Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Braz Dent J ; 34(2): 67-74, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37194858

RESUMO

The objective of this work was to evaluate the mechanical performance of Z350 resin composite modified with Bombyx mori cocoons silk nanoparticles for dental applications. Four experimental groups were analyzed G0% = Filtek Z350 resin composite (control); G1% = Filtek Z350 with 1% of silk nanoparticles; G3% = Filtek Z350 with 3% of silk nanoparticles; G5% = Filtek Z350 with 5% of silk nanoparticles. It was employed scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction, 3-point flexural strength test, Knoop hardness test, and surface roughness. From 3-point flexural strength tests the control group presented the best results G0% = 113.33 MPa (±23.73). The higher flexural modulus was shown by groups G3% = 29.150 GPa (±5.191) and G5% = 34.101 GPa (±7.940), which are statistically similar. The Knoop microhardness test has shown statistical difference only among the G3% group between the top 80.78 (± 3.00) and bottom 68.80 (±3.62) and no difference between the groups. The roughness test presented no statistical difference between the groups. The incorporation of silk nanoparticles reduced the flexural strength of Z350 resin composite. The surface roughness and microhardness tests showed no changes in any of the groups studied.


Assuntos
Bombyx , Nanopartículas , Animais , Seda , Dureza , Teste de Materiais , Resinas Compostas/química , Propriedades de Superfície , Materiais Dentários/química
2.
Braz. dent. j ; Braz. dent. j;34(2): 67-74, Mar.-Apr. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1439572

RESUMO

Abstract The objective of this work was to evaluate the mechanical performance of Z350 resin composite modified with Bombyx mori cocoons silk nanoparticles for dental applications. Four experimental groups were analyzed G0% = Filtek Z350 resin composite (control); G1% = Filtek Z350 with 1% of silk nanoparticles; G3% = Filtek Z350 with 3% of silk nanoparticles; G5% = Filtek Z350 with 5% of silk nanoparticles. It was employed scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction, 3-point flexural strength test, Knoop hardness test, and surface roughness. From 3-point flexural strength tests the control group presented the best results G0% = 113.33 MPa (±23.73). The higher flexural modulus was shown by groups G3% = 29.150 GPa (±5.191) and G5% = 34.101 GPa (±7.940), which are statistically similar. The Knoop microhardness test has shown statistical difference only among the G3% group between the top 80.78 (± 3.00) and bottom 68.80 (±3.62) and no difference between the groups. The roughness test presented no statistical difference between the groups. The incorporation of silk nanoparticles reduced the flexural strength of Z350 resin composite. The surface roughness and microhardness tests showed no changes in any of the groups studied.


Resumo O objetivo deste trabalho foi avaliar o desempenho mecânico da resina composta Z350 modificada com nanopartículas de seda Bombyx mori cocoons para aplicações odontológicas. Quatro grupos experimentais foram analisados: G0%) Resina Z350 apenas (grupo controle); G1%) Reforço com 1% de nanopartículas de seda; G3%) Reforço com 3% de nanopartículas de seda; e G5%) Reforço com 5% de nanopartículas de seda. Foi empregado microscopia eletrônica de varredura, espectroscopia de energia dispersiva de raios X, difração de raios X, teste de resistência à flexão de 3 pontos, teste de dureza Knoop e rugosidade superficial. Nos testes de resistência à flexão de 3 pontos o grupo controle apresentou melhores resultados G0% = 0.113 GPa (±0.024). O maior módulo de flexão foi demonstrado pelos grupos G3% = 29.151GPa (±5.191) e G5% = 34.102 GPa (±7.94), que são estatisticamente semelhantes. O teste de microdureza Knoop mostrou diferença estatística apenas entre o grupo G3% entre os 80.78 superiores (± 3.00) e os 68.80 inferiores (±3.62). Não há diferença entre os grupos. O teste de rugosidade não apresentou diferença estatística entre os grupos. A incorporação de nanopartículas de seda reduziu a resistência à flexão da resina composta Z350. Os testes de rugosidade superficial e microdureza não apresentaram alterações em nenhum dos grupos estudados.

3.
Braz. dent. j ; Braz. dent. j;33(3): 99-108, July-Sept. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1384038

RESUMO

Abstract This study showed the synthesis of Glass ionomer cements (GIC) modified with calcium phosphate nanoparticles (nCaP). The nCaP/GIC were submitted to mechanical compression and diametral tensile tests. The biocomposite were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD) and Fourier-transform infrared spectroscopy (FTIR). Cytotoxicity and cell viability tests were performed on the human bone marrow mesenchymal stem cells using a 3-(4,5-dimethylthiazol-2yl)2,5-diphenyl- tetrazolium-bromide assay and LIVE/DEAD assays. Statistically significant differences were observed for mechanical properties (Kruskal-Wallis, p<0.001), nCaP/GIC showed higher resistance to compression and diametral traction. The SEM analyses revealed a uniform distribution nCaP in the ionomer matrix. The EDX and XRD results indicated that hydroxyapatite and calcium β-triphosphate phases. The FTIR spectra revealed the asymmetric band of ν3PO43- between 1100-1030cm-1 and the vibration band associated with ν1PO43- in 963cm-1 associated with nCaP. The nCaP/GIC presented response to adequate cell viability and non-cytotoxic behavior. Therefore, the new nCaP/GIC composite showed great mechanical properties, non-cytotoxic behavior, and adequate response to cell viability with promising dental applications.


Resumo Este estudo apresenta a síntese de cimentos de ionômero de vidro (GIC) modificados com nanopartículas de fosfato de cálcio (nCaP). Os nCaP / GIC foram submetidos a ensaios mecânicos de compressão e tração diametral. Os biocompósitos foram caracterizados por microscopia eletrônica de varredura (MEV), espectroscopia de energia dispersiva de raios-X (EDX), difração de raios-X (XRD) e espectroscopia de infravermelho com transformada de Fourier (FTIR). Os testes de citotoxicidade e viabilidade celular foram realizados em células-tronco mesenquimais da medula óssea humana usando um ensaio de 3- (4,5-dimetiltiazol-2-il) 2,5-difeniltetrazólio-brometo e ensaios LIVE / DEAD. Diferenças estatisticamente significativas foram observadas para as propriedades mecânicas (Kruskal-Wallis, p <0,001), nCaP / GIC apresentou maior resistência à compressão e tração diametral. As análises de SEM revelaram uma distribuição uniforme de nCaP na matriz do ionômero. Os resultados de EDX e DRX indicaram fases de hidroxiapatita e β-trifosfato de cálcio. Os espectros de FTIR revelaram a banda assimétrica de ν3PO4 3- entre 1100-1030cm-1 e a banda de vibração associada a ν1PO4 3- em 963cm-1 associada a nCaP. O nCaP / GIC apresentou resposta adequada à viabilidade celular e comportamento não citotóxico. Portanto, o novo compósito nCaP / GIC apresentou ótimas propriedades mecânicas, comportamento não citotóxico e resposta adequada à viabilidade celular com promissoras aplicações odontológicas.

4.
Braz Dent J ; 33(3): 99-108, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35766723

RESUMO

This study showed the synthesis of Glass ionomer cements (GIC) modified with calcium phosphate nanoparticles (nCaP). The nCaP/GIC were submitted to mechanical compression and diametral tensile tests. The biocomposite were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD) and Fourier-transform infrared spectroscopy (FTIR). Cytotoxicity and cell viability tests were performed on the human bone marrow mesenchymal stem cells using a 3-(4,5-dimethylthiazol-2yl)2,5-diphenyl- tetrazolium-bromide assay and LIVE/DEAD assays. Statistically significant differences were observed for mechanical properties (Kruskal-Wallis, p<0.001), nCaP/GIC showed higher resistance to compression and diametral traction. The SEM analyses revealed a uniform distribution nCaP in the ionomer matrix. The EDX and XRD results indicated that hydroxyapatite and calcium ß-triphosphate phases. The FTIR spectra revealed the asymmetric band of ν3PO43- between 1100-1030cm-1 and the vibration band associated with ν1PO43- in 963cm-1 associated with nCaP. The nCaP/GIC presented response to adequate cell viability and non-cytotoxic behavior. Therefore, the new nCaP/GIC composite showed great mechanical properties, non-cytotoxic behavior, and adequate response to cell viability with promising dental applications.


Assuntos
Nanocompostos , Nanopartículas , Durapatita/química , Cimentos de Ionômeros de Vidro/química , Cimentos de Ionômeros de Vidro/toxicidade , Humanos , Teste de Materiais , Nanocompostos/química , Nanocompostos/toxicidade , Nanopartículas/química
5.
Biosci. j. (Online) ; 38: e38055, Jan.-Dec. 2022. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1396425

RESUMO

To evaluate the effect of ellagic acid on the inhibition of matrix metalloproteinase by analyzing the quality of the adhesive interface with bond strength measures in periods of 24 hours and six months of storage. Method: 40 healthy human third molars were prepared with class I cavities (5x4x3mm). The teeth were divided into four experimental groups: Group 1- without application of ellagic acid and storage time of 24 hours; Group 2- with ellagic acid/24 hours; G3- without ellagic acid/six months; Group 4- with ellagic acid/six months. Then, the cavities were restored with Single Bond Universal adhesive and Z350 composite resin, with and without the previous application of ellagic acid. Subsequently, hourglass-shaped specimens were obtained and subjected to the bond strength (BS) test (n = 10) in a universal testing machine. The bond test was performed after 24 hours and six months of storage. For the standard evaluation (n = 3) the samples were infiltrated with silver nitrate and placed in a developing solution for analysis in a Scanning Electron Microscope (SEM). The data obtained were analyzed with the Kruskal-Wallis non-parametric test, showing a statistically significant difference. Results: The highest bond strength values were found for the 24-hour groups followed by the groups with six months of storage. For nano-infiltration, groups G1 and G2 showed lower infiltration than groups G3 and G4. Conclusion: The previous application of ellagic acid did not affect the BS of the adhesive interface of the adhesive system analyzed, regardless of storage time.


Assuntos
Metaloproteinases da Matriz , Cimentos Dentários , Ácido Elágico
6.
Int. j. odontostomatol. (Print) ; 14(4): 658-663, dic. 2020. tab
Artigo em Inglês | LILACS | ID: biblio-1134554

RESUMO

ABSTRACT: Orthodontic accessories bonding in tooth enamel has been a critical step since the introduction of direct bonding techniques due to the importance of bracket stability. The aim of this study was to evaluate adhesion strength of different adhesive systems used for bracket bonding on dental surface. The present in vitro study was made from the analysis of shear strength of steel and ceramic brackets bonding with six different types of orthodontic adhesives. The brackets were bonded to 120 human extracted first premolar teeth with Orthocem®, Orthocem® + Ambar Universal® primer, Orthobond Plus®, Biofix®, Transbond XT®, Ortholink VLC®. Shear strength tests were performed on a universal testing machine EZ-Test-Shimadzu® and the data were analyzed using ANOVA test with Post-Hoc Bonferroni and 95 % statistical significance (p <0.05). Transbond XT® and Ortholink VLC® resin values showed greater shear resistance for steel brackets bonding and Transbond XT® and Orthobond Plus® adhesives showed better adhesion results for ceramic brackets bonding.


RESUMEN: La unión de accesorios de ortodoncia en el esmalte dental ha sido un paso crítico desde la introducción de las técnicas de unión directa debido a la importancia de la estabilidad del soporte. El objetivo de este estudio fue evaluar la fuerza de adhesión de diferentes sistemas adhesivos utilizados para la unión de brackets en la superficie dental. El presente estudio in vitro se realizó a partir del análisis de la resistencia al corte de brackets de acero y de cerámica unidos con seis tipos diferentes de adhesivos de ortodoncia. Los brackets se unieron a 120 primeros premolares extraídos con los adhesivos Orthocem®, Orthocem® + Ambar Universal® primer, Orthobond Plus®, Biofix®, Transbond XT®, Ortholink VLC®. Las pruebas de resistencia al corte se realizaron en una máquina de prueba universal EZ-Test-Shimadzu® y los datos se analizaron usando la prueba ANOVA con Bonferroni Post-Hoc y 95 % de significación estadística (p <0,05). Los valores de resina Transbond XT® y Ortholink VLC® mostraron una mayor resistencia al corte para la unión de brackets de acero y los adhesivos Transbond XT® y Orthobond Plus® mostraron mejores resultados de adhesión para la unión de brackets cerámicos.


Assuntos
Humanos , Colagem Dentária/métodos , Braquetes Ortodônticos , Cimentos Dentários , Ortodontia , Aço Inoxidável , Teste de Materiais , Cerâmica , Cimentos de Resina , Resistência ao Cisalhamento
7.
J. health sci. (Londrina) ; 21(1)30/04/2019.
Artigo em Inglês | LILACS | ID: biblio-995924

RESUMO

The aim of this study was to evaluate the surface roughness of a silorane and methacrylate-based composite resins subjected to different finishing/polishing techniques. Twelve disk specimens were prepared from each composite resin: P90®, Z350® and Charisma, divided into 12 groups according to the finishing/polishing technique: no finishing/polishing (control); finishing with 1112 FF diamond burs; finishing with 1112 FF diamond burs associated to Enhance/Pogo; finishing with 1112 FF diamond burs associated to Enhance/Pogo/Polishing/Poli I and II pastes/Fotogloss. After initial readouts of surface roughness, the specimens were subjected to mechanical cycling (1.200.000 cycles) and immediately subjected to final roughness readouts. Surface roughness means was statistically analyzed by ANOVA and Tukey-Kramer test (α=0.05). SEM images were realized after finishing/polishing and after mechanical cycling. The P90 composite showed surface roughness values similar to other investigated composites. However, significant difference was observed in finishing/polishing techniques. The diamond burs group showed the highest surface roughness differing from the other composite resins (α < 0.05). Enance/Pogo showed the lowest results, which presented no difference compared to the polishing paste group (α > 0.05). The low-shrink posterior restorative showed similar surface roughness when compared to dimethacrylate composite resins and suitable to posterior restorations. (AU).


O objetivo deste estudo foi avaliar a rugosidade superficial de resinas compostas à base silorano e metacrilato submetidas a diferentes técnicas de acabamento/polimento. Foram preparadas 12 amostras de disco de cada resina composta: P90®, Z350® e Carisma, divididas em 12 grupos de acordo com a técnica de acabamento / polimento: sem acabamento / polimento (controle); acabamento com ponta diamantada 1112 FF; acabamento com ponta diamantada 1112 FF associada a Enhance / Pogo; acabamento com ponta diamantada 1112 FF associada a Enhance / Pogo / Polishing / Pastas Poli I e II / Fotogloss. Após as leituras iniciais da rugosidade da superfície, os espécimes foram submetidos a ciclos mecânicos (1.200.000 ciclos) e submetidos imediatamente a leituras de rugosidade final. As medias de rugosidade superfícial foram analisadas estatisticamente por ANOVA e teste de Tukey-Kramer (α = 0,05). As imagens de MEV foram realizadas após o acabamento / polimento e após a ciclagem mecânica. O compósito P90 mostrou valores de rugosidade superficial semelhantes a outros compósitos investigados. Tough, mostrou diferença significativa nas técnicas de acabamento / polimento. O grupo de pontas damantadas apresentou maior rugosidade superficial que diferiu das outras resinas compostas (α <0,05). Enance / Pogo mostrou os menores resultados, que não apresentaram diferença em relação ao grupo de pasta de polimento (α> 0,05). O material restaurador posterior de baixa contração apresentou rugosidade superficial semelhante quando comparado as resinas compostas de dimetacrilato e são restaurações adequadas para região posterior. (AU).

8.
Braz Oral Res ; 32: e95, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30231170

RESUMO

The aim of the present study was to evaluate the prevalence and impact of malocclusion on oral health-related quality of life (OHRQoL) among schoolchildren aged 8 to 10 years and their parents in Diamantina, a town in the southeast of Brazil. A cross-sectional study was conducted with a sample of 390 randomly selected children who were subjected to a clinical oral examination. The Dental Aesthetic Index was used to diagnose malocclusion and the need for orthodontic treatment. The Child Perceptions Questionnaire (CPQ (8-10)) was used to evaluate the impact of malocclusion on OHRQoL. The children's parents answered the Brazilian Economic Criterion Questionnaire for the socioeconomic classification. Data analysis involved the nonparametric Kruskal-Wallis test and Spearman's correlation coefficients. The variables were grouped into a hierarchy of categories ranging from distal to proximal determinants. Poisson regression analysis with robust variance was performed at each level to correlate the total CPQ (8-10) score with the independent variables. The prevalence of malocclusion was 78.7%. Crossbite remained significantly associated with a negative impact on OHRQoL (PR = 1.28; 95%CI:1.17-1.39; p < 0.001). The prevalence of malocclusion was high in the sample investigated and exerted a negative impact on OHRQoL.


Assuntos
Má Oclusão/epidemiologia , Má Oclusão/fisiopatologia , Saúde Bucal/estatística & dados numéricos , Qualidade de Vida , Brasil/epidemiologia , Criança , Estudos Transversais , Cárie Dentária/epidemiologia , Cárie Dentária/fisiopatologia , Estética Dentária , Feminino , Humanos , Índice de Necessidade de Tratamento Ortodôntico , Masculino , Prevalência , Índice de Gravidade de Doença , Fatores Socioeconômicos , Estatísticas não Paramétricas , Inquéritos e Questionários
9.
Braz. j. oral sci ; 16: e17059, jan.-dez. 2017. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-883924

RESUMO

The aim of this study was to evaluate how acid-etching of the cavosurface enamel in Class I resin composite restorations influences the bond strength to the pulpal wall and the restoration, Knoop microhardness and nanoleakage after thermomechanical aging. For this research 76 fresh human molars were selected and restored with Silorane or Clearfil SEBond/Z350XT composite divided in 4 groups (Silorane system restored with or without enamel cavosurface acid-etching and Clearfil SEBond/Z350XT with or without enamel cavosurface acid-etching). To induce artificial aging, samples were subjected to thermomechanical cycling through 200,000 and thermal cycling between 5 and 55 °C with 30 second filling and 15-second drainage steps. Microhardness and microtensile bond strength were evaluated in 32 teeth (n=8) each and nanoleakage evaluation was performed in 12 teeth (n=3). Samples restored by Clearfil SEBond/Z350 XT without cavosurface acid-etching showed significantly lower microtensile bond strength results. The resin composite Z350XT presented higher values of Knoop microhardness. It was observed little or no infiltration for Silorane groups and moderate infiltration for Clearfil SE Bond groups. Acid-etching of the cavosurface enamel during restoration procedure with Clearfil Se Bond resulted in a stronger bond after thermomechanical cycling. Silorane groups showed less infiltration than Clearfil SE Bond groups (AU)


Assuntos
Humanos , Adesivos , Resinas Compostas , Preparo da Cavidade Dentária , Resinas de Silorano , Resistência à Tração
10.
Microsc Res Tech ; 80(8): 943-949, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28488772

RESUMO

AIM: Evaluate the composite-to-enamel bond after passive or active application of self-etching primer systems on polished or pre-etched enamel with phosphoric acid. MATERIALS AND METHODS: Two self-etch adhesives systems (SEAS) were used: Clearfil SE Bond and Easy Bond. Third human molars were divided into 8 groups (N = 10). The crown of each tooth was sectioned into halves and the mesial/distal surfaces were used. The adhesives were actively or passively applied on enamel with or without prior phosphoric-acid etching. Resin composite cylinders were built after adhesive application. After stored in relative humidity for 24 hr/37°C the specimens were subjected to microshear test in universal testing a machine at a crosshead speed of 0.5 mm/minute. The results were analyzed with three-way ANOVA and the Tukey test. The enamel-etching pattern was evaluated under SEM. RESULTS: The 2-step SEAS system presented significantly higher adhesive bond strength means (47.37 MPa) than the 1-step (36.87 MPa). A poor enamel- etching pattern was observed in active mode showing irregular and short resin tags, however there was not compromised the bond strength. CONCLUSION: Active or passive application produced similar values of bond strength to enamel regardless of enamel pretreatment and type of SEAS.

11.
Arq. odontol ; 53: 1-7, jan.-dez. 2017. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-906067

RESUMO

Objetivo: o objetivo deste estudo foi verificar a correlação entre a avaliação da ansiedade realizada por meio de medidas fisiológicas e pela observação do comportamento de pacientes com paralisia cerebral realizado pelo dentista durante a primeira consulta odontológica. Métodos: quarenta pacientes com idade variando de 7 a 26 anos, com paralisia cerebral foram submetidos a exames odontológicos. A pressão arterial e a frequência cardíaca foram aferidas no início e no final da primeira consulta odontológica. O dentista avaliou o comportamento antes e após o exame clínico dentário através da observação do comportamento do paciente (inquietação / agitação / tiques nervosos, palidez, transpiração excessiva, resistência e mudança aparente na frequência respiratória). Foi utilizado o teste de correlação de Spearman para determinar a correlação entre as medidas fisiológicas e a classificação comportamental da ansiedade feita pelo cirurgião dentista a um nível de significância de 95%. Resultados: os sinais comportamentais mais frequentes foram inquietação / agitação / tiques nervosos (50,0%) e resistência (27,5%). Foi encontrada uma correlação positiva significativa entre os dois métodos de avaliação de ansiedade utilizados (p <0,05). Os pacientes considerados ansiosos pelo dentista apresentaram medidas fisiológicas mais elevadas do que aqueles considerados calmos (p <0,05). Conclusão: a observação contínua do comportamento de pacientes com paralisia cerebral durante o exame odontológico é uma ferramenta valiosa para o reconhecimento e avaliação da ansiedade por parte da equipe odontológica. Estudos adicionais são necessários para validar um código de expressões faciais e corporais ou reações de ansiedade em pacientes com paralisia cerebral.(AU)


Aim: The present study aimed to verify the correlation between the evaluation of anxiety performed through physiological measures and the observation of the behavior of patients with cerebral palsy performed by the dentist during the first dental visit. Methods: Forty patients with cerebral palsy, varying from seven to 26 years of age, were submitted to dental examinations. The blood pressure and heart rate were measured at the beginning and end of the first dental appointment. The dentist evaluated the behavior before and after the dental exam by observing the patient's behavior (restlessness / agitation / nervous tics, pallor, excessive perspiration, resistance, and apparent change in breathing rate). The Spearman correlation test was used to determine the correlation between the physiological measures and the behavioral classification of anxiety made by the dentist at a significance level of 95%. Results: The most frequent behavioral signs were restlessness / agitation / nervous tics (50.0%), and resistance (27.5%). Through the Kruskal-Wallis test and Spearman's correlation, a significant positive correlation was found between the two anxiety assessment methods used in this study (p<0.05). The patients considered anxious by the dentist presented higher physiological measurements than did those considered calm (p<0.05). Conclusion: It can therefore be concluded that the continuous observation of the behavior of patients with cerebral palsy during the dental examination is a valuable tool for the recognition and evaluation of anxiety on the part of the dental team. Further studies are warranted to validate a code of facial and body expressions or anxiety reactions in patients with cerebral palsy.(AU)


Assuntos
Humanos , Masculino , Feminino , Técnicas de Observação do Comportamento , Paralisia Cerebral , Ansiedade ao Tratamento Odontológico , Pessoas com Deficiência , Monitorização Fisiológica , Pressão Arterial , Diagnóstico Bucal , Frequência Cardíaca , Sinais e Sintomas
12.
Prosthes. Lab. Sci. ; 3(10): 107-113, jan.-mar. 2014. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-853807

RESUMO

Alterações de forma e posição podem levar a formação de diastemas e afetar a estética do sorriso. Atualmente, em função da expectativa do tempo de tratamento, pequenas alterações de posicionamento facilmente corrigidas imediatamente pela técnica restauradora sem auxílio ortodôntico é uma opção favorável de tratamento nestes casos. O objetivo desse trabalho é apresentar, em um caso clínico, um método de utilização de resinas na recuperação estética através do contorno cosmético para correção do sorriso sem a intervenção da técnica ortodôntica


Assuntos
Humanos , Masculino , Adulto Jovem , Diastema , Diastema/terapia , Estética Dentária/psicologia , Satisfação do Paciente , Resinas Compostas/uso terapêutico , Sorriso , Resultado do Tratamento
13.
J Prosthodont ; 22(1): 54-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22938145

RESUMO

PURPOSE: The aim of this study was to evaluate the Knoop microhardness and microshear bond strength (MSBS) of dual-cured luting systems and flowable resin bonded to leucite-reinforced ceramics and enamel. MATERIALS AND METHODS: Eighty bovine incisors were randomly divided into four groups per test (microhardness and microshear; n = 10) according to the bonding procedure: Excite DSC/Variolink, Clearfil SE Bond/Panavia F, Adper Scotchbond Multi-Purpose Plus/RelyX ARC, and Adper Single Bond 2/Filtek Z350 Flow. For the KHN measurement, the cement was applied on the enamel surface and light-cured through a ceramic disk (5 mm diameter × 1.2 mm thick). Five indentations were performed in each specimen and measured at HMV-2. For the microshear test, two cylinders of a leucite-reinforced ceramic (1 mm diameter × 2 mm height) were bonded to the enamel substrate in accordance with the bonding procedures previously established. One cylinder was tested 24 hours after cementation, and the other was subjected to thermocycling (2000 cycles) and then submitted to an MSBS test. The data from the hardness and bond strength tests were subjected to one- and two-way repeated-measures analysis of variance (ANOVA), respectively, and to Tukey's test (α= 0.05). RESULTS: Scotchbond/RelyX ARC presented higher values of bond strength, while Single Bond/Z350 Flow showed lower values. The thermocycling promoted a reduction in the bond strength values for all groups. Panavia F presented higher values of KHN, and the flowable resin presented the lowest. RelyX ARC and Variolink presented intermediate values on hardness evaluation. CONCLUSIONS: For ceramic cementation, dual-cured resin luting systems promoted more reliable bonding and microhardness values than the flowable resin.


Assuntos
Colagem Dentária/métodos , Porcelana Dentária , Análise do Estresse Dentário , Cimentos de Resina , Autocura de Resinas Dentárias , Silicatos de Alumínio , Animais , Bovinos , Cimentação/métodos , Esmalte Dentário , Porcelana Dentária/química , Dureza , Teste de Materiais , Distribuição Aleatória , Cimentos de Resina/química , Reologia , Resistência ao Cisalhamento
14.
Rev. bras. odontol ; 69(2): 250-254, Jul.-Dez. 2012. graf, tab
Artigo em Português | LILACS | ID: lil-720352

RESUMO

A instrumentação dos canais radiculares através do uso de lima única em movimento recíproco vem se popularizando devido à redução do tempo de trabalho e menor tendência de fraturas dos instrumentos. Antes de escolher o sistema que vai utilizar, o cirurgião- -dentista deve conhecer as capacidades e limitações de cada sistema baseado em evidências científicas. Esse artigo realizou uma revisão de literatura sobre o movimento recíproco para instrumentação do sistema de canais radiculares apontando as vantagens e desvantagens da utilização dessa cinemática de instrumentação.


The canal’s instrumentation by using single file in reciprocation movement is gaining popularity due to the reduction of working time and less prone to fractures of the instruments. Before choosing which system will use, the dentist must know the capabilities and limitations of each system based on scientific evidence. This article reviews the literature on the reciprocation movement pointing out the advantages and disadvantages of this different kinematic instrumentation.


Assuntos
Raiz Dentária/lesões , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Endodontia
15.
Microsc Res Tech ; 75(5): 671-6, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22173779

RESUMO

PURPOSE: The aim of this study was to evaluate the nanoleakage patterns between dental enamel and reinforced leucite ceramic, bonded with resin luting systems and a flowable composite resin. MATERIALS AND METHODS: Twelve crowns of bovine incisors were randomly divided into four groups (n = 3) according to the luting procedure: Excite/Variolink II, Clearfil SE Bond/Panavia F, Scotchbond Multi-PURPOSE Plus/RelyX ARC, and Single Bond 2/Filtek Z350 Flow. To evaluate the nanoleakage patterns, IPS Empress Esthetic disks (5 mm Ø and 1.2-mm thick) were bonded to enamel, and, after 24 h, the specimens were immersed in a 50% (w/v) solution of silver nitrate (24 h), fixed, dehydrated, and processed scanning electron microscopy (SEM). RESULTS: None nanoleakage on interface of the groups that Single Bond 2 followed by the flowable composite were used. The highest percentage of nanoleakage was shown by the Excite/Variolink II protocol. Also, in all conditions tested, none silver nitrate uptake was observed between the leucite-reinforced ceramic and the resin luting cement. CONCLUSIONS: The use of a two-step etch-and-rinse adhesive with flowable composite was able to promote an adequate seal of the bond interface at the enamel. Moreover, the conventional dual-cured resin cements associated with simplified and dual-cured adhesives tested are also indicated to bond thin ceramics to enamel, since all presented low silver nitrate uptake.


Assuntos
Silicatos de Alumínio/análise , Cerâmica/análise , Colagem Dentária/métodos , Esmalte Dentário/química , Incisivo/química , Cimentos de Resina/análise , Animais , Bovinos
16.
Lasers Med Sci ; 27(6): 1175-82, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22120471

RESUMO

The aim of this study was to evaluate the influence of the LED curing unit and selective enamel etching on dentin microtensile bond strength (µTBS) for self-etch adhesives in class I composite restorations. On 96 human molars, box-shaped class I cavities were made maintaining enamel margins. Self-etch adhesives (Clearfil SE - CSE and Clearfil S(3) - S3) were used to bond a microhybrid composite. Before adhesive application, half of the teeth were enamel acid-etched and the other half was not. Adhesives and composites were cured with the following light curing units (LCUs): one polywave (UltraLume 5 - UL) and two single-peak (FlashLite 1401 - FL and Radii Cal - RD) LEDs. The specimens were then submitted to thermomechanical aging and longitudinally sectioned to obtain bonded sticks (0.9 mm(2)) to be tested in tension at 0.5 mm/min. The failure mode was then recorded. The µTBS data were submitted to a three-way ANOVA and Tukey's (α = 0.05). For S3, the selective enamel-etching provided lower µTBS values (20.7 ± 2.7) compared to the non-etched specimens (26.7 ± 2.2). UL yielded higher µTBS values (24.1 ± 3.2) in comparison to the photoactivation approach with FL (18.8 ±3.9) and RD (19.9 ±1.8) for CSE. The two-step CSE was not influenced by the enamel etching (p ≥ 0.05). Enamel acid etching in class I composite restorations affects the dentin µTBS of the one-step self-etch adhesive Clearfil S(3), with no alterations for Clearfil SE bond strength. The polywave LED promoted better bond strength for the two-step adhesive compared to the single-peak ones.


Assuntos
Condicionamento Ácido do Dente/métodos , Lâmpadas de Polimerização Dentária , Dentina , Cura Luminosa de Adesivos Dentários/métodos , Restauração Dentária Permanente/classificação , Restauração Dentária Permanente/métodos , Adesivos Dentinários , Humanos , Metacrilatos , Dente Molar , Cimentos de Resina , Resistência à Tração
17.
Braz. j. oral sci ; 9(4): 455-458, Oct.-Dec. 2010. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-582277

RESUMO

Aim: To evaluate the selective acid etching of enamel and dentin on microtensile bond strength (¦ÌTBS) of a self-adhesive resin cement. Methods: Forty-eight bovine teeth were selected and had the buccal surface ground to obtain a flat dentin (n=24) or enamel (n=24) surface. Z250 composite resin blocks (4 x 3 x 8 mm) were prepared for cementation at enamel and dentin. Each substrate received three experimental resin cementation strategies: 1) 37% phosphoric acid etching before the application of RelyX Unicem; 2) application of RelyX Unicem alone; 3) RelyX ARC as a control. Samples were light-cured using a halogen light (Optilux 501, 700mW/cm2), for 40 s. Hourglass-shaped specimens were obtained and submitted to a tensile strength at a crosshead speed of 0.5 mm/min in a universal testing machine. For statistical analysis, data were submitted to ANOVA and Tukey¡¯s test at a pre-set alpha (¨¢=0.05). Results: RelyX Unicem showed similar bond strength value (16.5 MPa) when compared to the pretreatment with acid etching (11.9 Mpa) and to the conventional resin cement (18.1 MPa) for enamel. All luting strategies presented similar dentin bond strength, but significantly lower than enamel bond strength. Conclusions: Acid etching prior to RelyX Unicem application did not improve microtensile bond strength for enamel and dentin.


Assuntos
Animais , Bovinos , Condicionamento Ácido do Dente , Resinas Compostas , Análise do Estresse Dentário , Dentina , Esmalte Dentário , Cimentos de Resina , Resistência à Tração , Teste de Materiais , Propriedades de Superfície
18.
Clín. int. j. braz. dent ; 6(3): 336-340, jul.-set. 2010. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-757811

RESUMO

O contorno cosmético é uma técnica operatória que requer do profissional amplo conhecimento de estética e reflexão da luz, pois implica desgaste irreversível da estrutura dental sadia. Este artigo relata um caso clínico de contorno cosmético que ilustra as possibilidades de remodelação estética do sorriso guiadas por princípios de ilusão de óptica, na qual foi possível, mediante a realização de desgastes em esmalte, obter resultados satisfatórios com previsibilidade.


Cosmetic recontouring is a technique that demands comprehensive skills and knowledge about esthetics light dynamics by the professional, since irreversible reduction of tooth sound structure is required. This paper is a case report of the cosmetic contouring showing the possibilities of esthetic recontouring of the smile following principles of optical illusion, from which it was possible through enamel reduction to achieve satisfactory, predictable results.


Assuntos
Humanos , Feminino , Estética Dentária , Satisfação do Paciente , Desgaste dos Dentes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA