Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.105
Filtrar
1.
Clinics (Sao Paulo) ; 79: 100478, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39226870

RESUMEN

BACKGROUND: Lower limb coronal alignment was thought to be a predictive factor for Unicompartmental Knee Arthroplasty (UKA) result. The tibial bony resection and implant position lead to joint line change postoperatively. Analysis was done to find out the correlation between these factors. METHODS: From 2019 to 2021, 90 medial Oxford UKA were implanted by a single surgeon. Hip Knee Ankle Angle (HKAA), Lateral Distal Femoral Angle (LDFA), Medial Proximal Tibial Angle (MPTA), and intraoperative bony resection thickness were measured. The medial joint line change was calculated. The correlation between joint line change and alignment change was evaluated. RESULTS: The mean tibial resection thickness was 4.3 mm. The mean tibial joint line was elevated by 2.3 mm, while the mean femoral joint line proximalized by 0.8 mm. HKAA changed from 8.4° varus preoperatively to 3.6° varus postoperatively. LDFA changed from 89.0° to 86.7°. MPTA changed from 85.6° to 86.6°. Preoperative HKAA showed a strong correlation with postoperative HKAA (p < 0.001), and preoperative MPTA showed a positive correlation with postoperative HKAA (p < 0.001). While preoperative LDFA had a negative correlation with postoperative HKAA (p < 0.001). The femoral joint line change and LDFA change had a significant correlation with HKAA change (p < 0.05). CONCLUSION: The change of joint line had no correlation with postoperative HKAA in Oxford UKA. Preoperative HKAA strongly correlated with postoperative HKAA; while preoperative smaller LDFA and larger MPTA had a moderate correlation with postoperative HKAA. The femoral joint line change and LDFA change had a weak to moderate correlation with HKAA change.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Masculino , Femenino , Anciano , Persona de Mediana Edad , Articulación de la Rodilla/cirugía , Tibia/cirugía , Estudios Retrospectivos , Fémur/cirugía , Prótesis de la Rodilla , Periodo Posoperatorio , Resultado del Tratamiento , Anciano de 80 o más Años , Osteoartritis de la Rodilla/cirugía
2.
Microsurgery ; 44(6): e31218, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39239787

RESUMEN

Pure vascularized periosteal transplants have been shown to be extremely effective at achieving rapid bone healing in children with biologically complex non-union. Free tibial and fibular periosteal transplants are generally indicated when large periosteal flaps are necessary. We report using a vascularized femoral myo-periosteal graft (VFMPG) to treat distal tibial osteotomy non-union in a six-year-old boy with congenital pseudarthrosis of the tibia. The graft consisted of a 9 cm myo-periosteal flap (after 50% of elastic retraction) that incorporated the vastus intermedius muscle and diaphyseal femoral periosteum nourished by the descending branch of the lateral circumflex femoral vessels. Plantaris medialis was used as a recipient vessel. Healing occurred 10 weeks after surgery. The patient resumed gait and sports activity without orthosis. No donor or recipient site complications occurred 17 months after surgery. Employing a VFMPG might be an alternative to other free or large vascularized periosteal flaps currently in use for complex pediatric non-unions.


Asunto(s)
Fémur , Periostio , Seudoartrosis , Colgajos Quirúrgicos , Humanos , Masculino , Seudoartrosis/cirugía , Seudoartrosis/congénito , Periostio/trasplante , Niño , Fémur/trasplante , Fémur/irrigación sanguínea , Fémur/cirugía , Colgajos Quirúrgicos/irrigación sanguínea , Osteotomía/métodos , Tibia/cirugía , Tibia/trasplante , Fracturas de la Tibia/cirugía
3.
Clin Sports Med ; 43(4): 649-660, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39232572

RESUMEN

Utilizing fresh distal tibia allograft in anterior glenoid reconstruction has emerged as a highly advantageous approach in addressing instances of failed anterior shoulder stabilization with glenoid bone loss. This procedure offers several benefits, including the absence of donor-site morbidity, restoration of significant glenoid defects, reestablishment of joint congruity with the humeral head, restoration of glenoid biomechanics, and the addition of cartilage to the glenoid. Furthermore, it provides a robust and reliable alternative for managing failed stabilization procedures, leading to improved clinical outcomes and a high graft healing rate, while maintaining a low occurrence of recurrent instability.


Asunto(s)
Trasplante Óseo , Inestabilidad de la Articulación , Articulación del Hombro , Humanos , Inestabilidad de la Articulación/cirugía , Trasplante Óseo/métodos , Articulación del Hombro/cirugía , Tibia/cirugía , Insuficiencia del Tratamiento
4.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(4): 758-765, 2024 Aug 25.
Artículo en Chino | MEDLINE | ID: mdl-39218602

RESUMEN

The use of a filling block can improve the initial stability of the fixation plate in the open wedge high tibial osteotomy (OWHTO), and promote bone healing. However, the biomechanical effects of filling block structures and materials on OWHTO remain unclear. OWHTO anatomical filling block model was designed and built. The finite element analysis method was adopted to study the influence of six filling block structure designs and four different materials on the stress of the fixed plate, tibia, screw, and filling block, and the micro-displacement at the wedge gap of the OWHTO fixation system. After the filling block was introduced in the OWHTO, the maximum von Mises stress of the fixation plate was reduced by more than 30%, the maximum von Mises stress of the tibia decreased by more than 15%, and the lateral hinge decreased by 81%. When the filling block was designed to be filled in the posterior position of the wedge gap, the maximum von Mises stress of the fixation system was 97.8 MPa, which was smaller than other filling methods. The minimum micro-displacement of osteotomy space was -2.9 µm, which was larger than that of other filling methods. Compared with titanium alloy and tantalum metal materials, porous hydroxyapatite material could obtain larger micro-displacement in the osteotomy cavity, which is conducive to stimulating bone healing. The results demonstrate that OWHTO with a filling block can better balance the stress distribution of the fixation system, and a better fixation effect can be obtained by using a filling block filled in the posterior position. Porous HA used as the material of the filling block can obtain a better bone healing effect.


Asunto(s)
Placas Óseas , Análisis de Elementos Finitos , Osteotomía , Impresión Tridimensional , Tibia , Osteotomía/métodos , Tibia/cirugía , Humanos , Fenómenos Biomecánicos , Estrés Mecánico , Tornillos Óseos
5.
Med Eng Phys ; 131: 104228, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39284654

RESUMEN

This study focuses on evaluating the failure resistance of a previously reduced tibia with internal fixation implants as PLate (PL) or InterMedullary Nail (IMN), subjected later to a tibial lateral trauma. To replicate this type of trauma, which can be caused by a road accident, a three-point bending test is considered using experimental tests and numerical simulations. The withstand evaluation of the tibia-PL and tibia-IMN structures was conducted by following the load transfer through, the bone and the used implants. The analysis, up to tibia failure, required the use of an elasto-plastic behavior law coupled to damage. The model parameters were identified using experimental tests. Il was shown that the tibia-IMN structure provided a bending resistant load up to three-times higher than the tibia-PL. In fact, the used screws for plate fixation induced a high level of stress in the vicinity of threaded region, leading to a crack initiation and a damage propagation. However, in tibia-IMN structure the highest stress was generated in the trapped zone between the loader and the nail, promoting crack formation. From a biomechanical point of view, the structure with IMN is safer than the structure with PL, whose fixation induces earlier damage in bone.


Asunto(s)
Ensayo de Materiales , Tibia , Fracturas de la Tibia , Tibia/cirugía , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/fisiopatología , Humanos , Placas Óseas , Fenómenos Biomecánicos , Pruebas Mecánicas , Estrés Mecánico , Fijación Interna de Fracturas/instrumentación , Análisis de Elementos Finitos , Clavos Ortopédicos
6.
PLoS One ; 19(9): e0309146, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39264941

RESUMEN

Tunnel widening is a frequent problem following arthroscopic ligament reconstruction surgery that may primarily arise from a graft-tunnel mismatch caused by errors in surgical instruments and methods. The present study aimed to observe the influence of current surgical instruments and methods on graft-tunnel matching. We established an in vitro model using porcine Achilles tendons and tibias, and compared traditional surgical instruments (control group) with custom instruments (experimental group). Graft measurements, bone-tunnel creation, and measurements of the maximum pullout force of the graft from the bone tunnel were performed. Results indicated that the measuring gauge developed by our research group (capable of accurate measurement of graft diameters) may mitigate errors arising from graft-diameter measurement using traditional measuring cylinders. Therefore, errors caused by current surgical instruments and surgical methods led to an increase in graft-tunnel mismatches. The degree of mismatch was greater at the tibial end than at the femoral end.


Asunto(s)
Procedimientos de Cirugía Plástica , Tibia , Animales , Porcinos , Fenómenos Biomecánicos , Tibia/cirugía , Procedimientos de Cirugía Plástica/métodos , Tendón Calcáneo/cirugía , Ligamentos/cirugía , Fémur/cirugía
7.
Bull Hosp Jt Dis (2013) ; 82(4): 231-236, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-39259948

RESUMEN

BACKGROUND: An isolated medial patellofemoral ligament (MPFL) reconstruction (MPFLR) has been demonstrated to be an effective treatment option in the prevention of patellar instability, but there is growing support for performing a tibial tubercle osteotomy (TTO) in patients with an elevated tibial tubercle-trochlear groove distance. The purpose of this study was to evaluate the impact of adding a TTO to MPFLR on patient reported outcomes. METHODS: A retrospective review of patients who underwent MPFLR with or without TTO with a minimum of 12-month follow-up was performed. Patients in both groups were matched based on age, sex, and follow-up time. Recurrent instability (including re-dislocation and subluxation), visual analog scale (VAS) for pain score, Kujala score, and satisfaction were evaluated. RESULTS: There were 59 patients who underwent MPFLR with concomitant TTO performed at our institution and met our inclusion and exclusion criteria. These patients were then matched to patients undergoing isolated MPFLR based on demographics and follow-up time. The mean age was 25.0, 76.3% were female, and the mean follow-up time was 49 months. There was a significant difference in mean tibial tubercle-trochlear groove distance (19.8 ± 3.9 vs. 14.1 ± 2.8) between groups. There was no significant difference in VAS (1.48 ± 2.0 vs. 1.49 ± 2.1, p = 0.972), satisfaction (86.1% ± 24.2% vs. 81.2% ± 27.9, p = 0.311), or revision surgeries (10.2% vs. 10.2%) between groups. CONCLUSION: There was a low complication rate, excellent patient reported outcomes, and a low rate of recurrent patellar instability following TTO and MPFLR with allograft.


Asunto(s)
Inestabilidad de la Articulación , Osteotomía , Articulación Patelofemoral , Tibia , Humanos , Femenino , Osteotomía/métodos , Osteotomía/efectos adversos , Inestabilidad de la Articulación/cirugía , Inestabilidad de la Articulación/etiología , Inestabilidad de la Articulación/fisiopatología , Masculino , Estudios Retrospectivos , Adulto , Tibia/cirugía , Articulación Patelofemoral/cirugía , Articulación Patelofemoral/fisiopatología , Articulación Patelofemoral/diagnóstico por imagen , Adulto Joven , Resultado del Tratamiento , Procedimientos de Cirugía Plástica/métodos , Procedimientos de Cirugía Plástica/efectos adversos , Adolescente , Luxación de la Rótula/cirugía , Luxación de la Rótula/fisiopatología , Luxación de la Rótula/diagnóstico por imagen , Recurrencia , Ligamentos Articulares/cirugía , Ligamento Rotuliano/cirugía
9.
Top Companion Anim Med ; 62: 100905, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39117069

RESUMEN

The aim of this study was to develop a novel surgical technique for stifle arthrodesis in dogs using a semicircular saw for tibial and femoral ostectomies through a medial approach. Ten pelvic limbs from five canine cadavers underwent stifle arthrodesis. Prior to the surgical procedure, the limbs were radiographed to rule out musculoskeletal abnormalities. Additionally, the radiographs were used for surgical planning. For the tibial ostectomy, the center of the intercondylar eminences, the cranial limit of the tibial plateau, and the caudal cortex of the tibia were used as landmarks. In the femur, the groove of the insertion of the long digital extensor tendon and the caudal portion of the femoral cortex served as references. The most significant iatrogenic injury during the surgical procedures was the complete rupture of the long digital extensor tendon during the tibial cut in one of the stifles. Dome ostectomies facilitated interfragmentary contact, allowing for adjustment of the angulation between the fragments without the need for additional ostectomies or osteotomies. The medial approach provided a clear view of intra-articular structures without causing extensive damage to surrounding tissues. After the procedures, the limbs were radiographed to calculate angular measurements, and the final angulation (mean) of the knee joints was 134.7 ± 11°.


Asunto(s)
Artrodesis , Cadáver , Rodilla de Cuadrúpedos , Animales , Perros/cirugía , Artrodesis/veterinaria , Artrodesis/métodos , Rodilla de Cuadrúpedos/cirugía , Rodilla de Cuadrúpedos/diagnóstico por imagen , Tibia/cirugía , Osteotomía/veterinaria , Osteotomía/métodos , Fémur/cirugía
10.
Jt Dis Relat Surg ; 35(3): 473-482, 2024 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-39189555

RESUMEN

OBJECTIVES: The study focused on the ability to predict the need and size of femoral and tibial augmentation using standard two-dimensional (2D) templates and models created with three-dimensional (3D) printing in surgical planning. PATIENTS AND METHODS: This observational cohort study included 28 consecutive patients (22 females, 6 males; mean age: 71±7.3 years; range, 54 to 82 years) with periprosthetic joint infection recruited between March 2021 and September 2023 undergoing revision total knee arthroplasty revision (TKA). Standard planning was made using calibrated X-ray images. The 3D planning started with computed tomography scans to generate a 3D template of the distal femur and proximal tibia. The model was exported to a 3D printer to produce a patient-specific phantom. The surgery was then simulated on the 3D phantom using revision knee arthroplasty instrumentation to evaluate the appropriate augmentation to use until a correct alignment was obtained. RESULTS: Three-dimensional planning predicted the need for femoral and tibial augments in 22 (78.6%) cases at both the tibial and femoral components, while 2D planning correctly predicted the need for augmentation in 17 (60.7%) for the tibial side and 18 (64.3%) for the femoral side. The Cohen's kappa demonstrated a significant agreement between the 3D planning for the femoral metal block and the intraoperative requirement (kappa=0.553), whereas 2D planning showed only nonsignificant poor agreement (kappa=0.083). In contrast, the agreement between 2D or 3D preoperative planning for tibial augment and the intraoperative requirement was nonsignificant (kappa=0.130 and kappa=0.158, respectively). On the femoral side, 2D planning showed only a fair nonsignificant correlation (r=0.35, p=0.069), whereas 3D planning exhibited substantial agreement with the actual thickness of the implanted augment (r=0.65, p<0.001). On the tibial side, 3D and 2D planning showed substantial agreement with the actual size of implanted augments (3D planning, r=0.73, p<0.001; 2D planning, r=0.69, p<0.001). CONCLUSION: Prediction based on 3D computed tomography segmentation showed significant agreement with the intraoperative need for augmentations in revision TKA. The results suggest that planning with 3D printed models represents a stronger aid in this kind of surgery rather than standard 2D planning, providing greater accuracy in the prediction of the required augmentation in revision TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Impresión Tridimensional , Reoperación , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Femenino , Masculino , Anciano , Persona de Mediana Edad , Anciano de 80 o más Años , Tomografía Computarizada por Rayos X , Diseño de Prótesis , Tibia/cirugía , Tibia/diagnóstico por imagen , Fémur/cirugía , Fémur/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/cirugía
11.
Artif Intell Med ; 156: 102966, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39197376

RESUMEN

This comprehensive systematic review critically analyzes the current progress and challenges in automating transtibial prosthesis alignment. The manual identification of alignment changes in prostheses has been found to lack reliability, necessitating the development of automated processes. Through a rigorous systematic search across major electronic databases, this review includes the highly relevant studies out of an initial pool of 2111 records. The findings highlight the urgent need for automated alignment systems in individuals with transtibial amputation. The selected studies represent cutting-edge research, employing diverse approaches such as advanced machine learning algorithms and innovative alignment tools, to automate the detection and adjustment of prosthesis alignment. Collectively, this review emphasizes the immense potential of automated transtibial prosthesis alignment systems to enhance alignment accuracy and significantly reduce human error. Furthermore, it identifies important limitations in the reviewed studies, serving as a catalyst for future research to address these gaps and explore alternative machine learning algorithms. The insights derived from this systematic review provide valuable guidance for researchers, clinicians, and developers aiming to propel the field of automated transtibial prosthesis alignment forward.


Asunto(s)
Miembros Artificiales , Aprendizaje Automático , Tibia , Humanos , Tibia/cirugía , Diseño de Prótesis , Ajuste de Prótesis/métodos , Algoritmos
12.
PLoS One ; 19(8): e0309015, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39208149

RESUMEN

This prospective bi-center study aimed to analyze the outcomes of primary total knee arthroplasty using the Stemmable Tibia Attune system. A total of 100 patients who underwent primary total knee arthroplasty with Stemmable Tibia from January 2019 to December 2021 were enrolled in the study. Radiological outcomes (hip-knee-ankle axis and medial proximal tibial angle) were assessed preoperatively and postoperatively. Clinical outcomes (visual analog scale score, Hospital for Special Surgery score, Knee Society function score, Knee Society knee score, flexion contracture, further flexion, and range of motion) were analyzed preoperatively and at 6 weeks, 3 months, 6 months, 1 year, and 2 years postoperatively. Complications (periprosthetic joint infection and aseptic loosening) were examined. The hip-knee-ankle axis decreased (preoperative: 9.5° ± 6.3°, postoperative: 1.1° ± 2.7°), whereas the medial proximal tibial angle increased (preoperative: 84.6° ± 4.1°, postoperative: 89.8° ± 1.9°). The visual analog scale score, Hospital for Special Surgery score, Knee Society knee score, and Knee Society function score increased postoperatively. The Knee Society knee score indicated above good outcomes (100.0% and 99.0% at 1 and 2 years postoperatively, respectively). The Knee Society function score also showed above good results (98.0% and 93.0% at 1 and 2 years postoperatively, respectively). The range of motion significantly improved (p < 0.001): flexion contracture decreased from 9.10° ± 7.23° to 2.15° ± 2.87°, whereas further flexion increased from 136.05° ± 14.78° to 139.80° ± 10.02°. One patient developed periprosthetic joint infection; no early loosening was observed. In conclusion, Attune primary total knee arthroplasty with Stemmable Tibia not only is safe and effective but also leads to radiological and clinical improvements.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Rango del Movimiento Articular , Tibia , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Masculino , Femenino , Anciano , Estudios Prospectivos , Persona de Mediana Edad , Estudios de Seguimiento , Tibia/cirugía , Tibia/diagnóstico por imagen , Resultado del Tratamiento , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Prótesis de la Rodilla
13.
Zhonghua Wai Ke Za Zhi ; 62(9): 864-869, 2024 Sep 01.
Artículo en Chino | MEDLINE | ID: mdl-39090065

RESUMEN

Objective: To investigate the clinical and radiologic characteristics of children with congenital pseudarthrosis of the tibia (CPT) in a single center. Methods: This is a retrospective case series study. According to inclusion and exclusion criteria, clinical data of 497 children(507 limbs) with CPT who were treated at Department of Orthopedics, the Children's Hospital Affiliated to Xiangya School of Medicine, Central South University from January 2011 to December 2020 were collected. Baseline data included gender, age at initial visit, age at onset of symptoms, accompanying symptoms, domicile, whether first treated at our hospital, and treatment-related information such as surgical or conservative treatment, surgical complications, etc., were extracted and analyzed using the health information system. Imaging data of the children, including Crawford classification, bilateral leg lengths, presence of fibular pseudarthrosis, and location of pseudarthrosis along the tibia segment, were analyzed using the Picture Archiving and Communication System. Data were compared using independent sample t test or χ2 tests. Results: Among 497 children with CPT, there were 305 males (61.4%) and 192 females (38.6%). The age at initial visit was (3.6±3.2) years (range: 0.1 to 16.2 years). Neurofibromatosis type 1 (NF1) symptoms were positive in 340 children (68.4%), and negative in 157 children (31.6%). Among NF1-positive children, those with symptoms onset before 1 year of age were significantly more than NF1-negative children (74.1%(252/340) vs. 66.2%(104/157);χ2=9.24, P=0.001), and the proportion of fractures (92.9%,316/340) was significantly higher than that in the NF1-negative group (84.7%,133/157) (χ2=8.33, P=0.004). According to imaging data, Crawford type Ⅳ was the most common type, with 321 limbs (63.3%), followed by type Ⅱ in 100 limbs (19.7%), type Ⅲ in 54 limbs (10.7%) and type Ⅰ in 32 limbs (6.3%). Pseudarthrosis occurred in the proximal third of the tibia in 14 limbs (2.8%), in the middle third in 185 limbs (36.5%), and in the distal third in 308 limbs (60.8%). Seventy-four children (14.9 %) had associated fibular pseudarthrosis. The lateral proximal tibial angle was 86.91°±5.21°(range: 72.17° to 102.08°), and the lateral distal tibial angle was 87.27°±10.73°(range: 51.07° to 128.17°). A total of 421 children (84.7%) underwent surgical treatment with (3.1±2.4) surgeries performed per child (range:0 to 12 surgeries); 76 children (15.3%) received conservative treatment. Postoperative complications mainly included ankle valgus (77 cases), leg length discrepancy (71 cases),refracture (48 cases), osteomyelitis (11 cases), and hardware failure (10 cases). NF1-positive children underwent more surgeries than NF1-negative children ((5.1±2.2)times vs.(2.1±1.8)times;t=14.93,P<0.01). Conclusions: Crawford type Ⅳ is the most common type of CPT in children in this study. CPT predominantly occurs in the middle or distal third of the tibia. The majority of children with CPT experienced symptoms and were seen at outpatient clinics before the age of 3 years. The main surgical complications currently associated with CPT treatment are ankle valgus and leg length discrepancy. Compared with CPT without NF1, children with NF1-positive CPT tend to have earlier symptom onset and may require more frequent treatments.


Asunto(s)
Seudoartrosis , Tibia , Humanos , Estudios Retrospectivos , Femenino , Masculino , Seudoartrosis/congénito , Seudoartrosis/diagnóstico , Tibia/anomalías , Tibia/cirugía , Preescolar , Niño , Lactante
14.
Sensors (Basel) ; 24(16)2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39204964

RESUMEN

Total knee arthroplasty (TKA) is a well-established and successful treatment option for patients with end-stage osteoarthritis of the knee, providing high patient satisfaction. Robotic systems have been widely adopted to perform TKA in orthopaedic centres. The exact spatial positions of the femur and tibia are usually determined through pinned trackers, providing the surgeon with an exact illustration of the axis of the lower limb. The drilling of holes required for mounting the trackers creates weak spots, causing adverse events such as bone fracture. In the presented computational feasibility study, time differential electrical impedance tomography is used to locate the femur positions, thereby the difference in conductivity distribution between two distinct states s0 and s1 of the measured object is reconstructed. The overall approach was tested by simulating five different configurations of thigh shape and considered tissue conductivity distributions. For the cylinder models used for verification and reference, the reconstructed position deviated by about ≈1 mm from the actual bone centre. In case of models mimicking a realistic cross section of the femur position deviated between 7.9 mm 24.8 mm. For all models, the bone axis was off by about φ=1.50° from its actual position.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Estudios de Factibilidad , Fémur , Procedimientos Quirúrgicos Robotizados , Tibia , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Fémur/cirugía , Procedimientos Quirúrgicos Robotizados/métodos , Tibia/cirugía , Impedancia Eléctrica
15.
J Orthop Surg Res ; 19(1): 516, 2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39192371

RESUMEN

BACKGROUND: Accurate estimation of implant size before surgery is crucial in preparing for total knee arthroplasty. However, this task is time-consuming and labor-intensive. To alleviate this burden on surgeons, we developed a reliable artificial intelligence (AI) model to predict implant size. METHODS: We enrolled 714 patients with knee osteoarthritis who underwent total knee arthroplasty from March 2010 to February 2014. All surgeries were performed by the same surgeon using implants from the same manufacturer. We collected 1412 knee anteroposterior (AP) and lateral view x-ray images and retrospectively investigated the implant size. We trained the AI model using both AP and lateral images without any clinical or demographic information and performed data augmentation to resolve issues of uneven distribution and insufficient data. Using data augmentation techniques, we generated 500 images for each size of the femur and tibia, which were then used to train the model. Using data augmentation techniques, we generated 500 images for each size of the femur and tibia, which were then used to train the model. We used ResNet-101 and optimized the model with the aim of minimizing the cross-entropy loss function using both the Stochastic Gradient Descent (SGD) and Adam optimizer. RESULTS: The SGD optimizer achieved the best performance in internal validation. The model showed micro F1-score 0.91 for femur and 0.87 for tibia. For predicting within ± one size, micro F1-score was 0.99 for femur and 0.98 for tibia. CONCLUSION: We developed a deep learning model with high predictive power for implant size using only simple x-ray images. This could help surgeons reduce the time and labor required for preoperative preparation in total knee arthroplasty. While similar studies have been conducted, our work is unique in its use of simple x-ray images without any other data, like demographic features, to achieve a model with strong predictive power.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Inteligencia Artificial , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Femenino , Masculino , Estudios Retrospectivos , Anciano , Persona de Mediana Edad , Prótesis de la Rodilla , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/diagnóstico por imagen , Fémur/diagnóstico por imagen , Fémur/cirugía , Radiografía/métodos , Tibia/diagnóstico por imagen , Tibia/cirugía , Anciano de 80 o más Años
16.
Comput Methods Programs Biomed ; 255: 108330, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39121602

RESUMEN

PURPOSE: The progression of osteoarthritis in lateral compartment has been identified as a primary complication in medial unicompartmental knee arthroplasty (UKA) revisions, irrespective of whether employing fixed bearing (FB) or mobile bearing (MB) designs. Compared to the previous contact point analyses, the tibiofemoral contacts during knee movements are comprehended by a more comprehensive understanding of joint spaces. This study aims to dynamically map the joint spaces in the lateral compartment during the single-leg lunge following FB and MB UKA procedures, and compare them with the respective contralateral native knees. It is hypothesized that the significant change in joint space for post-UKA compared to their native knees. METHODS: Twelve patients with unilateral medial FB UKA and eleven patients with unilateral medial MB UKA were included and underwent computed tomography scans. The exclusion criteria included anterior cruciate ligament deficiency, postoperative knee pain, any postoperative complications, and musculoskeletal illnesses. A dual fluoroscopic imaging system was utilized to capture the single-leg lunge, and 2D-to-3D registration facilitated the visualization of knee motion. According to the knee motions, joint spaces on tibial and femoral surfaces in the lateral compartments of native, FB, and MB UKA knees were calculated and mapped. RESULTS: In comparison to the native knees, FB UKA knees exhibited significant increases in medial, lateral, central, and posterior joint spaces in the lateral compartment (p < 0.05), while MB UKA knees showed significant increases only in central and posterior joint spaces (p < 0.05). Moreover, FB UKA demonstrated greater increases in medial, central, and posterior joint spaces compared to MB UKA. Tibial varus and valgus during lunges, as well as the Oxford Knee Score (OKS) and Hip-Knee-Ankle angle (HKA), correlated with joint spaces. CONCLUSIONS: Dynamic joint space analysis provided a more comprehensive insight into contact dynamics. FB UKA led to an enlargement of joint spaces, whereas MB UKA resulted in joint spaces closer to native knees. These findings contribute to understanding potential postoperative complication in UKAs.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla , Humanos , Femenino , Masculino , Persona de Mediana Edad , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/cirugía , Anciano , Tomografía Computarizada por Rayos X , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/fisiopatología , Rango del Movimiento Articular , Tibia/diagnóstico por imagen , Tibia/cirugía , Fémur/diagnóstico por imagen , Fémur/cirugía
17.
BMC Musculoskelet Disord ; 25(1): 625, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39107761

RESUMEN

BACKGROUND: Anterior cruciate ligament (ACL) graft failure is influenced by factors such as meniscal tears and tibial plateau slope. Combined anterior cruciate ligament (ACL) and anterolateral ligament (ALL) reconstruction has reduced failure rates; however, its efficacy in high-risk patients remains unclear. This study hypothesized that combined ACL and ALL reconstruction would yield similar clinical outcomes in patients with varying risks of ACL failure. PATIENTS AND METHODS: A total of 76 patients who underwent primary single-bundle ACL reconstruction combined with ALL reconstruction between June 2018 and June 2021 were included. The medial tibial slope (MTS), lateral tibial slope (LTS), and anterior tibial translation (ATT) were measured using magnetic resonance imaging and plain radiography of the knee joint. The meniscal lesions were assessed during surgery. Preoperative clinical assessments and final follow-up were conducted using patient-reported outcome measurements (PROMs), including the International Knee Documentation Committee (IKDC) evaluation, Lysholm knee scoring scale, and Tegner Activity scale. PROMs were collected at least two years postoperatively. RESULTS: The average follow-up was 32.5 ± 7.4 months. There were no significant differences in postoperative IKDC score, Lysholm score, or Tegner activity score between patients with or without medial meniscus injury (p = 0.155, 0.914, and 0.042, respectively), with or without lateral meniscus injury (p = 0.737, 0.569, and 0.942, respectively), medial tibial slope > 12° or ≤ 12° (p = 0.290, 0.496, and 0.988, respectively), or lateral tibial slope > 7.4° or ≤ 7.4° (p = 0.213, 0.625, and 0.922, respectively). No significant correlations were found between anterior tibial translation and postoperative IKDC (R = -0.058, p = 0.365), Lysholm (R = -0.017, p = 0.459), or Tegner activity scores (R = -0.147, p = 0.189). CONCLUSION: Our study demonstrates that single-bundle ACL reconstruction combined with ALL reconstruction provides reliable and comparable clinical outcomes in patients with high-risk factors for ACL graft failure, such as increased tibial slope or meniscal injury. Our results suggest that the indications for ALL reconstruction may be expanded to include patients with a high tibial slope or meniscal injury, because these factors have been shown to contribute to increased rotational instability and high rates of ACL graft failure. Future prospective randomized controlled trials with large patient cohorts and long follow-up periods are needed to validate these findings and establish clear guidelines for patient selection and surgical decision-making. LEVEL OF EVIDENCE: Level 3.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Humanos , Reconstrucción del Ligamento Cruzado Anterior/métodos , Reconstrucción del Ligamento Cruzado Anterior/efectos adversos , Femenino , Masculino , Adulto , Lesiones del Ligamento Cruzado Anterior/cirugía , Factores de Riesgo , Adulto Joven , Estudios Retrospectivos , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Medición de Resultados Informados por el Paciente , Lesiones de Menisco Tibial/cirugía , Lesiones de Menisco Tibial/diagnóstico por imagen , Ligamento Cruzado Anterior/cirugía , Ligamento Cruzado Anterior/diagnóstico por imagen , Adolescente , Insuficiencia del Tratamiento , Estudios de Seguimiento , Tibia/cirugía , Tibia/diagnóstico por imagen , Persona de Mediana Edad , Imagen por Resonancia Magnética
18.
J Orthop Surg (Hong Kong) ; 32(2): 10225536241273925, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39115882

RESUMEN

PURPOSE: This study aims to compare the mid-term radiographic, clinical results and survivorship between distal tibial tuberosity high tibial osteotomy (DTT-HTO) and conventional biplanar medial open-wedge high tibial osteotomy (cOW-HTO). METHODS: The weight-bearing line ratio (WBL%) and medial proximal tibial angle (MPTA) were evaluated using a standing anteroposterior view of lower extremity. The posterior tibial slope (PTS), Caton-Deschamps index (CDI), tilting angle (TT) and lateral shift ratio (LSR) were evaluated using the lateral views and Merchant views. The Knee Society (KS) knee and function score, Lysholm score, and Anterior Knee Pain Scale (Kujala score) were were used to evaluate the functional outcomes. All parameters were evaluated preoperatively and at the final follow-up. The postoperative complications and survivorship for both groups were also evaluated during the follow-up period. RESULTS: The WBL% and MPTA exhibited no significant differences between the two groups preoperatively and at the final follow-up. The postoperative CDI and TT in the cOW group decreased significantly compared with the DTT group (p = .037 and .041, respectively). The PF grade showed a significant increase after DTT-HTO and cOW-HTO (p = .036 and <0.001, respectively). Furthermore, the postoperative PF grade of cOW group was significantly higher than that of DTT group (p = .039). The KS knee and function score, Lysholm score, and Kujala score for both groups improved similarly at the final follow-up. The survivorship free of revision was 92.7 % in the DTT group and 94.2% in the OW group. CONCLUSIONS: Despite observing a lower risk of PF joint progression in DTT-HTO compared to cOW-HTO, the clinical outcomes and survivorship after DTT-HTO and cOWHTO were comparable over a mid-term follow-up.


Asunto(s)
Osteotomía , Tibia , Humanos , Osteotomía/métodos , Tibia/cirugía , Tibia/diagnóstico por imagen , Masculino , Femenino , Adulto , Persona de Mediana Edad , Estudios de Seguimiento , Articulación Patelofemoral/cirugía , Articulación Patelofemoral/diagnóstico por imagen , Estudios Retrospectivos , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/diagnóstico por imagen , Complicaciones Posoperatorias/epidemiología
19.
Eur J Orthop Surg Traumatol ; 34(6): 3233-3240, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39096419

RESUMEN

BACKGROUND: The use of a tibial stem for large deformities (> 10°) would reduce the incidence of pain. The aim of this study was to compare the effect of tibial stem on postoperative pain and aseptic loosening at the tibia in patients with a preoperative deformity > 10° in the frontal plane at 2 years follow-up. METHODS: This was a retrospective single-center case-control study. Ninety-eight patients with deformities greater than 10° in the frontal plane and a BMI > 30 kg/m2 who had undergone posterior-stabilized (PS) total knee arthroplasty (TKA) with a tibial stem were matched using a propensity score to 98 patients who had undergone PS TKA without a tibial stem. The primary endpoint was the pain rate at 2 years. The secondary endpoints were the rate of aseptic loosening of the tibia at 2 years post-operatively. RESULTS: A significant difference was found in the rate of postoperative pain at 2 years. It was higher in the group without tibial stem compared with the group with tibial stem (41.8% vs 17.3%, p = 0.0003). In the group without tibial stem, 24.4% of pain was mild, 61% moderate and no severe pain. In the tibial stem group, 47.1% of pain was mild, 41.2% moderate and no severe pain. A radiolucent line (RLL) was present at 2 years in 26.5% of prostheses in the without tibial stem group and in 9.2% of prostheses in the tibial stem group (p = 0.002). There was no difference between the two groups in terms of aseptic loosening. CONCLUSION: The use of a tibial stem in primary TKA in patients with frontal deformities greater than 10° reduces postoperative pain and the presence of radiolucent lines.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Dolor Postoperatorio , Falla de Prótesis , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Dolor Postoperatorio/etiología , Dolor Postoperatorio/prevención & control , Femenino , Masculino , Estudios Retrospectivos , Anciano , Estudios de Casos y Controles , Persona de Mediana Edad , Prótesis de la Rodilla/efectos adversos , Tibia/cirugía , Diseño de Prótesis , Osteoartritis de la Rodilla/cirugía
20.
J Orthop Surg Res ; 19(1): 482, 2024 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-39152500

RESUMEN

BACKGROUND: The adoption of robot-assisted total knee arthroplasty (TKA) aims to enhance the precision of implant positioning and limb alignment. Despite its benefits, the adoption of such technology is often accompanied by an initial learning curve, which may result in increased operative times. This study sought to determine the learning curve for the ROSA (Robotic Surgical Assistant) Knee System (Zimmer Biomet) in performing TKA and to evaluate the accuracy of the system in executing bone cuts and angles as planned. The hypothesis of this study was that cumulative experience with this robotic system would lead to reduced operative times. Additionally, the ROSA system demonstrated reliability in terms of the accuracy and reproducibility of bone cuts. METHODS: In this retrospective observational study, we examined 110 medical records from 95 patients who underwent ROSA-assisted TKA performed by three surgeons. We employed the cumulative summation methodology to assess the learning curves related to operative time. Furthermore, we evaluated the accuracy of the ROSA Knee System in performing TKA by comparing planned versus validated values for femoral and tibial bone cuts and angles. RESULTS: The learning curve for the ROSA Knee System spanned 14, 14, and 6 cases for the respective surgeons, with operative times decreasing by 22 min upon reaching proficiency (70.8 vs. 48.9 min; p < 0.001). Significant discrepancies were observed between the average planned and validated cuts and angles for femoral bone cuts (0.4 degree ± 2.4 for femoral flexion, 0.1 degree ± 0.6 for femoral coronal alignment, 0.3 mm ± 1.2 for distal medial femoral resection, 1.4 mm ± 8.8 for distal lateral femoral resection) and hip-knee-ankle axis alignment (0.3 degree ± 1.9 )(p < 0.05) but not for tibial bone cuts. Differences between planned and validated measurements during the learning and proficiency phases were nonsignificant across all parameters, except for the femoral flexion angle (0.42 degree ± 0.8 vs. 0.44 degree ± 2.7) (p = 0.49). CONCLUSION: The ROSA Knee System can be integrated into surgical workflows after a modest learning curve of 6 to 14 cases. The system demonstrated high accuracy and reproducibility, particularly for tibial bone cuts. Acknowledging the learning curve associated with new robot-assisted TKA technologies is vital for their effective implementation.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Curva de Aprendizaje , Procedimientos Quirúrgicos Robotizados , Tibia , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/educación , Artroplastia de Reemplazo de Rodilla/instrumentación , Procedimientos Quirúrgicos Robotizados/educación , Procedimientos Quirúrgicos Robotizados/métodos , Femenino , Masculino , Estudios Retrospectivos , Anciano , Tibia/cirugía , Persona de Mediana Edad , Tempo Operativo , Anciano de 80 o más Años , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA