Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
PLoS One ; 17(9): e0274087, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36137162

RESUMO

The purpose of this study was to evaluate and compare positive cystography techniques at 5%, 10%, and 20%, as well as three different double-contrast protocols for detecting radiolucent uroliths with a diameter of less than 3.0 mm in dogs. Six cadavers were used, one was selected at random to represent the negative control, and the others were submitted to urolith implantation in the bladder by urethral catheter. Three radiology professionals blindly accessed ventrodorsal and -lateral projections of each test. Contrast at 20% showed greater diagnostic sensitivity, but with greater difficulty identifying the number and size of the uroliths. Consequently, double-contrast techniques are better and should be used for diagnostic and therapeutic planning. Sensitivity and specificity tests demonstrated that positive 5% cystography and different concentrations of double contrast obtained better results in terms of sensitivity and specificity. However, due to the presence of a greater amount of artifacts in the 5% cystography, it is suggested that double contrast is used for this purpose, especially with the removal of contrast excess (protocol 2).


Assuntos
Doenças do Cão , Cálculos Urinários , Animais , Doenças do Cão/diagnóstico por imagem , Cães , Radiografia , Sensibilidade e Especificidade , Bexiga Urinária/diagnóstico por imagem , Cálculos Urinários/diagnóstico por imagem
2.
Ciênc. anim. bras. (Impr.) ; 11(1): 149-155, 2010. tab
Artigo em Português | VETINDEX | ID: vti-3823

RESUMO

A bioimpedância (BIC) é um método que aplica à tecnologia da impedância no estudo da composição corporal pela avaliação da diferença da condutividade elétrica dos tecidos. Os resultados da BIC são expressos pelas medidas primárias de resistência (R) e reatância (Xc). Neste experimento, o método foi desenvolvido para verificar a viabilidade do uso de três diferentes tipos de eletrodos sobre a reprodutibilidade dos valores de R e Xc em gatos adultos. As médias de R e Xc com adesivos e agulhas de acupuntura não diferiram entre si (p≥0,05), e os menores valores dos coeficientes de variação obtidos com estes eletrodos sinalizaram para uma melhor reprodutibilidade dos resultados quando comparados com os da agulha hipodérmica. Os diferentes tipos de eletrodos não interferiram nos valores da massa magra (MM) estimada por equação específica, porém a agulha de acupuntura mostrou ser o eletrodo mais estável e de melhor aplicabilidade. A MM determinada com os diferentes tipos de eletrodos foi superior (p≤0,05) à obtida com a absorciometria de raios-x de dupla energia (DEXA), provavelmente decorrente da equação utilizada na sua estimativa.(AU)


The bioelectrical impedance is a method that applies impedance technology in the study of physical composition by evaluation of electrical conductivity difference on each organism tissue. The results of bioelectrical impedance (BIC) are expressed by the resistance (R) and reactance (Xc) primary measures. This study was carried out to verify the viability of the use of three different electrodes on the repeatability of R and Xc values in adult cats. The averages of R and Xc estimated by adhesive and acupuncture needles did not differ from each other (p≥0.05) and the smaller values of the variation coefficient acquired with these electrodes signaled for a better reproducibility of the results when compared with hypodermic needle. The different types of electrode did not interfere on the LBM estimated by specific equation, but the acupuncture needle electrode was the most stable and easily applicable. The LBM values determined with the different types of electrode were higher (p≤0.05) than the LBM dual-energy X-ray absorptiometry (DEXA) values, probably due to the specific equation to LBM estimation used in this study.(AU)


Assuntos
Gatos , Eletrodos , Índice de Massa Corporal , Gatos/classificação , Eletricidade , Água/efeitos adversos , Gorduras/efeitos adversos
3.
Ciênc. anim. bras. (Impr.) ; 11(1): 149-155, 2010. tab
Artigo em Português | VETINDEX | ID: biblio-1472918

RESUMO

A bioimpedância (BIC) é um método que aplica à tecnologia da impedância no estudo da composição corporal pela avaliação da diferença da condutividade elétrica dos tecidos. Os resultados da BIC são expressos pelas medidas primárias de resistência (R) e reatância (Xc). Neste experimento, o método foi desenvolvido para verificar a viabilidade do uso de três diferentes tipos de eletrodos sobre a reprodutibilidade dos valores de R e Xc em gatos adultos. As médias de R e Xc com adesivos e agulhas de acupuntura não diferiram entre si (p≥0,05), e os menores valores dos coeficientes de variação obtidos com estes eletrodos sinalizaram para uma melhor reprodutibilidade dos resultados quando comparados com os da agulha hipodérmica. Os diferentes tipos de eletrodos não interferiram nos valores da massa magra (MM) estimada por equação específica, porém a agulha de acupuntura mostrou ser o eletrodo mais estável e de melhor aplicabilidade. A MM determinada com os diferentes tipos de eletrodos foi superior (p≤0,05) à obtida com a absorciometria de raios-x de dupla energia (DEXA), provavelmente decorrente da equação utilizada na sua estimativa.


The bioelectrical impedance is a method that applies impedance technology in the study of physical composition by evaluation of electrical conductivity difference on each organism tissue. The results of bioelectrical impedance (BIC) are expressed by the resistance (R) and reactance (Xc) primary measures. This study was carried out to verify the viability of the use of three different electrodes on the repeatability of R and Xc values in adult cats. The averages of R and Xc estimated by adhesive and acupuncture needles did not differ from each other (p≥0.05) and the smaller values of the variation coefficient acquired with these electrodes signaled for a better reproducibility of the results when compared with hypodermic needle. The different types of electrode did not interfere on the LBM estimated by specific equation, but the acupuncture needle electrode was the most stable and easily applicable. The LBM values determined with the different types of electrode were higher (p≤0.05) than the LBM dual-energy X-ray absorptiometry (DEXA) values, probably due to the specific equation to LBM estimation used in this study.


Assuntos
Gatos , Eletrodos , Gatos/classificação , Índice de Massa Corporal , Eletricidade , Gorduras/efeitos adversos , Água/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA