Heart Lung ; 45(6): 550-556, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27639286

RESUMO

BACKGROUND: It is not yet completely known whether the 6MWT can be used to prescribe high-intensity exercise for patients with COPD. OBJECTIVE: To evaluate the ability of the six-minute walk test (6MWT) to prescribe high-intensity exercise for patients with chronic obstructive pulmonary disease (COPD). METHODS: Lung function, maximal inspiratory strength, symptoms and exercise capacity were evaluated in patients with COPD (n = 27) before and after a 12-week high-intensity exercise program. Criteria for high-intensity training were: 1) ≥75% of the 6MWT average speed; 2) American Thoracic Society/European Respiratory Society (ATS/ERS) criteria (≥60% of the maximal incremental shuttle walk test speed). RESULTS: The 6MWT showed good positive and negative predictive values (0.69 and 0.71, respectively), and accuracy (0.70), good reliability (ICC 0.70 [95%CI 0.45-0.85]) and moderate agreement (k 0.41 [95%CI 0.13-0.67]) with the ATS/ERS criteria. CONCLUSION: The 6MWT has good predictive ability and accuracy in relation to high-intensity exercise for patients with COPD.


Assuntos
Terapia por Exercício/métodos , Tolerância ao Exercício/fisiologia , Doença Pulmonar Obstrutiva Crônica/reabilitação , Teste de Caminhada/métodos , Idoso , Feminino , Seguimentos , Humanos , Masculino , Prognóstico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Reprodutibilidade dos Testes , Testes de Função Respiratória