Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.230
Filtrar
1.
G Ital Cardiol (Rome) ; 25(9): 690-692, 2024 Sep.
Artículo en Italiano | MEDLINE | ID: mdl-39239821

RESUMEN

Although mitral annular calcification is a common degenerative condition of the fibrous mitral annulus, tricuspid annular calcification, especially isolated, is rare. We report the case of a 73-year-old male, with a history of hypertension and severe kyphoscoliosis, referred to the emergency department for progressive dyspnea and leg swelling. Echocardiography revealed a dilated right heart with a homogeneous, hyperechoic, crescent shaped mass along the tricuspid annulus. Computed tomography confirmed the calcific nature of the lesion. Right heart catheterization revealed mild pre-capillary pulmonary hypertension and a mild spirometrically-defined restrictive ventilatory defect. Kyphoscoliosis has recently been associated with alterations in cardiac deformation and with an increased risk of restrictive lung disease. In our patient, we hypothesized that both these anomalies could have led to premature tricuspid annular degeneration resulting in a giant tricuspid calcification.


Asunto(s)
Calcinosis , Cifosis , Escoliosis , Válvula Tricúspide , Humanos , Masculino , Anciano , Calcinosis/complicaciones , Calcinosis/diagnóstico por imagen , Válvula Tricúspide/diagnóstico por imagen , Cifosis/complicaciones , Escoliosis/complicaciones , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Ecocardiografía
2.
Turk Kardiyol Dern Ars ; 52(6): 375-383, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39225646

RESUMEN

OBJECTIVE: This study aims to assess the efficacy and safety of tricuspid valve (TV) transcatheter edge-to-edge repair (TEER) procedures using the MitraClip or TriClip device in high-risk patients with severe secondary tricuspid regurgitation (TR) and provide Turkish-specific data on procedural outcomes and clinical follow-up. METHODS: This study enrolled 42 high-risk patients with severe secondary TR who underwent transcatheter edge-to-edge repair using either the MitraClip or TriClip device. Patient selection criteria included severe TR, high surgical risk (EuroScore ≥ 8 and Tricuspid Regurgitation Impact Severity Score (TRI-SCORE) ≥ 6), symptomatic despite medical therapy, and anatomical suitability for TriClip. Patients underwent rigorous evaluation by a specialized cardiac team before the procedure, including 2D/3D transesophageal echocardiography to assess eligibility. RESULTS: The study achieved a 100% procedural success rate, defined as successful implantation and at least one-degree reduction in TR severity. Post-procedure assessments revealed that 88.1% of patients had mild to moderate TR, indicating significant improvement, while only 11.9% retained severe TR. During the median follow-up of 11.5 months, rehospitalization occurred in 23.8% of patients, and mortality was observed in 7.1% of patients, demonstrating a favorable safety profile. Comparative analysis between TriClip and MitraClip devices showed similar efficacy and safety outcomes, with no significant differences in procedural durations or complication rates. CONCLUSION: The study demonstrates the effectiveness and safety of TV TEER using TriClip or MitraClip devices in managing severe secondary TR in high-risk patients. Procedure success, improved TR severity, and favorable clinical outcomes were observed, supporting the role of transcatheter techniques in TR management.


Asunto(s)
Cateterismo Cardíaco , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Masculino , Femenino , Anciano , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Turquía , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Ecocardiografía Transesofágica , Persona de Mediana Edad , Anciano de 80 o más Años , Índice de Severidad de la Enfermedad , Implantación de Prótesis de Válvulas Cardíacas/métodos
3.
BMC Anesthesiol ; 24(1): 328, 2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39271989

RESUMEN

BACKGROUND: To date, the relationship between the Transesophageal Echocardiography (TEE) monitoring indicator tricuspid annular plane systolic excursion (TAPSE) and the incidence of postoperative acute kidney injury (AKI) in Coronary Artery Bypass Grafting(CABG) patients remains unknown. The main objective of this study was to explore the relationship between the TAPSE and the incidence of AKI in CABG patients. METHODS: This was a multicenter prospective cohort study was conducted between September 2021 and July 2022. Among 266 patients aged at least 18 years who underwent elective CABG, 140 were included. RESULTS: We measured TAPSE via M-mode TEE via the mid-esophageal (ME) right ventricle(RV) inflow-outflow view (60°). All echocardiographic measurements were performed three separate times at each time point: T0 (before the start of CABG), T2 (approximately 5 ∼ 10 min after neutralization of protamine) and T3 (before leaving the operating room), and then averaged. Serum creatinine was measured 1 day before and within 7 days after CABG. There was no statistically significant association between the TEE-monitoring indicator TAPSE and the incidence of postoperative AKI in patients who underwent CABG. CONCLUSIONS: The TAPSE was not significantly correlated with postoperative AKI incidence and could not predict the early occurrence of postoperative AKI in CABG patients. TEE needs more evaluation for clinical efficacy of predicting the early occurrence of postoperative AKI in isolated CABG.


Asunto(s)
Lesión Renal Aguda , Puente de Arteria Coronaria , Ecocardiografía Transesofágica , Complicaciones Posoperatorias , Válvula Tricúspide , Humanos , Puente de Arteria Coronaria/efectos adversos , Lesión Renal Aguda/epidemiología , Lesión Renal Aguda/etiología , Estudios Prospectivos , Femenino , Masculino , Incidencia , Ecocardiografía Transesofágica/métodos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Anciano , Persona de Mediana Edad , Válvula Tricúspide/diagnóstico por imagen , Estudios de Cohortes
4.
Ann Noninvasive Electrocardiol ; 29(5): e13133, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39263918

RESUMEN

OBJECTIVE: This study aims to assess the tricuspid annular plane systolic excursion (TAPSE)/PASP ratio as a potential indicator for predicting the probability of developing pulmonary arterial hypertension (PAH) in hyperthyroidism patients. A nomogram model will be developed based on our findings, as well as the receiver operating characteristic (ROC) curve. METHODS: The study involved 166 hyperthyroid patients treated at Yijishan Hospital, and the period covered August 2021 to August 2022. Patients were divided into two groups according to pulmonary artery systolic pressure ≥35 mmHg. Univariate and multivariate logistic analyses were performed on the two groups' demographic and laboratory data to identify potential diagnostic markers. These parameters were evaluated using ROC curves to determine their precision in forecasting PAH. The findings were validated by plotting a calibration curve based on a line chart model. RESULTS: In the study, eventually, 80 patients were enrolled: 30 in the PAH group and 50 in the No PAH group. Multipleistic regression analysis predicted the occurrence risk of developing PAH. When paired with other conventional echocardiographic parameters (such as TAPSE, MPI, and SV) and serological markers (such as FT3 and FT4), the developed model demonstrated outstanding predictive performance with an area under the ROC curve of 0.985, a Youden index of 0.971, a sensitivity of 100%, and a specificity of 97.1%. CONCLUSIONS: The nomogram model constructed by combining the TAPSE/PASP ratio with FT3 and FT4 serum markers, as well as conventional ultrasound parameters SV and MPI in hyperthyroidism patients, demonstrates robust discriminatory ability and consistency.


Asunto(s)
Hipertiroidismo , Humanos , Hipertiroidismo/complicaciones , Hipertiroidismo/fisiopatología , Femenino , Masculino , Persona de Mediana Edad , Ecocardiografía/métodos , Adulto , Nomogramas , Valor Predictivo de las Pruebas , Hipertensión Pulmonar/fisiopatología , Hipertensión Pulmonar/complicaciones , Hipertensión Pulmonar/diagnóstico , Curva ROC , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Hipertensión Arterial Pulmonar/fisiopatología , Hipertensión Arterial Pulmonar/complicaciones , Medición de Riesgo/métodos
8.
Sci Rep ; 14(1): 19946, 2024 08 27.
Artículo en Inglés | MEDLINE | ID: mdl-39198524

RESUMEN

Computed tomography (CT) is used as a valuable tool for device selection for interventional therapy in tricuspid regurgitation (TR). We aimed to evaluate predictors of TR reduction using CT and automated deep learning algorithms. Patients with severe to torrential TR and CTs prior to either percutaneous annuloplasty (PA) or tricuspid transcatheter edge-to-edge repair (T-TEER) were enrolled. CTs were analyzed using automated deep learning algorithms to assess tricuspid valve anatomy, right heart morphology, and function. Outcome parameters comprised post-interventional TR ≤ 1 and all-cause mortality. 84 patients with T-TEER (n = 32) or PA treatment (n = 52) were enrolled. Patients with a post-interventional TR ≤ 1 presented lower tenting heights and smaller tenting angles compared to patients with a TR > 1. Tenting height showed the best accuracy for post-interventional TR > 1 with an AUC of 0.756 (95% CI 0.560-0.951) in the T-TEER and 0.658 (95% CI 0.501-0.815) in the PA group, consistent with a suggested threshold of 6.8 mm and 9.2 mm, respectively. Patients with a post-interventional TR ≤ 1 exhibited a mortality of 4% and those with a TR > 1 of 12% during a follow-up of 331 ± 300 and 370 ± 265 days, respectively (p = 0.124). To conclude, tenting is associated with procedural outcomes and should be considered during screening for interventional TR therapy.


Asunto(s)
Aprendizaje Profundo , Tomografía Computarizada por Rayos X , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Femenino , Masculino , Anciano , Tomografía Computarizada por Rayos X/métodos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Persona de Mediana Edad , Anciano de 80 o más Años , Anuloplastia de la Válvula Cardíaca/métodos , Anuloplastia de la Válvula Cardíaca/efectos adversos , Resultado del Tratamiento
11.
J Am Heart Assoc ; 13(16): e034112, 2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39136306

RESUMEN

BACKGROUND: Right-sided heart failure (HF) due to severe tricuspid regurgitation (TR) is associated with reduced quality of life (QoL). Here, we analyzed the impact of TR on specific QoL dimensions and the effect of transcatheter tricuspid valve intervention (TTVI) on individual QoL items. METHODS AND RESULTS: In this study, we included 174 patients with HF (49% women; median age, 79 years; 97% New York Heart Association ≥3) with baseline QoL assessment undergoing TTVI by transcatheter edge-to-edge-repair at our center between April 2016 and March 2022. QoL was assessed by the standardized Minnesota Living With HF Questionnaire. QoL change after TTVI and correlation to functional end points were analyzed. In addition, all QoL domains and the 21 individual items of the Minnesota Living With HF Questionnaire were analyzed. TTVI significantly reduced TR (TR ≥3: baseline 95%, 1-year-follow-up 7%; P<0.001). Total Minnesota Living with HF Questionnaire score improved from 37 (interquartile range, 26-50) points to 31 (interquartile range, 17-42) points (median follow-up-interval, 355 days; P<0.001). QoL improvement was associated with positive New York Heart Association class, 6-minute walking distance, and actigraphy changes (all P<0.05). The detailed analysis revealed that all items of the physical-related QoL dimension were impaired at baseline and strongly improved after TTVI. In contrast, the emotional and "social" Minnesota Living With HF Questionnaire dimensions were largely unaffected at baseline, yet specific items improved with TTVI. CONCLUSIONS: In this single-center study, we delineate the QoL-associated disease burden of TR and identify specific QoL items that improved after TTVI. Our findings support TTVI in patients with reduced QoL and may add to the development of specific tools assessing the functional status of an increasing patient population undergoing TTVI.


Asunto(s)
Cateterismo Cardíaco , Insuficiencia Cardíaca , Calidad de Vida , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Masculino , Insuficiencia de la Válvula Tricúspide/fisiopatología , Anciano , Insuficiencia Cardíaca/psicología , Insuficiencia Cardíaca/fisiopatología , Cateterismo Cardíaco/métodos , Anciano de 80 o más Años , Resultado del Tratamiento , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Encuestas y Cuestionarios , Costo de Enfermedad , Índice de Severidad de la Enfermedad
12.
Asian Cardiovasc Thorac Ann ; 32(5): 317-320, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39129434

RESUMEN

Severe systemic right ventricular failure with tricuspid regurgitation is associated with poor prognosis. Here, we report a case of 49-year-old patient who experienced severe systemic right ventricular failure following atrial switch. We chose the surgical strategy for this challenging case using comprehensive four-dimensional imaging. The patient underwent tricuspid valve repair and cardiac resynchronization therapy and recovered with improved cardiac function and regulated tricuspid valve regurgitation.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Disfunción Ventricular Derecha , Función Ventricular Derecha , Humanos , Persona de Mediana Edad , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/diagnóstico por imagen , Resultado del Tratamiento , Disfunción Ventricular Derecha/fisiopatología , Disfunción Ventricular Derecha/etiología , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/cirugía , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Recuperación de la Función , Masculino , Índice de Severidad de la Enfermedad , Implantación de Prótesis de Válvulas Cardíacas , Anuloplastia de la Válvula Cardíaca , Procedimientos Quirúrgicos Cardíacos
13.
JACC Cardiovasc Interv ; 17(16): 1936-1945, 2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-39197992

RESUMEN

BACKGROUND: Data on procedural and early outcomes after transjugular transcatheter tricuspid valve replacement (TTVR) are limited. OBJECTIVES: This study sought to evaluate first-in-man procedural and clinical outcomes after transjugular TTVR with a special focus on patients who received large device sizes in whom TTVR outcomes have been questioned. METHODS: The retrospective registry included patients who underwent TTVR using the LuX-Valve Plus system (Jenscare Biotechnology Co Ltd) for symptomatic tricuspid regurgitation (TR) from January 2022 until February 2024 at 15 international centers in a compassionate use setting. The endpoints were procedural TR reduction, in-hospital death, adverse events, and 1-month survival. We further stratified results according to the size of the implanted device (<55 vs ≥55 mm). RESULTS: The registry included a total of 76 patients at a median age of 78 years (Q1-Q3: 72-83 years, 47.4% women). TR was reduced to ≤2+ and ≤1+ in 94.7% and 90.8% of patients (75.0% of patients received TTVR devices ≥55 mm) with well-sustained results at 1-month follow-up (TR ≤2+ in 95.0% and ≤1+ 86.8%). Residual TR was paravalvular in all cases. In-hospital death occurred in 4 patients (5.3%). Four patients (5.3%) underwent cardiac surgery during index hospitalization. Major in-hospital bleeding events occurred in 5 patients (6.6%). New in-hospital pacemaker implantation was required in 3.9% of patients in the overall cohort (5.7% in "pacemaker-naive" individuals). No cases of valve thrombosis, stroke, myocardial infarction, or pulmonary embolism were observed. At 1-month follow-up, survival was 94.4%, and NYHA functional class significantly improved. One further patient received a pacemaker, 1 further bleeding event occurred, and 2 patients underwent reintervention or surgery within the first 30 days after TTVR. No differences in procedural outcomes or adverse events were observed after stratification for valve size. CONCLUSIONS: Transjugular TTVR appears to be a safe and effective treatment option for patients with severe TR with comparable outcomes in very large tricuspid anatomies.


Asunto(s)
Cateterismo Cardíaco , Ensayos de Uso Compasivo , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Femenino , Masculino , Estudios Retrospectivos , Anciano , Resultado del Tratamiento , Factores de Tiempo , Anciano de 80 o más Años , Válvula Tricúspide/cirugía , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Factores de Riesgo , Mortalidad Hospitalaria , Complicaciones Posoperatorias/etiología , Venas Yugulares
15.
JACC Cardiovasc Interv ; 17(16): 1905-1915, 2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-39197989

RESUMEN

BACKGROUND: Tricuspid regurgitation (TR) is associated with worse clinical outcomes after transcatheter aortic valve replacement (TAVR) and mitral transcatheter edge-to-edge repair (M-TEER), but little is known about its association with health status outcomes. OBJECTIVES: The aims of this study were to explore, using the Society of Thoracic Surgeons and American College of Cardiology TVT (Transcatheter Valve Therapy) Registry, the association between baseline TR and health status after TAVR and M-TEER and to determine if baseline TR was associated with clinical endpoints. METHODS: Health status was assessed using Kansas City Cardiomyopathy Questionnaire overall summary (KCCQ-OS) score in patients enrolled in the TVT Registry who underwent isolated TAVR or M-TEER between January 2019 and June 2021. The association among baseline TR and KCCQ-OS score, being alive and well, and clinical outcomes was examined. RESULTS: In total, 130,097 TAVR patients (13.1% with moderate TR, 2.3% with severe TR) and 19,593 M-TEER patients (33.2% with moderate TR, 14.7% with severe TR) were included. Mean KCCQ-OS scores were lower with severe vs moderate vs none to mild TR at baseline prior to TAVR (39.4 ± 24.2 vs 45.2 ± 24.7 vs 51.3 ± 25.3; P < 0.01) or M-TEER (38.1 ± 23.9 vs 41.9 ± 24.7 vs 45.4 ± 25.2; P < 0.01) and similarly at 30 days and 1 year. The odds of being alive and well at 1 year were lower with moderate or severe TR before TAVR (adjusted OR: 0.79 [95% CI: 0.74-0.85] and adjusted OR: 0.81 [95% CI: 0.70-0.94], respectively) and severe TR before M-TEER (adjusted OR: 0.53; 95% CI: 0.40-0.71). Furthermore, moderate or severe TR before TAVR was associated with higher 1-year mortality and readmission, whereas moderate or severe TR before M-TEER was associated with higher 1-year mortality. CONCLUSIONS: In a large cohort of U.S. patients who underwent TAVR or M-TEER, greater baseline TR was associated with worse health status and clinical outcomes. Understanding adverse outcomes of TR in patients with coexisting valvular abnormalities is important, especially with rapidly evolving transcatheter tricuspid valve interventions.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Estado de Salud , Válvula Mitral , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia de la Válvula Tricúspide , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Femenino , Masculino , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/cirugía , Anciano , Factores de Tiempo , Anciano de 80 o más Años , Factores de Riesgo , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Estados Unidos , Medición de Riesgo , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Índice de Severidad de la Enfermedad , Recuperación de la Función , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad
16.
JACC Cardiovasc Interv ; 17(16): 1916-1931, 2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-39197990

RESUMEN

BACKGROUND: Tricuspid regurgitation (TR) is highly prevalent in the transcatheter aortic valve replacement (TAVR) population, but clear management guidelines are lacking. OBJECTIVES: The aims of this study were to elucidate the prevalence and consequences of severe TR in patients with aortic stenosis undergoing TAVR and to examine the change in TR post-TAVR, including predictors of improvement and its impact on longer term mortality. METHODS: Using Centers for Medicare and Medicaid Services-linked TVT (Transcatheter Valve Therapy) Registry data, a propensity-matched analysis was performed among patients undergoing TAVR with baseline mild, moderate, or severe TR. Kaplan-Meier estimates were used to assess the impact of TR on 3-year mortality. Multivariable analysis identified predictors of 30-day TR improvement. RESULTS: Of the 312,320 included patients, 84% had mild, 13% moderate, and 3% severe TR. In a propensity-matched cohort, severe baseline TR was associated with higher in-hospital mortality (2.5% vs 2.1% for moderate TR and 1.8% for mild TR; P = 0.009), higher 1-year mortality (24% vs 19.6% for moderate TR and 16.6% for mild TR; P < 0.0001), and 3-year mortality (54.2% vs 48.5% for moderate TR and 43.3% for mild TR; P < 0.0001). Among the patients with severe TR at baseline, 76.4% improved to moderate or less TR 30 days after TAVR. Baseline mitral regurgitation moderate or greater, preserved ejection fraction, higher aortic valve gradient, and better kidney function predicted TR improvement after TAVR. However, severe 30-day residual TR was associated with higher 1-year mortality (27.4% vs 18.7% for moderate TR and 16.8% for mild TR; P < 0.0001). CONCLUSIONS: Severe baseline and 30-day residual TR after TAVR are associated with increased mortality up to 3 years. This analysis identifies a higher risk group that could be evaluated for the recently approved tricuspid interventions.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Mortalidad Hospitalaria , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia de la Válvula Tricúspide , Humanos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano de 80 o más Años , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Anciano , Estados Unidos/epidemiología , Factores de Riesgo , Factores de Tiempo , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Valvuloplastia con Balón/mortalidad , Valvuloplastia con Balón/efectos adversos , Medición de Riesgo , Prevalencia , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Estudios Retrospectivos , Centers for Medicare and Medicaid Services, U.S. , Hemodinámica
17.
Eur J Med Res ; 29(1): 407, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39103966

RESUMEN

BACKGROUND: Impaired hospitalizations for heart failure (HHF) and mortality are associated with tricuspid regurgitation (TR). OBJECTIVES: The objective of this study was to investigate the benefit of transcatheter tricuspid valve replacement (TTVR) over guideline-directed medical therapy (GDMT) in patients with symptomatic severe TR. METHODS: Between May 2020 and April 2023, 88 patients with symptomatic severe TR were treated in our center. Of these, 57 patients received GDMT alone, and 31 patients underwent combined TTVR and GDMT. We collected and analyzed baseline data, and follow-up information for both groups. The primary endpoints were all-cause mortality and the combined endpoint (including all-cause mortality and HHF). RESULTS: At a median follow-up of 20 (IQR 10-29) months, significant improvements were shown in TR severity, right ventricular function, and dimensions in TTVR group (all P < 0.001). It also resulted in superior survival rates (75.8% vs. 48.4%, P = 0.019), improved freedom from combined endpoint (61.5% vs. 45.9%, P = 0.007) and fewer major adverse events. After stratification by TRI-SCORE, the subgroup with < 6 points in the TTVR group exhibited a significant difference in the combined endpoint compared to the other subgroups (all P < 0.05), while no significant differences were observed in the GDMT subgroups (P = 0.680). CONCLUSIONS: The utilization of LuX-Valve in TTVR effectively improves TR and is associated with lower rates of major adverse events, HHF and all-cause mortality. The TRI-SCORE may help identify higher-benefit patients with TR from TTVR. Clinical trial registration ClinicalTrials.gov Protocol Registration System (NCT02917980).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Masculino , Femenino , Estudios Retrospectivos , Anciano , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Tricúspide/cirugía , Persona de Mediana Edad , Resultado del Tratamiento , Índice de Severidad de la Enfermedad , Cateterismo Cardíaco/métodos
18.
Curr Opin Pulm Med ; 30(5): 444-450, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39114937

RESUMEN

PURPOSE OF REVIEW: This review addresses treatment options for moderate to severe tricuspid valve regurgitation and the importance of right ventricular function and the pulmonary circulation. RECENT FINDINGS: Several interventional treatment options for severe tricuspid regurgitation have been developed including transcatheter edge-to-edge repair, annuloplasty and valve replacement. So far, transcatheter edge-to-edge repair is most frequently used with procedural success rates of more than 95% and improvements in functional and quality of life parameters for up to 2 years. Right ventricular function as well as pulmonary artery pressure and resistance levels are important outcome predictors. Mean pulmonary artery pressure more than 30 mmHg, transpulmonary gradient more than 17 mmHg and right ventricular to pulmonary artery coupling ratio less than 0.406 indicate poor outcome. SUMMARY: Despite the remarkable safety of interventional treatment of severe tricuspid regurgitation right ventricular dysfunction and abnormal pulmonary hemodynamics are important determinants of procedural success and clinical outcome.Complete hemodynamic work-up should be an integral part of prerepair assessment although validated data predicting outcome are limited.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Circulación Pulmonar , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/fisiopatología , Circulación Pulmonar/fisiología , Válvula Tricúspide/cirugía , Válvula Tricúspide/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anuloplastia de la Válvula Cardíaca/métodos , Disfunción Ventricular Derecha/fisiopatología , Hemodinámica/fisiología , Función Ventricular Derecha/fisiología , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Calidad de Vida
19.
BMC Infect Dis ; 24(1): 766, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39090536

RESUMEN

BACKGROUND: Coxiella burnetii is a bacterium with extreme tenacity and contagiousness that is mainly transmitted by inhalation of contaminated aerosols. Nevertheless, a transmission by ticks is under discussion. We report a case of Q fever in an urban environment and far away from sheep breeding that caused a rare right-sided endocarditis. CASE PRESENTATION: A 55-year-old man who was in good health before the event developed a C. burnetii -endocarditis of the tricuspid valve. He had no contact with sheep and no recent travel in a rural or even endemic area. The infection originated in a strictly urban environment, and the patient's occupation as a cemetery gardener in Berlin, coupled with the close temporal and local exposure to wild boar, made a transmission by these animals a plausible hypothesis. The infection was confirmed by the German Reference Laboratory, and the patient recovered completely after treatment with doxycycline and hydrochlorquine. CONCLUSIONS: The specialities of this case report are the right-sided endocarditis and the transmission of C. burnetii in a metropolitan area without sheep contact. We think that this case should serve to increase awareness of the potential for Q fever infection even in non-rural areas.


Asunto(s)
Coxiella burnetii , Endocarditis Bacteriana , Fiebre Q , Válvula Tricúspide , Fiebre Q/transmisión , Fiebre Q/microbiología , Fiebre Q/diagnóstico , Fiebre Q/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Humanos , Válvula Tricúspide/microbiología , Endocarditis Bacteriana/microbiología , Endocarditis Bacteriana/transmisión , Endocarditis Bacteriana/tratamiento farmacológico , Coxiella burnetii/aislamiento & purificación , Animales , Antibacterianos/uso terapéutico , Doxiciclina/uso terapéutico , Ovinos
20.
Future Cardiol ; 20(5-6): 281-286, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38975696

RESUMEN

One of the most common complications of tricuspid valve replacement is atrioventricular block (AVB), often requiring permanent pacing. The endocardial pacemaker lead, placed in the right ventricle, may sometimes interfere with the implanted prosthesis, causing its early dysfunction and the need for alternative sites of pacing. To the best of our knowledge, we present the first case of a successful combined percutaneous procedure consisting of the implantation of two leads in the coronary sinus for univentricular bifocal pacing and a transcatheter tricuspid valve-in-valve implantation in a young patient with severe dysfunction of the tricuspid bioprosthesis, requiring permanent pacing for a postsurgical complete atrioventricular block.


Tricuspid valve replacement with surgery can often lead to cardiac rhythm disorders requiring a permanent pacemaker. This device may occasionally damage the tricuspid prosthesis. We present the first case of a combined procedure of tricuspid valve replacement and device implantation distant from the prosthesis without the need for a surgical approach in a young patient with severe tricuspid prosthesis malfunctioning and permanent pacing.


Asunto(s)
Cateterismo Cardíaco , Estimulación Cardíaca Artificial , Seno Coronario , Implantación de Prótesis de Válvulas Cardíacas , Válvula Tricúspide , Humanos , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Seno Coronario/cirugía , Cateterismo Cardíaco/métodos , Estimulación Cardíaca Artificial/métodos , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/etiología , Bioprótesis , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico , Marcapaso Artificial , Femenino , Masculino , Adulto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA