Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros











Intervalo de año de publicación
1.
J. Vasc. Bras. (Online) ; J. vasc. bras;20: e20190117, 2021. tab, graf
Artículo en Portugués | LILACS | ID: biblio-1279397

RESUMEN

Resumo Contexto A veia safena magna é usada como material de remendo em vários tipos de reconstrução arterial, incluindo no trauma e endarterectomias de carótida e femoral. Houve relatos de ruptura do remendo de safena, particularmente de veias colhidas na região do tornozelo. Há uma necessidade de medição objetiva da resistência tecidual da safena magna. Objetivos Mensurar a força tensional suportada pela veia safena magna e analisar a correlação entre resistência e diâmetro da veia. Métodos As veias foram coletadas durante operações de safenectomia por varizes dos membros inferiores. Foram analisados apenas segmentos sem refluxo. Foram analisados 10 membros de oito pacientes, com um total de 20 espécimes. Os espécimes foram submetidos a ensaio de tração em equipamento eletrônico, obtendo-se os valores de tensão máxima do material em quilogramas-força por centímetro quadrado (kgf/cm2; força máxima dividida pela área de secção transversa do segmento submetido à tração). Resultados A tensão máxima suportada pela veia safena do tornozelo variou de 74,02 a 190,10 kgf/cm2, e a tensão máxima da veia safena da crossa variou de 13,53 a 69,45 kgf/cm2 (p < 0,0001). O coeficiente de correlação de Pearson entre o diâmetro da veia distendida e a tensão máxima suportada foram iguais a -0,852 (correlação inversa moderada a forte). Conclusões A resistência tecidual da veia safena magna do tornozelo é maior do que a da crossa em mulheres submetidas a operação de varizes; há correlação negativa entre o diâmetro da veia e sua resistência tecidual nessa mesma população.


Abstract Background The great saphenous vein is used as patch material in several types of arterial reconstruction, including trauma and carotid and femoral endarterectomy. There have been reports of saphenous patch blowout, particularly of patches constructed with veins harvested from the ankle. There is a need for objective measurement of the resistance of saphenous vein tissues. Objectives To measure the tensile strength of the great saphenous vein harvested at the ankle and groin and analyze the correlation between diameter and tissue strength. Methods Venous samples were harvested during elective saphenous stripping in patients with symptomatic varicose veins. Only segments without reflux were included. Ten limbs from eight patients were studied, providing 20 samples in total. Venous segments were opened along their longitudinal axis and fitted to electronic traction assay equipment to obtain values for material maximum tension in kilograms-force per square centimeter (kgf/cm2; the maximum force resisted by the segment, divided by its cross-sectional area). Results The average maximum tension in the ankle saphenous vein group ranged from 74.02 to 190.10 kgf/cm2 and from 13.53 to 69.45 kgf/cm2 in the groin saphenous vein group (p < 0.0001). The Pearson coefficient for the correlation between vein diameter and maximum tension was -0.852 (moderate to strong inverse correlation). Conclusions Ankle saphenous vein tissue from female patients operated for varicose veins has significantly higher resistance than saphenous vein tissue from the groin and there is an inverse relation between vein diameter and resistance of tissue from the same population.


Asunto(s)
Humanos , Femenino , Adulto , Persona de Mediana Edad , Vena Safena/anatomía & histología , Resistencia a la Tracción , Vena Safena/lesiones , Várices , Lesiones del Sistema Vascular , Conducto Inguinal/anatomía & histología , Tobillo/anatomía & histología
2.
Acta cir. bras ; Acta cir. bras;26(5): 329-332, Sept.-Oct. 2011. ilus, tab
Artículo en Inglés | LILACS, Sec. Est. Saúde SP | ID: lil-599632

RESUMEN

PURPOSE: To investigate the effects of a new electrocautery device to provoke endovascular venous thermal injury. METHODS: An experimental endovascular electrocautery was placed inside eight ex-vivo bovine saphenous veins models. Each one was divided in eight segments and progressive intensities of electric energy liberated. The macroscopic and microscopic effects were analyzed. RESULTS: Forty bovine saphenous veins segments were studied. The higher the electric energy applied the greater the nuclear picnosis and more intense the cytoplasmatic shrinkage and electrocoagulation effects. CONCLUSION: The experimental endovascular electrocautery device demonstrated to be both capable of inducing the destruction of the intimal layers of the studied vein model and provoke endovascular thermal injury.


OBJETIVO: Investigar os efeitos de um modelo experimental de eletrocautério em provocar lesão venosa térmica endovascular. MÉTODOS: O eletrocautério endovascular foi colocado dentro de oito modelos experimentais de veia safena bovina. Cada uma foi dividida em oito segmentos e intensidades progressivas de energia elétrica liberada. Os efeitos macroscópicos e microscópicos foram analisados. RESULTADOS: Foram estudados quarenta segmentos de veia safena bovina. Quanto maior a energia elétrica aplicada pelo eletrocauterizador endovascular maiores foram as alteraçoes de picnose nuclear e mais intensa a retração citoplasmática observada. CONCLUSÃO: O eletrocautério endovascular experimental demonstrou ser capaz de induzir a destruição da camada íntima e provocar lesão térmica endovascular.


Asunto(s)
Animales , Bovinos , Quemaduras por Electricidad/etiología , Electrocoagulación/efectos adversos , Vena Safena/lesiones , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Modelos Teóricos , Vena Safena/cirugía , Conductividad Térmica , Factores de Tiempo
3.
Acta Cir Bras ; 26(5): 329-32, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21952653

RESUMEN

PURPOSE: To investigate the effects of a new electrocautery device to provoke endovascular venous thermal injury. METHODS: An experimental endovascular electrocautery was placed inside eight ex-vivo bovine saphenous veins models. Each one was divided in eight segments and progressive intensities of electric energy liberated. The macroscopic and microscopic effects were analyzed. RESULTS: Forty bovine saphenous veins segments were studied. The higher the electric energy applied the greater the nuclear picnosis and more intense the cytoplasmatic shrinkage and electrocoagulation effects. CONCLUSION: The experimental endovascular electrocautery device demonstrated to be both capable of inducing the destruction of the intimal layers of the studied vein model and provoke endovascular thermal injury.


Asunto(s)
Quemaduras por Electricidad/etiología , Electrocoagulación/efectos adversos , Vena Safena/lesiones , Animales , Bovinos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Modelos Teóricos , Vena Safena/cirugía , Conductividad Térmica , Factores de Tiempo
4.
Rev. bras. cardiol. invasiva ; 19(2): 122-130, jul. 2011. tab, graf
Artículo en Portugués | LILACS, Sec. Est. Saúde SP | ID: lil-595224

RESUMEN

Introdução: Embora os stents farmacológicos tenham reduzido acentuadamente a reestenose e a necessidade de novas revascularizações na maioria dos cenários clínicos e angiográficos, o benefício desses dispositivos no tratamento de lesões em enxertos de veia safena (EVS) ainda precisa ser definido. O objetivo deste estudo foi comparar a incidência de eventos cardíacos adversos maiores (ECAM) entre stents farmacológicos e stents não-farmacológicos em lesões em EVS em pacientes não-selecionados. Métodos: Foram incluídos pacientes tratados em dois hospitais terciáriosentre maio de 2006 e janeiro de 2009. O objetivo primário foi comparar a incidência de ECAM entre stents farmacológicos e stents não-farmacológicos durante a hospitalizaçãoe no seguimento a longo prazo. Resultados: No total, foram incluídos, consecutivamente, 308 pacientes, divididos de acordo com o tipo de stent implantado (209 com stents farmacológicos e 99 com stents não-farmacológicos). A média de idade do grupo foi de 68 anos e a dos EVS, de 10,9 anos. Na fase intra-hospitalar, houve tendência para maior incidência de ECAM no grupo que recebeu stents farmacológicos (12% vs. 5,1%; P = 0,06). Até 24 meses, a incidência de ECAM foi equivalente nos dois grupos (17,2% nogrupo stents farmacológicos vs. 18,2% no grupo stents não-farmacológicos; P = 0,87). Trombose do stent definitiva/provável foi semelhante em ambos os grupos (2,3% no grupo stents farmacológicos vs. 2% no grupo stentsnão-farmacológicos; P = 0,94). Conclusões: Nesta série de pacientes complexos do mundo real, não houve preocupação com a segurança a longo prazo relacionada ao uso de stents farmacológicos no tratamento de lesões em EVS, com incidências similares de morte cardíaca/infarto do miocárdio/trombose do stent em ambos os grupos.


Background: Although drug-eluting stents have markedly reduced restenosis and the need for repeat lesion revascularization in the vast majority of clinical and angiographic scenarios, the benefit of these devices for the treatment of saphenous-vein graft (SVG) lesions is yet to be defined. The aim of our study was to compare the rate of major adverse clinical events (MACE) between drug-eluting stentsand bare-metal stents in SVG lesions in non-selected patients. Methods: Patients treated in two tertiary hospitals betweenMay 2006 and January 2009 were included. The primary objective was to compare the incidence of MACE betweendrug-eluting stents and bare-metal stents during hospitalization and in the long-term follow-up. Results: Overall, 308 patients were consecutively enrolled and divided according to the type of stent deployed (209 with drug-eluting stents and 99 with bare-metal stents). Mean age was 68 years and SVG mean age was 10.9 years. In the in-hospital phase there was a trend towards higher MACE in the drug-eluting stents group (12% vs. 5.1%; P = 0.06). The incidence of MACE in up to 24 months was equivalent between groups (17.2%for the drug-eluting stents group vs. 18.2% for the baremetal stents group; P = 0.87). Definite/probable stent thrombosis was similar in both groups (2.3% for the drug-eluting stents group vs. 2% for bare-metal stents group; P = 0.94). Conclusions: In this real world series of complex patients there was no long-term safety concerns related to the use of drug-eluting stents in the treatment of SVG lesions, with similar rates of cardiac death/myocardial infarction/stent thrombosis in both groups.


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Stents Liberadores de Fármacos , Stents , Vena Safena/cirugía , Vena Safena/lesiones , Revascularización Miocárdica/métodos , Revascularización Miocárdica , Trombosis/complicaciones
5.
Arq Neuropsiquiatr ; 67(3B): 897-9, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19838525

RESUMEN

OBJECTIVE: To show a rare lesion that sometimes simulates vascular disorder of the lower extremities. METHOD: Three patients were operated and the follow-up period was eight months, the surgical technique was neurotomy of the infrapatellar and descendent branches. RESULTS: In two cases there were almost total pain resolution, and in other case improvement only. CONCLUSION: Surgical treatment yields good results in this type of internal saphenous nerve lesion, and could be useful as an alternative to conservative treatment.


Asunto(s)
Artroscopía/efectos adversos , Pierna/inervación , Traumatismos de los Nervios Periféricos , Femenino , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/cirugía , Pierna/cirugía , Masculino , Persona de Mediana Edad , Nervios Periféricos/cirugía , Estudios Retrospectivos , Vena Safena/lesiones , Vena Safena/cirugía
6.
Arq. neuropsiquiatr ; Arq. neuropsiquiatr;67(3b): 897-899, Sept. 2009. ilus
Artículo en Inglés | LILACS | ID: lil-528684

RESUMEN

OBJECTIVE: To show a rare lesion that sometimes simulates vascular disorder of the lower extremities. METHOD: Three patients were operated and the follow-up period was eight months, the surgical technique was neurotomy of the infrapatellar and descendent branches. RESULTS: In two cases there were almost total pain resolution, and in other case improvement only. CONCLUSION: Surgical treatment yields good results in this type of internal saphenous nerve lesion, and could be useful as an alternative to conservative treatment.


OBJETIVO: Apresentar lesões raras do nervo safeno interno interno, que muitas vezes, simulam doenças vasculares dos membros inferiores. MÉTODO: Três pacientes foram operados e acompanhados por um período de oito meses. A técnica cirúrgica consistiu na neurotomia dos ramos infrapatelar e descendente do nervo safeno interno. RESULTADOS: Nos dois primeiros casos houve quase desaparecimento total da dor em pouco tempo e no terceiro apenas melhora. CONCLUSÃO: O tratamento cirúrgico dá bons resultados neste tipo de lesão do nervo safeno interno e poderia ser útil como alternativa ao tratamento conservador.


Asunto(s)
Femenino , Humanos , Masculino , Persona de Mediana Edad , Artroscopía/efectos adversos , Pierna/inervación , Nervios Periféricos/lesiones , Estudios de Seguimiento , Articulación de la Rodilla/cirugía , Pierna/cirugía , Nervios Periféricos/cirugía , Estudios Retrospectivos , Vena Safena/lesiones , Vena Safena/cirugía
7.
Rev. bras. cardiol. invasiva ; 16(3): 328-332, jul.-set. 2008. ilus, tab
Artículo en Portugués | LILACS, Sec. Est. Saúde SP | ID: lil-503481

RESUMEN

Fundamentos: Distúrbios de fluxo coronário decorrentes de embolização de fragmentos de ateroma/trombo estão associados a pior prognóstico após intervenção coronária percutânea (ICP). A abordagem de lesões em pontes de safena (PS) e no cenário de síndromes coronárias agudas (SCA) está frequentemente associadda a essas complicações. Apesar de dispositivos de proteção embólica terem demonstrado seu valor na prevenção desses eventos, estes adicionam tempo e custo à ICP, além de terem seu uso limitado às PS. Recém-desenvolvido, o stent MGuard combina uma malha microscóspica presa às hastes de um stent não-farmacológico, conferindo baixo perfil a esse dispositivo. Objetivos: Avaliar a eficácia e a segurança do stent MGuard por meio de desfechos clínicos e angiográficos. Método: Estudo unicêntrico com 19 pacientes portadores de lesões de novo em PS ou lesões com características angiográficas de instabilidade em coronárias nativas. O desfecho primário inclui a taxa de eventos cardíacos adversos maiores (ECAM) em trinta dias. Resultados: A apresentação clínica em 60 por cento dos casos era de SCA e em 55 por cento dos pacientes a lesão encontrava-se em PS. O stent MGuard foi implantado com sucesso em todos os casos, alcançando fluxo TIMI 3/blush 3 ao final de todas as ICPs, não sendo observadas complicações angiográficas. Não registradas elevações de CK-MB maiores de três vezes o valor de rferência pós-ICP ou ECAM...


Background: Disturbances in coronary flow due to embolization of thrombus/atheroma fragments are associated with poor prognosis after percutaneous coronary intervention (PCI). Lesions in saphenous vein grafts (SVG) and acute coronary syndromes (ACS) are typically associated with these complications. Although embolic protection devices have shown to reduce the incidence of such complications, they add time and costs to the procedure, and their use is limited to SVG. The newly developed MGuard™ stent combines a microscopic net connected to the struts of a bare metal stent, characterizing this new low-profile device. Objective: To evaluate safety and efficacy of the novel MGuard™ stent system through clinical and angiographic outcomes. Methods: Single-center study including 19 patients with de novo lesions in SVG or with unstable lesions in native vessels as evidenced by angiography. Primary end point included 30-day incidence of major adverse cardiac events (MACE). Results: ACS was the clinical presentation in 60% of cases, and in 55% of the patients the lesion was in a SVG. The MGuard™ stent was successfully delivered in all cases, reaching TIMI 3/blush 3 flow at the end of all procedures. There were no cases of angiographic complications, CK-MB elevations > 3x the reference values after PCI, or MACE at 30 day-follow-up. Conclusion: In this preliminary evaluation, the MGuard™ stent showed high efficacy in a group of patients with highly complex angiographic profile (without the use of adjunctive embolic protection devices). Six-month angiographic follow-up and a larger cohort of patients are necessary to corroborate these results.


Asunto(s)
Humanos , Femenino , Adulto , Anciano , Stents , Puente de Arteria Coronaria/métodos , Seguridad de Equipos , Aspirina/administración & dosificación , Embolia , Estudios Prospectivos , Estudios de Factibilidad , Heridas y Lesiones/terapia , Vena Safena/lesiones
9.
Rev Bras Cardiol Invas ; 10(2): 9-14, abr.mai.jun 2002. ilus
Artículo en Portugués | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1066246

RESUMEN

A terapia percutânea com implante de stents em lesões de enxerto de veia safena tem se apresentado como interessante alternativa a uma nova cirurgia de revascularização do miocárdio, tanto por sua menor morbimortalidade como também por índices des sucesso bem aceitáveis. Entretanto, diversos estudos em artérias coronárias nativas demonstraram que os índices de reestenose estão diretamente relacionados com a extensão do segmento tratado, isto é com a extensão do stent utlizado. Em relação aos enxertos de veia safena esta relação ainda necessita investigação adicional. No Instituto "Dante Pazzanese" de Cardiologia de 1994 a 2001, 352 pacientes revascularizados foram submetidos a implante de stents, sendo subdivididos em dois grupos, de acordo com a extensão dos stents...


Asunto(s)
Revascularización Miocárdica , Stents/tendencias , Vena Safena/lesiones , Vena Safena/trasplante , Tolerancia al Trasplante
10.
In. Sousa, Amanda GMR; Staico, Rodolfo; Sousa, J Eduardo MR. Stent Coronário. São Paulo, Atheneu, 2001. p.119-151, ilus.
Monografía en Portugués | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1069529
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA