Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 13.884
Filtrar
1.
J Clin Pediatr Dent ; 48(5): 102-109, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39275826

RESUMEN

Nickel-titanium (NiTi) instruments offer many advantages during endodontic instrumentation; however, the fracture risk within the canal remains a concern. Manufacturers continuously develop and introduce instruments to the market with supposedly enhanced cyclic fatigue resistance and increased flexibility, achieved through different proprietary manufacturing processes, the details of which have not been made public. In recent years, two rotary systems specially designed for deciduous teeth have been commercially available, but information about their performance is lacking. This investigation aimed to identify which manufacturing process provides better cyclic fatigue resistance: the AF-H Wire technology used in the AF baby rotary files (AF-f) or the CM-Wire technology used in the i3 Gold deciduous teeth rotary files (i3G-f). Forty rotary International Organization for Standardization (ISO) 25/04 files were tested in artificial canals with a standard geometry of 60° angle and 2.5 mm radius until fracture. The number of cycles to fracture was calculated, and the length of the fragments was measured. A scanning electron microscope (SEM) was used to examine the fracture surfaces and fragments. Energy dispersive spectroscopy (EDS) was used to determine the percentage weight of NiTi in each file. The statistical analysis (Mann-Whitney test) showed that the cyclic fatigue resistance of the AF-f was significantly higher (p < 0.0001) than that of the i3G-f. Additionally, there was a significant difference (p = 0.0419) in the length of the fractured fragments. All instruments showed one or more types of manufacturing defects and presented similar NiTi percentages by weight. The manufacturing process is critical to cyclic fatigue resistance, and there seems to be responsible for the difference in cyclic fatigue resistance between these similar instruments.


Asunto(s)
Falla de Equipo , Calor , Níquel , Preparación del Conducto Radicular , Titanio , Preparación del Conducto Radicular/instrumentación , Níquel/química , Humanos , Titanio/química , Diseño de Equipo , Ensayo de Materiales , Instrumentos Dentales , Microscopía Electrónica de Rastreo , Aleaciones Dentales/química , Técnicas In Vitro , Análisis del Estrés Dental
2.
Clin Oral Investig ; 28(10): 531, 2024 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-39298025

RESUMEN

AIM: To evaluate the influence of different levels of metal artifact reduction (MAR) tool and milliamperage (mA) on the diagnosis of fracture extension in endodontically treated teeth using cone beam CT (CBCT). MATERIALS AND METHODS: Ten maxillary premolars were endodontically treated and positioned in the empty sockets of a human maxilla covered with wax. CBCT acquisitions were performed using the Eagle Edge device (Dabi Atlante, Brazil) adjusted to 120 kVp, FOV of 4 × 6 cm, exposure time of 24 s and voxel size of 0.2 mm in 8 different conditions with different MAR (1, 2 and 3) and mA (3.2 and 6.3) levels. Crown-root fractures were simulated in the universal testing machine, and CBCT images were acquired again. Five radiologists evaluated the presence and extension of fractures with a 5-point scale. Statistical analysis was performed by analysis of variance, Tukey and Kappa test (α = 0.05). RESULTS: Although different mA levels did not significantly (p > 0.05) affect the diagnosis values for fracture presence and extension, when evaluated the different levels of MAR, AUC and sensitivity showed significantly higher values (p < 0.05) for MAR 0 using 6.3 mA and kappa agreement showed significantly higher values (p < 0.05) for MAR 0 and 2 using 6.3 mA. CONCLUSIONS: Although mA levels do not have a diagnostic effect when isolating the MAR level; in 6.3 mA, MAR 0 and 2 can positively influence the diagnosis of fracture extension in endodontically treated teeth using CBCT. CLINICAL RELEVANCE: The isolate evaluation of dental fracture presence can overlook diagnostics error of its extension.


Asunto(s)
Artefactos , Diente Premolar , Tomografía Computarizada de Haz Cónico , Fracturas de los Dientes , Diente no Vital , Humanos , Fracturas de los Dientes/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Diente no Vital/diagnóstico por imagen , Diente Premolar/diagnóstico por imagen , Diente Premolar/lesiones , Técnicas In Vitro , Metales , Maxilar/diagnóstico por imagen , Sensibilidad y Especificidad
3.
Clin Oral Investig ; 28(10): 550, 2024 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-39320486

RESUMEN

OBJECTIVE: To evaluate the efficacy and cytotoxicity of experimental 6% and 35% hydrogen peroxide gels (HP6 or HP35) incorporated with titanium dioxide nanoparticles (NP) co-doped with nitrogen and fluorine and irradiated with a violet LED light (LT). METHODS: Bovine enamel-dentin disks adapted to artificial pulp chambers were randomly assigned to bleaching (n = 8/group): NC (negative control), NP, HP6, HP6 + LT, HP6 + NP, HP6 + NP + LT, HP35, HP35 + LT, HP35 + NP, HP35 + NP + LT, and commercial HP35 (COM). Color (ΔE00) and whiteness index (ΔWID) changes were measured before and 14 days after bleaching. The extracts (culture medium + diffused gel components) collected after the first session were applied to odontoblast-like MDPC-23 cells, which were assessed concerning their viability, oxidative stress, and morphology. The amount of HP diffused through the disks was determined. Data were analyzed by generalized linear models or Kruskal Wallis Tests (α = 5%).  RESULTS: HP6 + NP + LT exhibited ΔE00 and ΔWID higher than HP6 (p < 0.05) and similar to all HP35 groups. HP6 + NP + LT showed the lowest HP diffusion, and the highest cell viability (%) among bleached groups, preserving cell morphology and number of living cells similar to NC and NP. HP6 + LT, HP6 + NP, and HP6 + NP + LT exhibited the lowest cell oxidative stress among bleached groups (p < 0.05). HP35, HP35 + LT, and HP35 (COM) displayed the lowest cell viability. CONCLUSION: HP6 achieved significantly higher color and whiteness index changes when incorporated with nanoparticles and light-irradiated and caused lower cytotoxicity than HP35 gels. The nanoparticles significantly increased cell viability and reduced the hydrogen peroxide diffusion and oxidative stress, regardless of HP concentration. CLINICAL SIGNIFICANCE: Incorporation of co-doped titanium dioxide nanoparticles combined with violet irradiation within the HP6 gel could promote a higher perceivable and acceptable efficacy than HP6 alone, potentially reaching the optimal esthetic outcomes rendered by HP35. This approach also holds the promise of reducing cytotoxic damages and, consequently, tooth sensitivity.


Asunto(s)
Supervivencia Celular , Geles , Peróxido de Hidrógeno , Nanopartículas , Titanio , Blanqueadores Dentales , Blanqueamiento de Dientes , Peróxido de Hidrógeno/farmacología , Peróxido de Hidrógeno/toxicidad , Blanqueamiento de Dientes/métodos , Titanio/química , Titanio/toxicidad , Animales , Bovinos , Blanqueadores Dentales/toxicidad , Blanqueadores Dentales/farmacología , Supervivencia Celular/efectos de los fármacos , Estrés Oxidativo/efectos de los fármacos , Técnicas In Vitro , Odontoblastos/efectos de los fármacos , Esmalte Dental/efectos de los fármacos , Distribución Aleatoria , Dentina/efectos de los fármacos
4.
Rev Lat Am Enfermagem ; 32: e4365, 2024.
Artículo en Inglés, Español, Portugués | MEDLINE | ID: mdl-39319894

RESUMEN

OBJECTIVE: to evaluate three methods of nasogastric tube fixation in terms of adhesion, displacement and skin integrity. METHOD: ex vivo study, with a sample of 30 experimental noses (10 for each type of fixation), developed with porcine skin, based on the average measurements of the human nose, in which 14-gauge polyvinyl chloride probes were inserted and 2 methods of fixation with adhesive tape (Fixation A and B) and one with an industrial device (Fixation C) were used. Each group was exposed to traction of 50, 100 and 500g sequentially over 12 and 24 hours, testing: adhesion capacity, probe displacement and skin integrity. The Chi-square test of independence was calculated for nominal variables and Student's t-tests and analysis of variance (p< 0.05) for rational variables. RESULTS: fixation B showed lower adhesion capacity (p <0.001) when compared to the other two fixations. A mean displacement of 52.17 mm was observed in the probes fixed by methods A and B and a greater occurrence of lesions associated with fixations A and C (p = 0.001). CONCLUSION: the results show complications related to the fixations: lack of adhesion, displacement of the probe and skin lesions, drawing attention to the complexity of the procedure.


Asunto(s)
Intubación Gastrointestinal , Piel , Porcinos , Intubación Gastrointestinal/métodos , Intubación Gastrointestinal/instrumentación , Animales , Adherencias Tisulares , Humanos , Técnicas In Vitro
5.
Clin Oral Investig ; 28(9): 482, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39128981

RESUMEN

OBJECTIVES: To analyze the differences in cusp height on radiographs, establishing proportional relationships between cusp and alveolar bone crest (ABC) measurements. The goal of this study was to develop a correction coefficient by considering this proportion. MATERIALS AND METHODS: Twenty-one artificial teeth, molars and premolars, and bovine ribs were used. Interproximal radiographs were taken with the aid of a positioner. The vertical angles used were: 0°, + 5°, and + 10°, and processed using three spatial resolutions measured in line pairs per mm (lp/mm): 20, 25 and 40. The Perio filter was applied to each image, in addition to the original one. Combinations of angle, resolution, and filter were made. Eighteen images were analyzed by three specialists, resulting in 252 measurements for each evaluator, totaling 756 measurements. RESULTS: The overall variability of the measurements can be explained mainly by the variation in tooth anatomy. The 0° 25 lp/mm Perio filter method was the closest one to the actual clinical scenario for both cusps and ABC. The correction factor managed to explain 71.45% of the errors. CONCLUSIONS: The variation in vertical angulation interferes with cusp and ABC measurements, and the angulation at 0º and spatial resolution of 25 lp/mm showed better results. The use of correction coefficients allowed approaching actual measurement values. CLINICAL RELEVANCE: More accurate ABC height measurements are essential even in radiographic exams that do not meet the standard of excellence because the need to repeat radiographic exams is then eliminated.


Asunto(s)
Proceso Alveolar , Proyectos Piloto , Animales , Proceso Alveolar/diagnóstico por imagen , Proceso Alveolar/anatomía & histología , Bovinos , Radiografía Dental , Costillas/diagnóstico por imagen , Costillas/anatomía & histología , Humanos , Técnicas In Vitro , Corona del Diente/diagnóstico por imagen , Corona del Diente/anatomía & histología
6.
Clin Oral Investig ; 28(9): 496, 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39177835

RESUMEN

OBJECTIVES: To evaluate the marginal integrity (MI%) and to characterize specific properties of a thermoviscous bulk-fill resin composite, two regular bulk-fill resin composites, and a non-bulk-fill resin composite. MATERIALS AND METHODS: VisCalor bulk (VBF), Filtek One Bulk Fill (OBF), and Aura Bulk Fill (ABF) were evaluated. Filtek Z250 XT (ZXT) was used as non-bulk-fill control. MI% was evaluated in standardized cylindrical cavities restored with the composites by using a 3D laser confocal microscope. The following properties were characterized: volumetric polymerization shrinkage (VS%), polymerization shrinkage stress (Pss), degree of conversion (DC%), microhardness (KHN), flexural strength (FS), and elastic modulus (EM). Data were analyzed by one-way and two-way ANOVA, and Tukey HSD post-hoc test (α = 0.05). RESULTS: VBF presented the highest MI% and the lowest VS% and Pss (p < 0.05). DC% ranged from 59.4% (OBF) to 71.0% (ZXT). ZXT and VBF presented similar and highest KHN than OBF and ABF (p < 0.05). ABF presented the lowest FS (p < 0.05). EM ranged from 5.5 GPa to 7.7 GPa, with the values of ZXT and VBF being similar and statistically higher than those of OBF and ABF (p < 0.05). CONCLUSIONS: Thermoviscous technology employed by VisCalor bulk was able to improve its mechanical behavior comparatively to regular bulk-fill resin composites and to contribute to a better marginal integrity in restorations built up in cylindrical cavities with similar geometry to a class I cavity as well. Although presenting overall better physicomechanical properties, Z250 XT presented the worst MI%. CLINICAL RELEVANCE: The marginal integrity, which is pivotal for the success of resin composite restorations, could be improved using VisCalor bulk-fill. The worst MI% presented by Z250 XT reinforces that non-bulk-fill resin composites shall not be bulk-inserted in the cavity to be restored.


Asunto(s)
Resinas Compuestas , Adaptación Marginal Dental , Módulo de Elasticidad , Resistencia Flexional , Ensayo de Materiales , Polimerizacion , Propiedades de Superficie , Resinas Compuestas/química , Dureza , Microscopía Confocal , Técnicas In Vitro , Restauración Dental Permanente/métodos , Análisis del Estrés Dental
7.
Oper Dent ; 49(5): 540-550, 2024 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-39135205

RESUMEN

PURPOSE: This study aimed to assess the impact of battery levels in single-peak and multi-peak light-curing units (LCUs) on irradiance, and their effects on glass fiber post push-out bond strength to root dentin and the degree of conversion of dual-cure universal resin cement. METHODS AND MATERIALS: Sixty bovine roots underwent endodontic treatment and were randomly distributed into 6 groups (n=10), formed by combining two LCUs (single-peak and multipeak) and three battery levels (100%, 50%, and 10%). A spectrophotometer measured irradiance (mW/ cm2) and spectral irradiance (mW/cm2/nm). Push-out bond strength (PBS) tests occurred at three root regions (cervical, middle, and apical), with optical and scanning electron microscopy for failure mode analysis. Degree of conversion (DC) was evaluated across the root regions. Data were analyzed using two-way repeated measures ANOVA and the Tukey HSD test. The Fisher exact test verified failure modes (α=0.05). RESULTS: As multipeak LCU battery levels decreased, emitted irradiance also diminished, with notable PBS reductions in the apical thirds. Failure modes were influenced by different conditions, primarily exhibiting mixed modes. Battery levels significantly impacted DC in the multipeak LCU, particularly in the cervical region, while the single-peak LCU exhibited DC reduction at the 10% battery level in the cervical region. CONCLUSIONS: Emitted irradiance, resin cement DC, and glass fiber post bond strength to root dentin may be influenced by varying cordless LCUs and battery levels.


Asunto(s)
Luces de Curación Dental , Vidrio , Técnica de Perno Muñón , Cementos de Resina , Cementos de Resina/química , Bovinos , Técnica de Perno Muñón/instrumentación , Animales , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Recubrimiento Dental Adhesivo/métodos , Análisis del Estrés Dental , Curación por Luz de Adhesivos Dentales/métodos , Técnicas In Vitro , Dentina
8.
Oper Dent ; 49(5): 564-573, 2024 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-39169512

RESUMEN

This study evaluated the mechanical properties of demineralized dentin matrix submitted to different bleaching treatments, as well as the changes in mass and collagen biodegradation brought about by endogenous protease. Dentin collagen matrices were prepared to receive the following treatments (n=12): no bleaching treatment (C-control), 10% carbamide peroxide (CP-Opalescence PF, Ultradent, South Jordan, UT, USA) 10%/8 hours/ day/14 days, and 40% hydrogen peroxide (HP-Opalescence Boost, Ultradent), 40 minutes per session/3 sessions. The dentin matrices were evaluated for elastic modulus and mass before and after treatments and ultimate tensile strength after treatments. The solution collected during storage was evaluated for hydroxyproline release. There was no statistically significant difference between CP and C in terms of the elastic modulus (p=0.3697) or mass variation (p=0.1333). Dentin beams treated with HP and C presented significant mass loss after the first session (p=0.0003). HP treatment led to complete degradation of collagen matrices after the second bleaching session. After the second session, CP showed higher hydroxyproline concentration than C (p<0.0001). Ultimate tensile strength was lower for CP than C (p=0.0097). CP did not affect the elastic modulus or the dentin collagen matrix mass but did promote hydroxyproline release by endogenous protease and reduce the ultimate tensile strength. HP significantly affected the mechanical properties of dentin and promoted complete degradation of the demineralized dentin collagen matrix.


Asunto(s)
Peróxido de Carbamida , Colágeno , Dentina , Módulo de Elasticidad , Peróxido de Hidrógeno , Resistencia a la Tracción , Blanqueadores Dentales , Blanqueamiento de Dientes , Dentina/metabolismo , Dentina/efectos de los fármacos , Colágeno/metabolismo , Humanos , Blanqueadores Dentales/farmacología , Peróxido de Carbamida/farmacología , Blanqueamiento de Dientes/métodos , Péptido Hidrolasas/metabolismo , Peróxidos , Urea/análogos & derivados , Urea/farmacología , Hidroxiprolina/metabolismo , Técnicas In Vitro
9.
Lasers Med Sci ; 39(1): 217, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39145805

RESUMEN

This in vitro study aimed to investigate potential changes in the color and roughness of dental enamel resulting from the use of different toothpaste formulations during bleaching with violet LED light (405 nm). Sixty specimens of bovine incisors, each measuring 6 × 6 × 3 mm, were segregated into six distinct experimental groups based on their respective treatments (n = 10): C + VL: Brushing with Colgate® Total 12 + bleaching with violet LED; LB + VL: Brushing with Colgate® Luminous White Brilliant + bleaching with violet LED; LI + VL: Brushing with Colgate® Luminous White Instant + violet LED bleaching; C: Brushing with Colgate® Total 12; LB: Brushing with Colgate® Luminous White Brilliant; LI: Brushing with Colgate® Luminous White Instant. The examined variables included alterations in color (∆L*, ∆a*, ∆b*, ∆Eab, and ∆E00), surface roughness (Ra), and scanning electron microscopy observations. No statistically significant distinctions emerged in total color variations (∆E00 and ∆E) among the groups under scrutiny. Notably, the groups that employed Colgate® Luminous White Instant displayed elevated roughness values, irrespective of their association with violet LED, as corroborated by scanning electron microscopy examinations. It can be concluded that whitening toothpastes associated to violet LED do not influence the color change of dental enamel in fifteen days of treatment. Toothpastes with a higher number of abrasive particles showed greater changes in enamel roughness, regardless of the use of violet LED.


Asunto(s)
Color , Esmalte Dental , Propiedades de Superficie , Blanqueadores Dentales , Blanqueamiento de Dientes , Pastas de Dientes , Esmalte Dental/efectos de los fármacos , Esmalte Dental/efectos de la radiación , Bovinos , Animales , Pastas de Dientes/química , Blanqueamiento de Dientes/métodos , Blanqueamiento de Dientes/efectos adversos , Propiedades de Superficie/efectos de los fármacos , Blanqueadores Dentales/efectos adversos , Técnicas In Vitro , Microscopía Electrónica de Rastreo
10.
J Clin Pediatr Dent ; 48(4): 160-167, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39087226

RESUMEN

Glass ionomer cements (GICs) are the common materials employed in pediatric dentistry because of their specific applications in class I restorations and atraumatic restoration treatments (ART) of deciduous teeth in populations at high risk of caries. Studies show a limited clinical durability of these materials. Attempts have thus been made to incorporate nanoparticles (NPs) into the glass ionomer for improving resistance and make it like the tooth structure. An in vitro experimental study was conducted using the required samples dimensions and prepared based on the test being carried out on the three groups with or without the modification of light-cured glass ionomer. Samples were grouped as follows: control group (G1_C), 2% silver phosphate/hydroxyapatite NPs group (G2_SPH), and 2% titanium dioxide NPs group (G3_TiO2). The physical tests regarding flexural strength (n = 10 per group), solubility (n = 10 per group), and radiopacity (n = 3 per group) were performed. The data were analyzed by Shapiro Wilks test, and one-way analysis of variance (one-way ANOVA), and multiple comparisons by post hoc Tukey's test. The p-value of < 0.05 was considered significant. No statistically significant difference was observed between the control group (G1_C) and (G2_SPH) (p = 0.704) in the flexural strength test, however differences were found between G2_SPH and G3_TiO2 groups, ANOVA (p = 0.006); post hoc Tukey's test (p = 0.014). Pertaining to the solubility, G2_SPH obtained the lowest among the three groups, ANOVA (p = 0.010); post hoc Tukey's test (p = 0.009). The three study groups obtained an adequate radiopacity of >1 mm Al, respectively. The resin-modified glass ionomer cement (RMGIC) was further modified with 2% silver phosphate/hydroxyapatite NPs to improve the physical properties such as enhancing the solubility and sorption without compromising the flexural strength and radiopacity behavior of modified RMGIC. The incorporation of 2% titanium dioxide NPs did not improve the properties studied.


Asunto(s)
Durapatita , Cementos de Ionómero Vítreo , Nanopartículas , Fosfatos , Titanio , Titanio/química , Cementos de Ionómero Vítreo/química , Durapatita/química , Nanopartículas/química , Fosfatos/química , Técnicas In Vitro , Ensayo de Materiales , Humanos , Compuestos de Plata/química , Solubilidad , Resistencia Flexional
11.
J Bras Nefrol ; 46(3): e20240004, 2024.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-39132943

RESUMEN

Experimental medicine has formed the basis for generating medical knowledge for several centuries. The development of various experimental tools introduced at different times in medical practice has allowed the acquisition of knowledge with increasingly sophisticated scientific bases. Consequently, through in vivo, in vitro and, more recently, in silico experiments, we have witnessed an uninterrupted collection of experimental data potentially valuable for medicine, especially for Nephrology. We are gradually contemplating the uniqueness of individuals for the benefit of life and human dignity.


Asunto(s)
Simulación por Computador , Nefrología , Humanos , Investigación Biomédica , Técnicas In Vitro , Animales
12.
Clin Oral Investig ; 28(8): 465, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39098966

RESUMEN

OBJECTIVE: To evaluate the effect of four different photoactivation protocols (according to "photoactivated faces" - mesial/distal, cervical/incisal or center - and "photoactivation time" - 6-3 s) of a high-power photo activator (Valo Cordless®-Ultradent) on the shear bond strength (SBS) between metal brackets and dental enamel and on the degree of conversion (DC) of an orthodontic resin. MATERIALS AND METHODS: 40 bovine incisor crowns were randomly assigned to 4 groups (n = 10). The brackets were bonded with Transbond XT® resin using 4 protocols according to the "photoactivation protocol" factor (which was subdivided into photoactivated faces and photoactivation time): V3C = 3 s + center; V6C = 6 s + center; V3M3D = 3 s on mesial + 3 s on distal; V3C3I = 3 s on cervical + 3 s on incisal. All the samples were stored for 4 months (water,37ºC) and then subjected to a SBS test (100KgF,1 mm/min). 40 resin discs were made to evaluate the monomer degree of conversion. Data from the SBS and DC were assessed by One-way ANOVA and Tukey's test (5%). Bond failures were analyzed according to the Adhesive Remnant Index (ARI) and evaluated by the Kruskal-Wallis test (5%). RESULTS: There was a statistically significant difference (p = 0.008) in the One-way ANOVA result for SBS values between all groups, but the protocols showed statistically similar results (p ≥ 0.05-Tukey's tests) concerning the photoactivated faces (V6C, V3M3D and V3C3I) and photoactivation time (V3C and V6C) factors individually. There was no statistically significant difference (p ≥ 0.05) in the One-way ANOVA result for DC values. CONCLUSION: The SBS and DC values will vary depending on the protocol applied. CLINICAL RELEVANCE: It is possible to maintain the bracket fixation quality with the use of a high-power LED photo activator associated with a shorter photoactivation time. However, it is assumed that not all types of protocols that might be applied will provide quality bonding, such as V3C, V3M3D and V3C3I, which may - depending on the SBS and DC values - affect the final treatment time, due to brackets debonding, or increase of possibility of damage to dental enamel during bracket removal. Clinical studies are suggested to confirm the hypotheses of this research.


Asunto(s)
Recubrimiento Dental Adhesivo , Esmalte Dental , Análisis del Estrés Dental , Ensayo de Materiales , Soportes Ortodóncicos , Distribución Aleatoria , Cementos de Resina , Resistencia al Corte , Animales , Bovinos , Recubrimiento Dental Adhesivo/métodos , Cementos de Resina/química , Esmalte Dental/química , Propiedades de Superficie , Técnicas In Vitro , Factores de Tiempo , Corona del Diente , Polimerizacion
13.
Dent Mater ; 40(10): 1584-1590, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39068089

RESUMEN

OBJECTIVES: To evaluate the effects of dentin biomodification agents (Proanthocyanidin (PAC), Cardol (CD) and Cardol-methacrylate (CDMA) on dentin hydrophilicity by contact angle measurement, viability of dental pulp stem cells (DPSCs) and nanomechanical properties of the hybrid layer (HL). METHODS: CDMA monomer was synthesized from cardol through methacrylic acid esterification. Human extracted third molars were used for all experiments. For nanomechanical tests, specimens were divided in four groups according to the primer solutions (CD, CDMA, PAC and control) were applied before adhesive and composite coating. Nanomechanical properties of the HL were analyzed by nanoindentation test using a Berkovich probe in a nanoindenter. Wettability test was performed on dentin surfaces after 1 min biomodification and measured by contact angle analysis. Cytotoxicity was assessed by a MTT assay with DPSCs after 48 and 72 h. Data were analyzed with Student's t test or Two-way ANOVA and Tukey HSD test (p < 0.05). RESULTS: CD and CDMA solutions achieved greater hydrophobicity and increased the water-surface contact angles when compared to PAC and control groups (p < 0.05). PAC group showed a greater reduction of elastic modulus in nanoindentation experiments when compared to CD and CDMA groups (p < 0.05) after 4 months of aging. CD inhibited cell proliferation compared to all further materials (p < 0.05), whilst CDMA and PAC indicated no cell cytotoxicity to human DPSCs. SIGNIFICANCE: Cardol-methacrylate provided significantly higher hydrophobicity to dentin and demonstrated remarkable potential as collagen crosslinking, attaining the lowest decrease of HL's mechanical properties. Furthermore, such monomer did not affect pulp cytotoxicity, thereby highlighting promising feasibility for clinical applications.


Asunto(s)
Supervivencia Celular , Dentina , Metacrilatos , Humectabilidad , Humanos , Supervivencia Celular/efectos de los fármacos , Metacrilatos/química , Metacrilatos/farmacología , Dentina/química , Proantocianidinas/farmacología , Proantocianidinas/química , Ensayo de Materiales , Pulpa Dental/citología , Tercer Molar , Células Madre/efectos de los fármacos , Propiedades de Superficie , Interacciones Hidrofóbicas e Hidrofílicas , Técnicas In Vitro
14.
Eur J Prosthodont Restor Dent ; 32(3): 326-334, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39038187

RESUMEN

OBJECTIVES: This in vitro study focused on verifying the influence of different ambient light conditions on the accuracy and precision of models obtained from digital scans. METHODOLOGY: To measure the tested illuminances: chair light/reflector; room light, and natural light at the time of scanning, a luxmeter was used. From the STL file, nine experimental groups were formed. RESULTS: Of the nine specific combinations between the three IOS and the three types of lighting, it was verified that for all of them, as well as the ICC, the accuracy was also excellent, in which the measured values were not significantly influenced by the IOS brand (p = 0.994) nor by the type of lighting (p = 0.996). For precision data, GLM indicated a statistically significant interaction between IOS and lighting type. Under LS, accuracy was significantly higher with 3Shape® than with CS 3600 CareStream®, which had significantly higher accuracy than Virtuo Vivo™ Straumann®. CONCLUSIONS: The models obtained with the three IOS evaluated exhibited excellent accuracy under the different illuminance tested and the 3Shape® under the three illuminance conditions was the device that presented the best precision, specifically when using LC and LS.


Asunto(s)
Iluminación , Humanos , Técnicas In Vitro , Modelos Dentales , Luz , Reproducibilidad de los Resultados
15.
J Prosthet Dent ; 132(3): 603.e1-603.e8, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39019725

RESUMEN

STATEMENT OF PROBLEM: The optimal disinfection protocol that controls adverse effects and promotes effective antimicrobial action on removable prostheses is unclear. PURPOSE: This in vitro study investigated the effect of disinfectant solutions on the biological, physical, mechanical, and chemical properties of removable prosthesis materials. MATERIAL AND METHODS: Specimens of polymethyl methacrylate (PMMA) and cobalt chromium (Co-Cr) alloy were immersed in distilled water (PMMA) or artificial saliva (Co-Cr) as the control and in 0.25% sodium hypochlorite (NaOCl0.25%), 0.5% chloramine T (CT0.5%), and 0.15% Triclosan (TR0.15%). The antibiofilm activity was evaluated by microbial load and cell metabolisms of the mixed biofilm. Physical (color change, sorption, solubility, and surface roughness), mechanical (hardness, flexural, and impact strength), and chemical (corrosion) properties were analyzed before and after simulating a 5-year immersion. Laser confocal microscopy, scanning electron microscopy (SEM), and dispersive energy spectroscopy (EDS) complemented the analyses. The data were analyzed by using the Mann-Whitney U test, Kruskal-Wallis with Dunn posttests, 1-way ANOVA, and repeated measures ANOVA (α=.05). RESULTS: All solutions were effective against bacteria, but only NaOCl0.25% eliminated Candida spp. TR0.15%, and CT0.5% increased cell metabolisms. For interaction (time and solution), there was a reduction in PMMA hardness in the control and TR0.15%. Color, sorption, solubility, and flexural strength did not change. CT0.5% and TR0.15% were similar for impact resistance. CT0.5% caused the lowest roughness. NaOCl0.25% showed the greatest corrosive potential. Dark spots were seen under SEM in Co-Cr stored with NaOCl0.25% and TR0.15%. EDS indicated different proportions of oxygen, cobalt, chromium, and molybdenum. CONCLUSIONS: NaOCl0.25% had the best antimicrobial action. CT0.5% and TR0.15% have potential. Hardness and roughness changes were clinically acceptable, and the other properties remained unchanged. All the solutions caused color changes. NaOCl0.25% was unsatisfactory for use with Co-Cr, CT0.5% was intermediate, and TR0.15% was suitable.


Asunto(s)
Biopelículas , Aleaciones de Cromo , Polimetil Metacrilato , Propiedades de Superficie , Polimetil Metacrilato/química , Biopelículas/efectos de los fármacos , Aleaciones de Cromo/química , Corrosión , Ensayo de Materiales , Hipoclorito de Sodio/farmacología , Microscopía Electrónica de Rastreo , Dureza , Técnicas In Vitro , Desinfectantes/farmacología , Humanos , Resistencia Flexional
16.
Lasers Med Sci ; 39(1): 184, 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39020076

RESUMEN

PURPOSE: This study aimed to investigate the efficiency of antimicrobial photodynamic therapy (aPDT) on Streptococcus mutans biofilm in the oral cavity using the photosensitizer chloroaluminum phthalocyanine encapsulated in chitosan nanoparticles (ClAlPc/Ch) at three preirradiation times. METHODS: Biofilms of Streptococcus mutans strains (ATCC 25,175) were cultivated on bovine tooth blocks and exposed to a 10% sucrose solution three times a day for 1 min over three consecutive days. The samples were randomly distributed into five treatment groups (n = 5): (I) aPDT with ClAlPc/Ch with a preirradiation time of 5 min (F5), (II) aPDT with ClAlPc/Ch with a preirradiation time of 15 min (F15), (III) aPDT with ClAlPc/Ch with a preirradiation time of 30 min (F30), (IV) 0.12% chlorhexidine digluconate (CHX), and (V) 0.9% saline solution (NaCl). After treatment, the S. mutans biofilms formed on each specimen were collected to determine the number of viable bacteria (colony-forming units (CFU)/mL). Data were analyzed for normality using the Shapiro-Wilk test and the analysis of variance (ANOVA) and Tukey HSD tests to analyze the number of viable bacteria (α = 0.05). RESULTS: The one-way ANOVA showed a difference between the groups (p = 0.0003), and the Tukey HSD posttest showed that CHX had the highest microbial reduction of S. mutans, not statistically different from the F5 and F15 groups, whereas the NaCl group had the lowest microbial reduction statistically similar to the F30 group. CONCLUSION: The results demonstrate that aPDT mediated by ClAlPc/Ch when used at preirradiation times of 5-15 min can be an effective approach in controlling cariogenic biofilm of S. mutans, being an alternative to 0.12% CHX.


Asunto(s)
Biopelículas , Quitosano , Nanopartículas , Fotoquimioterapia , Fármacos Fotosensibilizantes , Streptococcus mutans , Streptococcus mutans/efectos de los fármacos , Streptococcus mutans/efectos de la radiación , Streptococcus mutans/fisiología , Fotoquimioterapia/métodos , Quitosano/farmacología , Quitosano/química , Nanopartículas/química , Biopelículas/efectos de los fármacos , Biopelículas/efectos de la radiación , Animales , Bovinos , Fármacos Fotosensibilizantes/farmacología , Técnicas In Vitro , Indoles/farmacología , Boca/microbiología , Clorhexidina/farmacología , Clorhexidina/análogos & derivados , Viabilidad Microbiana/efectos de los fármacos , Viabilidad Microbiana/efectos de la radiación , Compuestos Organometálicos
17.
Braz Dent J ; 35: 5858, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39045991

RESUMEN

ER:YAG laser and experimental resin-based dental adhesive loaded with functionalized carbonated apatite filler were used in this study to evaluate the dentin interaction in terms of penetration and occlusion of the dentinal tubules aiding in the control of dentin hypersensitivity (DH). Spheroidal Carbonated apatite nanoparticles (N-CAP), with an average size of 20±5 nm diameter, were synthesized, characterized, and incorporated in a universal adhesive "All Bond Universal, Bisco, USA", in (2% weight) concentration. Er:YAG laser "Lightwalker, FOTONA, EU" was adjusted to an energy output of 40mJ/ pulse and pulse repetition of 10 Hz for 10 seconds. Dentin specimens were prepared from the buccal surface of 75 extracted sound human molars. The specimens were randomly divided into five groups (n=15) according to the surface treatment: Group (L): Laser only; Group (LB): Laser in combination with adhesive; Group (LBN): Laser in combination with adhesive loaded with N-CAP; Group (B): adhesive only; and Group (BN): adhesive loaded with N-CAP. Depth of penetration and occlusion of the dentinal tubules were assessed using Environmental Scanning Electron Microscope Examination (ESEM). One-way ANOVA was used to compare groups, followed by a pairwise test for multiple comparisons (α=0.05). Groups (LB), and (LBN) showed the highest mean of dentinal tubules' penetration, with a non-significant difference between them. In contrast, the specimens treated with laser only (L) showed the most minor penetration. The employment of ER-YAG laser irradiation with the adhesive loaded with N-CAP was evaluated to be effective in penetrating and occluding the opened dentinal tubules.


Asunto(s)
Láseres de Estado Sólido , Láseres de Estado Sólido/uso terapéutico , Humanos , Apatitas/química , Dentina , Microscopía Electrónica de Rastreo , Nanopartículas/química , Sensibilidad de la Dentina , Técnicas In Vitro , Cementos Dentales/química
18.
Braz Dent J ; 35: 5773, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39045987

RESUMEN

Cleaning and shaping the root canal system are essential steps for performing successful endodontic therapy, and are challenging procedures in the apical region. This study aimed to conduct an ex vivo assessment of the debridement ability of the WaveOne Gold (Medium 35/.06) and TruNatomy (Medium 36/.03) systems in the apical third of round root canals of mandibular premolars. Forty-eight teeth, extracted for orthodontic or periodontal reasons, were divided into three groups (n=16), as follows: Group C, control (without instrumentation or irrigation); Group WOG, instrumentation with WaveOne Gold; Group TN, instrumentation with TruNatomy. A total of 40 mL of 2.5% sodium hypochlorite and 5 mL of 17% ethylenediamine tetraacetic acid were used per root canal in all the groups. Ten 0.5-µm serial cross-sections per specimen were obtained every 0.2 mm from a 2-mm segment of the apical region, extending from 1 to 3 mm short of the root apex. The sections were stained with hematoxylin-eosin and analyzed under a digital microscope (100x). The percentages of unprepared walls and remaining debris were quantified using ImageJ software. Generalized linear models were used to analyze the results (α=5%). Groups WOG and TN had significantly lower percentages of unprepared walls and remaining debris than Group C (p<0.05). There was no significant difference between groups WOG and TN for either of the variables studied (p>0.05). Instrumentation with the WaveOne Gold Medium and TruNatomy Medium instruments was associated with equivalent percentages of unprepared walls and remaining debris in the apical third of round canals of mandibular premolars.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Humanos , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos , Diente Premolar , Hipoclorito de Sodio/uso terapéutico , Ápice del Diente , Desbridamiento/métodos , Irrigantes del Conducto Radicular , Técnicas In Vitro
19.
Oper Dent ; 49(4): 455-464, 2024 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-38978307

RESUMEN

OBJECTIVE: To evaluate the effect of polyethylene fiber-reinforcement on the fracture resistance and fracture mode of extensive resin-based composite (RBC) restorations in structurally compromised maxillary premolars. METHODS AND MATERIALS: Maxillary premolars (54) with specific dimensions and extracted for orthodontic reasons were used. Following mesio-occluso-distal (MOD) cavity preparation and endodontic access, teeth were randomly assigned to one of three restorative protocols (n=18): RBC applied incrementally (I) or reinforced with woven polyethylene fibers (Ribbond) placed horizontally (H) or U-shaped (U). Restored teeth were stored for 45 days in distilled water at 37°C and then loaded monotonically until fracture. Half of the specimens in each group received axial loading (A) and the other half was loaded paraxially (PA). Fracture load data was assessed using two-way analysis of variance and Tukey's post hoc test for multiple comparisons (α=0.05). The fracture initiation and propagation path were analyzed using stereomicroscopy and scanning-electron microscopy. RESULTS: No significant differences were observed for the fracture strength among loading configurations, except for groups IA (825 N) and HA (553 N). Fracture initiated and propagated mainly at and through the RBC restoration in the I group, whereas a shift to the interface was observed in both polyethylene fiber-reinforced groups. Blocking and bridging of cracks were identified around the fibers, especially in specimens of group U. CONCLUSIONS: Incorporation of woven polyethylene fibers to reinforce extensive MOD resin-based composite restorations on endodontically treated premolars reduced the occurrence of cohesive fractures in the restorative material but was unable to increase the fracture resistance of the affected teeth.


Asunto(s)
Diente Premolar , Resinas Compuestas , Fracaso de la Restauración Dental , Restauración Dental Permanente , Análisis del Estrés Dental , Humanos , Resinas Compuestas/uso terapéutico , Resinas Compuestas/química , Técnicas In Vitro , Restauración Dental Permanente/métodos , Polietileno/química , Polietileno/uso terapéutico , Microscopía Electrónica de Rastreo , Ensayo de Materiales , Fracturas de los Dientes/prevención & control , Diente no Vital/terapia , Polietilenos
20.
Int Endod J ; 57(11): 1689-1698, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38984709

RESUMEN

AIM: To compare the effects of Cervical Access Cavity (CervAC) and Traditional Access Cavity (TradAC) on root canal preparation, root canal filling, and fracture resistance in mandibular incisors. METHODOLOGY: Twenty recently extracted and intact mandibular incisors were initially scanned using a micro-CT device. The specimens were anatomically matched to create two groups (n = 10). A wedge-shaped non-carious cervical lesion (NCCL) was created on the buccal aspect of all teeth using a double-faced segmented diamond disc. In group 1, a TradAC was prepared, whilst in group 2, access was created through the simulated NCCL using a round diamond bur 1012. After root canal preparation with Rotate instruments sizes 15/0.04, 20/0.04, and 25/0.04, the teeth were scanned again and evaluated for root canal volume and surface area, static voxels, volume of removed dental tissue, and dentine thickness. After that, the root canals were filled using the single-cone technique, teeth were restored with composite resin, and subsequently rescanned to calculate the volume of filling materials and voids. Then, the restored teeth were subjected to fracture resistance tests using a universal testing machine. Statistical comparisons between groups were performed with the Mann-Whitney test or the Student's t-test, with a statistical significance level of 5%. RESULTS: Statistical comparisons indicated no significant differences between groups in terms of root canal volume, surface area, static voxels, removed root dentine, root canal filling volume, percentage of voids, or fracture resistance load (p > .05). Conversely, teeth prepared with TradAC showed a significantly higher percentage of dental tissue removed from the crown (p = .001) and a greater volume of filling material remnants in the pulp chamber (p < .001) compared to the CervAC group. A significantly lower percentage reduction in dentine thickness was observed only on the mesial aspect of root at Level 1 in TradAC group (p = .008). CONCLUSIONS: CervAC can be considered a viable alternative approach in the presence of NCCL in mandibular incisors.


Asunto(s)
Incisivo , Mandíbula , Obturación del Conducto Radicular , Preparación del Conducto Radicular , Fracturas de los Dientes , Humanos , Obturación del Conducto Radicular/métodos , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos , Microtomografía por Rayos X , Cuello del Diente/patología , Cavidad Pulpar , Técnicas In Vitro
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA