Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Oral Implants Res ; 33(3): 291-301, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34951501

RESUMO

OBJECTIVE: This prospective study aimed to assess the effectiveness of using a single short implant to retain a single-implant mandibular overdenture (SIMO) in participants with severely atrophic edentulous mandibles. MATERIAL AND METHODS: The study sample included 18 edentulous participants with severely resorbed mandibular ridges and limited bone height in the symphyseal region sufficient for the insertion of a 7.0-mm-height implant. First, patients received new conventional dentures or had their dentures relined, followed by the insertion of a 3.75 x 7 mm morse-taper implant, and the incorporation of a stud-type attachment and a nylon retentive insert after a 3-month healing period. Implant stability quotient (ISQ) was measured at baseline and after 3 and 12 months. Patient-reported outcomes (satisfaction with the dentures and oral health-related quality of life) were assessed before implant placement and at the 3-, 6-, and 12-month follow-ups. Clinical-radiographic outcomes and the incidence of prosthodontic events were assessed throughout the follow-up period. RESULTS: The implant survival rate was 100%. ISQ increased from baseline (72.7 ± 6.6) to the 3-month (82.0 ± 3.3) and 1-year (85.4 ± 2.9) follow-ups (p < .001). After 1 year, satisfaction with the mandibular prosthesis increased significantly, and the overall OHIP-Edent score decreased by 79.2%. No effects were found for the maxillary denture (p = .420). Due to dissatisfaction with treatment, two participants (11.1%) required additional implants after the 1-year follow-up and were considered as prosthodontic failures. CONCLUSION: Single-implant mandibular overdenture retained by a short implant showed favorable outcomes after 1 year. Further studies with larger samples and longer follow-up periods are needed to confirm the findings of this single-group prospective study. The present study was registered at the Brazilian Clinical Trials Registry (REBEC), identifier RBR-7p2xmg. The trial registry occurred during the study execution, and its final approval was delayed because of several formatting adequacies required by the platform REBEC.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Prótese Dentária Fixada por Implante , Retenção de Dentadura , Humanos , Mandíbula/cirurgia , Satisfação do Paciente , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA