Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Minerva Dent Oral Sci ; 72(4): 185-194, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37066888

RESUMO

INTRODUCTION: A systematic review of the literature available up to October 2020 has been conducted to determine which cranial plane could represent a stable and reliable parameter to evaluate the orientation of the occlusal plane in a frontal view. EVIDENCE ACQUISITION: An electronic research was performed across the following electronic databases: PUBMED, EBSCO, SCOPUS, WoS, COCHRANE LIBRARY, SciELO, EMBASE and GOOGLE SCHOLAR. Observational studies based on imaging and anthropometry were identified, and all languages have been included. The articles were selected and analyzed by three authors independently. PICO format was adopted to analyze the studies and AXIS guidelines were used to assess the quality of evidence. EVIDENCE SYNTHESIS: We found eleven articles eligible for full-text analysis. All studies included only young subjects and analyzed the occlusal plane in relation to the frontal plane traced between the right and left tragus (Camper's and Frankfurt planes), to the interpupillary plane, and to other soft and hard tissues references. The outcomes of selected studies were various, with a low quality of evidence, and they did not allow to infer a stable cranial relation between the occlusal plane and other bone structures. CONCLUSIONS: The evidence does not support that the interpupillary plane represent a reliable parameter to evaluate the occlusal plane orientation in a frontal view; instead, the Frankfurt plane could be a much more stable reference parameter, from a morphological perspective. It is necessary to perform an observational study upon craniums to define which are the most stable cranial reference planes to determine the orientation of the occlusal plane in dentate subjects.


Assuntos
Oclusão Dentária , Pavilhão Auricular , Humanos , Cefalometria/métodos , Face/anatomia & histologia , Crânio/diagnóstico por imagem , Estudos Observacionais como Assunto
2.
Am J Dent ; 31(4): 199-204, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30106536

RESUMO

PURPOSE: To evaluate the in vitro effects of the Composite Primer and different surface treatments on the shear bond strength (SBS) of acrylic and bis-acryl repairs with resin composite (RC). METHODS: Acrylic (Alike) and bis-acryl (Protemp 4) blocks were prepared. Surface roughness was standardized (0.16 µm) and grit blasting was applied to half of the samples. Blocks were divided randomly into groups according to surface treatment [methyl methacrylate monomer (MMA) for 180 seconds or bonding agents (Composite Primer and Scotchbond Multi Purpose), applied alone or following MMA]. Two consistencies of RC [ regular (Filtek Z350XT and Solare composite) or flowable (Filtek Z350XT flowable and G-aenial flowable composite) ] were used to test bond repair. Cylinders (2 mm diameter) of each RC (n= 10/group) were attached to the block surface, and SBS was measured using a universal testing machine at 0.5 mm/minute. Failure (adhesive, cohesive or mixed) was assessed under ×3.5 magnification. SBS data were analyzed using factorial ANOVA, followed by Tukey post-hoc, and Weibull moduli estimation (α = 0.05). RESULTS: The highest SBS, Weibull modulus (m) and scale parameter (σ0) were found in combined use of MMA and bonding agents (P< 0.001), regardless of the substrate, RC consistency or brand. The use of the Composite Primer and flowable RC also increased SBS (P< 0.001). Significant interaction between surface treatment and RC consistency was observed for the PMMA substrate (P< 0.001). Sandblasting did not influence SBS (P> 0.05). Adhesive failure was most prevalent (93.5%) and SBS values were significantly higher in mixed fractures (19.2± 3.8 MPa) compared to the adhesive ones (9.7± 6.0 MPa) (P< 0.001). No cohesive fracture was observed. CLINICAL SIGNIFICANCE: Composite Primer improved the adhesion of acrylic and bis-acryl repairs, especially when a flowable composite was used. When such product is not available, the combined use of MMA and a bonding agent is necessary, increasing the number of clinical steps, cost, and time required.


Assuntos
Resinas Acrílicas , Colagem Dentária , Cimentos de Resina , Resinas Compostas , Análise do Estresse Dentário , Teste de Materiais , Polimetil Metacrilato , Distribuição Aleatória , Resistência ao Cisalhamento , Propriedades de Superfície
3.
Braz Dent J ; 26(4): 325-36, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26312967

RESUMO

Lack of standard criteria in the outcome assessment makes it difficult to draw conclusions on the clinical performance of short implants and, under these circumstances, determine the reasons for implant failure. This study evaluated, through a systematic review of the literature and meta-analysis, the essential parameters required to assess the long-term clinical performance of short and extra-short implants. Electronic databases (Pubmed-MEDLINE, Cochrane Library Database, Embase, and Lilacs) were searched by two independent reviewers, without language limitation, to identify eligible papers. References from the selected articles were also reviewed. The review included clinical trials involving short dental implants placed in humans, published between January 2000 and March 2014, which described the parameters applied for outcome's measurements and provided data on survival rates. Thirteen methodologically acceptable studies were selected and 24 parameters were identified. The most frequent parameters assessed were the marginal bone loss and the cumulative implant survival rate, followed by implant failure rate and biological complications such as bleeding on probing and probing pocket depths. Only cumulative implant survival rate data allows meta-analysis revealing a positive effect size (from 0.052 (fixed) to 0.042 (random)), which means that short implant appears to be a successful treatment option. Mechanical complications and crown-to-implant (C/I) ratio measurement were also commonly described, however, considering the available evidence; no strong conclusions could be drawn since different methods were used to assess each parameter. By means of this literature review, a standard evaluation scheme is proposed, being helpful to regiment further investigations and comparisons on future studies.


Assuntos
Implantes Dentários , Ensaios Clínicos como Assunto , Humanos
4.
Braz. dent. j ; Braz. dent. j;26(4): 325-336, July-Aug. 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-756393

RESUMO

Lack of standard criteria in the outcome assessment makes it difficult to draw conclusions on the clinical performance of short implants and, under these circumstances, determine the reasons for implant failure. This study evaluated, through a systematic review of the literature and meta-analysis, the essential parameters required to assess the long-term clinical performance of short and extra-short implants. Electronic databases (Pubmed-MEDLINE, Cochrane Library Database, Embase, and Lilacs) were searched by two independent reviewers, without language limitation, to identify eligible papers. References from the selected articles were also reviewed. The review included clinical trials involving short dental implants placed in humans, published between January 2000 and March 2014, which described the parameters applied for outcome's measurements and provided data on survival rates. Thirteen methodologically acceptable studies were selected and 24 parameters were identified. The most frequent parameters assessed were the marginal bone loss and the cumulative implant survival rate, followed by implant failure rate and biological complications such as bleeding on probing and probing pocket depths. Only cumulative implant survival rate data allows meta-analysis revealing a positive effect size (from 0.052 (fixed) to 0.042 (random)), which means that short implant appears to be a successful treatment option. Mechanical complications and crown-to-implant (C/I) ratio measurement were also commonly described, however, considering the available evidence; no strong conclusions could be drawn since different methods were used to assess each parameter. By means of this literature review, a standard evaluation scheme is proposed, being helpful to regiment further investigations and comparisons on future studies.

.

A falta de critérios padronizados para a avaliação dos resultados faz com que seja difícil tirar conclusões sobre o desempenho clínico dos implantes curtos e, nestas circunstâncias, determinar as razões para o fracasso do implante. Este estudo avaliou, através de uma revisão sistemática da literatura, os parâmetros essenciais necessários para avaliar o desempenho clínico em longo prazo de implantes curtos e extra-curtos. Bases de dados eletrônicas (PubMed-MEDLINE, Base de dados da Biblioteca Cochrane, Embase e Lilacs) foram avaliadas por dois revisores independentes, sem limitação da linguagem, de modo a identificar artigos elegíveis. As referências dos artigos selecionados foram também analisadas. A revisão incluiu estudos clínicos, publicados entre janeiro de 2000 e março de 2014, envolvendo implantes dentais curtos, instalados em seres humanos, nos quais foram descritos os parâmetros utilizados para mensuração dos resultados e fornecidos dados sobre as taxas de sobrevivência. Treze estudos metodologicamente aceitáveis foram selecionados, sendo identificados 24 parâmetros. Os parâmetros avaliados com maior frequencia foram a perda óssea marginal e a taxa cumulativa de sobrevivência do implante, seguida pela taxa de falha dos implantes e complicações biológicas, tais como sangramento à sondagem e profundidade de sondagem. Apenas a taxa cumulativa de sobrevivência dos implantes permitiu a meta-análise revelando efeito positivo (variação de 0.052 (efeito fixo) até 0.042 (efeito aleatório)), demonstrando que os implantes curtos parecem ser uma opção de tratamento bem sucedida. Complicações mecânicas e a mensuração da proporção coroa-implante foram também referidas, entretanto, considerando-se as evidências disponíveis, não se pode chegar a fortes conclusões, pois diferentes métodos foram utilizados para avaliar cada parâmetro. Por meio desta revisão da literatura, um esquema padronizado de avaliação é proposto, sendo útil para arregimentar ...


Assuntos
Humanos , Implantes Dentários , Ensaios Clínicos como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA