Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Scand J Clin Lab Invest ; 78(7-8): 556-559, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30278778

RESUMO

Oxidative stress biomarkers of oral and systemic diseases can be found in saliva. However, there is no uniformity for the saliva collection time in these kinds of analyses and saliva composition may change because of mechanical stimulation. Therefore, the aim of this work was to determine the effect of mechanical stimulation for 10 min on the concentrations of vitamin C, vitamin E, total antioxidants and total oxidants in saliva. Saliva samples from individuals of both sexes, aged between 18 and 38 years, were collected for 10 min at 2 minintervals. Saliva flow rate in each 2 min period was measured, as well the total oxidant state, the total antioxidant capacity, vitamin C and vitamin E concentrations. All analyses were performed in triplicate and were determined using colorimetric tests. The results were analysed using t-test, Friedman's test and analysis of variance (ANOVA) for repeated measures. Mauchly's sphericity test was applied and, if necessary, technical corrections were made using the Greenhouse-Geisser test. We found no significant difference between the amounts of saliva produced across the collection times. Total oxidant status, total antioxidant capacity, vitamin C and vitamin E concentrations remained stable. Based on our findings, saliva can be collected for 10 min or less with masticatory stimulation without any variations in the concentration of the variables analysed. However, we suggest using saliva samples after two minutes of mechanical stimulation.


Assuntos
Antioxidantes/metabolismo , Ácido Ascórbico/metabolismo , Oxidantes/metabolismo , Saliva/metabolismo , Vitamina E/metabolismo , Adolescente , Adulto , Análise de Variância , Feminino , Humanos , Masculino , Estresse Oxidativo , Estimulação Física , Fatores de Tempo
2.
J Appl Oral Sci ; 26: e20160662, 2018 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-29364336

RESUMO

The main goal of this study was to compare the polymerization degree of bulk-fill giomer resin cured with three different light-curing units (LCUs): a polywave third-generation (Valo); a monowave (DemiUltra: DU); and a second-generation LED (Optima 10: Opt) LCUs by using structural and mechanical properties. Giomer samples of 2 and 4 mm cured with three LCUs were employed in vitro analysis. The degree of curing (DC%) was determined with Fourier-Transform Infrared Spectroscopy (FTIR). Microstructural features were observed with scanning electron microscopy (SEM). Flexural strength (FS), compression strength (CS), elastic modulus and fracturing strain were determined for mechanical properties. Surface microhardness (SMH) values were also measured. Oneway ANOVA, two-way analysis of variance and Tukey multiple comparison tests were used for statistically analyzing the FS and SMH. DC% values were 58.2, 47.6, and 39.7 for the 2 mm samples cured with DU, Opt., and Valo LCUs, respectively. DC% values of the 4 mm samples were 50.4, 44.6, and 38.2 for DU, Opt, and Valo, respectively. SMH values were Valo, Opt

Assuntos
Bis-Fenol A-Glicidil Metacrilato/química , Bis-Fenol A-Glicidil Metacrilato/efeitos da radiação , Resinas Compostas/química , Resinas Compostas/efeitos da radiação , Cura Luminosa de Adesivos Dentários/métodos , Polimerização/efeitos da radiação , Análise de Variância , Força Compressiva , Módulo de Elasticidade , Testes de Dureza , Teste de Materiais , Microscopia Eletrônica de Varredura , Valores de Referência , Reprodutibilidade dos Testes , Espectroscopia de Infravermelho com Transformada de Fourier , Estatísticas não Paramétricas , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo
3.
J. appl. oral sci ; J. appl. oral sci;26: e20160662, 2018. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893738

RESUMO

ABSTRACT Objective: The main goal of this study was to compare the polymerization degree of bulk-fill giomer resin cured with three different light-curing units (LCUs): a polywave third-generation (Valo); a monowave (DemiUltra: DU); and a second-generation LED (Optima 10: Opt) LCUs by using structural and mechanical properties. Material and methods: Giomer samples of 2 and 4 mm cured with three LCUs were employed in vitro analysis. The degree of curing (DC%) was determined with Fourier-Transform Infrared Spectroscopy (FTIR). Microstructural features were observed with scanning electron microscopy (SEM). Flexural strength (FS), compression strength (CS), elastic modulus and fracturing strain were determined for mechanical properties. Surface microhardness (SMH) values were also measured. Oneway ANOVA, two-way analysis of variance and Tukey multiple comparison tests were used for statistically analyzing the FS and SMH. Results: DC% values were 58.2, 47.6, and 39.7 for the 2 mm samples cured with DU, Opt., and Valo LCUs, respectively. DC% values of the 4 mm samples were 50.4, 44.6, and 38.2 for DU, Opt, and Valo, respectively. SMH values were Valo, Opt<DU at top of the samples; Valo<DU, Opt at 2 mm, and DU, Valo<Opt at 4 mm depth. Giomer samples cured with Opt and DU exhibited higher FS values than Valo. CS values were similar but compressive modulus and fracturing strain (%) varied depending on the curing protocol. Conclusions: Based on the results, it can be concluded that curing device and protocol strongly affect crosslinking reactions and thus DC%, SMH, compressive modulus and strain at break values. Consequently, it can be deduced that curing protocol is possibly the most important parameter for microstructure formation of highly-filled composite restoratives because it may bring some structural defects and physical frailties on restorations due to lower degree of polymerization.


Assuntos
Bis-Fenol A-Glicidil Metacrilato/efeitos da radiação , Bis-Fenol A-Glicidil Metacrilato/química , Resinas Compostas/efeitos da radiação , Resinas Compostas/química , Cura Luminosa de Adesivos Dentários/métodos , Polimerização/efeitos da radiação , Valores de Referência , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Análise de Variância , Espectroscopia de Infravermelho com Transformada de Fourier , Estatísticas não Paramétricas , Força Compressiva , Módulo de Elasticidade , Testes de Dureza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA