Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Oral Rehabil ; 26(8): 631-4, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10447815

RESUMO

Due to gradual resorption of the edentulous ridge bone, removable prostheses often require denture base relines to improve fit and stability. This research evaluated the bond strength between one heat-cured acrylic resin (Lucitone 550(R)) and two hard chairside reline resins, after two different periods of storage in water (50 h and 30 days). The bond strength was evaluated using a tensile test. The mode of failure, adhesive or cohesive, was also recorded. The results submitted to the Kruskal-Wallis test indicated that the highest tensile strengths were achieved with intact Lucitone 550(R) denture base resin in both periods of storage in water. After 50 h of storage in water, Duraliner II(R) reline material exhibited the highest bond strength to the denture base resin. After 30 days of storage in water, Duraliner II(R) reline resin demonstrated a significant reduction in adhesion, showing lower tensile bond strength than Kooliner(R) material. Both hard chairside reline materials failed adhesively across Lucitone 550(R) denture base resin, in both periods of time.


Assuntos
Resinas Acrílicas/química , Reembasadores de Dentadura , Reembasamento de Dentadura , Água/química , Adesividade , Colagem Dentária , Bases de Dentadura , Retenção de Dentadura , Humanos , Teste de Materiais , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo
2.
J Prosthet Dent ; 80(4): 434-8, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9791790

RESUMO

STATEMENT OF PROBLEM: Because water sorption of autopolymerizing acrylic reline resins is accompanied by volumetric change, it is a physical property of importance. As residual monomer leaches into the oral fluids and causes tissue irritation, low solubility of these resins is desired. Another requirement is a satisfactory bond between the autopolymerizing acrylic resins and the denture base acrylic resin. PURPOSE: This study compared the water sorption, solubility, and the transverse bond strength of 2 autopolymerizing acrylic resins (Duraliner II and Kooliner) and 1 heat-polymerizing acrylic resin (Lucitone 550). MATERIAL AND METHODS: The water sorption and solubility test was performed as per International Standards Organization Specification No. 1567 for denture base polymers. Bond strengths between the autopolymerizing acrylic resins and the heat-polymerizing acrylic resin were determine with a 3-point loading test made on specimens immersed in distilled water at 37 degrees C for 50 hours and for 30 days. Visual inspection determined whether failures were adhesive or cohesive. RESULTS: Duraliner II acrylic resin showed significantly lower water sorption than Kooliner and Lucitone 550 acrylic resins. No difference was noted in the solubility of all materials. Kooliner acrylic resin demonstrated significantly lower transverse bond strength to denture base acrylic resin and failed adhesively. The failures seen with Duraliner II acrylic resin were primarily cohesive in nature. CONCLUSIONS: Autopolymerizing acrylic reline resins met water sorption and solubility requirements. However, Kooliner acrylic resin demonstrated significantly lower bond strength to denture base acrylic resin.


Assuntos
Resinas Acrílicas/química , Colagem Dentária , Água/química , Absorção , Adsorção , Análise de Variância , Bases de Dentadura , Reembasamento de Dentadura , Temperatura Alta , Humanos , Teste de Materiais , Solubilidade , Estresse Mecânico , Propriedades de Superfície , Fatores de Tempo
3.
J Prosthet Dent ; 77(3): 328-31, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9069091

RESUMO

Acrylic resin denture teeth often exhibit rapid occlusal wear, which may lead to a loss of chewing efficiency and a loss of vertical dimension of occlusion. The use of metal occlusal surfaces on the acrylic resin denture teeth will minimize occlusal wear. Several articles have described methods to construct metal occlusal surfaces; however, these methods are time-consuming, costly, and sometimes considered to be unesthetic. These methods also require that the patient be without the prosthesis for the time necessary to perform the laboratory procedures. This article presents a quick, simple, and relatively inexpensive procedure for construction of composite occlusal surfaces on complete and partial dentures.


Assuntos
Resinas Compostas , Dente Artificial , Resinas Acrílicas , Planejamento de Dentadura , Humanos , Tecnologia Odontológica/métodos
4.
J Prosthet Dent ; 76(4): 414-7, 1996 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8897299

RESUMO

The selection and use of hard chairside reline resins must be made with regard to dimensional stability, which will influence the accuracy of fit of the denture base. This study compared the dimensional change of two hard chairside reline resins (Duraliner II and Kooliner) and one heat-curing denture base resin (Lucitone 550). A stainless steel mold with reference dimensions (AB, CD) was used to obtain the samples. The materials were processed according to the manufacturer's recommendations. Measurements of the dimensions were made after processing and after the samples had been stored in distilled water at 37 degrees C for eight different periods of time. The data were recorded and then analyzed with analysis of variance. All materials showed shrinkage immediately after processing (p < 0.05). The only resin that exhibited shrinkage after 60 days of storage in water was Duraliner II; these changes could be clinically significant in regard of tissue fit.


Assuntos
Resinas Acrílicas/química , Bases de Dentadura , Reembasadores de Dentadura , Reembasamento de Dentadura , Análise de Variância , Humanos , Polímeros/química , Água/química
5.
Rev Odontol UNESP ; 19(1): 227-33, 1990.
Artigo em Português | MEDLINE | ID: mdl-2099552

RESUMO

The authors analysed the simultaneous effects of the dimensional and weight alteration of resins utilized for esthetic facets submitted to warehousing conditions and periods of time. The resins showed different behaviour and a neat correlation between dimensional alteration and weight. The condition of immersion promoted dimensional alteration 50% lower and an alteration of weight three times higher.


Assuntos
Resinas Compostas , Facetas Dentárias , Prótese Parcial Fixa , Resinas Sintéticas/química , Resinas Acrílicas/química , Estética Dentária , Poliuretanos , Fatores de Tempo
6.
Rev Odontol UNESP ; 19(1): 245-50, 1990.
Artigo em Português | MEDLINE | ID: mdl-2099554

RESUMO

The authors looked for the verification of the fatigue of retentive clasps utilized on the removable partial denture. According to this, it was idealized and built on assay machine, that through movements, simulate the insertion and removal of the clasp for a pattern tooth, manufactured on cobalt-chromium which has all the preparation normally utilized to the correct confection of this type of prosthesis. It was utilized three different commercial alloys based on cobalt-chromium: L1-Biosil; L2-Steldent; L3-Duracron. It was utilized the T clasp of Roach, with was tested upon three different proportions among width and thickness: E1-1.7;E2-2.0 and E3-2.3 and was casted through two casting techniques: F1-oxygen-gas and F2-oxygen-acetylene. The clasps were tested on the machine, which allowed the reading of the number of insertion and removal cycles made until fatigue appeared. The obtained results were submitted to the statistic analysis and the authors concluded that: a) L3 (Duracrom) obtained the best results followed by L1 (Biosil) and finally L3 (Steldent); b) among the analyzed thickness, the best results were obtained by E3, followed by E2 and after this E1; c) form the casting techniques, F2 gave us the best results.


Assuntos
Ligas de Cromo , Técnica de Fundição Odontológica , Retenção de Dentadura , Prótese Parcial Removível , Dente Pré-Molar , Humanos , Teste de Materiais
7.
Rev Odontol UNESP ; 19(1): 251-8, 1990.
Artigo em Português | MEDLINE | ID: mdl-2099555

RESUMO

The authors tested the T clasp of Roach in three differents proportions among width and thickness: E1-1.7; E2-2.0 and E3-2.3, with a constant length of 15 mm. These clasps were casted with three cobalt-chromium alloys (L1-Biosil; L2-Steldent and L3-Duracrom), through two casting techniques (F1-oxygen-gas and F2-oxygen-acetylene). The fatigue of the clasps were verified by using and assay machine, that through movements, simulate the insertion and removal of the clasps for a pattern which were obtained from a premolar, prepared in a surveyor. This machine detect the fatigue of the clasps and count the number of cycles of insertion and removal realized. The obtained results of the interaction between the analysed factors, were submitted to the statistic analysis and the authors concluded that: a) the interaction of factors, Alloy x Thickness, Alloy x Casting Technique and Thickness x Casting Technique did not change the order of effects that the factors showed separately but gave rise to effects of different magnitude for any observed sense; b) the simultaneous interaction of the factors Alloy x Thickness x Casting Technique confirmed the superiority of the L3 alloy, the thickness E3 and the F2 casting technique.


Assuntos
Ligas de Cromo , Técnica de Fundição Odontológica , Retenção de Dentadura , Dente Pré-Molar , Humanos , Teste de Materiais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA