RESUMO
BACKGROUND: Exercise oscillatory ventilation (EOV) is related to worse prognosis in patients with heart failure (HF). However, its determination is subjective and there is no standard measure to identify it. The aim of the study was to evaluate and characterize the EOV of patients with HF using the ventilation dispersion index (VDI). METHODS AND RESULTS: Patients underwent cardiopulmonary exercise testing (CPX), EOV was assessed by 2 reviewers and the VDI was calculated. The receiver operator curve analysis was used to assess the ability of the VDI to predict EOV. Pearson's correlation test was performed to determine the relationship between VDI and CPX variables. Forty-three patients with HF underwent CPX and were divided into 2 groups: with a VDI of less than 0.601 and a VDI of 0.601 or greater. An area under the curve of 0.759 was observed in the receiver operator curve analysis between VDI and EOV (Pâ¯=â¯.008). The VDI showed a significant correlation with the ventilatory CPX variables. According to the cut-off point obtained on the receiver operator curve, patients with a VDI of 0.601 or greater had lower left ventricular ejection fraction and higher values of resting minute ventilation and peak minute ventilation. CONCLUSIONS: The VDI proved to be a good predictor of EOV in patients with HF.