IBMP-8.3 and IBMP-8.4) were developed and evaluated in phase I, II and III studies using indirect ELISA as diagnostic platform. However, peroxidase-labeled secondary anti-human IgG antibody, which is employed in indirect ELISAs, limits its use for the detection of species-specific and class-specific antibodies. To overcome this limitation, peroxidase-labeled antigens can be utilized, diagnosing both acute or chronic infection, in a species and immunoglobulin class-independent manner, through the use of a double-antigen sandwich ELISA (DAgS-ELISA). We aimed to evaluate and validate the diagnostic performance of the chimeric antigens IBMP-8.1, IBMP-8.2, IBMP-8.3 and IBMP-8.4 in the DAgS-ELISA platform. METHODOLOGY/PRINCIPAL FINDINGS: DAgS-ELISA was optimized by checkerboard titration. In phase I study, 207 positive and 205 negative samples were evaluated. Cross-reactivity to other infections was also assessed using 68 samples. The selected conditions for the tests utilized 25 ng of antigen per well and the conjugate diluted at 1:2,000 for all molecules. In the phase I study, the areas under the curve of IBMP-8.1, IBMP-8.2, IBMP-8.3 and IBMP-8.4 were 98.7%, 99.5%, 98.6% and 98.8%, respectively. Among the positive samples, IBMP-8.1 antigen classified 53 (25.6%) as false negative, IBMP-8.2, 27 (13%), IBMP-8.3, 24 (11.6%) and IBMP-8.4, 43 (20.8%), giving sensitivities of 74.4%, 87%, 88.4% and 79.2%, respectively. The only antigen that did not reach 100% specificity was IBMP-8.3, with 96.6%. IBMP-8.3 was also the only molecule to show cross-reactivity with HTLV. CONCLUSIONS/SIGNIFICANCE: DAgS-ELISA is a promising tool for immunodiagnosis, and despite the high AUC values, the performance of this assay was different from the values obtained by our group when using these antigens in the indirect ELISA, for this reason, improvements are being considered to increase the sensitivity of the DAgS-ELISA.
Assuntos
Doença de Chagas , Trypanosoma cruzi , Anticorpos Antiprotozoários , Antígenos , Antígenos de Protozoários , Doença de Chagas/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Peroxidase , Sensibilidade e Especificidade , Trypanosoma cruzi/genéticaRESUMO
BACKGROUND: Major depressive disorder (MDD) is commonly reported in patients with chronic hepatitis C (CHC); however, the factors behind the co-occurrence of these conditions have not been completely clarified yet. OBJECTIVE: We aimed to evaluate the frequency of mental disorders in CHC patients and to investigate variables associated with MDD. METHODS: CHC patients (n=151) attending a referral Centre for hepatitis were evaluated using the Mini-International Neuropsychiatry Interview and the Cut-Annoyed-Guilty-Eye (CAGE) Questionnaire. Multivariate analysis was used to evaluate independent covariates associated with current MDD. RESULTS: Seventy-six (50.3%) patients had, at least, one current psychiatric diagnosis with MDD (33.1%) being the most common. Current MDD was independently associated with age (≤50 yr.) (OR=2.57; 95%CI=1.25-5.29; P=0.01) and type 2 diabetes mellitus (OR=2.80, 95%CI=1.17-6.70; P=0.02). Cirrhosis was associated with type 2 diabetes mellitus (OR=5.09; 95%CI=1.73-15.04; P=0.03) and current alcohol abuse/dependence (OR=2.54; 95%CI=1.04-6.22; P=0.04). DISCUSSION: MDD is associated with type 2 diabetes in CHC patients. Even in the direct-acting antivirals (DAAs) era, characterized by great perspectives for the first ample cure of a chronic viral infection, we should ensure that the screening for psychiatric disorders takes place in the course of routine clinical care of patients chronically infected with hepatitis C virus.
Assuntos
Transtorno Depressivo Maior , Diabetes Mellitus Tipo 2 , Hepatite C Crônica , Hepatite C , Antivirais/uso terapêutico , Transtorno Depressivo Maior/tratamento farmacológico , Transtorno Depressivo Maior/epidemiologia , Transtorno Depressivo Maior/etiologia , Diabetes Mellitus Tipo 2/complicações , Hepatite C/tratamento farmacológico , Hepatite C Crônica/complicações , Hepatite C Crônica/tratamento farmacológico , Hepatite C Crônica/epidemiologia , HumanosRESUMO
ABSTRACT BACKGROUND: Major depressive disorder (MDD) is commonly reported in patients with chronic hepatitis C (CHC); however, the factors behind the co-occurrence of these conditions have not been completely clarified yet. OBJECTIVE: We aimed to evaluate the frequency of mental disorders in CHC patients and to investigate variables associated with MDD. METHODS: CHC patients (n=151) attending a referral Centre for hepatitis were evaluated using the Mini-International Neuropsychiatry Interview and the Cut-Annoyed-Guilty-Eye (CAGE) Questionnaire. Multivariate analysis was used to evaluate independent covariates associated with current MDD. RESULTS: Seventy-six (50.3%) patients had, at least, one current psychiatric diagnosis with MDD (33.1%) being the most common. Current MDD was independently associated with age (≤50 yr.) (OR=2.57; 95%CI=1.25-5.29; P=0.01) and type 2 diabetes mellitus (OR=2.80, 95%CI=1.17-6.70; P=0.02). Cirrhosis was associated with type 2 diabetes mellitus (OR=5.09; 95%CI=1.73-15.04; P=0.03) and current alcohol abuse/dependence (OR=2.54; 95%CI=1.04-6.22; P=0.04). DISCUSSION: MDD is associated with type 2 diabetes in CHC patients. Even in the direct-acting antivirals (DAAs) era, characterized by great perspectives for the first ample cure of a chronic viral infection, we should ensure that the screening for psychiatric disorders takes place in the course of routine clinical care of patients chronically infected with hepatitis C virus.
RESUMO CONTEXTO: O transtorno depressivo maior (TDM) é comumente detectado em pacientes com hepatite C crônica. Entretanto, fatores potencialmente associados à coocorrência destas condições não são completamente conhecidos. OBJETIVO: Avaliar a frequência de transtornos mentais em pacientes com hepatite C crônica e investigar variáveis associadas ao TDM. MÉTODOS: Pacientes com hepatite C crônica (n=151) atendidos em um centro de referência para hepatite foram avaliados usando o Mini-International Neuropsychiatry Interview e o questionário Cut-Annoyed-Guilty-Eye (CAGE). Análise multivariada foi usada para avaliar as covariáveis independentes associadas ao TDM atual. RESULTADOS: Setenta e seis (50,3%) pacientes apresentaram pelo menos um diagnóstico psiquiátrico atual; dentre eles destaca-se o TDM (33,1%). TDM atual foi independentemente associado à idade (≤50 anos) (OR=2,57; IC95% = 1,25-5,29; P=0,01) e diabetes mellitus tipo 2 (OR=2,80, IC95% = 1,17-6,70; P=0,02). Cirrose foi associada ao diabetes mellitus tipo 2 (OR=5,09; IC95% = 1,73-15,04; P=0,03) e abuso/dependência de álcool atual (OR=2,54; IC95% = 1,04-6,22; P=0,04). DISCUSSÃO: TDM está associado a diabetes tipo 2 em pacientes com hepatite C crônica. Em vigência da era dos antivirais de ação direta, caracterizada por grandes perspectivas para a primeira cura ampla de uma infecção viral crônica, devemos assegurar que a triagem dos transtornos psiquiátricos ocorra durante o atendimento clínico de rotina de pacientes com infecção crônica pelo vírus da hepatite C.
RESUMO
SARS-CoV-2 currently represents a serious global public health problem. Non-pharmaceutical intervention measures (NPIs) have been widely adopted, and the testing strategy since the beginning of the infection is the most effective tool for tracking, isolating, and minimizing transmission. The high operating costs and the need for sophisticated instrumentation related to gold standard diagnostic for COVID-19, Reverse Transcription quantitative Polymerase Chain Reaction (RT-qPCR), have highlighted the urgency and importance of developing and applying new diagnostic techniques, especially in places with scarce resources. Thus, alternative molecular tests, such as Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP), based on isothermal amplification have been used to detect SARS-CoV-2 using different protocols. The potential for field application of RT-LAMP is due to the lower cost and time and not requiring high-cost instrumentation. Here, we evaluate the colorimetric RT-LAMP to detect SARS-CoV-2 in a hospital environment and correlate its performance with tests performed in a reference laboratory. The analysis performed at the hospital showed high sensitivity (88.89%), specificity (98.55%), accuracy (95.83%), and a Cohen's kappa of 0.895. However, we achieved 100% of agreement when comparing the RT-LAMP results with the gold standard (qRT-PCR) results for samples with Ct < 30 in the hospital-based test. In addition, a similar performance was found in the field compared to the reference laboratory, corroborating the proposal to apply the test directly at point-of-care.
Assuntos
COVID-19 , SARS-CoV-2 , Colorimetria , Hospitais , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Sensibilidade e EspecificidadeRESUMO
Infection caused by the new coronavirus (SARS-CoV-2) has become a serious worldwide public health problem, and one of the most important strategies for its control is mass testing. Loop-mediated isothermal amplification (LAMP) has emerged as an important alternative to simplify the diagnostics of infectious diseases. In addition, an advantage of LAMP is that it allows for easy reading of the final result through visual detection. However, this step must be performed with caution to avoid contamination and false-positive results. LAMP performed on microfluidic platforms can minimize false-positive results, in addition to having potential for point-of-care applications. Here, we describe a polystyrene-toner (PS-T) centrifugal microfluidic device manually controlled by a fidget spinner for molecular diagnosis of COVID-19 by RT-LAMP, with integrated and automated colorimetric detection. The amplification was carried out in a microchamber with 5 µL capacity, and the reaction was thermally controlled with a thermoblock at 72 °C for 10 min. At the end of the incubation time, the detection of amplified RT-LAMP fragments was performed directly on the chip by automated visual detection. Our results demonstrate that it is possible to detect COVID-19 in reactions initiated with approximately 10-3 copies of SARS-CoV-2 RNA. Clinical samples were tested using our RT-LAMP protocol as well as by conventional RT-qPCR, demonstrating comparable performance to the CDC SARS-CoV-2 RT-qPCR assay. The methodology described in this study represents a simple, rapid, and accurate method for rapid molecular diagnostics of COVID-19 in a disposable microdevice, ideal for point-of-care testing (POCT) systems.
Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , Determinação de Ponto Final/métodos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Poliestirenos , SARS-CoV-2/isolamento & purificação , Animais , COVID-19/diagnóstico , COVID-19/genética , Teste de Ácido Nucleico para COVID-19/instrumentação , Centrifugação/instrumentação , Centrifugação/métodos , Chlorocebus aethiops , Determinação de Ponto Final/instrumentação , Humanos , Técnicas de Diagnóstico Molecular/instrumentação , Técnicas de Amplificação de Ácido Nucleico/instrumentação , SARS-CoV-2/genética , Fatores de Tempo , Células VeroRESUMO
Cardiovascular Disease (CVD) epidemiology varies significantly among Low and Middle-Income Countries. Honduras is the Central American country with the highest Ischemic Heart Disease and CVD mortality rates. The aim of this study was to assess the individual CVD risk factors and calculate Cardiovascular Risk Assessment Scores (CVRAS) from the population. Methods: A cross-sectional study in western Honduras. Estimation of CV risk was performed using Framingham, MESA, ACC/AHA-PCEs and ESC SCORE calculators. Results: 38% were male. For men and women respectively; 49% and 48% had self-reported hypertension (HTN), on measured blood pressure only 18% and 30% had normal readings. Diabetes Mellitus was reported in 19% and 22%. Tobacco use was 14% and 3%. Self-reported regular exercise was 39.9% and 25%. Obesity was diagnosed in 24% and 24%. Lipid profile; total cholesterol was ≥200 mg/dl in 63% of subjects. LDL-C was elevated (>100 mg/dl) in 74% of participants, 9% had LDL-C levels higher than 190 mg/dl. Triglycerides were high (>160 mg/dl) in 60%, of these subjects 22% were taking lipid-lowering medications. 52% reported family-history of CVD. The risk calculation for men and women respectively for each CVRAS were; AHA/ACC-PCEs high risk (score ≥ 7.5%) in 62% and 30%, FRS high risk (score ≥ 20%) 46% and 15%, MESA high risk (Score ≥ 7.5%) in 70.6% and 17.7%, ESC SCORE high risk (score ≥ 5% in 32.4% and 11.8%). Conclusions: CV risk calculations revealed higher than rates than expected with consequently reflected on higher than estimated CVRAS. This represents the first report of its kind in Honduras.
RESUMO
This study assessed the efficiency of cervical relaxation protocol using none, half or full dose (1.0 mg) of oestradiol benzoate in Dorper ewes subjected to non-surgical embryo recovery (NSER). Thirty-six pluriparous ewes received progestogen sponge (60 mg) for 9 days plus eCG administration (300 IU i.m.) 24 hr before sponge removal. Ewes were not mated and were randomly assigned to receive at 16 hr before NSER 37.5 µg d-cloprostenol i.m. and different doses of oestradiol benzoate: 0.0 mg (0EB group; n = 12); 0.5 mg (0.5EB group; n = 12) or 1.0 mg of oestradiol (1.0EB group, n = 12). All ewes received oxytocin (50 IU) i.v. 20 min before NSER, which was performed 8 days after sponge removal. Corpora lutea were counted by transrectal ultrasonography 24 hr before NSER. After procedure, the ewes were kept in natural breeding period to check their post-NSER fertility. NSER was performed in 91.7% (33/36) of the animals with overall fluid recovery efficiency over 97% (p > .05). The cervical transposing with Hegar dilator was longer (p < .05) in 0EB (4.2 ± 0.3 min) compared to 0.5EB (1.7 ± 0.3 min) and 1.0EB group (1.5 ± 0.3 min). The cervical transposing with mandrel/catheter was longer (p < .05) in 0EB (2.4 ± 0.5 min) than 1.0EB group (1.3 ± 0.5 min). Overall duration of uterine flushing was 25.4 min with structure recovery rate of 43.5%, with no difference among groups (p > .05). The post-NSER fertility was higher (p < .05) in 0.0EB (90%) than 0.5EB group (36.4%). In conclusion, NSER can be successfully performed in Dorper ewes by using a cervical relaxation protocol without oestradiol benzoate.
Assuntos
Estradiol/análogos & derivados , Carneiro Doméstico , Coleta de Tecidos e Órgãos/veterinária , Animais , Colo do Útero/efeitos dos fármacos , Transferência Embrionária/métodos , Transferência Embrionária/veterinária , Embrião de Mamíferos , Estradiol/farmacologia , Sincronização do Estro , Feminino , Fertilidade , Coleta de Tecidos e Órgãos/métodosRESUMO
Estudo transversal que buscou analisar a ocorrência de erisipela em mulheres com câncer de mama. Foi desenvolvido em um núcleo de reabilitação e incluídas, por conveniência, 84 mulheres com câncer de mama. Observou-se que 19% das participantes apresentaram sinais e sintomas de erisipela. Os sinais mais prevalentes foram hiperemia da pele, calor local e dor (100%). Além disso, observou-se que 75% das participantes com erisipela também apresentavam linfedema (p<0,005). Entre as mulheres com linfedema e erisipela, observou-se que 83,3% apresentavam o linfedema previamente ao primeiro episódio de erisipela. A prevalência de erisipela entre mulheres com câncer de mama em reabilitação, apontou que dentre os fatores predisponentes desta patologia houve associação com a presença de linfedema. Dados que justificam a inclusão de medidas de prevenção do linfedema, como hidratação do membro superior homolateral à cirurgia e evitar traumas nos cuidados prestados às mulheres com câncer de mama, prevenindo também a erisipela.
A cross-sectional study that analyzed the occurence of erysipelas in women with breast cancer. It was conducted in a rehabilitation center, and 84 women with breast cancer were included by convenience. It was observed that 19% of women had signs and symptoms of erysipelas. The most prevalent signs were skin hyperemia, local heat, and pain (100%). Moreover, 75% of participants with erysipelas also had lymphedema (p<0.005). Among women with lymphedema and erysipelas, 83.8% had the lymphedema before erysipelas. The prevalence of erysipelas among women with breast cancer in rehabilitation pointed that within the predisposing factors of this pathology, there was an association with the presence of lymphedema. This data justify the inclusion of prevention measures for lymphedema, such as hydration of the superior limb homolateral to the surgery and to avoid trauma in the care provided to women with breast cancer, also preventing erysipelas.
Assuntos
Humanos , Feminino , Neoplasias da Mama , Erisipela , Neoplasias da Mama/enfermagem , Prevenção de Doenças , LinfedemaRESUMO
Long-term heat stress (HS) induced by testicular insulation generates oxidative stress (OS) on the testicular environment; consequently activating antioxidant enzymes such as superoxide dismutase (SOD), glutathione reductase (GR) and glutathione peroxidase (GPx). The aim of this work was to immunolocalize antioxidant enzymes present in different cells within the seminiferous tubule when rams were submitted to HS. Rams were divided into control (n = 6) and treated group (n = 6), comprising rams subjected to testicular insulation for 240 h. After the testicular insulation period, rams were subjected to orchiectomy. Testicular fragments were submitted to immunohistochemistry for staining against SOD, GR and GPx enzymes. We observed immunolocalization of GPx in more cell types of the testis after HS and when compared with other enzymes. In conclusion, GPx is the main antioxidant enzyme identified in testicular cells in an attempt to maintain oxidative balance when HS occurs.
Assuntos
Glutationa Peroxidase/metabolismo , Glutationa Redutase/metabolismo , Resposta ao Choque Térmico/fisiologia , Túbulos Seminíferos/enzimologia , Superóxido Dismutase/metabolismo , Testículo/enzimologia , Animais , Antioxidantes/metabolismo , Imuno-Histoquímica/métodos , Masculino , Orquiectomia , Estresse Oxidativo/fisiologia , Túbulos Seminíferos/citologia , Ovinos , Espermátides/citologia , Espermátides/enzimologia , Espermatócitos/citologia , Espermatócitos/enzimologia , Espermatogônias/citologia , Espermatogônias/enzimologia , Testículo/citologia , Fatores de TempoRESUMO
Zika virus (ZIKV) is a current threat to global health. In most of cases, ZIKV infection has no symptoms; however in some cases, ZIKV can cause paralysis (Guillain-Barré syndrome), and in pregnant women, it can cause birth defects in infants. Rapid and accurate diagnosis can help improve disease control as well as being vital to prenatal care for women living in endemic areas. Molecular diagnostics based on isothermal amplification techniques are an excellent alternative to conventional methods of DNA amplification, such as PCR. Here, we develop and optimized a rapid and sensitive method for direct detection of ZIKV in Serum samples based on RT-LAMP and visual detection. The reaction was thermally controlled with a thermoblock for 10â¯min at 72⯰C. The results show that the use of the Bst 3.0 enzyme and an adequate optimization can further reduce the time needed for the RT-LAMP reaction to detect ZIKV. Our results demonstrate that it is possible to detect ZIKV through RT-LAMP directly from a Serum sample, without prior RNA extraction. As little as 10-3 copies of RNA in a 10⯵L reaction (20 zepto-molar) was detected by RT-LAMP from a panel of 51 Serum samples (16 samples from pregnant women and 35 samples from newborns infected with ZIKV during pregnancy). The RT-LAMP has proven to be a valuable tool for molecular diagnosis of Zika, presenting a great potential for point-of-care applications, especially in developing countries.
Assuntos
Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Infecção por Zika virus/sangue , Infecção por Zika virus/diagnóstico , Zika virus/isolamento & purificação , Feminino , Humanos , Recém-Nascido , Sistemas Automatizados de Assistência Junto ao Leito , Gravidez , Gestantes , RNA Viral/isolamento & purificação , Sensibilidade e Especificidade , Fatores de TempoRESUMO
Our understanding of mammal ecology has always been hindered by the difficulties of observing species in closed tropical forests. Camera trapping has become a major advance for monitoring terrestrial mammals in biodiversity rich ecosystems. Here we compiled one of the largest datasets of inventories of terrestrial mammal communities for the Neotropical region based on camera trapping studies. The dataset comprises 170 surveys of medium to large terrestrial mammals using camera traps conducted in 144 areas by 74 studies, covering six vegetation types of tropical and subtropical Atlantic Forest of South America (Brazil and Argentina), and present data on species composition and richness. The complete dataset comprises 53,438 independent records of 83 species of mammals, includes 10 species of marsupials, 15 rodents, 20 carnivores, eight ungulates and six armadillos. Species richness averaged 13 species (±6.07 SD) per site. Only six species occurred in more than 50% of the sites: the domestic dog Canis familiaris, crab-eating fox Cerdocyon thous, tayra Eira barbara, south American coati Nasua nasua, crab-eating raccoon Procyon cancrivorus and the nine-banded armadillo Dasypus novemcinctus. The information contained in this dataset can be used to understand macroecological patterns of biodiversity, community, and population structure, but also to evaluate the ecological consequences of fragmentation, defaunation, and trophic interactions.