Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 975
Filtrar
1.
Zhonghua Jie He He Hu Xi Za Zhi ; 47(9): 815-826, 2024 Sep 12.
Artículo en Chino | MEDLINE | ID: mdl-39266479

RESUMEN

Objective: To study the dynamic pathological characteristics of lung tissue in a Nano-ITO induced rat model of indium lung disease and to guide clinical and basic scientific research to further explore the mechanisms of pulmonary interstitial injury and pulmonary alveolar proteinosis (PAP). Methods: Dose-response (three divided doses) and time-course studies (six exposure periods) were performed to investigate the pulmonary toxicity induced by Nano-ITO. At the end of the experiment, cytokine levels and oxidative stress were analyzed in the bronchoalveolar lavage fluid. Rat lung tissues were also collected for staining with H&E, PAS, Masson's, Oil Red O, and Sirius Red. Ultrastructure of lung tissue cells was observed by transmission electron microscopy. Expression of IL-1ß, HO-1, SP-A was observed by immunohistochemistry, and the expression of α-SMA was observed by immunofluorescence. Results: Nano-ITO intratracheal instillation caused pulmonary toxicity by inducing acute inflammation at 3 days, granuloma (nodule) formation and collagen hyperplasia at 14 days, and alveolar proteinosis at 56 days post-exposure. Pathological features of lung tissue included typical alveolar exudates, cellular fibrous nodules, enlarged alveolar fat droplet fusion, cholesterol crystal granuloma and pulmonary alveolar proteinosis. The intra-alveolar eosinophilic material (multilamellated, lattice-shaped, and myelin-like structure) showed abnormal lamellar bodies (features of alveolar type Ⅱ epithelial cells) and abundant rough endoplasmic reticulum and mitochondria (features of fibroblasts) on transmission electron microscopy of the lung tissue from rats exposed to Nano-ITO on the 84th day. Cellular pathology revealed that a large amount of amorphous PAS stain-positive substances appear in BALF at 28 days post-exposure, and pink granular protein-like substances can be seen in alveolar macrophages. Conclusions: There are three characteristic developmental stages in Nano-ITO induced pulmonary injury in rats, acute inflammation, granuloma (nodule) formation and collagen proliferation, and pulmonary alveolar proteinosis, which provide a reference feature model for the pathogenesis of indium lung disease.


Asunto(s)
Modelos Animales de Enfermedad , Indio , Pulmón , Animales , Ratas , Indio/efectos adversos , Indio/toxicidad , Masculino , Pulmón/patología , Pulmón/metabolismo , Ratas Sprague-Dawley , Proteinosis Alveolar Pulmonar/inducido químicamente , Proteinosis Alveolar Pulmonar/patología , Titanio/efectos adversos , Titanio/toxicidad , Enfermedades Pulmonares/inducido químicamente , Enfermedades Pulmonares/patología , Enfermedades Pulmonares/etiología , Líquido del Lavado Bronquioalveolar , Estrés Oxidativo
2.
Medicine (Baltimore) ; 103(30): e39077, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39058869

RESUMEN

RATIONALE: Raney clips are commonly used in neurosurgical procedures to hold the scalp in place and stop bleeding during surgery. The removal of Raney clips is often the last process during cranial surgery prior to the closure of skin incision. Thus, a Raney clip found underneath the titanium mesh resulting in fever is a very rare occurrence. PATIENT CONCERNS: An 18-year-old male patient underwent cranial surgery due to intracranial abscess in the frontal lobe and subsequently underwent frontal skull repair using titanium mesh during which a Raney clip was unintentional left underneath the titanium mesh resulting in fever. DIAGNOSIS: A thin-slice computed tomography (CT) scan was used to identify the Raney clip. INTERVENTION: A third surgery was performed to remove the Raney clip. OUTCOMES: The patient fever total resolved after the third surgery with no further neurological deficits and 2-years follow-up revealed the patient is well and go about his daily activities. LESSONS: It is crucial to ensure that all foreign objects are removed after the surgery by counting all instruments used at and after each step during the operation, including all Raney clips. This will help prevent complications and ensure the safety as well as the well-being of the patient.


Asunto(s)
Instrumentos Quirúrgicos , Mallas Quirúrgicas , Titanio , Humanos , Masculino , Adolescente , Mallas Quirúrgicas/efectos adversos , Titanio/efectos adversos , Instrumentos Quirúrgicos/efectos adversos , Cuerpos Extraños/cirugía , Tomografía Computarizada por Rayos X , Absceso Encefálico/cirugía , Absceso Encefálico/etiología , Procedimientos Neuroquirúrgicos/efectos adversos , Procedimientos Neuroquirúrgicos/métodos , Fiebre/etiología , Complicaciones Posoperatorias/cirugía , Complicaciones Posoperatorias/etiología , Craneotomía/efectos adversos , Craneotomía/instrumentación
3.
Sci Rep ; 14(1): 16441, 2024 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-39013937

RESUMEN

Cement mediated peri-implantitis accounts for 1.9-75% of dental implant failures associated with peri-implant diseases. This study evaluated the biological impact of dental cements on osseointegrated implants using Lewis rats. Twenty-two rats were distributed into 6 groups: negative control (NC) soft diet (SD), and hard diet (HD); positive control SD and HD (n = 3); Implant + bio-ceramic Cement (BC) SD and HD which included contralateral Sham sites (n = 5). Titanium implants were placed on either side of the maxillae and allowed to heal for 14 days. Later, both sides of experimental groups underwent a re-entry surgery to simulate clinical cementation. The right side received 0.60 mg of BC. At 14 days post cement application, maxillae were harvested for clinical, microtomographic, and histological evaluations. Clinical and microtomographic evaluations indicated evidence of extensive inflammation and circumferential bone resorption around BC implants in comparison to NC. Histology revealed cement particles surrounded by inflammatory infiltrate in the implant area accompanied by biofilm for SD groups. Both sides of BC indicated intensive bone resorption accompanied by signs of osteolysis when compared to NC. Cemented groups depicted significantly lower bone to implant contact when compared to NC. In conclusion, residual cement extravasation negatively impacted osseointegrated implants after re-entry surgeries.


Asunto(s)
Cementos Dentales , Implantes Dentales , Periimplantitis , Microtomografía por Rayos X , Animales , Ratas , Implantes Dentales/efectos adversos , Periimplantitis/patología , Periimplantitis/etiología , Masculino , Ratas Endogámicas Lew , Oseointegración , Titanio/efectos adversos , Modelos Animales de Enfermedad , Maxilar/cirugía
4.
Sci Rep ; 14(1): 16847, 2024 07 22.
Artículo en Inglés | MEDLINE | ID: mdl-39039225

RESUMEN

To investigate the wear and corrosion of titanium alloy spinal implants in vivo, we evaluated removed implants and their surrounding scar tissues from 27 patients between May 2019 and April 2021. We performed scanning electron microscopy, energy-dispersive X-ray spectroscopy, and histological analysis. The results revealed metal-like particles in the soft tissues of seven patients, without any considerable increase in inflammatory cell infiltration. Patients with fractures showed lower percentages of wear and corrosion compared with other patients (42% and 17% vs. 59% and 26%). Polyaxial screws exhibited higher wear and corrosion percentages (53% and 23%) compared with uniaxial screws (39% and 3%), although in patients with fracture, the reverse was observed (20% and 0% vs. 39% and 3%). We found that titanium alloy spinal implants experience some degree of wear and corrosion in vivo. The titanium alloy particles formed by wear exhibited good histocompatibility, not causing inflammation, foreign body reactions, or osteolysis. Therefore, spinal implants should be removed cautiously when treating titanium alloy spinal metallosis. The wear and corrosion of the implants increase with the increase in implantation time, although the screw structure does not significantly affect these changes.


Asunto(s)
Aleaciones , Titanio , Titanio/química , Titanio/efectos adversos , Corrosión , Aleaciones/química , Persona de Mediana Edad , Masculino , Humanos , Femenino , Anciano , Adulto , Microscopía Electrónica de Rastreo , Tornillos Óseos/efectos adversos , Prótesis e Implantes/efectos adversos , Ensayo de Materiales
5.
Int J Mol Sci ; 25(11)2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38892068

RESUMEN

Food-grade titanium dioxide (E171) and zinc oxide nanoparticles (ZnO NPs) are common food additives for human consumption. We examined multi-organ toxicity of both compounds on Wistar rats orally exposed for 90 days. Rats were divided into three groups: (1) control (saline solution), (2) E171-exposed, and (3) ZnO NPs-exposed. Histological examination was performed with hematoxylin-eosin (HE) staining and transmission electron microscopy (TEM). Ceramide (Cer), 3-nitrotyrosine (NT), and lysosome-associated membrane protein 2 (LAMP-2) were detected by immunofluorescence. Relevant histological changes were observed: disorganization, inflammatory cell infiltration, and mitochondrial damage. Increased levels of Cer, NT, and LAMP-2 were observed in the liver, kidney, and brain of E171- and ZnO NPs-exposed rats, and in rat hearts exposed to ZnO NPs. E171 up-regulated Cer and NT levels in the aorta and heart, while ZnO NPs up-regulated them in the aorta. Both NPs increased LAMP-2 expression in the intestine. In conclusion, chronic oral exposure to metallic NPs causes multi-organ injury, reflecting how these food additives pose a threat to human health. Our results suggest how complex interplay between ROS, Cer, LAMP-2, and NT may modulate organ function during NP damage.


Asunto(s)
Ceramidas , Nanopartículas del Metal , Ratas Wistar , Titanio , Óxido de Zinc , Animales , Óxido de Zinc/toxicidad , Titanio/toxicidad , Titanio/efectos adversos , Ratas , Ceramidas/metabolismo , Nanopartículas del Metal/química , Nanopartículas del Metal/toxicidad , Masculino , Administración Oral , Proteína 2 de la Membrana Asociada a los Lisosomas/metabolismo , Tirosina/análogos & derivados , Tirosina/metabolismo , Hígado/efectos de los fármacos , Hígado/metabolismo , Hígado/patología , Riñón/efectos de los fármacos , Riñón/metabolismo , Riñón/patología
6.
Int J Nanomedicine ; 19: 5245-5267, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38855732

RESUMEN

The development of metallic joint prostheses has been ongoing for more than a century alongside advancements in hip and knee arthroplasty. Among the materials utilized, the Cobalt-Chromium-Molybdenum (Co-Cr-Mo) and Titanium-Aluminum-Vanadium (Ti-Al-V) alloys are predominant in joint prosthesis construction, predominantly due to their commendable biocompatibility, mechanical strength, and corrosion resistance. Nonetheless, over time, the physical wear, electrochemical corrosion, and inflammation induced by these alloys that occur post-implantation can cause the release of various metallic components. The released metals can then flow and metabolize in vivo, subsequently causing potential local or systemic harm. This review first details joint prosthesis development and acknowledges the release of prosthetic metals. Second, we outline the metallic concentration, biodistribution, and elimination pathways of the released prosthetic metals. Lastly, we discuss the possible organ, cellular, critical biomolecules, and significant signaling pathway toxicities and adverse effects that arise from exposure to these metals.


Asunto(s)
Metales , Humanos , Animales , Metales/química , Metales/farmacocinética , Prótesis Articulares de Metal sobre Metal/efectos adversos , Distribución Tisular , Titanio/química , Titanio/farmacocinética , Titanio/toxicidad , Titanio/efectos adversos , Prótesis Articulares/efectos adversos , Diseño de Prótesis , Aleaciones/farmacocinética , Aleaciones/química , Aleaciones/toxicidad
7.
J Trace Elem Med Biol ; 84: 127464, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38703537

RESUMEN

INTRODUCTION: Titanium is considered to be an inert material owing to the ability of the material to form a passive titanium oxide layer. However, once the titanium oxide layer is lost, it can lead to exposure of the underlying titanium substructure and can undergo corrosion. SUMMARY: The article explores the role of titanium ions and particles from dental implants on cells, cytokine release, and on the systemic redistribution of these particles as well as theories proposed to elucidate the effects of these particles on peri-implant inflammation based on evidence from in-vitro, human, and animal studies. Titanium particles and ions have a pro-inflammatory and cytotoxic effect on cells and promote the release of pro-inflammatory mediators like cytokines. Three theories to explain etiopathogenesis have been proposed, one based on microbial dysbiosis, the second based on titanium particles and ions and the third based on a synergistic effect between microbiome and titanium particles on the host. CONCLUSION: There is clear evidence from in-vitro and limited human and animal studies that titanium particles released from dental implants have a detrimental effect on cells directly and through the release of pro-inflammatory cytokines. Future clinical and translational studies are required to clarify the role of titanium particles and ions in peri-implant inflammation and the etiopathogenesis of peri-implantitis.


Asunto(s)
Citocinas , Implantes Dentales , Titanio , Humanos , Implantes Dentales/efectos adversos , Titanio/química , Titanio/efectos adversos , Citocinas/metabolismo , Corrosión , Animales
10.
Clin Implant Dent Relat Res ; 26(4): 671-678, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38573022

RESUMEN

PURPOSE: The aim of this study was to determine clinically and genetically the allergic effects of titanium and poly-ether-ether-ketone (PEEK) implants following loading in rabbit tibias. MATERIALS AND METHODS: This study included 18 white New Zealand male rabbits (n = 18) divided evenly into three groups: control, titanium (Ti), and PEEK (P). Clinically, the allergenic effect of titanium and PEEK was investigated by detecting the effect on lymph nodes. Furthermore, RT-PCR and ELISA were used to detect the expression of certain genes IL-6, TNF-α, OPG, RANKL, and RUNX-2 through both types of implants. RESULTS: Our findings demonstrated that titanium implants induced enlarged lymph nodes, which PEEK did not. Overall, RT-PCR and ELISA techniques revealed that Ti implants had higher expression of the inflammatory genes IL-6 and TNF-α. Ti had the highest expression in OPG findings, while PEEK had the lowest. RANKL expression was highest in the control group and lowest in the PEEK group. RUNX-2 is the highest for the control group and the lowest for the titanium group. CONCLUSION: Although titanium implants elicited greater allergy responses than PEEK implants, titanium has the highest expression of bone formation genes and the lowest expression of bone resorption genes, making it preferable to PEEK.


Asunto(s)
Benzofenonas , Cetonas , Polímeros , Titanio , Animales , Conejos , Titanio/efectos adversos , Masculino , Hipersensibilidad/etiología , Implantes Dentales/efectos adversos , Polietilenglicoles , Interleucina-6/metabolismo
11.
Acta Biomater ; 180: 128-139, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38636789

RESUMEN

Titanium as the leading implant material in locked plating is challenged by polymers such as carbon fiber-reinforced polyetheretherketone (CFR-PEEK), which became the focus of interest of researchers and manufacturers in recent years. However, data on human tissue response to these new implant materials are rare. Osteosynthesis plates and peri­implant soft tissue samples of 16 healed proximal humerus fractures were examined (n = 8 CFR-PEEK, n = 8 titanium). Soft tissue was analyzed by immunohistochemistry and µCT. The entrapped foreign bodies were further examined for their material composition by FTIR. To gain insight into their origin and formation mechanism, explanted and new plates were evaluated by SEM, EDX, profilometry and HR-CT. In the peri­implant soft tissue of the CFR-PEEK plates, an inflammatory tissue reaction was detected. Tissues contained foreign bodies, which could be identified as tantalum wires, carbon fiber fragments and PEEK particles. Titanium particles were also found in the peri­implant soft tissue of the titanium plates but showed a less intense surrounding tissue inflammation in immunohistochemistry. The surface of explanted CFR-PEEK plates was rougher and showed exposed and broken carbon fibers as well as protruding and deformed tantalum wires, especially in used screw holes, whereas scratches were identified on the titanium plate surfaces. Particles were present in the peri­implant soft tissue neighboring both implant materials and could be clearly assigned to the plate material. Particles from both plate materials caused detectable tissue inflammation, with more inflammatory cells found in soft tissue over CFR-PEEK plates than over titanium plates. STATEMENT OF SIGNIFICANCE: Osteosynthesis plates are ubiquitously used in various medical specialties for the reconstruction of bone fractures and defects and are therefore indispensable for trauma surgeons, ENT specialists and many others. The leading implant material are metals such as titanium, but recently implants made of polymers such as carbon fiber-reinforced polyetheretherketone (CFR-PEEK) have become increasingly popular. However, little is known about human tissue reaction and particle generation related to these new implant types. To clarify this question, 16 osteosynthesis plates (n = 8 titanium and n = 8 CFR-PEEK) and the overlying soft tissue were analyzed regarding particle occurrence and tissue inflammation. Tissue inflammation is clinically relevant for the development of scar tissue, which is discussed to cause movement restrictions and thus contributes significantly to patient outcome.


Asunto(s)
Benzofenonas , Placas Óseas , Fibra de Carbono , Carbono , Inflamación , Cetonas , Polietilenglicoles , Polímeros , Titanio , Humanos , Cetonas/química , Titanio/química , Titanio/efectos adversos , Polietilenglicoles/química , Polímeros/química , Fibra de Carbono/química , Carbono/química , Masculino , Inflamación/patología , Femenino , Persona de Mediana Edad , Anciano , Adulto
12.
Int Immunopharmacol ; 129: 111655, 2024 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-38340423

RESUMEN

Wear particles generated from the surface of implanted prostheses can lead to peri-implant osteolysis and subsequent aseptic loosening. In the inflammatory environment, extensive formation and activation of osteoclasts are considered the underlying cause of peri-implant osteolysis. Current medications targeting osteoclasts for the treatment of particle-induced bone resorption are not ideal due to significant side effects. Therefore, there is an urgent need to develop more effective drugs with fewer side effects. Norcantharidin (NCTD), a derivative of cantharidin extracted from blister beetles, is currently primarily used for the treatment of solid tumors in clinical settings. However, the potential role of NCTD in treating aseptic loosening of the prosthesis has not been reported. In this study, the in vitro results demonstrated that NCTD could effectively inhibit the formation of osteoclasts and bone resorption induced by the RANKL. Consistently, NCTD strongly inhibited RANKL-induced mRNA and protein levels of c-Fos and NFATc1, concomitant with reduced expression of osteoclast specific genes including TRAP, CTR and CTSK. The in vivo data showed that NCTD exerted significant protective actions against titanium particle-induced inflammation and subsequent osteolysis. The molecular mechanism investigation revealed that NCTD could suppress the activations of RANKL-induced MAPK (p38, ERK). Overall, these findings support the potential use of NCTD for the treatment of aseptic loosening following total joint arthroplasty.


Asunto(s)
Resorción Ósea , Compuestos Bicíclicos Heterocíclicos con Puentes , Osteólisis , Animales , Ratones , Osteoclastos , Osteólisis/inducido químicamente , Osteólisis/tratamiento farmacológico , Osteólisis/metabolismo , Titanio/efectos adversos , FN-kappa B/metabolismo , Resorción Ósea/inducido químicamente , Resorción Ósea/tratamiento farmacológico , Resorción Ósea/patología , Ligando RANK/metabolismo , Osteogénesis , Ratones Endogámicos C57BL
13.
Dermatitis ; 35(3): 242-245, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38190118

RESUMEN

Background: Although most patients do not develop hypersensitivity reactions to metals in implanted devices, when they do occur, significant morbidity can result. Titanium-based systems are often considered as an alternative option in metal-allergic patients; however, there are few studies published on titanium allergy and allergic reactions to titanium in implants may be overlooked in clinical practice. Methods: Our aim was to further characterize a single institution's experience with titanium patch testing and evaluation of titanium allergy. We performed a retrospective medical record review of 166 patients evaluated for titanium contact allergy between January 2018-August 2023. Of the 166 patients in our cohort, 67 were referred for pre-implant patch testing and 64 for post-implant patch testing; 35 were tested for reasons unrelated to an implant. Results: Twenty-six of the 166 patients were PTP to titanium (15.7% positive rate). Titanium PTP rates were higher for post-implant cases (28.1%, 18/64) compared to pre-implant cases (6.0%, 4/67) (χ2 9.97, p = 0.002). Among 18 titanium PTPs identified for the 64 post-implant cases, 8 were likely relevant, 8 possibly relevant, and 2 not likely relevant. Conclusions: Further studies should be performed to evaluate the incidence of allergy to titanium implants and to continue surveillance of changes in sensitization rates.


Asunto(s)
Dermatitis Alérgica por Contacto , Pruebas del Parche , Titanio , Humanos , Titanio/efectos adversos , Estudios Retrospectivos , Dermatitis Alérgica por Contacto/etiología , Dermatitis Alérgica por Contacto/diagnóstico , Masculino , Femenino , Persona de Mediana Edad , Adulto , Prótesis e Implantes/efectos adversos , Anciano
15.
World Neurosurg ; 182: e270-e275, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38006935

RESUMEN

OBJECTIVE: Seizures are one of the complications that can occur after cranioplasty (CP). In some regions, titanium mesh remains the material of choice for CP. However, risk factors for seizures after titanium CP have been less studied. The purpose of this study was to identify potential risk factors for early seizures (≤7 days) and late seizures (>8 days) after titanium CP in a single institution. METHODS: A retrospective review was conducted of 241 consecutive patients who received titanium CP at the First Affiliated Hospital of Harbin Medical University from January 2016 to December 2020. Univariate and multivariable logistic regression analyses were performed to determine the independent risk factors for new-onset seizures after titanium CP. RESULTS: Fifteen patients (6.22%) experienced early post-CP seizures, and late post-CP seizures were observed in 81 patients (33.61%). A flaccid concave cranial defect (P = 0.042) was associated with early post-CP seizures, whereas hypertension (P < 0.001) was the only significant predictor for late seizures after titanium CP. CONCLUSIONS: Seizure is a common complication after titanium CP, especially in patients who do not receive prophylactic antiepileptic drugs before the procedure. Risk factors for new-onset seizures at different periods after titanium CP were found to be different. In addition, radiologic factors before titanium CP may play a role in early new-onset seizures after titanium CP and should not be ignored.


Asunto(s)
Craniectomía Descompresiva , Titanio , Humanos , Titanio/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Craniectomía Descompresiva/efectos adversos , Convulsiones/epidemiología , Convulsiones/etiología , Convulsiones/prevención & control , Factores de Riesgo , Cráneo/cirugía , Estudios Retrospectivos
16.
Probiotics Antimicrob Proteins ; 16(2): 383-393, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36897512

RESUMEN

Wear particles generated from total joint replacements induce chronic osteolysis mediated by inflammatory upregulation, which leads to implant failure. Recent studies have suggested an important role of the gut microbiota in modulating the host's metabolism and immune system, leading to alterations in bone mass. Following gavage with P. histicola, micro-CT and HE staining revealed that osteolysis was significantly reduced in titanium (Ti)-treated mice. Immunofluorescence analysis revealed an increased macrophage (M)1/M2 ratio in the guts of Ti-treated mice, which decreased when P. histicola was added. P. histicola was also found to upregulate the tight junction proteins ZO-1, occludin, claudin-1, and MUC2 in the gut, reduce the levels of inflammatory factors IL-1ß, IL-6, IL-8, and TNF-α, primarily in the ileum and colon, and decrease the expression of IL-1ß and TNF-α and increase the level of IL-10 in the serum and cranium. Furthermore, P. histicola treatment resulted in a significant downregulation of CTX-1, RANKL, and RANKL/OPG. These findings demonstrate that P. histicola significantly mitigates osteolysis in Ti-treated mice by improving intestinal microbiota that repairs intestinal leakage and reduces systemic and local inflammation which in turn inhibits RANKL expression for bone resorption. P. histicola treatment may thus be therapeutically beneficial for particle-induced osteolysis.


Asunto(s)
Microbioma Gastrointestinal , Osteólisis , Prevotella , Ratones , Animales , Osteólisis/inducido químicamente , Osteólisis/metabolismo , Osteólisis/prevención & control , Factor de Necrosis Tumoral alfa , Osteoclastos/metabolismo , Titanio/efectos adversos , Titanio/metabolismo , Inflamación/tratamiento farmacológico , Inflamación/metabolismo
17.
Thorac Cardiovasc Surg ; 72(1): 70-76, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-36918153

RESUMEN

BACKGROUND: There are many factors that are known to increase the risk of sternal wound infection (SWI); some studies have reported that nickel is a risk factor for SWI. Titanium wires have only been used as an alternative to steel wires in patients with known allergy to nickel. However, there is a paucity of literature regarding the safety of using titanium wires compared to that on the safety of steel wires for sternum closure after cardiac surgery. Therefore, this study aimed to demonstrate the noninferiority of titanium wires, even in patients without a known allergy. METHODS: A total of 322 patients who underwent elective full median sternotomy were randomly assigned to sternal closure either by titanium wires (n = 161) or by stainless steel wires. RESULTS: Fourteen patients had sternal instability, six (3.7%) patients in the titanium group and eight (5%) patients in the stainless steel group (p = 0.585). There was no statistically significant difference between both groups in terms of postoperative wound infection (p = 0.147). Patients in the titanium group experienced statistically significant lower postoperative pain than those in the stainless steel group (p = 0.024). The wire type was not an independent risk factor for SI, as shown by univariate and logistic regression analyses. CONCLUSION: Titanium wires are a good alternative and have been proven to be safe and effective for sternal closure. The surgeon should be aware of the possibility of developing an allergic reaction to the wires, especially in patients with previous multiple allergic histories.


Asunto(s)
Hipersensibilidad , Esternotomía , Humanos , Esternotomía/efectos adversos , Estudios Prospectivos , Titanio/efectos adversos , Acero Inoxidable/efectos adversos , Níquel , Resultado del Tratamiento , Técnicas de Cierre de Heridas/efectos adversos , Esternón/cirugía , Acero , Hipersensibilidad/etiología , Hilos Ortopédicos/efectos adversos
18.
Contact Dermatitis ; 90(3): 201-210, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38148670

RESUMEN

After almost three-quarters of a century during which contact dermatologists have often struggled to comprehend the relationship between metal allergy and failure of metal-alloy containing implant, it is possible to say that a relationship does exist, particularly for cobalt and chromium, but also for nickel. There is still debate as to whether allergy develops as a consequent of failure but thenceforth contributes to it, or whether sensitisation starts first and induces failure secondarily-opinion probably favours the first. Metal-on-polypropylene articulations were associated with few metal allergic problems but now are less favoured by orthopaedists due to plastic wear products causing osteolysis and pseudotumour formation through local inflammation. New metal alloys are regularly being introduced such that interested dermatologists need to stay on top of the situation. The jury is still out as to whether the recent favouring of titanium-containing alloys will confirm them to be more inert allergenically. Case reports do show some clinical reactions to titanium-containing implants and patch test series have inferred sometimes quite a high background rate of allergy, but interpretation must be tempered by the awareness that titanium salts on patch testing have a tendency to cause irritant reactions. Blood monitoring of metal ion values is now recommended in certain situations after joint replacement and increasing levels may be an indication that allergy with joint failure can develop, in which case patch testing is indicated, and suggested series are available. Predictive patch testing, whilst generally not recommended in the past, has been introduced into some protocols often by non-dermatologists, such that it is now needed for temporo-mandibular joint and Nuss bar insertion, and it can be anticipated that this may become more commonplace in the future. One of the major current deficits for patch testers is standardised guidance on which preparation or preparations to use for suspected titanium allergy. One suggestion is 0.5% titanium sulphate in petrolatum, though experience in at least one centre suggests the use of a battery of titanium salts might be desirable.


Asunto(s)
Dermatitis Alérgica por Contacto , Hipersensibilidad , Humanos , Titanio/efectos adversos , Sales (Química) , Dermatitis Alérgica por Contacto/complicaciones , Aleaciones/efectos adversos , Metales , Hipersensibilidad/etiología
19.
Shanghai Kou Qiang Yi Xue ; 32(4): 428-431, 2023 Aug.
Artículo en Chino | MEDLINE | ID: mdl-38044740

RESUMEN

PURPOSE: To investigate the effects of metal materials for oral fixation and restoration on magnetic resonance imaging artifacts and the health of tissues around dental implants. METHODS: A total of 153 patients undergoing fixed oral restoration were selected from May 2018 to June 2020. They were divided according to the random number table method into group A (cobalt-chromium alloy, n=31), group B (nickel-chromium alloy, n=32), group C (titanium alloy, n=28), group D (pure titanium, n=29) and group E (gold alloy, n=33). The largest area of metal crown artifacts and the number of layers of the 5 groups were compared. The probing depth(PD), modified plaque index(mPLI), modified sulcus bleeding index(mSBI) and papilla index(PI) 6 months after restoration were evaluated.The data were statistically analyzed with SPSS 22.0 software package. RESULTS: One-way ANOVA showed that the largest area of metal crown artifacts and the number of layers involved in the 5 groups had significant differences(P<0.05). Pairwise comparison showed that the largest area of metal crown artifacts, and the number of involved layers in group E were significantly lower than those in groups A, B, C, and D(P<0.05). One-way ANOVA showed that there was no significant difference in PD, mPLI, mSBI and PI among 5 groups (P>0.05). Pairwise comparison showed that there was no significant difference in PD, mPLI, mSBI and PI between group A and group B,C,D and E (P>0.05). CONCLUSIONS: The artifacts produced by metal materials for oral fixation and restoration are closely related to the types of metal materials. Among them, cobalt-chromium alloys produce the largest artifacts, and gold alloys produce the smallest artifacts. The use of metal materials for oral fixation and restoration will not affect the health of tissues around dental implants.


Asunto(s)
Implantes Dentales , Titanio , Humanos , Titanio/efectos adversos , Implantes Dentales/efectos adversos , Artefactos , Coronas , Aleaciones de Oro , Imagen por Resonancia Magnética/métodos
20.
Mol Med Rep ; 28(5)2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37732549

RESUMEN

Wear particle­induced osteolysis is a serious complication that occurs in individuals with titanium (Ti)­based implants following long­term usage due to loosening of the implants. The control of excessive osteoclast differentiation and inflammation is essential for protecting against wear particle­induced osteolysis. The present study evaluated the effect of britanin, a pseudoguaianolide sesquiterpene isolated from Inula japonica, on osteoclastogenesis in vitro and Ti particle­induced osteolysis in vivo. The effect of britanin was examined in the osteoclastogenesis of mouse bone marrow­derived macrophages (BMMs) using TRAP staining, RT­PCR, western blotting and immunocytochemistry. The protective effect of britanin was examined in a mouse calvarial osteolysis model and evaluated using micro­CT and histomorphometry. Britanin inhibited osteoclast differentiation and F­actin ring formation in the presence of macrophage colony­stimulating factor and receptor activator of nuclear factor kB ligand in BMMs. The expression of osteoclast­specific marker genes, including tartrate­resistant acid phosphatase, cathepsin K, dendritic cell­specific transmembrane protein, matrix metallopeptidase 9 and nuclear factor of activated T­cells cytoplasmic 1, in the BMMs was significantly reduced by britanin. In addition, britanin reduced the expression of B lymphocyte­induced maturation protein­1, which is a transcriptional repressor of negative osteoclastogenesis regulators, including interferon regulatory factor­8 and B­cell lymphoma 6. Conversely, britanin increased the expression levels of anti­oxidative stress genes, namely nuclear factor erythroid­2­related factor 2, NAD(P)H quinone oxidoreductase 1 and heme oxygenase 1 in the BMMs. Furthermore, the administration of britanin significantly reduced osteolysis in a Ti particle­induced calvarial osteolysis mouse model. Based on these findings, it is suggested that britanin may be a potential therapeutic agent for wear particle­induced osteolysis and osteoclast­associated disease.


Asunto(s)
Osteogénesis , Osteólisis , Humanos , Animales , Ratones , Osteólisis/tratamiento farmacológico , Osteólisis/etiología , Titanio/efectos adversos , Osteoclastos , Citoesqueleto de Actina , Modelos Animales de Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA