Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Int Endod J ; 42(10): 867-73, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19751288

RESUMO

AIM: To compare two resin-based root canal sealers (AH Plus and dual cure Epiphany) in terms of flow, polymerization stress and bond strength to dentine. METHODOLOGY: Flow was evaluated by measuring the diameter of uncured discs of sealer (0.5 mL) after 7 min compression (20N) between two glass plates (n = 5). Polymerization stress was monitored for 60 min in 1-mm thick discs bonded to two glass rods (Ø = 5 mm) attached to a universal testing machine (n = 3). Bond strength was analyzed through micropush-out test (n = 10) and failure mode was examined with scanning electron microscope (100x and 2500x). Data were statistically analyzed using the Student's t-test (alpha = 0.05). RESULTS: Polymerization stress was 0.32 +/- 0.07 MPa for Epiphany self-cure, 0.65 +/- 0.08 MPa for Epiphany light-cure and zero for AH Plus (P < 0.05). Flow data and bond strength values were 30.9 +/- 1.1, 28.6 +/- 0.7 mm and 6.3 +/- 5.3, 17.8 +/- 7.5 MPa for Epiphany and AH Plus, respectively (P < 0.001). Failure mode was predominantly cohesive in the sealer for both materials. CONCLUSIONS: Epiphany had higher flow and polymerization stress and lower bond strength values to dentine than AH Plus. In view of these findings it can be implied that AH Plus would provide a better seal.


Assuntos
Colagem Dentária , Dentina/ultraestrutura , Cimentos de Resina/química , Materiais Restauradores do Canal Radicular/química , Análise do Estresse Dentário/instrumentação , Resinas Epóxi/química , Humanos , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Polímeros/química , Reologia , Estresse Mecânico , Propriedades de Superfície
2.
Rev. med. PUCRS ; 2(2): 49-53, jan.-mar. 1990. tab
Artigo em Português | LILACS | ID: lil-161066

RESUMO

Revisaram-se as mortes ocorridas no Hospital Säo Lucas da PUCRS no primeiro trimestre de 1989, comparando-se as informaçöes contidas nos prontuários médicos com as obtidas nos atestados de óbito. Somente 29 (31,18 por cento) das declaraçöes de óbitos estudadas näo apresentaram erros em seu preenchimento nos itens considerados essenciais. Em 32 (34,45 por cento) atestados, foi modificada a causa básica do óbito. Discute-se a importância do treinamento continuado de médicos e estudantes de medicina para que se obtenha estatísticas confiáveis em saúde pública.


Assuntos
Humanos , Masculino , Feminino , Atestado de Óbito , Prontuários Médicos/estatística & dados numéricos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA