Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Ophthalmol ; 2019: 7018937, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31885892

RESUMO

Prospective, randomized, comparative, and controlled study to estimate the association between angle κ distance and higher-order aberrations (HOAs) with postoperative visual acuity after presbyopia-correcting IOL implantation. Forty-three eyes from 43 patients were included and randomly assigned in two groups for either AT LISA tri 839MP or Acrysof IQ PanOptix IOL implantation. The OPD-Scan III analyzer was utilized to assess the angle κ distance and higher-order aberration (HOAs). Twenty-three eyes were in the Acrysof IQ PanOptix group and 20 patients in the AT LISA tri 839MP group. The uncorrected distance visual acuity (UDVA) for the PanOptix group was 0.092 ± 0.10, whereas for AT LISA tri was 0.050 ± 0.06 (P=0.229). The uncorrected intermediate visual acuity (UIVA) for the PanOptix group was 0.173 ± 0.18, whereas for AT LISA tri, it was 0.182 ± 0.11 (P=0.669). Uncorrected near visual acuity (UNVA) was 0.068 ± 0.04 and 0.085 ± 0.07, respectively (P=0.221). Also, correlation coefficient between HOAs and the Strehl ratio for each group were -0.768 (P < 0.0001) and -0.863 (P=0.0001). Patients implanted with both trifocal IOLs showed excellent postoperative visual performance at all distances at the six-month follow-up visit. No association was found between angle κ distance and postoperative visual acuity regardless of the angle κ magnitude or the two trifocal IOLs inner optical diameter. Also, internal aberrations demonstrated a significant inverse correlation with the Strehl ratio for both trifocal IOLs.

2.
Int Ophthalmol ; 38(3): 951-957, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28444525

RESUMO

PURPOSE: To compare the biometric measurements obtained from the Verion Image-Guided System to those obtained by auto-refracto-keratometer in normal eyes. METHODS: This is a prospective, observational, comparative study conducted at the Asociación para Evitar la Ceguera en México I.A.P., Mexico. Three sets of keratometry measurements were obtained using the image-guided system to assess the coefficient of variation, the within-subject standard deviation and intraclass correlation coefficient (ICC). A paired Student t test was used to assess statistical significance between the Verion and the auto-refracto-keratometer. A Pearson's correlation coefficient (r) was obtained for all measurements, and the level of agreement was verified using Bland-Altman plots. RESULTS: The right eyes of 73 patients were evaluated by each platform. The Verion coefficient of variation was 0.3% for the flat and steep keratometry, with the ICC being greater than 0.9 for all parameters measured. Paired t test showed statistically significant differences between groups (P = 0.0001). A good correlation was evidenced for keratometry values between platforms (r = 0.903, P = 0.0001 for K1, and r = 0.890, P = 0.0001). Bland-Altman plots showed a wide data spread for all variables. CONCLUSION: The image-guided system provided highly repeatable corneal power and keratometry measurements. However, significant differences were evidenced between the two platforms, and although values were highly correlated, they showed a wide data spread for all analysed variables; therefore, their interchangeable use for biometry assessment is not advisable.


Assuntos
Afacia Pós-Catarata/diagnóstico , Biometria/métodos , Extração de Catarata , Córnea/patologia , Topografia da Córnea/métodos , Lentes Intraoculares , Adolescente , Adulto , Afacia Pós-Catarata/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA