Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Appl Radiat Isot ; 83 Pt C: 245-8, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23938078

RESUMO

The purpose of this study was to assess the current status of image quality and dose in computed radiographic digital mammography (CRDM) systems. Studies included CRDM systems of various models and manufacturers which dose and image quality comparisons were performed. Due to the recent rise in the use of digital radiographic systems in Mexico, CRDM systems are rapidly replacing conventional film-screen systems without any regard to quality control or image quality standards. Study was conducted in 65 mammography facilities which use CRDM systems in the Mexico City and surrounding States. The systems were tested as used clinically. This means that the dose and beam qualities were selected using the automatic beam selection and photo-timed features. All systems surveyed generate laser film hardcopies for the radiologist to read on a scope or mammographic high luminance light box. It was found that 51 of CRDM systems presented a variety of image artefacts and non-uniformities arising from inadequate acquisition and processing, as well as from the laser printer itself. Undisciplined alteration of image processing settings by the technologist was found to be a serious prevalent problem in 42 facilities. Only four of them showed an image QC program which is periodically monitored by a medical physicist. The Average Glandular Dose (AGD) in the surveyed systems was estimated to have a mean value of 2.4 mGy. To improve image quality in mammography and make more efficient screening mammographic in early detection of breast cancer is required new legislation.


Assuntos
Mamografia/normas , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Neoplasias da Mama/prevenção & controle , Feminino , Humanos , Programas de Rastreamento , México/epidemiologia
2.
Clin Neurophysiol ; 112(12): 2281-7, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11738200

RESUMO

OBJECTIVES: To compare two different functional procedures in the assessment of brain ischemia in patients with neurocysticercosis (NCC): (1) electroencephalography (EEG) evaluated by brain maps and EEG current sources in the frequency domain using variable resolution electromagnetic tomography and (2) blood flow analyzed by computerized tomography assessed with stable Xe (Xe-CT). METHODS: Eleven patients with NCC at different evolution stages were studied. CT and Xe-CT scans, as well as quantitative electroencephalography with source calculation in the frequency domain, were obtained. All patients showed cysts and in 6 of them there were also vascular complications: two of them presented calcifications of the middle cerebral artery, two other subjects showed calcifications of the vessels in the circle of Willis and the remaining two had brain infarctions. RESULTS: In the cyst areas important hypoperfused zones were observed, as intense as those observed in infarcted areas. Damage to the blood-brain barrier was originated by parasites in colloidal phase (final cysticerci stage) producing large areas of edema and hypoperfusion. Abnormal delta EEG activity was observed in very large lesions, probably generated by partial cortical deafferentation; and abnormal theta activity was mainly related to the presence of edema. CONCLUSIONS: Sources of abnormal EEG activity were very similar in topography to the hypoperfused areas.


Assuntos
Circulação Cerebrovascular , Eletroencefalografia , Neurocisticercose/fisiopatologia , Adulto , Vias Aferentes/fisiopatologia , Barreira Hematoencefálica , Encéfalo/diagnóstico por imagem , Edema Encefálico/etiologia , Edema Encefálico/fisiopatologia , Córtex Cerebral/fisiopatologia , Infarto Cerebral/fisiopatologia , Eletroencefalografia/métodos , Feminino , Humanos , Magnetoencefalografia , Masculino , Pessoa de Meia-Idade , Neurocisticercose/complicações , Neurocisticercose/diagnóstico por imagem , Ritmo Teta , Tomografia Computadorizada por Raios X , Xenônio
3.
Clin Electroencephalogr ; 31(4): 165-9, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11056837

RESUMO

EEGs from 16 patients with stroke in three different stages of evolution were recorded. EEG sources were calculated every 0.39 Hz by frequency domain VARETA. The main source was within the delta band in 2 out of 4 chronic patients, and in 67% of the patients in the acute or subacute stages when edema (cytotoxic or vasogenic) was present. Moreover, all patients showed abnormal activity in the theta band. Sources of abnormal activity in cortical or corticosubcortical infarcts were located in the cortex, surrounding the lesion. At the site of the infarct, a decrease of EEG power was observed. Sources of abnormal theta power coincided with edema and/or ischemic penumbra.


Assuntos
Edema Encefálico/fisiopatologia , Encéfalo/fisiopatologia , Infarto Cerebral/fisiopatologia , Eletroencefalografia , Adulto , Idoso , Encéfalo/diagnóstico por imagem , Edema Encefálico/diagnóstico por imagem , Infarto Cerebral/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Tomografia Computadorizada por Raios X
4.
Electroencephalogr Clin Neurophysiol ; 102(4): 279-85, 1997 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9146487

RESUMO

In previous papers we have proposed that in patients with space-occupying lesions, delta power was related with the volume of the lesion and theta power with the volume of the edema. In this report we analyze the evolution of 10 patients with space-occupying lesions in whom we measured the volume of the lesion and of the edema before and after treatment that produced changes in these volumes. EEGs were recorded in the leads of the 10-20 system referenced to linked earlobes. Delta and theta powers were calculated for voltage and current source densities (CSD) and compared with age-norms to compute conventional Z-maps. These maps provide probability statements about the deviation of observed values from the norm. Rank correlations between the change in the volume of the lesion before and after treatment and the change in Z-values before and after treatment were significant only in the delta band. However, rank correlations between the change in the volume of the edema and the change in EEG Z-values were only significant in the theta band. These correlations were higher for CSD than for voltage estimates. We also observed that the site of the lesion and of the edema was better represented by CSD maps than by voltage maps. These results are also in agreement with our previous reports, in which we observed more precise localization of brain lesions by CSD than by voltage estimates.


Assuntos
Edema Encefálico/fisiopatologia , Adulto , Idoso , Edema Encefálico/diagnóstico por imagem , Mapeamento Encefálico , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/fisiopatologia , Cisticercose/diagnóstico por imagem , Cisticercose/fisiopatologia , Eletroencefalografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
5.
Electroencephalogr Clin Neurophysiol ; 87(4): 196-205, 1993 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-7691550

RESUMO

In a group of patients with space-occupying brain lesions, CT measurements were correlated with absolute power (AP) and relative power (RP) of the delta, theta, alpha and beta EEG bands, calculated from the raw EEG potentials (EEGp) and from the Laplacian estimates also called "current source densities" (CSD). Rank correlations were calculated between the number of abnormal values in each band and the following CT measures: volume of the lesion and of the edema, density of the edema, percentage of ventricular collapse and midline shift. Abnormal spectral values are those which are significantly higher than the norm for the same age, in the delta and theta bands, and significantly lower in the alpha and beta bands. Spectral parameters obtained from the CSD showed higher correlations with CT measures than those calculated from the EEGp. In the Laplacian, all CT measures had a significant correlation with delta AP. Theta AP was significantly correlated with the volume and density of the edema, as well as with midline shift. Significant correlations were also observed with delta and alpha RP. However, changes in RP were considered to be a consequence of the increase in delta AP. Canonical correlation analyses between AP and RP calculated from EEGp or CSD and the first 3 CT measures showed that the volume of the lesion was only correlated with delta AP and RP. The volume and density of the edema showed a significant correlation with delta, theta and alpha AP calculated from EEGp and only with theta and alpha AP in the Laplacian. Since the EEGp tends to produce a more extensive and diffuse picture of abnormality, whereas the Laplacian acts as a spatial filter emphasizing local sources over distant sources, we concluded that edema is related not to delta activity, but to the theta and alpha power.


Assuntos
Encefalopatias/diagnóstico por imagem , Encefalopatias/fisiopatologia , Adolescente , Adulto , Idoso , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/fisiopatologia , Eletroencefalografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA