1.
Appl Radiat Isot ; 68(9): 1662-70, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20227885

RESUMO

Simulating X-ray images has been of great interest in recent years as it makes possible an analysis of how X-ray images are affected owing to relevant operating parameters. In this paper, a procedure for simulating computed radiographic images using the Monte Carlo code MCNPX is proposed. The sensitivity curve of the BaFBr image plate detector as well as the characteristic noise of a 16-bit computed radiography system were considered during the methodology's development. The results obtained confirm that the proposed procedure for simulating computed radiographic images is satisfactory, as it allows obtaining results comparable with experimental data.


Assuntos
Modelos Estatísticos , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Simulação por Computador , Desenho Assistido por Computador , Análise de Falha de Equipamento , Método de Monte Carlo , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Appl Radiat Isot ; 67(10): 1824-8, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19540128

RESUMO

In order to guarantee the structural integrity of oil plants it is crucial to monitor the amount of weld thickness loss in offshore pipelines. However, in spite of its relevance, this parameter is very difficult to determine, due to both the large diameter of most pipes and the complexity of the multi-variable system involved. In this study, a computational modeling based on Monte Carlo MCNPX code is combined with computed radiography to estimate the weld thickness loss in large-diameter offshore pipelines. Results show that computational modeling is a powerful tool to estimate intensity variations in radiographic images generated by weld thickness variations, and it can be combined with computed radiography to assess weld thickness loss in offshore and subsea pipelines.

3.
Appl Radiat Isot ; 66(5): 587-92, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18339548

RESUMO

This work presents a methodology for digital radiography simulation for industrial applications using the MCNPX radiography tally. In order to perform the simulation, the energy-dependent response of a BaFBr imaging plate detector was modeled and introduced in the MCNPX radiography tally input. In addition, a post-processing program was used to convert the MCNPX radiography tally output into 16-bit digital images. Simulated and experimental images of a steel pipe containing corrosion alveoli and stress corrosion cracking were compared, and the results showed good agreement between both images.


Assuntos
Simulação por Computador , Intensificação de Imagem Radiográfica , Método de Monte Carlo
4.
Appl Radiat Isot ; 66(9): 1213-7, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18308576

RESUMO

One of the main preoccupations of diagnostic radiology is to guarantee a good image-sparing dose to the patient. In the present study, Monte Carlo simulations, with MCNPX code, coupled with an adult voxel female model (FAX) were performed to investigate how image quality and dose in digital chest radiography vary with tube voltage (80-150 kV) using air-gap technique and a computed radiography system. Calculated quantities were normalized to a fixed value of entrance skin exposure (ESE) of 0.0136 R. The results of the present analysis show that the image quality for chest radiography with imaging plate is improved and the dose reduced at lower tube voltage.


Assuntos
Intensificação de Imagem Radiográfica/métodos , Radiografia Torácica/métodos , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação