Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Crit Care Explor ; 4(11): e0779, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36406885

RESUMO

To describe ventilation strategies used during extracorporeal membrane oxygenation (ECMO) for neonatal respiratory failure among level IV neonatal ICUs (NICUs). DESIGN: Cross-sectional electronic survey. SETTING: Email-based Research Electronic Data Capture survey. PATIENTS: Neonates undergoing ECMO for respiratory failure at level IV NICUs. INTERVENTIONS: A 40-question survey was sent to site sponsors of regional referral neonatal ECMO centers participating in the Children's Hospitals Neonatal Consortium. Reminder emails were sent at 2- and 4-week intervals. MEASUREMENTS AND MAIN RESULTS: Twenty ECMO centers responded to the survey. Most primarily use venoarterial ECMO (65%); this percentage is higher (90%) for congenital diaphragmatic hernia. Sixty-five percent reported following protocol-based guidelines, with neonatologists primarily responsible for ventilator management (80%). The primary mode of ventilation was pressure control (90%), with synchronized intermittent mechanical ventilation (SIMV) comprising 80%. Common settings included peak inspiratory pressure (PIP) of 16-20 cm H2O (55%), positive end-expiratory pressure (PEEP) of 9-10 cm H2O (40%), I-time 0.5 seconds (55%), rate of 10-15 (60%), and Fio2 22-30% (65%). A minority of sites use high-frequency ventilation (HFV) as the primary mode (5%). During ECMO, 55% of sites target some degree of lung aeration to avoid complete atelectasis. Fifty-five percent discontinue inhaled nitric oxide (iNO) during ECMO, while 60% use iNO when trialing off ECMO. Nonventilator practices to facilitate decannulation include bronchoscopy (50%), exogenous surfactant (25%), and noninhaled pulmonary vasodilators (50%). Common ventilator thresholds for decannulation include PEEP of 6-7 (45%), PIP of 21-25 (55%), and tidal volume 5-5.9 mL/kg (50%). CONCLUSIONS: The majority of level IV NICUs follow internal protocols for ventilator management during neonatal respiratory ECMO, and neonatologists primarily direct management in the NICU. While most centers use pressure-controlled SIMV, there is considerable variability in the range of settings used, with few centers using HFV primarily. Future studies should focus on identifying respiratory management practices that improve outcomes for neonatal ECMO patients.

2.
J Pediatr ; 220: 73-79.e3, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32089332

RESUMO

OBJECTIVE: To assess differences in regional brain temperatures during whole-body hypothermia and test the hypothesis that brain temperature profile is nonhomogenous in infants with hypoxic-ischemic encephalopathy. STUDY DESIGN: Infants with hypoxic-ischemic encephalopathy were enrolled prospectively in this observational study. Magnetic resonance (MR) spectra of basal ganglia, thalamus, cortical gray matter, and white matter (WM) were acquired during therapeutic hypothermia. Regional brain tissue temperatures were calculated from the chemical shift difference between water signal and metabolites in the MR spectra after performing calibration measurements. Overall difference in regional temperature was analyzed by mixed-effects model; temperature among different patterns and severity of injury on MR imaging also was analyzed. Correlation between temperature and depth of brain structure was analyzed using repeated-measures correlation. RESULTS: In total, 53 infants were enrolled (31 girls, mean gestational age: 38.6 ± 2 weeks; mean birth weight: 3243 ± 613 g). MR spectroscopy was acquired at mean age of 2.2 ± 0.6 days. A total of 201 MR spectra were included in the analysis. The thalamus, the deepest structure (36.4 ± 2.3 mm from skull surface), was lowest in temperature (33.2 ± 0.8°C, compared with basal ganglia: 33.5 ± 0.9°C; gray matter: 33.6 ± 0.7°C; WM: 33.8 ± 0.9°C, all P < .001). Temperatures in more superficial gray matter and WM regions (depth: 21.9 ± 2.4 and 21.5 ± 2.2 mm) were greater than the rectal temperatures (33.4 ± 0.4°C, P < .03). There was a negative correlation between temperature and depth of brain structure (rrm = -0.36, P < .001). CONCLUSIONS: Whole-body hypothermia was effective in cooling deep brain structures, whereas superficial structures were warmer, with temperatures significantly greater than rectal temperatures.


Assuntos
Temperatura Corporal/fisiologia , Encéfalo/diagnóstico por imagem , Hipotermia Induzida , Hipóxia-Isquemia Encefálica/terapia , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Encéfalo/fisiologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Prospectivos , Reto/fisiologia , Termometria
3.
J Pediatr ; 173: 56-61.e3, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27004674

RESUMO

OBJECTIVE: To develop and validate the Neonatal Risk Estimate Score for Children Using Extracorporeal Respiratory Support, which estimates the risk of in-hospital death for neonates prior to receiving respiratory extracorporeal membrane oxygenation (ECMO) support. STUDY DESIGN: We used an international ECMO registry (2008-2013); neonates receiving ECMO for respiratory support were included. We divided the registry into a derivation sample and internal validation sample, by calendar date. We chose candidate variables a priori based on published evidence of association with mortality; variables independently associated with mortality in logistic regression were included in this parsimonious model of risk adjustment. We evaluated model discrimination with the area under the receiver operating characteristic curve (AUC), and we evaluated calibration with the Hosmer-Lemeshow goodness-of-fit test. RESULTS: During 2008-2013, 4592 neonates received ECMO respiratory support with mortality of 31%. The development dataset contained 3139 patients treated in 2008-2011. The Neo-RESCUERS measure had an AUC of 0.78 (95% CI 0.76-0.79). The validation cohort had an AUC = 0.77 (0.75-0.80). Patients in the lowest risk decile had an observed mortality of 7.0% and a predicted mortality of 4.4%, and those in the highest risk decile had an observed mortality of 65.6% and a predicted mortality of 67.5%. CONCLUSIONS: Neonatal Risk Estimate Score for Children Using Extracorporeal Respiratory Support offers severity-of-illness adjustment for neonatal patients with respiratory failure receiving ECMO. This score may be used to adjust patient survival to assess hospital-level performance in ECMO-based care.


Assuntos
Oxigenação por Membrana Extracorpórea/mortalidade , Mortalidade Hospitalar , Medição de Risco , Peso ao Nascer , Feminino , Idade Gestacional , Hérnias Diafragmáticas Congênitas/mortalidade , Hérnias Diafragmáticas Congênitas/terapia , Humanos , Concentração de Íons de Hidrogênio , Hipertensão Pulmonar/mortalidade , Hipertensão Pulmonar/terapia , Recém-Nascido , Modelos Logísticos , Masculino , Síndrome de Aspiração de Mecônio/terapia , Curva ROC , Sistema de Registros , Insuficiência Renal/mortalidade , Síndrome do Desconforto Respiratório do Recém-Nascido/mortalidade , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Insuficiência Respiratória/mortalidade , Insuficiência Respiratória/terapia , Sepse/mortalidade , Sepse/terapia , Índice de Gravidade de Doença , Fatores Sexuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA