Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Rev. Bras. Ortop. (Online) ; 59(3): 449-455, May-June 2024. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1569772

RESUMO

Abstract Objective To evaluate surgeons' performance in resecting CAM-type deformities using a realistic arthroscopic surgery simulator. Methods An arthroscopic simulator was created using low-cost materials with the help of a GTMax Core A1 3D printer and the programs Invesalius and Meshmixer 2017, which were used to develop femoral head parts in ABS material, with the presence of a CAM-type deformity, to mimic a femoroacetabular impact situation. After the operations were performed by 16 surgeons, the femurs were compared to a previous model with deformity and another without, using Cloudcompare, and parameters such as the volumetric difference between the operated femurs, with and without deformity, the minimum and maximum distance between them, the percentage of the deformity resected, the estimated time for total resection of the deformity, as well as a qualitative analysis based on the images and graphs provided by the program representing the areas of the parts resected, were evaluated at the end. Results The average resection speed was 34.66 mm3/min (SD = 46 mm3/min, max = 147.33; min = −2.66). The average resection rate was 26.2% (SD = 34.7%, max = 111; min = −2). Qualitative analysis showed hyporesection of deformities and sometimes hyperresection of nondeformed areas. The simulator was highly rated by the surgeons, with a tactile sensation very similar to real surgery, according to them. Conclusion Arthroscopic simulators have proved very useful in training less experienced surgeons.


Resumo Objetivo Avaliar o desempenho de cirurgiões na ressecção de deformidades tipo CAME fazendo uso de um simulador realista de cirurgia artroscópica. Métodos Um simulador artroscópico foi criado a partir de materiais de baixo custo com auxílio de uma impressora 3D GTMax Core A1 e dos programas Invesalius e Meshmixer 2017, que foram utilizados para criar peças de cabeça de fêmur em material ABS, com a presença de uma deformidade tipo CAME, a fim de mimetizar uma situação de impacto femoroacetabular. Após as operações serem realizadas por 16 cirurgiões, os fêmures foram comparados a um modelo prévio com e outro sem deformidade pelo programa Cloudcompare, sendo avaliados ao final parâmetros como diferença volumétrica entre os fêmures operados, com e sem deformidade, distância mínima e máxima entre eles, porcentagem da deformidade ressecada, tempo estimado para ressecção total da deformidade, além de uma análise qualitativa feita com base nas imagens e gráficos fornecidos pelo programa representando as áreas das peças efetivamente ressecadas. Resultados A velocidade média de resseção foi de 34,66mm3/minuto (DP = 46 mm3/min, max = 147,33 mm3/min; min = −2,66 mm3/min). A média de ressecção obtida foi de 26,2% (DP = 34,7%, max = 111%; min = −2%). A análise qualitativa demonstrou uma hiporresecção das deformidades e, por vezes, hiperresecção de áreas não deformadas. O simulador foi muito bem avaliado pelos cirurgiões, tendo uma sensação tátil bem semelhante à cirurgia real segundo os mesmos. Conclusão Simuladores artroscópicos se mostraram muito úteis no treinamento de cirurgiões menos experientes.


Assuntos
Humanos , Artroscopia , Impacto Femoroacetabular , Treinamento por Simulação , Quadril
2.
Rev Bras Ortop (Sao Paulo) ; 59(3): e449-e455, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38911881

RESUMO

Objective To evaluate surgeons' performance in resecting CAM-type deformities using a realistic arthroscopic surgery simulator. Methods An arthroscopic simulator was created using low-cost materials with the help of a GTMax Core A1 3D printer and the programs Invesalius and Meshmixer 2017, which were used to develop femoral head parts in ABS material, with the presence of a CAM-type deformity, to mimic a femoroacetabular impact situation. After the operations were performed by 16 surgeons, the femurs were compared to a previous model with deformity and another without, using Cloudcompare, and parameters such as the volumetric difference between the operated femurs, with and without deformity, the minimum and maximum distance between them, the percentage of the deformity resected, the estimated time for total resection of the deformity, as well as a qualitative analysis based on the images and graphs provided by the program representing the areas of the parts resected, were evaluated at the end. Results The average resection speed was 34.66 mm 3 /min (SD = 46 mm 3 /min, max = 147.33; min = -2.66). The average resection rate was 26.2% (SD = 34.7%, max = 111; min = -2). Qualitative analysis showed hyporesection of deformities and sometimes hyperresection of nondeformed areas. The simulator was highly rated by the surgeons, with a tactile sensation very similar to real surgery, according to them. Conclusion Arthroscopic simulators have proved very useful in training less experienced surgeons.

3.
Artigo em Inglês | MEDLINE | ID: mdl-22289073

RESUMO

The knowledge of contact forces in teeth surfaces during mastication or para-functional movements can help to understand processes related to friction and wear of human dental enamel. The development of a numerical model for analysis of the occlusal contact between two antagonistic teeth is proposed, which includes three basic steps: the characterisation of the surface roughness, its homogenisation using an assumed distribution function and the numerical determination of the resulting forces. Finite element strain results for the main different asperities are statistically combined, deriving the predicted macroscopic behaviour of the interface. Axisymmetric and 3D numerical models with an elasto-plastic constitutive law are used to simulate micro-indentations and micro-contacts, respectively. The contact is allowed to occur locally in planes not necessarily parallel to the surface's mean plane, a problem for which there is no analytical solution. The three identified parameters, homogenised surface hardness (3.68 GPa), surface yield stress (3.08 GPa) and static friction coefficient (0.23), agree with the experimental values reported in the literature.


Assuntos
Oclusão Dentária , Mastigação/fisiologia , Modelos Biológicos , Modelos Dentários , Força de Mordida , Esmalte Dentário , Humanos , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA