Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Rev. colomb. quím. (Bogotá) ; 49(1): 11-19, Jan.-Apr. 2020. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1098954

RESUMO

Abstract Amino acids (AA) composition in cocoa beans can predict the synthesis of compounds which affect cocoa flavor. Thus, their determination is of great interest for the community implied in the commercialization and production of cocoa. In consequence, in this work, the analysis of AA produced during cocoa beans fermentation and roasting was carried out. A high-performance liquid chromatographic method with DAD detection at 254 nm was optimized and validated for their selective determination in six varieties of cocoa beans with different genotypes, all of them grown in Venezuela. AA were extracted by defatted milled cocoa powder ultrasonication using purified water at 70 °C. Then, they were derivatized with phenyl isothiocyanate, and their derivatives were separated, using a reversed-phase column with gradient elution, achieving a satisfactory resolution among the peaks (greater than 1.0) in less than 29 min. 110 cocoa samples were analyzed. Results showed a significant content of free AA, ranging from 3.87 to 5.97 g/kg in absence of fermentation with a predominance of acidic AA. Moreover, there is a progressive increase in the AA content while fermentation process occurs, with a predominance of hydrophobic AA such as alanine, valine, isoleucine, leucine, phenylalanine, and tyrosine. On the other hand, all cocoa types showed a partial degradation of free AA during the roasting step, especially the hydrophobic ones.


Resumen La determinación de aminoácidos (AA) en granos de cacao es de gran interés ya que estos son considerados como unos de los precursores de su sabor y aroma. Por esta razón, el presente trabajo tuvo como objetivo optimizar y validar un método por cromatografía líquida con detección DAD a 254 nm para la determinación selectiva de AA durante la fermentación y tostado en seis variedades de granos de cacao con diferentes genotipos, todos estos cultivados en Venezuela. Los AA se extrajeron del polvo de cacao molido y desgrasado con agua pura a 70 ºC, utilizando la técnica de ultrasonido. Luego, se derivatizaron con fenilotiocianato para separar sus derivados con buena resolución en menos de 29 min en una columna de fase reversa, utilizando gradiente de elución. Se analizaron 110 muestras de cacao. Los resultados mostraron un contenido significativo de AA libres, entre 3,87 y 5,97 g/kg, en ausencia de fermentación con predominio de AA ácidos, y un aumento progresivo en el contenido de AA, mientras ocurre el proceso de fermentación, con un predominio de AA hidrófobos como alanina, valina, isoleucina, leucina, fenilalanina y tirosina. Además, todos los tipos de cacao mostraron una degradación parcial de AA libres durante la etapa de tostado, especialmente los AA hidrófobos.


Resumo A determinação dos aminoácidos (AA) nos grãos de cacau é importante, pois são considerados um dos precursores de seu sabor e aroma. Neste trabalho, um método foi otimizado e validado por cromatografia líquida com detecção DAD a 254 nm para a determinação seletiva de AA durante a fermentação e torrefação em seis variedades de grãos de cacau com diferentes genótipos, todos cultivados na Venezuela. Os AAs foram extraídos do pó de cacau moído e desengordurados com água pura a 70 ºC usando a técnica de ultrassom. Em seguida, foram derivatizados com feniltiocianato, e os derivados foram separados com boa resolução em menos de 29 minutos em uma coluna de fase invertida usando eluição em gradiente. Foram analisadas 110 amostras de cacau. Os resultados mostraram um conteúdo significativo de AA livre entre 3,87 e 5,97 g/kg na ausência de fermentação com predominância de AA ácidos e um aumento progressivo no conteúdo de AA enquanto o processo de fermentação ocorre com predominância de AA hidrófobos como alanina, valina, isoleucina, leucina, fenilalanina e tirosina. Além disso, todos os tipos de cacau apresentaram uma degradação parcial do AA livre durante a fase de torrefação, principalmente o AA hidrofóbico.

2.
J Sep Sci ; 33(12): 1779-86, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20491055

RESUMO

In this paper, a method was described to determine cocaine (COC) and benzoylecgonine (BZE) in human urine samples by GC-MS detection. The extraction of analytes from urine samples was achieved in an Oasis hydrophilic-lipophilic balance column (20 mmx3.9 mm id, dp=25 microm; Waters, USA), incorporated in a multisyringe flow injection system, used for the sample treatment. Finally, to improve the volatility of the BZE, an in-line derivatization reaction with N,O-bis (trimethylsilyl) trifluoroacetamide with 1% trimethylchlorosilane was made microwave-assisted in order to reduce the reaction time. The results showed that the proposed method is a good alternative for the analysis of COC and BZE in urine samples because it offers advantages compared with those described in the literature, which include simplicity in the sample treatment, the sensitivity and selectivity necessary to determine the analytes of interest at low levels in the urine and high sample throughput.


Assuntos
Cocaína/análogos & derivados , Cocaína/urina , Análise de Injeção de Fluxo/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Limite de Detecção , Micro-Ondas , Extração em Fase Sólida
3.
J Pharm Biomed Anal ; 50(2): 194-9, 2009 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-19446420

RESUMO

Column-switching high-performance liquid chromatographic (HPLC) method has been developed and validated for quantification of losartan, telmisartan, and valsartan in human urine. Urine samples were diluted on the extraction mobile phase (1:4, v/v) and a volume of 20 microL of this mixture were directly injected onto the HPLC system. The analytes were extracted from the matrix using an on-line solid-phase extraction procedure involving a precolumn packed with 25 microm C(18) alkyl-diol support (ADS), and a solution 2% methanol in 5mM phosphate buffer (pH 3.8) at a flow-rate of 0.8 mL/min for isolation and preconcentration of losartan, telmisartan, and valsartan. The enriched analytes were back-flushed after, onto the analytical column with a mixture of 5mM phosphate buffer (pH 3.8)-acetonitrile-methanol (65:20:15, v/v/v) at a flow-rate of 3.0 mL/min and detected by fluorescence at 259 and 399 nm as excitation and emission wavelength respectively. The separation of losartan, telmisartan, and valsartan was achieved on a Chromolith RP-18e monolithic column. The method provides extraction recoveries from spiked urine samples greater than 93%. Intra-day and inter-day precision were generally acceptable; the intra-day-assay C.V. was <3.5 for all compounds and the inter-day-assay C.V. was < 3.7%. The estimated calibration range was 0.001-2.5 microg/mL(-1) with excellent coefficient of determination (>0.9981). The detection limits for losartan, telmisartan, and valsartan at a signal-to-noise ratio of 5:1 were 0.002, 0.0002 and 0.001 microg/mL(-1) when a sample volume of 20 microL was injected. The proposed method permitted the simultaneous determination of losartan, telmisartan, and valsartan in 8 min, with an adequate precision and sensitivity. However, the overlap of the sample cleanup step with the analysis increases the sampling frequency to 12 samples/h. The developed column-switching method was successfully applied for the determination of these analytes in human urine samples of patients submitted at ARA-IIs therapy.


Assuntos
Anti-Hipertensivos/urina , Benzimidazóis/urina , Benzoatos/urina , Cromatografia Líquida de Alta Pressão/métodos , Losartan/urina , Espectrometria de Fluorescência/métodos , Tetrazóis/urina , Valina/análogos & derivados , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Telmisartan , Valina/urina , Valsartana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA