RESUMO
Aim: The purpose of this study was to evaluate the efficacy to determine the root canal length, in vitro,of both the electronic apex locator (M2) and the autostop (AS - M3) functions of the Endus Duo Gnatus endodontic motor (Gnatus, São Paulo, SP, Brazil). Methods: Thirty extracted human single-rooted premolars had their root canal lengths (TLs) up to the apical foramen determined using the Endus Duo Gnatus in two ways: (1) In the stainless steel (SS) control group, the measurement was obtained using a stainless steel hand instrument with the electronic locator mode (M2 function) connected to a stainless-steel hand instrument (K-file #15). In the NiTi rotary instrument (NiTi RI) intervention group, the measurement was obtained during the instrumentation (M3 function) of the root canals with a nickel-titanium rotary instrument (Hyflex CM: Coltene Whaledent, Cuyahoga Falls, OH, USA), size 25/.06. The NiTi manually used instrument (NiTi MUI) Intervention group performed the measurement in locator mode using a Hyflex instrument, placed to true length manually. Statistical analysis was performed using ANOVA followed by the Tukey post-hoc test with a significance level of p < 0.05. Results: The true mean length and standard deviation (SD) of the standardized root canals were 18.40 ± 2.14mm, while the mean lengths and standard deviations (SD) were 18.29 ± 1.89mm, 18.22 ± 1.85mm, and 17.24 ± 2.09mm for the SS, NiTi RI, and NiTi MUI groups, respectively. However, data from the NiTi MUI Intervention group indicated shorter root canal lengths when compared to the SS control group and the NiTi RI Intervention group values, and were significantly shorter than the true canal length (p < 0.001). Conclusions:The use of the motor in NiTi RI Intervention group showed acceptable results. However, the NiTi MUI Intervention group resulted in unacceptable short measurements.
Objetivo: O objetivo deste estudo foi avaliar a eficácia na determinação do comprimento do canal radicular, in vitro, das funções localizador eletrônico foraminal (M2) e auto-parada durante a instrumentação (M3) do motor endodôntico Endus Duo Gnatus ( Gnatus, São Paulo, SP, Brasil). Métodos: Trinta pré-molares humanos uniradiculares extraídos tiveram seus comprimentos de canais radiculares (CRTs) até o forame apical determinados usando o Endus Duo Gnatus de duas maneiras: (1) No grupo controle de aço inoxidável (SS), a medida foi obtida usando um instrumento manual de aço inoxidável com modo de localização eletrônica foraminal (função M2) conectado a um instrumento manual de aço inoxidável (lima tipo K #15). No grupo intervenção instrumento rotatório NiTi (NiTi RI), a medida foi obtida durante a instrumentação (função M3) dos canais radiculares com instrumento rotatório de níquel-titânio (Hyflex CM: Coltene Whaledent, Cuyahoga Falls, OH, EUA), tamanho 25/.06. O grupo de intervenção NiTi instrumento usado manualmente (NiTi MUI) realizou a medição no modo localizador foraminal usando um instrumento Hyflex, colocado manualmente no comprimento real do dente. A análise estatística foi realizada por meio de ANOVA seguida do teste post-hoc de Tukey com nível de significância de p < 0,05. Resultados: Os comprimentos reais médios dos dentes e desvios-padrão (DP) dos canais radiculares padronizados foram 18,40 ± 2,14 mm, enquanto os comprimentos médios e desvios- padrão (DP) foram 18,29 ± 1,89 mm, 18,22 ± 1,85 mm e 17,24 ± 2,09 mm para os grupos SS, NiTi RI e NiTi MUI, respectivamente. No entanto, os dados do grupo de intervenção NiTi MUI indicaram comprimentos de canais radiculares mais curtos quando comparados aos valores do grupo controle SS e do grupo de intervenção NiTi RI, e foram significativamente mais curtos que o comprimento real do canal (p < 0,001). Conclusões: A utilização do motor no grupo Intervenção NiTi RI apresentou resultados aceitáveis. No entanto, o grupo de intervenção NiTi MUI resultou em medições curtas inaceitáveis.
Assuntos
Pesos e Medidas , Equipamentos Odontológicos , Cavidade Pulpar , EndodontiaRESUMO
ABSTRACT Objective: Compare the accuracy of early diagnosis of simulated internal root resorptions and external root resorption, using digital periapical radiography and cone beam computed tomography. Methods: Root resorption were simulated in extracted human teeth by demineralization with 5% nitric acid solution and 8% Sodium Hypochlorite in different periods (1 and 5 days). For the group external root resorption (n=12) composite resin cylinders were positioned on middle third of buccal surface of roots, to delimit application of demineralization substances. In group internal root resorptions (n=12) the teeth were sectioned longitudinally, and the composite resin cylinders were positioned in the middle third of root canals. The teeth were mounted in a dry mandible and evaluated by digital radiography and tomography. The images were evaluated by two examiners. Results: Analyzing the tomographic images in period of 1 day, the examiner 2 identified internal root resorptions that were not identified in radiographic images (p<0.05). No examiner was capable of diagnosing external root resorption irrespective of exam, in the group of 1 day (p>0.05). In 5 day period of induction, both exams identified internal root resorptions (p>0.05), however, the tomographic images were more effective in identifying external root resorption (p <0.05) for both examiners. Conclusion: Cone beam computed tomography was shown to be more effective than digital periapical radiography for detecting internal root resorptions with 1 day of induction. The imaginological resources used in this study were not able to early detect external root resorption.
RESUMO Objetivo: Comparar a acurácia do diagnóstico precoce de reabsorções radiculares interna (RRI) e reabsorções radiculares externa (RRE) simuladas, por meio de radiografia periapical digital e tomografia computadorizada de feixe cônico. Métodos: Reabsorções radiculares foram simuladas em dentes humanos extraídos utilizando a desmineralização com ácido nítrico 5% e hipoclorito de sódio 8% em diferentes períodos (1 e 5 dias). Para o grupo reabsorções radiculares externa (n=12) cilindros de resina composta foram posicionados no terço médio das faces vestibulares das raízes, delimitando a aplicação das substâncias de desmineralização. No grupo reabsorções radiculares interna (n=12) os dentes foram seccionados longitudinalmente, e os cilindros de resina posicionados no terço médio dos canais radiculares. Os dentes foram montados em mandíbula seca e avaliados por meio de radiografia digital e tomografia por dois examinadores. Resultados: Nas imagens tomográficas no período de 1 dia, o examinador 2 identificou reabsorções radiculares interna as quais não foram identificadas nas radiografias (p<0,05). Nenhum examinador foi capaz de diagnosticar as reabsorções radiculares externa independente do exame no grupo de 1 dia (p>0.05). No período de indução de 5 dias ambos os exames identificaram as reabsorções radiculares interna (p>0,05), entretanto, as tomografias foram mais eficazes na identificação das reabsorções radiculares externa (p<0,05) para ambos os examinadores. Conclusão: A tomografia computadorizada de feixe cônico mostrou-se mais eficaz do que a radiografia periapical digital na detecção de reabsorções radiculares interna com 1 dia de indução. Os recursos imaginológicos utilizados neste estudo não foram capazes de detectar precocemente a reabsorção radicular externa.
RESUMO
Objectives: This study aimed to compare the efficiency of three different substances used for the bleaching of non-vital teeth. Methods: Forty bovine teeth were divided into five groups: three test groups (sodium perborate + 20% hydrogen peroxide SPG; 37% carbamide peroxide CPG; 35% hydrogen peroxide HPG) and two control groups (CG1 and CG2). Teeth of the test groups were stained artificially with blood and bleached using the in-office and walking bleach techniques. The efficiency of the bleaching agents was evaluated objectively by comparing the color variables L*, a*, and b* measured spectrophotometrically according to the CIELab system. The data were analyzed by ANOVA and the Tukey test, adopting a 5% level of significance. Results: The results showed a reduction in lightness (L*) after staining and an increase after the bleaching sessions. The values of a* and b* increased after staining and decreased after the application of the bleaching substances. Conclusions: All substances used for non-vital tooth bleaching exhibited the same bleaching efficiency. No significant differences in this efficiency were observed between the bleaching techniques at the end of the experiment. However, in-office bleaching provided the same bleaching result as the walking bleach technique within a shorter period. Clinical significance: Given the increasing demand for esthetics, the use of different bleaching techniques and the variety of whitening agents, oral health professionals should offer evidence-based treatment, more efficient and in less time.
Objetivos: este estudo teve como objetivo comparar a eficiência de três substâncias diferentes utilizadas no clareamento de dentes não vitais. Métodos: quarenta dentes bovinos foram divididos em cinco grupos: três grupos-teste (perborato de sódio + 20% de peróxido de hidrogênio - PS; 37% de peróxido de carbamida - PC; 35% de peróxido de hidrogênio - PH) e dois grupos-controle (CG1 e CG2). Os dentes dos grupos-teste foram pigmentados artificialmente com sangue e clareados usando as técnicas de branqueamento em consultório e walking-bleach. A eficiência dos agentes clareadores foi avaliada objetivamente, comparando-se as variáveis de cor L*, a* e b* medidas espectrofotometricamente de acordo com o sistema CIELab. Os dados foram analisados por ANOVA e teste de Tukey, adotando nível de significância de 5%. Resultados: os resultados mostraram uma redução da luminosidade (L*) após a pigmentação e um aumento após as sessões de clareamento. Os valores de a* e b* aumentaram após a pigmentação e diminuíram após a aplicação das substâncias clareadoras. Conclusões: todas as substâncias utilizadas no clareamento de dente não-vital apresentaram a mesma eficiência. Não foram observadas diferenças significativas nesta eficiência entre as técnicas de branqueamento no final do experimento. No entanto, o branqueamento em consultório forneceu o mesmo resultado de clareamento que a técnica walking-bleach em um período mais curto. Significado clínico: Dada a crescente demanda por estética, o uso de diferentes técnicas de clareamento e a variedade de agentes clareadores, os profissionais de saúde bucal devem oferecer tratamento baseado em evidências, mais eficiente e em menos tempo.
Assuntos
Clareamento Dental , Peróxido de HidrogênioRESUMO
Introdução: o diagnóstico de fratura radicular é difícil, pois não há sinais/sintomas clínicos e características radiográficas patognomônicas, podendo ser confundido com um insucesso no tratamento endodôntico e até mesmo com doença periodontal. Objetivo: descrever as características clínicas, radiográficas e tomográficas em dentes com suspeita de fratura radicular. Métodos: a amostra foi composta por seis indivíduos cujos dados clínicos foram coletados, realizados testes de percussão vertical e horizontal, verificando se o dente apresentava mobilidade dentária e bolsa periodontal. Achados radiográficos e tomográficos foram avaliados em relação à presença de fratura radicular e de lesão periapical e/ou perda óssea associada ao terço apical/lateral da raiz para se obter o diagnóstico complementar da fratura radicular. Resultados: os achados clínicos mais prevalentes foram percussões vertical e horizontal positivos seguidos de dor e mobilidade. Os exames por imagem evidenciaram que todos os casos de suspeita de fratura radicular estavam relacionados a dentes com pino metálico. Em apenas um caso, não foi possível visualizar a lesão periapical e/ou perda óssea e a fratura na radiografia periapical, sendo detectadas nas imagens tomográficas. Conclusões: os achados clínicos de suspeita de fraturas radiculares são muito variáveis, necessitando correlacioná-los com exames de imagem. A TCFC se mostrou mais eficaz que a radiografia periapical na detecção da linha de fratura, porém esses dois exames podem ser utilizados para complementar o exame clínico e alcançar um diagnóstico mais acurado..
Introduction: the diagnosis of dental fracture is usually difficult because there are no pathognomonic clinical signs/symptoms and radiographic characteristics, and may be mistaken for failure of endodontic treatment and even periodontal disease. Purpose: to describe clinical, radiographic and tomographic characteristics in teeth with suspected root fracture. Methods: the sample consisted of 06 individuals and their clinical data were collected. Vertical and horizontal percussion tests were performed, verifying tooth mobility and periodontal pocket. In relation to radiographic and tomographic findings, the presence of root fracture and periapical lesion and/or bone loss associated with the apical/lateral third of the root were evaluated in order to obtain the diagnosis of root fracture. Results: the most prevalent clinical findings were positive vertical and horizontal percussions followed by pain and mobility. Imaging tests showed that all cases of suspected root fracture were related to teeth with metallic post. In only one case, it was not possible to visualize the periapical lesion and/or bone loss and fracture in the periapical radiography, being detected in tomographic images. It`s possible to conclude with the analysis of some clinical cases that cone-beam computed tomography favors accuracy and precision regarding the visualization, location and extension of root fracture, as well as periapical alterations. Conclusions: the clinical findings of suspected root fractures are very variable, requiring to correlate them with imaging exams. The CBCT was more effective than the periapical radiography in the detection of the fracture line, but these two exams can be used to complement the clinical examination and reach a more accurate diagnosis.
Assuntos
Radiografia Dentária , Endodontia , Tomografia Computadorizada de Feixe CônicoRESUMO
Abstract Aim: To evaluate canal transportation and centering ability of Protaper and WaveOne systems in curved root canals by cone-beam computed tomography. Methods: Twenty human molars were randomly divided into two groups according to the system used: Group GP (ProTaper Universal(r)) and group GW (WaveOne(tm)). CT scans were performed before and after the chemo-mechanical preparation on three points: 2 mm, 3 mm and 4 mm from the tooth apex. The cuttings in dentin were measured and results were statistically analyzed. Results: In GP, there was higher percentage in transport at 2 mm and 4 mm toward the mesial wall of the tooth root compared to GW (p<0.05). There was no difference between the systems regarding their centering ability. Conclusions: None of the systems was able to touch all the dentin walls and stay centered during the chemical-mechanical preparation.
Assuntos
Preparo de Canal Radicular , Endodontia , Tomografia Computadorizada de Feixe CônicoRESUMO
OBJECTIVE: To evaluate in vitro the sealing ability of three materials used as cervical barrier for internal dental bleaching. METHODS: Thirty-three canines were selected, and after biomechanical root canal preparation, the canals were filled by lateral condensation technique. After the filling material setting reaction, the teeth were randomly divided into three groups of ten teeth each, according to the following materials for constructing the cervical barrier: X Temp LC; Vitro Fil; Coltosol. The control group consisted of three teeth, without placement of the cervical cap. Sodium perborate /distilled water associated with 2% Rhodamin B were used as bleaching substance. After placing the bleaching agent in the pulp chamber, access cavities were sealed with temporary cement IRM and samples were stored at 37 ° for 7 days. After this period, the samples were cleaved longitudinally, and leakage was evaluated by the visual method. The data were submitted to Pearson test with a 5% level of significance. RESULTS: No statistically significant difference was found between the study groups, however, the largest number of specimens with a lower degree of leakage were found in the Coltosol group. CONCLUSION: All the materials evaluated for making the cervical cap allowed some level of leakage. .
OBJETIVO: Avaliar in vitro a capacidade seladora de três materiais utilizados como barreira cervical durante o clareamento interno. MÉTODOS: Foram selecionados trinta e três caninos humanos, que após o preparo biomecânico dos canais radiculares, foram obturados pela técnica da condensação lateral ativa. Após a reação de presa do material obturador os dentes foram divididos aleatoriamente em três grupos de dez dentes cada, de acordo com os seguintes materiais para confecção da barreira cervical: X Temp LC; Vitro Fil; Coltosol. O grupo controle constituiu de três dentes sem a confecção do tampão cervical. Utilizou-se como substância clareadora o Perborato de Sódio/ água destilada associado à Rodamina B 2%. Após a colocação do agente clareador na câmara pulpar, as aberturas coronárias foram seladas com cimento provisório IRM e as amostras foram armazenadas em estufa a 37° por 7 dias. Após esse período, as amostras foram clivadas no sentido longitudinal, e a avaliação da infiltração foi realizada pelo método visual. Os dados foram submetidos ao teste estatístico de Kruskal-Wallis, com nível de significância de 5%. RESULTADOS: Não houve diferença estatisticamente significante entre os grupos de estudo, embora o Coltosol tenha obtido maior número de espécimes com menor grau de infiltração. ...
RESUMO
The aim of this work was to verify the existence of correlation between Raman spectroscopy readings of phosphate apatite (~960 cm-1), fluoridated apatite (~575 cm-1) and organic matrix (~1450 cm-1) levels and Diagnodent® readings at different stages of dental caries in extracted human teeth. The mean peak value of fluorescence in the carious area was recorded and teeth were divided in enamel caries, dentin caries and sound dental structure. After fluorescence readings, Raman spectroscopy was carried out on the same sites. The results showed significant difference (ANOVA, p<0.05) between the fluorescence readings for enamel (16.4 ± 2.3) and dentin (57.6 ± 23.7) on carious teeth. Raman peaks of enamel and dentin revealed that ~575 and ~960 cm-1 peaks were more intense in enamel caries. There was significant negative correlation (p<0.05) between the ~575 and ~960 cm-1 peaks and dentin caries. It may be concluded that the higher the fluorescence detected by Diagnodent the lower the peaks of phosphate apatite and fluoridated apatite. As the early diagnosis of caries is directly related to the identification of changes in the inorganic tooth components, Raman spectroscopy was more sensitive to variations of these components than Diagnodent.
Assuntos
Cárie Dentária/diagnóstico , Esmalte Dentário/química , Dentina/química , Durapatita/análise , Lasers Semicondutores , Análise Espectral Raman , Análise de Variância , Apatitas/análise , Fluorescência , Fluorometria , Humanos , Compostos Orgânicos/análise , Estatísticas não Paramétricas , VibraçãoRESUMO
The aim of this work was to verify the existence of correlation between Raman spectroscopy readings of phosphate apatite (∼960 cm−1), fluoridated apatite (∼575 cm−1) and organic matrix (∼1450 cm−1) levels and Diagnodent® readings at different stages of dental caries in extracted human teeth. The mean peak value of fluorescence in the carious area was recorded and teeth were divided in enamel caries, dentin caries and sound dental structure. After fluorescence readings, Raman spectroscopy was carried out on the same sites. The results showed significant difference (ANOVA, p<0.05) between the fluorescence readings for enamel (16.4 ± 2.3) and dentin (57.6 ± 23.7) on carious teeth. Raman peaks of enamel and dentin revealed that ∼575 and ∼960 cm−1 peaks were more intense in enamel caries. There was significant negative correlation (p<0.05) between the ∼575 and ∼960 cm−1 peaks and dentin caries. It may be concluded that the higher the fluorescence detected by Diagnodent the lower the peaks of phosphate apatite and fluoridated apatite. As the early diagnosis of caries is directly related to the identification of changes in the inorganic tooth components, Raman spectroscopy was more sensitive to variations of these components than Diagnodent.
O objetivo desse estudo foi verificar por meio da espectroscopia Raman, a existência de correlação entre os níveis de apatita fosfatada (∼960 cm−1), apatita fluoretada (∼575 cm−1) e matriz orgânica (∼1450 cm−1) e as leituras do Diagnodent® em diferentes estágios de cárie dental em dentes humanos extraídos. O valor médio do pico de fluorescência na área da cárie foi anotado e os dentes divididos em cárie de esmalte, dentina e dente hígido. Após as leituras de fluorescência, foi realizada a espectroscopia Raman nos mesmos sítios. Os resultados mostraram diferença significante (ANOVA p<0,05) entre as leituras de fluorescência para esmalte (16,4 ± 2,3) e dentina (57,6 ± 23,7) nos dentes cariados. Os picos Raman para esmalte e dentina evidenciaram que os picos ∼575 e ∼960 cm−1 foram mais intensos em cárie de esmalte. Houve correlação negativa e significante (p<0,05) entre os picos ∼575 e ∼960 cm−1 e cárie de dentina. Pode-se concluir que quanto maior a fluorescência detectada pelo Diagnodent menor o pico da apatita fosfatada e fluoretada. O diagnóstico precoce da cárie está diretamente relacionado com a identificação de mudanças nos componentes inorgânicos do dente, assim a espectroscopia Raman foi mais sensível para variações desses componentes quando comparada ao Diagnodent.
Assuntos
Humanos , Cárie Dentária/diagnóstico , Esmalte Dentário/química , Dentina/química , Durapatita/análise , Lasers Semicondutores , Análise Espectral Raman , Análise de Variância , Apatitas/análise , Fluorescência , Fluorometria , Compostos Orgânicos/análise , Estatísticas não Paramétricas , VibraçãoRESUMO
Oral mucositis is a harmful side effect of radiotherapy (RT) on the head and neck region. There are encouraging reports on the beneficial aspects of the use of laser light on the treatment of oral mucositis. This paper reports the efficacy of laser phototherapy (LPT) on the treatment of oral mucositis in a patient undergoing RT after surgical removal of a squamous cell carcinoma with osseous invasion of the maxilla. Palatal and commissural lesions were treated with λ660 nm, 40 mW, ∅=4 mm(2), in contact mode, 5 x 2.4 J/cm(2) per point, 14.4 J/cm(2) per session. For treating the lesion on the patient's nasal mucosa, LPT (∅=4 mm(2), λ780 nm, 70 mW, 3 x 2.1 J/cm(2) per point, 6.3 J/cm(2) per session, contact mode) was used on the external area of the nose. A single dose (2.4 J/cm(2)) with the λ660 nm laser, as described before, was applied on the entrance of each nostril. LPT was used 3 times/week during 4 weeks. Treatment results indicate that the use of LPT on oral mucositis was effective and allowed the patient to carry on the RT without interruption. However, long-term and controlled clinical trials are necessary to establish both preventive and curative protocols using LPT.
Assuntos
Irradiação Craniana/efeitos adversos , Lasers Semicondutores/uso terapêutico , Fototerapia/métodos , Lesões por Radiação/terapia , Estomatite/terapia , Adulto , Carcinoma de Células Escamosas/radioterapia , Humanos , Masculino , Neoplasias Maxilares/radioterapia , Mucosa Bucal/efeitos da radiação , Mucosite/etiologia , Mucosite/terapia , Mucosa Nasal/efeitos da radiação , Estomatite/etiologiaRESUMO
Oral mucositis is a harmful side effect of radiotherapy (RT) on the head and neck region. There are encouraging reports on the beneficial aspects of the use of laser light on the treatment of oral mucositis. This paper reports the efficacy of laser phototherapy (LPT) on the treatment of oral mucositis in a patient undergoing RT after surgical removal of a squamous cell carcinoma with osseous invasion of the maxilla. Palatal and commissural lesions were treated with λ660 nm, 40 mW, ∅=4 mm², in contact mode, 5 x 2.4 J/cm² per point, 14.4 J/cm² per session. For treating the lesion on the patient's nasal mucosa, LPT (∅=4 mm², λ780 nm, 70 mW, 3 x 2.1 J/cm² per point, 6.3 J/cm² per session, contact mode) was used on the external area of the nose. A single dose (2.4 J/cm²) with the λ660 nm laser, as described before, was applied on the entrance of each nostril. LPT was used 3 times/week during 4 weeks. Treatment results indicate that the use of LPT on oral mucositis was effective and allowed the patient to carry on the RT without interruption. However, long-term and controlled clinical trials are necessary to establish both preventive and curative protocols using LPT.
A mucosite oral é um efeito colateral prejudicial da radioterapia na região de cabeça e pescoço. Existem estudos que evidenciam o efeito benéfico do uso da luz laser no tratamento da mucosite oral. O objetivo deste caso clínico foi o de avaliar a eficácia da fototerapia laser no tratamento da mucosite oral em um paciente sendo submetido a radioterapia, após a remoção cirúrgica de um carcinoma escamocelular, com invasão óssea da maxila. As lesões do palato e das comissuras labiais foram tratadas com λ660 nm, 40 mW, ∅=4 mm², em contato, 5 x 2.4 J/cm² por ponto, 14.4 J/cm² por sessão. Na lesão existente na mucosa nasal a fototerapia laser (∅=4 mm², λ780 nm, 70 mW, 3 x 2.1 J/cm² por ponto, 6.3 J/cm² por sessão, em contato) foi utilizada na área externa do nariz. Uma dose única (2.4 J/cm²) com o laser λ660 nm e os parâmetros descritos anteriormente foi aplicado na entrada de cada narina. A fototerapia laser foi utilizada 3 vezes por semana, durante 4 semanas. Os resultados do tratamento são indicativos de que o uso da fototerapia laser em mucosite oral foi efetiva e permitiu ao paciente continuar o tratamento radioterápico sem interrupções. Entretanto, estudos clínicos controlados são necessários para se estabelecer os protocolos, para tratamento e prevenção da mucosite oral, utilizando fototerapia laser.
Assuntos
Adulto , Humanos , Masculino , Irradiação Craniana/efeitos adversos , Lasers Semicondutores/uso terapêutico , Fototerapia/métodos , Lesões por Radiação/terapia , Estomatite/terapia , Carcinoma de Células Escamosas/radioterapia , Neoplasias Maxilares/radioterapia , Mucosa Bucal/efeitos da radiação , Mucosite/etiologia , Mucosite/terapia , Mucosa Nasal/efeitos da radiação , Estomatite/etiologiaRESUMO
OBJECTIVE: The aim of this study was to evaluate the biomechanical preparation of flattened root canals using the following systems: Endo-Eze AET stainless steel oscillatory instruments (Ultradent) and RaCe rotary NiTi instruments (FKG Dentaire). MATERIAL AND METHODS: Twenty extracted human mandibular incisors were randomly assigned to two groups: Group 1 - Instrumentation with oscillatory Endo-Eze AET files (oscillatory technique); Group 2 - Instrumentation with rotary NiTi RaCe files (rotary technique). The teeth were decoronated, had their apices and coronal openings sealed with sticky wax and were embedded in crystal-clear orthophtalic polyester resin. The roots were sectioned transversally with diamond discs at 10 mm (middle third) and 5 mm (apical third) from the apex and the segments were reassembled for instrumentation. The sections were photographed before and after root canal instrumentation and evaluated with respect to whether the original root canal shape was modified by instrumentation. To evaluate the differences in the root canal shape before and after biomechanical preparation, scores were given regarding the instruments touch on the intracanal walls. RESULTS: In middle third of the root canals instrumented with the rotary system, there was a change in the original canal anatomy (p<0.05), with formation of a protuberance in the mesiodistal direction. This protuberance did not occur when the oscillatory instrumentation was used. The oscillatory system had better results in the middle and apical thirds as evaluated by Dunn's multiple-comparison test (p>0.05). CONCLUSION: Under the tested conditions, Endo-Eze oscillatory system yielded the instrumentation of all flattened root canal walls, maintaining the canal original shape throughout the biomechanical preparation, and was more effective than RaCe rotary system.
RESUMO
O presente estudo teve por finalidade avaliar e comparar o preparo biomecânico em raízes mesiais de molares inferiores, mediante quatro técnicas de instrumentação. Para isso, foram utilizados 32 molares inferiores humans extraidos. Após abertura coronária, uma lima tipo K número 10 foi introduzida nos canais mesiais para obtenção da odontometria. Os dentes foram incluídos em resina ortofitálica cristal e as raízes sofreram cortes transversais nos terços cervical e apical, logo em seguida, reposicionados para instrumentação como limas tipo K e Hedstroem (grupo 1), limas ultra-sônicas (grupo 2), limas NiTi rotatória (grupo 3), limas NiTi manual (grupo 4). As secções foram fotografadas antes da instrumentação e após a utilização dos instrumentos, para avaliação do desvio do eixo axial. Os resultados mosraram que no terço cervical e grupo 4 mostrou uma maior quantidade de preparo sem desvio (62,5%), seguido do grupo 3 (50%), do grupo 2 (255) e do grupo 1 (0%). No terço apical, o grupo 3 apresentou uma maior quantidade de secções sem desvio (50%), seguido dos grupos 4 (37,5%), 1 (37,5%) e 2 (25%). Dos 8 dentes instrumentados por grupo, o grupo 3 apresentou 37,5% (3 casos) de preparos sem desvio, seguido de grupo 4, 25% (2 casos). Nos grupos 1 e 2 todos os espécimes apresentaram desvio do centro axial do canal radicular.