Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clinics (Sao Paulo) ; 79: 100427, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38945113

RESUMO

OBJECTIVES: [51Cr]CrEDTA is used to measure the Glomerular Filtration Rate (GFR) in different clinical conditions. However, there is no consensus on the ideal number of blood samples to be taken and at what time points to measure its clearance. This study aimed to compare Slope Intercept (SI) and Single-Sample (SS) methods for measuring GFR in patients with solid tumors, stratified by age, GFR, and Body Mass Index (BMI). METHODS: 1,174 patients with cancer were enrolled in this prospective study. GFR was calculated by the SI method using blood samples drawn 2-, 4-, and 6-hours after [51Cr]CrEDTA injection (246-GFR). GFR was also measured using the SI method with samples at 2 and 4 hours (24-GFR) and at 4 and 6 hours (46-GFR), and SS methods according to Groth (4Gr-GFR) and Fleming (4Fl-GFR). Statistical analysis was performed to assess the accuracy, precision, and bias of the methods. RESULTS: Mean 246-GFR was 79.2 ± 21.9 mL/min/1.73 m2. ANOVA indicated a significant difference between 4Gr-GFR and the reference 246-GFR. Bias was lower than 5 mL/min/1.73 m2 for all methods, except for SS methods in subgroups BMI > 40 kg/m2; GFR > 105 or < 45. Precision was adequate and accuracy of 30 % was above 98% for all methods, except for SS methods in subgroup GFR < 45. CONCLUSION: 46-GFR and 246-GFR have high agreement and may be used to evaluate kidney function in patients with solid tumors. Single-sample methods can be adopted in specific situations, for non-obese patients with expected normal GFR.


Assuntos
Taxa de Filtração Glomerular , Neoplasias , Humanos , Taxa de Filtração Glomerular/fisiologia , Feminino , Masculino , Estudos Prospectivos , Pessoa de Meia-Idade , Neoplasias/fisiopatologia , Neoplasias/sangue , Estudos Transversais , Idoso , Adulto , Radioisótopos de Cromo/farmacocinética , Índice de Massa Corporal , Reprodutibilidade dos Testes , Fatores de Tempo , Adulto Jovem , Idoso de 80 Anos ou mais , Valores de Referência , Fatores Etários
3.
J Nephrol ; 29(3): 401-409, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26298845

RESUMO

BACKGROUND: Single-pass batch dialysis (SBD) is a well-established system for treatment of end-stage renal disease. However, little evidence is available on sustained low-efficiency extended dialysis (SLED) performed with SBD in patients with acute kidney injury (AKI) in the intensive care unit (ICU). METHODS: All SLED-SBD sessions conducted on AKI patients in nine ICUs between March and June 2010 were retrospectively analyzed regarding the achieved metabolic and fluid control. Logistic regression was performed to identify the risk factors associated with hypotension and clotting during the sessions. RESULTS: Data from 106 patients and 421 sessions were analyzed. Patients were 54.2 ± 17.0 years old, 51 % males, and the main AKI cause was sepsis (68 %); 80 % of patients needed mechanical ventilation and 55 % vasoactive drugs. Hospital mortality was 62 %. The median session time was 360 min [interquartile range (IQR) 300-360] and prescribed ultrafiltration was 1500 ml (IQR 800-2000). In 272 sessions (65 %) no complications were recorded. No heparin was used in 269/421 procedures (64 %) and system clotting occurred in 63 sessions (15 %). Risk factors for clotting were sepsis [odds ratio (OR) 2.32 (1.31-4.11), p = 0.004], no anticoagulation [OR 2.94 (1.47-5.91), p = 0.002] and the prescribed time (hours) [OR 1.14 (1.05-1.24), p = 0.001]. Hypotension occurred in 25 % of procedures and no independent risk factors were identified by logistic regression. Adequate metabolic and fluid balance was achieved during SLED sessions. Median blood urea decreased from 107 to 63 mg/dl (p < 0.001), potassium from 4.1 to 3.9 mEq/l (p < 0.001), and increased bicarbonate (from 21.4 to 23.5 mEq/l, p < 0.001). Median fluid balance during session days ranged from +1300 to -20 ml/24 h (p < 0.001). CONCLUSIONS: SLED-SBD was associated with a low incidence of clotting despite frequent use of saline flush, and achieved a satisfactory hemodynamic stability and reasonable metabolic and fluid control in critically-ill AKI patients.


Assuntos
Injúria Renal Aguda/terapia , Estado Terminal , Diálise Renal/métodos , Adulto , Idoso , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Diálise Renal/efeitos adversos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA