Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Mech Behav Biomed Mater ; 148: 106220, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37944227

RESUMO

The present work aims to investigate whether it is possible to identify and quantify the contributions of the interstitial fluid and the solid skeleton to the overall time-dependent behavior of tendons based on a single mechanical test. For this purpose, the capabilities of three different time-dependent models (a viscoelastic, a poroelastic and a poroviscoelastic) were investigated in the modeling of the experimental behavior obtained from semi-confined compression with stress relaxation tests transverse to collagen fibers. The main achieved result points out that the poroviscoelastic model was the only one capable to characterize both the experimental responses of the force and volume changes of the tissue samples. Moreover, further analysis of this model shows that while the kinematics of the sample are mainly governed by the fluid flow (pore pressure contribution of the model), the behavior intrinsically associated with the viscoelastic solid skeleton makes a significant contribution to the experimental force response. This study reinforces the importance of taking both the experimental kinematics and kinetics of tendon tissues into account during the constitutive characterization procedure.


Assuntos
Modelos Biológicos , Tendões , Elasticidade , Estresse Mecânico , Viscosidade
2.
J Biomech ; 87: 120-126, 2019 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-30904336

RESUMO

The transverse deformations of tendons assessed in tensile tests seems to constitute a controversial issue in literature. On the one hand, large positive variations of the Poisson's ratio have been reported, indicating volume reduction under tensile states. On the other hand, negative values were also observed, pointing out an auxetic material response. Based on these experimental observations, the following question is raised: Are these large and discrepant transverse deformations intrinsically related to the constitutive response of tendons or they result from artifacts of the mechanical test setup? In order to provide further insights to this question, an experimental and numerical study on the transverse kinematics of tendons was carried out. Tensile experiments were performed in branches of deep digital flexor tendons of domestic porcine, where the transverse displacements were measured by two high-speed, high-accuracy optical digital micrometers placed transversely to one another. Aiming at a better understanding of the effects of the mechanical test setup in the transverse measurements, a three-dimensional finite element model is proposed to resemble the tensile experiment. The main achieved results strongly support the following hypotheses regarding tensile tests of tendons: the clamping region considerably affects the kinematics of the specimen even at a large distance from the clamps; the transverse deformations are mainly ruled by stiff fibers embedded in a soft matrix; the generalization of the Poisson's ratio to draw conclusions about changes in volume of tendons may lead to misinterpretations.


Assuntos
Modelos Biológicos , Tendões/fisiologia , Resistência à Tração/fisiologia , Animais , Fenômenos Biomecânicos , Elasticidade , Estresse Mecânico , Suínos
3.
J Mech Behav Biomed Mater ; 91: 131-138, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30579110

RESUMO

Present study provides a numerical investigation on multiscale boundary conditions in the computational homogenization of a representative volume element (RVE) of tendon fascicles. A three-dimensional hexagonal-helicoidal finite element RVE composed of two material phases (collagen fibers and cells) and three finite strain viscoelastic models (collagen fibrils, matrix of fibers and cells) compose the multiscale model. Due to the unusual helical geometry of the RVE, the performance of four multiscale boundary conditions is evaluated: the linear boundary displacements model, the minimally constrained model and two mixed boundary conditions allying characteristics of both, linear and minimal models. Numerical results concerning microscopic kinematic fields and macroscopic stress-strain curves point out that one of the mixed models is able to predict the expected multiscale mechanics of the RVE, presenting sound agreement with experimental facts reported in literature, for example: characteristic non-linear shape of the stress-strain curves; macroscopic energy loss by hysteresis; axial rotation of fascicles observed in tensile tests; collagen fibrils are the main load-bearing components of tendons; cells contribute neither to the stiffness nor to the macroscopic energy loss. Moreover, the multiscale model provides important insights on the micromechanics of tendon fascicles, predicting a non-homogeneous and relevant strain localization on cells, even under physiological macroscopic strain amplitudes.


Assuntos
Fenômenos Mecânicos , Modelos Biológicos , Tendões/citologia , Tendões/metabolismo , Fenômenos Biomecânicos , Colágeno/metabolismo , Análise de Elementos Finitos , Estresse Mecânico
4.
J Biomech ; 54: 49-57, 2017 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-28238424

RESUMO

Several constitutive models for fibrous soft tissues used in literature provide a completely isotropic response when fibers are compressed. However, recent experimental investigations confirm the expectation that tendons behave anisotropically during compression tests. Motivated by these facts, the present manuscript presents an appropriate choice of hyperelastic potentials able to predict the coupled mechanical behaviors of tendons under both tensile and compressive loads with a relatively small number of material parameters. The high stiffness of tendons under tensile tests is handled by a transversely isotropic model while the coupled compressive response is modeled by means of a Fung-type potential in terms of Seth-Hill's generalized strain tensors. In present study the logarithm strain measure is used instead of the usually employed Green-Lagrange strain. After a parameter identification procedure, the resulting model showed ability to satisfactorily reproduce the experimental data. Details on the analytical material tangent modulus are provided. Present results will then enhance further researches related to tendon dissipative effects and numerical multiscale investigations.


Assuntos
Modelos Biológicos , Tendões/fisiologia , Animais , Anisotropia , Cavalos , Humanos , Pressão , Ratos , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA