Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
RGO (Porto Alegre) ; 70: e20220060, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1406480

RESUMO

ABSTRACT The commercial bovine bone mineral most commonly used is available in two particle sizes and studies have demonstrated contradictory results regarding bone formation volume using small or large particles. The aim of this systematic review and meta-analysis was to compare the bone formation volume and residual bovine bone volume in sinus floor augmentation using small and large particles. The following outcome measures were assessed: bone formation volume (%) and residual bovine bone particles volume (%) assessed by histomorphometric analysis. The initial screening resulted in 236 records. After removal of duplicated articles and analysis of titles, abstracts and full texts, three articles were included in the meta-analysis. The bone formation volume and residual bovine bone volume did not differ between small and large particles, with low heterogeneity of studies. The particle size of bovine bone mineral did not influence bone formation percentage; small and large particles of bovine bone graft presented similar residual bone mineral; more randomized clinical trials should be performed to completely confirm that bovine bone mineral particle size does not affect the result of sinus floor augmentation.


RESUMO O enxerto ósseo bovino comercial mais comumente utilizado está disponível em dois tamanhos de partícula, que tem demonstrado resultados contraditórios em relação à formação óssea usando partículas pequenas ou grandes. O objetivo desta revisão sistemática e meta-análise é comparar o volume de formação óssea e o volume de enxerto residual em levantamento de seio usando partículas pequenas e grandes. Os seguintes dados foram comparados: volume de formação óssea (%) e volume residual de partículas de enxerto (%) dados por análise histomorfométrica. A seleção inicial resultou em 236 artigos. Após remoção de artigos duplicados e análise dos títulos, resumos e textos completos, três artigos foram incluídos na meta-análise. Os volumes de formação óssea e de enxerto residual não diferenciam entre os tamanhos de partícula pequeno e grande, com baixa heterogeneidade dos artigos. O tamanho de partícula de enxerto ósseo bovino não influencia o percentual de formação óssea; partículas de enxerto ósseo bovino pequenas e grandes apresentaram enxerto residual similar; mais ensaios clínicos randomizados deveriam ser realizados para confirmar que o tamanho de partícula de enxerto não afeta os resultados de levantamento de seio maxilar.

2.
Sci Rep ; 9(1): 7710, 2019 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-31118474

RESUMO

The aim of this study was to evaluate the influence of boron-nitride nanotubes (BNNTs) on the properties of resin-based light-curing dental sealants (RBSs) when incorporated at different concentration. RBSs were formulated using methacrylate monomers (90 wt.% TEGDMA, 10 wt.% Bis-GMA). BNNTs were added to the resin blend at 0.1 wt.% and 0.2 wt.%. A Control group without filler was also designed. Degree of conversion, ultimate tensile strength, contact angle, surface free energy, surface roughness and color of the RBSs were evaluated for the tested materials. Their cytotoxicity and mineral deposition ability (Bioactivity) were also assessed. A suitable degree of conversion, no effect in mechanical properties and no cytotoxic effect was observed for the experimental materials. Moreover, the surface free energy and the surface roughness decreased with the addition of BNNTs. While the color analysis showed no difference between specimens containing BNNTs and the control group. Mineral deposition occurred in all specimens containing BNNTs after 7d. In conclusion, the incorporation of BNNTs may provide bioactivity to resin-based dental sealants and reduce their surface free energy.

3.
Braz Oral Res ; 33: e010, 2019 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-30892409

RESUMO

This in situ study aimed to evaluate the antibacterial and anti-demineralization effects of an experimental orthodontic adhesive containing triazine and niobium phosphate bioglass (TAT) around brackets bonded to enamel surfaces. Sixteen volunteers were selected to use intra-oral devices with six metallic brackets bonded to enamel blocks. The experimental orthodontic adhesives were composed by 75% BisGMA and 25% TEGDMA containing 0% TAT and 20% TAT. Transbond XT adhesive (TXT) was used as a control group. Ten volunteers, mean age of 29 years, were included in the study. The six blocks of each volunteer were detached from the appliance after 7 and 14 days to evaluate mineral loss and bacterial growth including total bacteria, total Streptococci, Streptococci mutans, and Lactobacilli. Statistical analysis was performed using GLM model - univariate analysis of variance for microhardness and 2-way ANOVA for bacterial growth (p<0.05). The 20% TAT adhesive caused no difference between distances from bracket and the sound zone at 10-µm deep after 7 and 14 days. After 14 days, higher mineral loss was shown around brackets at 10- to 30-µm deep for TXT and 0% TAT adhesives compared to 20% TAT. S. mutans growth was inhibited by 20% TAT adhesive at 14 days. Adhesive with 20% TAT showed lower S. mutans and total Streptococci growth than 0% TAT and TXT adhesives. The findings of this study show that the adhesive incorporated by triazine and niobium phosphate bioglass had an anti-demineralization effect while inhibiting S. mutans and total Streptococci growth. The use of this product may inhibit mineral loss of enamel, preventing the formation of white spot lesions.


Assuntos
Antibacterianos/farmacologia , Cimentos Dentários/farmacologia , Lactobacillus/efeitos dos fármacos , Nióbio/farmacologia , Óxidos/farmacologia , Fosfatos/farmacologia , Streptococcus/efeitos dos fármacos , Desmineralização do Dente/prevenção & controle , Adulto , Antibacterianos/química , Cerâmica/química , Cerâmica/farmacologia , Cimentos Dentários/química , Método Duplo-Cego , Feminino , Humanos , Masculino , Adulto Jovem
4.
Materials (Basel) ; 12(4)2019 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-30795577

RESUMO

Orthodontic adhesives with antimicrobial and remineralizing properties may be an alternative to control white spot lesions around brackets. The aim of this study is to develop an experimental orthodontic adhesive containing boron nitride nanotubes (BNNT) and alkyl trimethyl ammonium bromide (ATAB). Methacrylate (BisGMA and TEGDMA) monomers were used to formulate the adhesives. Four experimental groups were produced with the addition of 0.1 wt.% BNNT (GBNNT); 0.1 wt.% ATAB (GATAB); and 0.2 wt.% BNNT with ATAB (GBNNT/ATAB); in the control group, no fillers were added (GCtrl). The degree of conversion, cytotoxicity, softening in solvent, contact angle and free surface energy, antibacterial activity, shear bond strength, and mineral deposition were evaluated. Adhesives achieved degree of conversion higher than 50% and cell viability higher than 90%. GBNNT and GATAB adhesives exhibited reduced softening in solvent. Mean free surface energy was decreased in the GBNNT adhesive. Significant reduction in bacterial growth was observed in the GBNNT/ATAB. No statistical difference was found for shear bond strength. Mineral deposition was found in GBNNT, GATAB, and GBNNT/ATAB groups after 14 and 28 days. The addition of 0.2% BNNT/ATAB to an experimental orthodontic adhesive inhibited bacterial growth and induced mineral deposition without affecting the properties of the material.

5.
Braz. oral res. (Online) ; 33: e010, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-989483

RESUMO

Abstract This in situ study aimed to evaluate the antibacterial and anti-demineralization effects of an experimental orthodontic adhesive containing triazine and niobium phosphate bioglass (TAT) around brackets bonded to enamel surfaces. Sixteen volunteers were selected to use intra-oral devices with six metallic brackets bonded to enamel blocks. The experimental orthodontic adhesives were composed by 75% BisGMA and 25% TEGDMA containing 0% TAT and 20% TAT. Transbond XT adhesive (TXT) was used as a control group. Ten volunteers, mean age of 29 years, were included in the study. The six blocks of each volunteer were detached from the appliance after 7 and 14 days to evaluate mineral loss and bacterial growth including total bacteria, total Streptococci, Streptococci mutans, and Lactobacilli. Statistical analysis was performed using GLM model - univariate analysis of variance for microhardness and 2-way ANOVA for bacterial growth (p<0.05). The 20% TAT adhesive caused no difference between distances from bracket and the sound zone at 10-µm deep after 7 and 14 days. After 14 days, higher mineral loss was shown around brackets at 10- to 30-µm deep for TXT and 0% TAT adhesives compared to 20% TAT. S. mutans growth was inhibited by 20% TAT adhesive at 14 days. Adhesive with 20% TAT showed lower S. mutans and total Streptococci growth than 0% TAT and TXT adhesives. The findings of this study show that the adhesive incorporated by triazine and niobium phosphate bioglass had an anti-demineralization effect while inhibiting S. mutans and total Streptococci growth. The use of this product may inhibit mineral loss of enamel, preventing the formation of white spot lesions.


Assuntos
Humanos , Masculino , Feminino , Adulto , Adulto Jovem , Óxidos/farmacologia , Fosfatos/farmacologia , Streptococcus/efeitos dos fármacos , Desmineralização do Dente/prevenção & controle , Cimentos Dentários/farmacologia , Lactobacillus/efeitos dos fármacos , Antibacterianos/farmacologia , Nióbio/farmacologia , Cerâmica/farmacologia , Cerâmica/química , Método Duplo-Cego , Cimentos Dentários/química , Antibacterianos/química
6.
Dent J (Basel) ; 6(3)2018 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-30082662

RESUMO

The aim of this study was to evaluate enamel roughness, quality of the enamel surfaces and time duration comparing different orthodontic adhesive removal protocols. Premolars were used to test three adhesive removal methods (n = 20): five-blade carbide bur, 30-blade carbide bur, and ultrasonic diamond bur. Bracket was bonded using TransbondTM XT adhesive. Roughness with different parameters was measured before bracket bonding and after adhesive remnants removal. Micromorphological analysis of enamel surface (n = 5) was performed by SEM images and categorized in enamel damage index-"perfect"; "satisfying"; "imperfect"; and "unacceptable". Time was measured in seconds. All removal methods caused increased roughness in relation to Ra, Rq, and Rz parameters (X axis) comparing to healthy enamel surface. Enamel surface resulted from removal using five-blade burs was scored as satisfactory. Carbide bur groups decreased the roughness values of Ra, Rq, and Rz parameters on the Y axis and enamel surface was considered unacceptable. The 30-blade group increased symmetry (Rsk) and flattening (Rku) parameters of roughness and surface was scored as unsatisfactory. Diamond bur removed adhesive in 54.8 s, faster than five-blade carbide bur. The five-blade bur group resulted in less enamel roughness than the 30-blade and diamond groups.

7.
J Appl Oral Sci ; 24(4): 404-10, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27556213

RESUMO

OBJECTIVE: This study aimed to incorporate silver nanoparticle solutions (AgNP) in an orthodontic adhesive and evaluate its physicochemical and antimicrobial properties. MATERIAL AND METHODS: Silver nanoparticle solutions were added to a commercial adhesive in different concentrations (w/w): 0%, 0.11%, 0.18%, and 0.33%. Shear bond strength (SBS) test was performed after bonding metal brackets to enamel. Raman spectroscopy was used to analyze in situ the degree of conversion (DC) of the adhesive layer. The surface free energy (SFE) was evaluated after the measurement of contact angles. Growth inhibition of Streptococcus mutans in liquid and solid media was determined by colony-forming unit count and inhibition halo, respectively. One-way ANOVA was performed for SBS, DC, SFE, and growth inhibition. RESULTS: The incorporation of AgNP solution decreased the SBS (p<0.001) and DC in situ (p<0.001) values. SFE decreased after addition of 0.18% and 0.33% AgNP. Growth inhibition of S. mutans in liquid media was obtained after silver addition (p<0.05). CONCLUSIONS: The addition of AgNP solutions to Transbond™ XT adhesive primer inhibited S. mutans growth. SBS, DC, and SFE values decreased after incorporation up to 0.33% AgNP solution without compromising the chemical and physical properties of the adhesive.


Assuntos
Antibacterianos/química , Resinas Compostas/química , Cimentos Dentários/química , Nanopartículas Metálicas/química , Prata/química , Streptococcus mutans/efeitos dos fármacos , Animais , Bovinos , Contagem de Colônia Microbiana , Colagem Dentária/métodos , Esmalte Dentário/efeitos dos fármacos , Esmalte Dentário/microbiologia , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Braquetes Ortodônticos/microbiologia , Tamanho da Partícula , Reprodutibilidade dos Testes , Resistência ao Cisalhamento , Análise Espectral Raman , Streptococcus mutans/crescimento & desenvolvimento , Propriedades de Superfície
8.
J. appl. oral sci ; J. appl. oral sci;24(4): 404-410, July-Aug. 2016. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-792598

RESUMO

ABSTRACT Orthodontic treatment with fixed brackets plays a major role on the formation of white spot lesions. Objective This study aimed to incorporate silver nanoparticle solutions (AgNP) in an orthodontic adhesive and evaluate its physicochemical and antimicrobial properties. Material and Methods Silver nanoparticle solutions were added to a commercial adhesive in different concentrations (w/w): 0%, 0.11%, 0.18%, and 0.33%. Shear bond strength (SBS) test was performed after bonding metal brackets to enamel. Raman spectroscopy was used to analyze in situ the degree of conversion (DC) of the adhesive layer. The surface free energy (SFE) was evaluated after the measurement of contact angles. Growth inhibition of Streptococcus mutans in liquid and solid media was determined by colony-forming unit count and inhibition halo, respectively. One-way ANOVA was performed for SBS, DC, SFE, and growth inhibition. Results The incorporation of AgNP solution decreased the SBS (p<0.001) and DC in situ (p<0.001) values. SFE decreased after addition of 0.18% and 0.33% AgNP. Growth inhibition of S. mutans in liquid media was obtained after silver addition (p<0.05). Conclusions The addition of AgNP solutions to Transbond™ XT adhesive primer inhibited S. mutans growth. SBS, DC, and SFE values decreased after incorporation up to 0.33% AgNP solution without compromising the chemical and physical properties of the adhesive.


Assuntos
Animais , Bovinos , Prata/química , Streptococcus mutans/efeitos dos fármacos , Resinas Compostas/química , Cimentos Dentários/química , Nanopartículas Metálicas/química , Antibacterianos/química , Tamanho da Partícula , Análise Espectral Raman , Streptococcus mutans/crescimento & desenvolvimento , Propriedades de Superfície , Teste de Materiais , Contagem de Colônia Microbiana , Reprodutibilidade dos Testes , Colagem Dentária/métodos , Braquetes Ortodônticos/microbiologia , Esmalte Dentário/efeitos dos fármacos , Esmalte Dentário/microbiologia , Resistência ao Cisalhamento , Cura Luminosa de Adesivos Dentários
9.
Angle Orthod ; 86(3): 391-8, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26177358

RESUMO

OBJECTIVE: To determine the consensus among studies that adhesive resin application improves the bond strength of orthodontic brackets and the association of methodological variables on the influence of bond strength outcome. MATERIALS AND METHODS: In vitro studies were selected to answer whether adhesive resin application increases the immediate shear bond strength of metal orthodontic brackets bonded with a photo-cured orthodontic adhesive. Studies included were those comparing a group having adhesive resin to a group without adhesive resin with the primary outcome measurement shear bond strength in MPa. A systematic electronic search was performed in PubMed and Scopus databases. RESULTS: Nine studies were included in the analysis. Based on the pooled data and due to a high heterogeneity among studies (I(2)  =  93.3), a meta-regression analysis was conducted. The analysis demonstrated that five experimental conditions explained 86.1% of heterogeneity and four of them had significantly affected in vitro shear bond testing. The shear bond strength of metal brackets was not significantly affected when bonded with adhesive resin, when compared to those without adhesive resin. CONCLUSIONS: The adhesive resin application can be set aside during metal bracket bonding to enamel regardless of the type of orthodontic adhesive used.


Assuntos
Colagem Dentária , Braquetes Ortodônticos , Condicionamento Ácido do Dente , Cimentos Dentários , Análise do Estresse Dentário , Humanos , Teste de Materiais , Análise de Regressão , Cimentos de Resina , Resistência ao Cisalhamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA