1.
Int J Radiat Biol ; 99(3): 431-438, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35759221

RESUMO

PURPOSE: To test the performance of different algorithms that can be used in inter-laboratory comparisons based on dicentric chromosome analysis, and to evaluate the impact of considering a priori values different to calculate individual laboratory performance based on the ionizing radiation dose estimation. METHODS: Mean and standard deviation estimations in inter-laboratory comparisons are tested on simulated data and data from previously published inter-laboratory comparisons using three robust algorithms, Algorithm A, Algorithm B and Q/Hampel, all programmed in R-project language and implemented in a Shiny application. The simulated data were generated assuming three different probabilities to contaminate inter-laboratory comparisons samples with atypical dose values. Comparison between different algorithms was also done using published exercises where blood samples were irradiated at 0 and 0.7 Gy that represent a challenge for the assessment of an inter-laboratory comparison. RESULTS: The best performance was obtained with the Q/Hampel algorithm for the estimation of the dose mean and with the Algorithm B for the estimation of the dose standard deviation under the conditions tested in the simulations. The Q/Hampel algorithm showed the best performance when non-irradiated samples were evaluated and there was a high proportion of identical values. The presence identical values cause the Algorithm B to fail. Real examples illustrating the need to consider standard deviation priors, and the need to use algorithms resistant to a high proportion of identical values are presented. CONCLUSIONS: Q/Hampel algorithm is a serious candidate to estimate the dose mean in the inter-laboratory comparisons, and to estimate both parameters when the proportion of identical values equals or higher than the half of the results. When the proportion of identical values is less than the half of the results, the Algorithm B should be considered as a candidate to estimate the standard deviation in the inter-laboratory comparisons with small number of laboratories. We remark that special attention is needed to establish prior definitions of standard deviation in the assessment of inter-laboratory dicentric assay comparisons.


Assuntos
Bioensaio , Aberrações Cromossômicas , Humanos , Bioensaio/métodos , Radiação Ionizante
2.
Radiat Prot Dosimetry ; 172(1-3): 218-222, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27473695

RESUMO

Mitotic Index (MI) estimation expressed as percentage of mitosis plays an important role as quality control endpoint. To this end, MI is applied to check the lot of media and reagents to be used throughout the assay and also to check cellular viability after blood sample shipping, indicating satisfactory/unsatisfactory conditions for the progression of cell culture. The objective of this paper was to apply the CellProfiler open-source software for automatic detection of mitotic and nuclei figures from digitized images of cultured human lymphocytes for MI assessment, and to compare its performance to that performed through semi-automatic and visual detection. Lymphocytes were irradiated and cultured for mitosis detection. Sets of images from cultures were analyzed visually and findings were compared with those using CellProfiler software. The CellProfiler pipeline includes the detection of nuclei and mitosis with 80% sensitivity and more than 99% specificity. We conclude that CellProfiler is a reliable tool for counting mitosis and nuclei from cytogenetic images, saves considerable time compared to manual operation and reduces the variability derived from the scoring criteria of different scorers. The CellProfiler automated pipeline achieves good agreement with visual counting workflow, i.e. it allows fully automated mitotic and nuclei scoring in cytogenetic images yielding reliable information with minimal user intervention.


Assuntos
Bioensaio/métodos , Núcleo Celular/ultraestrutura , Interpretação de Imagem Assistida por Computador/métodos , Microscopia/métodos , Mitose/genética , Índice Mitótico/métodos , Radiometria/métodos , Núcleo Celular/efeitos da radiação , Mitose/efeitos da radiação , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Software
3.
J Radiat Res ; 55(5): 862-5, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24789085

RESUMO

The combination of automatic image acquisition and automatic image analysis of premature chromosome condensation (PCC) spreads was tested as a rapid biodosimeter protocol. Human peripheral lymphocytes were irradiated with (60)Co gamma rays in a single dose of between 1 and 20 Gy, stimulated with phytohaemaglutinin and incubated for 48 h, division blocked with Colcemid, and PCC-induced by Calyculin A. Images of chromosome spreads were captured and analysed automatically by combining the Metafer 4 and CellProfiler platforms. Automatic measurement of chromosome lengths allows the calculation of the length ratio (LR) of the longest and the shortest piece that can be used for dose estimation since this ratio is correlated with ionizing radiation dose. The LR of the longest and the shortest chromosome pieces showed the best goodness-of-fit to a linear model in the dose interval tested. The application of the automatic analysis increases the potential use of the PCC method for triage in the event of massive radiation causalities.


Assuntos
Bioensaio/métodos , Cromossomos Humanos/genética , Cromossomos Humanos/efeitos da radiação , Linfócitos/efeitos da radiação , Microscopia/métodos , Reconhecimento Automatizado de Padrão/métodos , Monitoramento de Radiação/métodos , Células Cultivadas , Cromossomos Humanos/ultraestrutura , Relação Dose-Resposta à Radiação , Humanos , Linfócitos/fisiologia , Linfócitos/ultraestrutura , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
J Radiat Res ; 54(5): 863-71, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23596200

RESUMO

The estimation of the dose and the irradiated fraction of the body is important information in the primary medical response in case of a radiological accident. The PCC-R assay has been developed for high-dose estimations, but little attention has been given to its applicability for partial-body irradiations. In the present work we estimated the doses and the percentage of the irradiated fraction in simulated partial-body radiation exposures at high doses using the PCC-R assay. Peripheral whole blood of three healthy donors was exposed to doses from 0-20 Gy, with 6°Co gamma radiation. To simulate partial body irradiations, irradiated and non-irradiated blood was mixed to obtain proportions of irradiated blood from 10-90%. Lymphocyte cultures were treated with Colcemid and Calyculin-A before harvest. Conventional and triage scores were performed for each dose, proportion of irradiated blood and donor. The Papworth's u test was used to evaluate the PCC-R distribution per cell. A dose-response relationship was fitted according to the maximum likelihood method using the frequencies of PCC-R obtained from 100% irradiated blood. The dose to the partially irradiated blood was estimated using the Contaminated Poisson method. A new D0 value of 10.9 Gy was calculated and used to estimate the initial fraction of irradiated cells. The results presented here indicate that by PCC-R it is possible to distinguish between simulated partial- and whole-body irradiations by the u-test, and to accurately estimate the dose from 10-20 Gy, and the initial fraction of irradiated cells in the interval from 10-90%.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas/efeitos da radiação , Análise Citogenética/métodos , Interpretação Estatística de Dados , Linfócitos/fisiologia , Linfócitos/efeitos da radiação , Contagem Corporal Total/métodos , Carga Corporal (Radioterapia) , Células Cultivadas , Relação Dose-Resposta à Radiação , Raios gama , Humanos , Linfócitos/citologia , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Irradiação Corporal Total/métodos
5.
Anal Quant Cytol Histol ; 34(2): 66-71, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22611761

RESUMO

OBJECTIVE: To test a CellProfiler pipeline for automated counting and characterization of gamma-H2AX foci in color images of human cultured cells. STUDY DESIGN: A431 cells were irradiated and stained for gamma-H2AX foci detection. Sets of color images were analyzed visually, and findings were compared with those using FociCounter and CellProfiler software. RESULTS: The CellProfiler pipeline includes some proprieties not present in FociCounter, such as the automatic detection of nuclei, the detection of touching nuclei and the rejection of nuclei that touch the border of the image. The time required for manual operation is associated with the number of images analyzed visually or by FociCounter but not for the CellProfiler program. CellProfiler reduced manual operation time and is about 4 times faster than semiautomatic detection using FociCounter and 10 times faster than visual counting. CONCLUSION: We conclude that CellProfiler and FociCounter are reliable tools for measuring gamma-H2AX foci. However, CellProfiler overcomes the limitations of the FociCounter program and is able to detect nuclei automatically, saving considerable manual operation.


Assuntos
Dano ao DNA/fisiologia , Histonas/metabolismo , Processamento de Imagem Assistida por Computador/métodos , Patologia Clínica/métodos , Neoplasias Cutâneas/patologia , Divisão Celular/efeitos da radiação , Linhagem Celular Tumoral , Núcleo Celular/patologia , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Patologia Clínica/instrumentação , Radiação Ionizante , Neoplasias Cutâneas/metabolismo , Software
6.
Cancer Biol Ther ; 13(2): 71-6, 2012 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-22231391

RESUMO

Epidermal growth factor receptors (EGFR) are overexpressed in a wide range of malignancies including head and neck, colon, and breast cancers. It has been identified that carcinomas with high expression levels of EGFR are more resistant to radiotherapy. Therefore, inhibiting nuclear translocation of EGFR to increase the radiosensitivity of malignant cells expressing EGFR offers the potential for increasing the therapeutic index of radiotherapy. The purpose of the present study was to quantify and to compare the radiosensitizing properties of the well-known anti-EGFR antibodies, cetuximab and nimotuzumab in human epidermoid A431 overexpressing EGFR cells. Cells were treated with two concentrations of the antibodies and then irradiated with a single dose of 4 Gy. The results indicated that the two antibodies induced radiosensitization increasing the percentage of dead/dying cells and the yield of γ-H2AX foci 24 h after irradiation. Whereas cetuximab exhibited a significant increase in radiosensitization at the highest concentration, the effects of nimotuzumab were more modest. A correlation between γ-H2AX foci signals and dead/dying cells was observed. The disparity in modulation of radiation-induced DNA damage by the two antibodies could be associated with the level of their respective intrinsic cytotoxic properties. Overall, the findings highlight the potential therapeutic benefit of combination therapy with anti-EGFR antibodies and radiotherapy for relevant carcinomas.


Assuntos
Anticorpos Monoclonais Humanizados/uso terapêutico , Anticorpos Monoclonais/uso terapêutico , Antineoplásicos/uso terapêutico , Carcinoma de Células Escamosas/terapia , Receptores ErbB/antagonistas & inibidores , Radiossensibilizantes/uso terapêutico , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/radioterapia , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos da radiação , Cetuximab , Terapia Combinada , Dano ao DNA/efeitos dos fármacos , Dano ao DNA/efeitos da radiação , Receptores ErbB/imunologia , Histonas/metabolismo , Humanos , Tolerância a Radiação/efeitos dos fármacos , Radiação Ionizante