Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.120
Filtrar
1.
Europace ; 26(9)2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39230049

RESUMEN

AIMS: Atrial fibrosis and autonomic remodelling are proposed pathophysiological mechanisms in atrial fibrillation (AF). Their impact on conduction velocity (CV) dynamics and wavefront propagation was evaluated. METHODS AND RESULTS: Local activation times (LATs), voltage, and geometry data were obtained from patients undergoing ablation for persistent AF. LATs were obtained at three pacing intervals (PIs) in sinus rhythm (SR). LATs were used to determine CV dynamics and their relationship to local voltage amplitude. The impact of autonomic modulation- pharmacologically and with ganglionated plexi (GP) stimulation, on CV dynamics, wavefront propagation, and pivot points (change in wavefront propagation of ≥90°) was determined in SR. Fifty-four patients were included. Voltage impacted CV dynamics whereby at non-low voltage zones (LVZs) (≥0.5 mV) the CV restitution curves are steeper [0.03 ± 0.03 m/s ΔCV PI 600-400 ms (PI1), 0.54 ± 0.09 m/s ΔCV PI 400-250 ms (PI2)], broader at LVZ (0.2-0.49 mV) (0.17 ± 0.09 m/s ΔCV PI1, 0.25 ± 0.11 m/s ΔCV PI2), and flat at very LVZ (<0.2 mV) (0.03 ± 0.01 m/s ΔCV PI1, 0.04 ± 0.02 m/s ΔCV PI2). Atropine did not change CV dynamics, while isoprenaline and GP stimulation resulted in greater CV slowing with rate. Isoprenaline (2.7 ± 1.1 increase/patient) and GP stimulation (2.8 ± 1.3 increase/patient) promoted CV heterogeneity, i.e. rate-dependent CV (RDCV) slowing sites. Most pivot points co-located to RDCV slowing sites (80.2%). Isoprenaline (1.3 ± 1.1 pivot increase/patient) and GP stimulation (1.5 ± 1.1 increase/patient) also enhanced the number of pivot points identified. CONCLUSION: Atrial CV dynamics is affected by fibrosis burden and influenced by autonomic modulation which enhances CV heterogeneity and distribution of pivot points. This study provides further insight into the impact of autonomic remodelling in AF.


Asunto(s)
Fibrilación Atrial , Fibrosis , Atrios Cardíacos , Humanos , Femenino , Masculino , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Persona de Mediana Edad , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/inervación , Anciano , Potenciales de Acción , Ablación por Catéter , Remodelación Atrial , Frecuencia Cardíaca , Técnicas Electrofisiológicas Cardíacas , Sistema Nervioso Autónomo/fisiopatología , Función del Atrio Izquierdo , Isoproterenol/farmacología , Atropina/farmacología , Factores de Tiempo , Sistema de Conducción Cardíaco/fisiopatología , Resultado del Tratamiento
2.
BMC Cardiovasc Disord ; 24(1): 421, 2024 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-39134935

RESUMEN

BACKGROUND: Idiopathic ventricular arrhythmias (IVAs) arising from different portions of the communicating vein of the left ventricular summit (summit-CV) are not a rare phenomenon. Whereas its electrocardiographic (ECG) and electrophysiological characteristics are not fully investigated. OBJECTIVE: This study aimed to identify distinct ECG and electrophysiological features of IVAs originating from different portions of summit-CV. METHODS: Nineteen patients confirmed arising from summit-CV were included in this study. RESULTS: The 19 patients were divided into proximal and distal portion groups based on their target sites in summit-CV. In the proximal portion group, 100% (11/11) VAs showed dominant negative (rs or QS) waves in lead I, while in the distal portion group, 87.5% (7/8) showed dominant positive waves (R, Rs or r) (p < 0.000). In lead V1, 100% (11/11) of the proximal portion group showed dominant positive waves (R or Rs), while 62.50% (5/8) of the distal portion group showed positive and negative bidirectional or negative waves (RS or rS) (p < 0.005). RI>4mV, SI<3.5mV, RV1<13mV, SV1>3.5mV, RI/SI>0.83, and RV1/SV1< 2.6 indicated a distal portion of summit-CV with the predictive value of 0.909, 1.000, 0.653, 0.972, 0.903, 0.966, respectively. A more positive wave in lead I and a more negative wave in lead V1 indicated more distal origin in summit-CV. Target sites in proximal and distal summit-CV groups showed similar electrophysiological characteristics during mapping. CONCLUSIONS: There were significant differences in ECG characteristics of VAs at different portions of summit-CV, which could aid pre-procedure planning and facilitate radiofrequency catheter ablation (RFCA) procedures.


Asunto(s)
Potenciales de Acción , Ablación por Catéter , Electrocardiografía , Frecuencia Cardíaca , Ventrículos Cardíacos , Valor Predictivo de las Pruebas , Humanos , Ablación por Catéter/efectos adversos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Resultado del Tratamiento , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/cirugía , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/diagnóstico , Técnicas Electrofisiológicas Cardíacas , Estudios Retrospectivos , Anciano
3.
Radiographics ; 44(9): e230222, 2024 09.
Artículo en Inglés | MEDLINE | ID: mdl-39115996

RESUMEN

Cardiac electrophysiology involves the diagnosis and management of arrhythmias. CT and MRI play an increasingly important role in cardiac electrophysiology, primarily in preprocedural planning of ablation procedures but also in procedural guidance and postprocedural follow-up. The most common applications include ablation for atrial fibrillation (AF), ablation for ventricular tachycardia (VT), and for planning cardiac resynchronization therapy (CRT). For AF ablation, preprocedural evaluation includes anatomic evaluation and planning using CT or MRI as well as evaluation for left atrial fibrosis using MRI, a marker of poor outcomes following ablation. Procedural guidance during AF ablation is achieved by fusing anatomic data from CT or MRI with electroanatomic mapping to guide the procedure. Postprocedural imaging with CT following AF ablation is commonly used to evaluate for complications such as pulmonary vein stenosis and atrioesophageal fistula. For VT ablation, both MRI and CT are used to identify scar, representing the arrhythmogenic substrate targeted for ablation, and to plan the optimal approach for ablation. CT or MR images may be fused with electroanatomic maps for intraprocedural guidance during VT ablation and may also be used to assess for complications following ablation. Finally, functional information from MRI may be used to identify patients who may benefit from CRT, and cardiac vein mapping with CT or MRI may assist in planning access. ©RSNA, 2024 Supplemental material is available for this article.


Asunto(s)
Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos , Ablación por Catéter/métodos , Taquicardia Ventricular/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas/métodos , Arritmias Cardíacas/diagnóstico por imagen
4.
Int J Cardiol ; 415: 132465, 2024 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-39159757

RESUMEN

OBJECTIVE: Atrial fibrillation (AF) is a common arrhythmia that increases morbidity and mortality, as well as healthcare costs. The induction of AF (IAF) during programmed atrial pacing in an electrophysiological study (EPS) is a prevalent phenomenon that has been underappreciated by electrophysiologists. Despite extensive research on AF, only a few studies have focused on this phenomenon. The aim of our study was to investigate the association between history of AF and IAF and the underlying pathophysiological factors such as arterial stiffness, subclinical atherosclerosis, and impaired endothelial function. METHODS: This cross-sectional and observational study included 87 patients who had palpitations and were scheduled for EPS. Patients underwent biochemical investigations, transthoracic echocardiography, carotid ultrasound, carotid-femoral artery pulse wave velocity (PWV), and flow-mediated dilatation (FMD) measurements before EPS. Patients were divided into two groups, AF-induced and non-induced in EPS, for further statistical analysis. RESULTS: AF was induced in 16 of 87 patients (18.3%) included in the analysis. The FMD (%) was significantly lower (16.01 ± 10.1 vs. 8.7 ± 5.7, P = 0.022) and, remarkably, the proportion of patients with a history of AF was significantly higher (2.8% vs. 37.5%, P < 0.001) in the IAF group. ROC analysis showed that a documented AF and FMD predicted IAF, with AUC of 0.741 (p = 0.012) and 0.740 (p = 0.001), respectively. Logistic regression analysis revealed that FMD and history of AF were strong predictors of IAF (odds ratio [OR], 0.853; 95% confidence interval [CI] 0.737-0.988; P = 0.034, OR: 10.1, 95% CI 4.9-20.5; P = 0.003, respectively). CONCLUSION: Endothelial dysfunction and documented AF were associated with IAF during EPS.


Asunto(s)
Fibrilación Atrial , Endotelio Vascular , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Femenino , Masculino , Estudios Transversales , Persona de Mediana Edad , Endotelio Vascular/fisiopatología , Endotelio Vascular/diagnóstico por imagen , Anciano , Rigidez Vascular/fisiología , Técnicas Electrofisiológicas Cardíacas/métodos
5.
Europace ; 26(9)2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39166530

RESUMEN

AIMS: Pulsed-field ablation (PFA) is an emerging technology to perform pulmonary vein isolation (PVI). Initial data demonstrated high safety and efficacy. Data on long-term PVI durability and reconduction patterns in comparison to established energy sources for PVI are scarce. We compare findings in repeat ablation procedures after a first PFA to findings in repeat ablation procedures after a first cryoballoon ablation (CBA) based PVI. METHODS AND RESULT: A total of 550 consecutively enrolled patients underwent PFA or CBA index PVI. Repeat ablations in patients with symptomatic atrial arrhythmia recurrences were analysed. A total of 22/191 (12%) patients after index PFA-PVI and 44/359 (12%) after CBA-PVI underwent repeat ablation. Reconduction of any pulmonary vein (PV) was detected by multipolar spiral mapping catheter at each PV with careful evaluation of PV potentials and by 3D-mapping in 16/22 patients (73%) after PFA-PVI and in 33/44 (75%) after CBA-PVI (P = 1.000). Of 82 initially isolated PVs after PFA-PVI, 31 (38%) were reconducting; of 169 isolated PVs after CBA-PVI, 63 (37%) were reconducting (P = 0.936). Clinical atrial tachycardia occurred similarly in patients after PFA (5/22; 23%) and CBA (7/44; 16%; P = 0.515). Roof lines were set more often after PFA- (8/22; 36%) compared with CBA-PVI (5/44; 11%; P = 0.023). Repeat procedure duration [PFA: 87 (76, 123) min; CBA: 93 (75, 128) min; P = 0.446] was similar and fluoroscopy time [PFA: 11 (9, 14) min; CBA: 11 (8, 14) min; P = 0.739] equal between groups at repeat ablation. CONCLUSION: During repeat ablation after previous PFA- or CBA-based PVI, electrical PV-reconduction rates and patterns were similar.


Asunto(s)
Fibrilación Atrial , Criocirugía , Venas Pulmonares , Recurrencia , Reoperación , Humanos , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Criocirugía/métodos , Criocirugía/efectos adversos , Criocirugía/instrumentación , Masculino , Femenino , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Persona de Mediana Edad , Anciano , Reoperación/estadística & datos numéricos , Resultado del Tratamiento , Ablación por Catéter/métodos , Factores de Tiempo , Potenciales de Acción , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca
7.
Europace ; 26(8)2024 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-39082747

RESUMEN

AIMS: Right phrenic nerve (RPN) injury is a disabling but uncommon complication of atrial fibrillation (AF) radiofrequency ablation. Pace-mapping is widely used to infer RPN's course, for limiting the risk of palsy by avoiding ablation at capture sites. However, information is lacking regarding the distance between the endocardial sites of capture and the actual anatomic RPN location. We aimed at determining the distance between endocardial sites of capture and anatomic CT location of the RPN, depending on the capture threshold. METHODS AND RESULTS: In consecutive patients undergoing AF radiofrequency ablation, we defined the course of the RPN on the electroanatomical map with high-output pacing at up to 50 mA/2 ms, and assessed RPN capture threshold (RPN-t). The true anatomic course of the RPN was delineated and segmented using CT scan, then merged with the electroanatomical map. The distance between pacing sites and the RPN was assessed. In 45 patients, 1033 pacing sites were analysed. Distances from pacing sites to RPN ranged from 7.5 ± 3.0 mm (min 1) when RPN-t was ≤10 mA to 19.2 ± 6.5 mm (min 9.4) in cases of non-capture at 50 mA. A distance to the phrenic nerve > 10 mm was predicted by RPN-t with a ROC curve area of 0.846 [0.821-0.870] (P < 0.001), with Se = 80.8% and Sp = 77.5% if RPN-t > 20 mA, Se = 68.0% and Sp = 91.6% if RPN-t > 30 mA, and Se = 42.4% and Sp = 97.6% if non-capture at 50 mA. CONCLUSION: These data emphasize the utility of high-output pace-mapping of the RPN. Non-capture at 50 mA/2 ms demonstrated very high specificity for predicting a distance to the RPN > 10 mm, ensuring safe radiofrequency delivery.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Imagenología Tridimensional , Traumatismos de los Nervios Periféricos , Nervio Frénico , Valor Predictivo de las Pruebas , Humanos , Nervio Frénico/lesiones , Nervio Frénico/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Femenino , Masculino , Persona de Mediana Edad , Anciano , Ablación por Catéter/métodos , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/prevención & control , Resultado del Tratamiento , Técnicas Electrofisiológicas Cardíacas , Tomografía Computarizada por Rayos X , Estimulación Cardíaca Artificial/métodos , Interpretación de Imagen Radiográfica Asistida por Computador , Potenciales de Acción , Curva ROC
8.
Curr Cardiol Rep ; 26(9): 903-910, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39023800

RESUMEN

PURPOSE OF REVIEW: Cardiovascular magnetic resonance (CMR) imaging excels in providing detailed three-dimensional anatomical information together with excellent soft tissue contrast and has already become a valuable tool for diagnostic evaluation, electrophysiological procedure (EP) planning, and therapeutical stratification of atrial or ventricular rhythm disorders. CMR-based identification of ablation targets may significantly impact existing concepts of interventional electrophysiology. In order to exploit the inherent advantages of CMR imaging to the fullest, CMR-guided ablation procedures (EP-CMR) are justly considered the ultimate goal. RECENT FINDINGS: Electrophysiological cardiovascular magnetic resonance (EP-CMR) interventional procedures have more recently been introduced to the CMR armamentarium: in a single-center series of 30 patients, an EP-CMR guided ablation success of 93% has been reported, which is comparable to conventional ablation outcomes for typical atrial flutter and procedure and ablation time were also reported to be comparable. However, moving on from already established workflows for the ablation of typical atrial flutter in the interventional CMR environment to treatment of more complex ventricular arrhythmias calls for technical advances regarding development of catheters, sheaths and CMR-compatible defibrillator equipment. CMR imaging has already become an important diagnostic tool in the standard clinical assessment of cardiac arrhythmias. Previous studies have demonstrated the feasibility and safety of performing electrophysiological interventional procedures within the CMR environment and fully CMR-guided ablation of typical atrial flutter can be implemented as a routine procedure in experienced centers. Building upon established workflows, the market release of new, CMR-compatible interventional devices may finally enable targeting ventricular arrhythmias.


Asunto(s)
Ablación por Catéter , Imagen por Resonancia Magnética Intervencional , Humanos , Ablación por Catéter/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/terapia
9.
Circ Arrhythm Electrophysiol ; 17(8): e012829, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39051110

RESUMEN

BACKGROUND: The clinical outcome of pulmonary vein isolation (PVI) for persistent atrial fibrillation (AF) is suboptimal. Mapping studies have demonstrated atrial sites outside of the pulmonary veins displaying focal activation patterns during AF. We sought to determine whether adding catheter ablation of focal activation sites to PVI improves clinical outcomes of catheter ablation for persistent AF. METHODS: In this multicenter, randomized, single-blinded trial, we assigned patients with persistent AF to either PVI alone or to mapping-guided ablation of focal activation sites in addition to PVI in a 1:1 ratio. In the mapping-guided group, both atria were mapped after PVI using a Pentaray catheter (Biosense-Webster) and focal activation sites identified by CARTOFINDER (Biosense-Webster) were ablated. The primary end point was freedom from AF or atrial tachycardia without antiarrhythmic drugs beyond a 90-day blanking period. RESULTS: A total of 98 patients were assigned to the mapping-guided group and 102 to the PVI alone group. In the mapping-guided group, focal activation sites were identified at 2.6±0.3 and 2.5±0.2 sites per patient in the left and right atrium, respectively. Patients were followed up for 768.5 (interquartile range, 723.75-915.75) and 755.5 days (interquartile range, 728.5-913.75) in the mapping-guided ablation and the PVI alone groups, respectively. Freedom from AF/atrial tachycardia without antiarrhythmic drugs at 2-year follow-up was 66.8% and 75.2% in the mapping-guided ablation and the PVI alone groups, respectively (hazard ratio, 1.26 [95% CI, 0.76-2.10]; P=0.37). Adverse events occurred in 3 patients (3.0%) and none (0%) in the mapping-guided ablation and the PVI alone groups, respectively (P=0.12). CONCLUSIONS: In patients with persistent AF, the addition of mapping-guided ablation of focal activation sites to PVI did not improve clinical outcomes compared with PVI alone. REGISTRATION: URL: https://center6.umin.ac.jp/cgi-open-bin/ctr/index.cgi?function=02; Unique identifier: UMIN000037569.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Método Simple Ciego , Persona de Mediana Edad , Anciano , Frecuencia Cardíaca , Factores de Tiempo , Recurrencia , Resultado del Tratamiento , Técnicas Electrofisiológicas Cardíacas , Potenciales de Acción
10.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38954426

RESUMEN

AIMS: Prior case series showed promising results for cardioneuroablation in patients with vagally induced atrioventricular blocks (VAVBs). We aimed to examine the acute procedural characteristics and intermediate-term outcomes of electroanatomical-guided cardioneuroablation (EACNA) in patients with VAVB. METHODS AND RESULTS: This international multicentre retrospective registry included data collected from 20 centres. Patients presenting with symptomatic paroxysmal or persistent VAVB were included in the study. All patients underwent EACNA. Procedural success was defined by the acute reversal of atrioventricular blocks (AVBs) and complete abolition of atropine response. The primary outcome was occurrence of syncope and daytime second- or advanced-degree AVB on serial prolonged electrocardiogram monitoring during follow-up. A total of 130 patients underwent EACNA. Acute procedural success was achieved in 96.2% of the cases. During a median follow-up of 300 days (150, 496), the primary outcome occurred in 17/125 (14%) cases with acute procedural success (recurrence of AVB in 9 and new syncope in 8 cases). Operator experience and use of extracardiac vagal stimulation were similar for patients with and without primary outcomes. A history of atrial fibrillation, hypertension, and coronary artery disease was associated with a higher primary outcome occurrence. Only four patients with primary outcome required pacemaker placement during follow-up. CONCLUSION: This is the largest multicentre study demonstrating the feasibility of EACNA with encouraging intermediate-term outcomes in selected patients with VAVB. Studies investigating the effect on burden of daytime symptoms caused by the AVB are required to confirm these findings.


Asunto(s)
Bloqueo Atrioventricular , Sistema de Registros , Humanos , Masculino , Femenino , Estudios Retrospectivos , Anciano , Persona de Mediana Edad , Resultado del Tratamiento , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/cirugía , Ablación por Catéter/métodos , Factores de Tiempo , Estimulación del Nervio Vago/métodos , Técnicas Electrofisiológicas Cardíacas , Síncope/etiología , Recurrencia , Nodo Atrioventricular/cirugía , Nodo Atrioventricular/fisiopatología
11.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38988256

RESUMEN

AIMS: A pulsed electric field (PF) energy source is a novel potential option for catheter ablation of ventricular arrhythmias (VAs) as it can create deeper lesions, particularly in scarred tissue. However, very limited data exist on its efficacy and safety. This prospective observational study reports the initial experience with VA ablation using focal PF. METHODS AND RESULTS: The study population consisted of 44 patients (16 women, aged 61 ± 14years) with either frequent ventricular premature complexes (VPCs, 48%) or scar-related ventricular tachycardia (VT, 52%). Ablation was performed using an irrigated 4 mm tip catheter and a commercially available PF generator. On average, 16 ± 15 PF applications (25 A) were delivered per patient. Acute success was achieved in 84% of patients as assessed by elimination of VPC or reaching non-inducibility of VT. In three cases (7%), a transient conduction system block was observed during PF applications remotely from the septum. Root analysis revealed that this event was caused by current leakage from the proximal shaft electrodes in contact with the basal interventricular septum. Acute elimination of VPC was achieved in 81% patients and non-inducibility of VT in 83% patients. At the 3-month follow-up, persistent suppression of the VPC was confirmed on Holter monitoring in 81% patients. In the VT group, the mean follow-up was 116 ± 75 days and a total of 52% patients remained free of any VA. CONCLUSION: Pulsed electric field catheter ablation of a broad spectrum of VA is feasible with acute high efficacy; however, the short-term follow-up is less satisfactory for patients with scar-related VT.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Humanos , Femenino , Persona de Mediana Edad , Masculino , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/fisiopatología , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Resultado del Tratamiento , Anciano , Complejos Prematuros Ventriculares/cirugía , Complejos Prematuros Ventriculares/fisiopatología , Complejos Prematuros Ventriculares/diagnóstico , Estudios Prospectivos , Cicatriz/etiología , Técnicas Electrofisiológicas Cardíacas
12.
J Electrocardiol ; 86: 153764, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39079368

RESUMEN

BACKGROUND: Currently, the interrupted recording technique is commonly used to perform left bundle branch (LBB) pacing (LBBP). However, this method requires repeated testing to confirm that the LBB is captured and perforations are avoided. An automated solution may make this repetitive work easier. CASE SUMMARY: LBBP was performed using an uninterrupted recording technique in an 86-year-old woman. Lead position and LBB capture was confirmed by the characteristics of the intrinsic filtered and unfiltered intracardiac electrograms. CONCLUSION: Continuous mapping and recording technique may help achieve more accurate positioning of LBBP lead in the ventricular septum.


Asunto(s)
Bloqueo de Rama , Electrocardiografía , Humanos , Femenino , Anciano de 80 o más Años , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/diagnóstico , Electrocardiografía/métodos , Estimulación Cardíaca Artificial/métodos , Técnicas Electrofisiológicas Cardíacas/métodos
13.
BMC Cardiovasc Disord ; 24(1): 340, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38970012

RESUMEN

Atrial flutter, a prevalent cardiac arrhythmia, is primarily characterized by reentrant circuits in the right atrium. However, atypical forms of atrial flutter present distinct challenges in terms of diagnosis and treatment. In this study, we examine three noteworthy clinical cases of atypical atrial flutter, which offer compelling evidence indicating the implication of the lesser-known Septopulmonary Bundle (SPB). This inference is based on the identification of distinct electrocardiographic patterns observed in these patients and their favorable response to catheter ablation, which is a standard treatment for atrial flutter. Remarkably, in each case, targeted ablation at the anterior portion of the left atrial roof effectively terminated the arrhythmia, thus providing further support for the hypothesis of SPB involvement. These insightful observations shed light on the potential significance of the SPB in the etiology of atypical atrial flutter and introduce a promising therapeutic target. We anticipate that this paper will stimulate further exploration into the role of the SPB in atrial flutter and pave the way for the development of targeted ablation strategies.


Asunto(s)
Potenciales de Acción , Aleteo Atrial , Ablación por Catéter , Electrocardiografía , Frecuencia Cardíaca , Aleteo Atrial/fisiopatología , Aleteo Atrial/diagnóstico , Aleteo Atrial/cirugía , Aleteo Atrial/terapia , Aleteo Atrial/etiología , Humanos , Masculino , Resultado del Tratamiento , Persona de Mediana Edad , Femenino , Anciano , Pericardio/fisiopatología , Técnicas Electrofisiológicas Cardíacas
14.
BMC Cardiovasc Disord ; 24(1): 347, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38977958

RESUMEN

BACKGROUND: CHA2DS2-VASc score-related differences have been reported in atrial fibrotic remodeling and prognosis of atrial fibrillation (AF) patients after ablation. There are currently no data on the efficacy of low voltage zone (LVZ)-guided ablation in persistent AF patients according to CHA2DS2-VASc score. We assessed in a cohort of persistent AF patients the extent of LVZ, the regional distribution of LA voltage and the outcome of LA voltage-guided substrate ablation in addition to PVI according to CHA2DS2-VASc score. METHODS: 138 consecutive persistent AF patients undergoing a first voltage-guided catheter ablation were enrolled. 58 patients with CHAD2DS2-VASc score ≥ 3 and 80 patients with CHAD2DS2-VASc score ≤ 2 were included. LA voltage maps were obtained using 3D-electroanatomical mapping system in sinus rhythm. LVZ was defined as < 0.5 mV. RESULTS: In the high CHAD2DS2-VASc score group, LA voltage was lower (1.5 [1.1-2.5] vs. 2.3 [1.5-2.8] mV, p = 0.02) and LVZs were more frequently identified (40% vs. 18%), p < 0.01). Female with CHA2DS2-VASc score ≥ 3 (p = 0.031), LA indexed volume (p = 0.009) and P-wave duration ≥ 150 ms (p = 0.001) were predictors of LVZ. After a 36-month follow-up, atrial arrhythmia-free survival was similar between the two groups (logrank test, P = 0.676). CONCLUSIONS: AF patients with CHAD2DS2-VASc score ≥ 3 display more LA substrate remodeling with lower voltage and more LVZs compared with those with CHAD2DS2-VASc score ≤ 2. Despite this atrial remodeling, they had similar and favorable 36 months results after one single procedure. Unlike male with CHAD2DS2-VASc score ≥ 3, female with CHAD2DS2-VASc score ≥ 3 was predictor of LVZ occurrence.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Función del Atrio Izquierdo , Remodelación Atrial , Ablación por Catéter , Valor Predictivo de las Pruebas , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/mortalidad , Femenino , Masculino , Ablación por Catéter/efectos adversos , Persona de Mediana Edad , Anciano , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Frecuencia Cardíaca , Técnicas de Apoyo para la Decisión , Técnicas Electrofisiológicas Cardíacas , Recurrencia , Estudios Retrospectivos
18.
Pacing Clin Electrophysiol ; 47(8): 1079-1086, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39031595

RESUMEN

BACKGROUND: Identification of infrequent nonpulmonary vein trigger premature atrial contractions (PACs) is challenging. We hypothesized that pace mapping (PM) assessed by correlation scores calculated by an intracardiac pattern matching (ICPM) module was useful for locating PAC origins, and conducted a validation study to assess the accuracy of ICPM-guided PM. METHODS: Analyzed were 30 patients with atrial fibrillation. After pulmonary vein isolation, atrial pacing was performed at one or two of four sites on the anterior and posterior aspects of the left atrium (LA, n = 10/10), LA septum (n = 10), and lateral RA (n = 10), which was arbitrarily determined as PAC. The intracardiac activation obtained from each pacing was set as an ICPM reference consisting of six CS unipolar electrograms (CS group) or six CS unipolar electrograms and four RA electrograms (CS-RA group). RESULTS: The PM was performed at 193 ± 107 sites for each reference pacing site. All reference pacing sites corresponded to sites where the maximal ICPM correlation score was obtained. Sites with a correlation score ≥98% were rarely obtained in the CS-RA than CS group (33% vs. 55%, P = .04), but those ≥95% were similarly obtained between the two groups (93% vs. 88%, P = .71), and those ≥90% were obtained in all. The surface areas with correlation scores ≥98% (0[0,10] vs. 10[0,35] mm2, P = .02), ≥95% (10[10,30] vs. 50[10,180] mm2, P = .002) and ≥90% (60[30,100] vs. 170[100,560] mm2, P = .0002) were smaller in the CS-RA than CS group. CONCLUSIONS: ICPM-guided PM was useful for identifying the reference pacing sites. Combined use of RA and CS electrograms may improve the mapping quality.


Asunto(s)
Fibrilación Atrial , Venas Pulmonares , Humanos , Femenino , Masculino , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Venas Pulmonares/fisiopatología , Anciano , Mapeo del Potencial de Superficie Corporal/métodos , Reproducibilidad de los Resultados , Persona de Mediana Edad , Técnicas Electrofisiológicas Cardíacas/métodos , Sensibilidad y Especificidad , Atrios Cardíacos/fisiopatología
20.
JACC Clin Electrophysiol ; 10(8): 1856-1869, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38842972

RESUMEN

BACKGROUND: Electrographic flow (EGF) mapping enables full spatiotemporal reconstruction of organized wavefront propagation to identify extrapulmonary vein sources of atrial fibrillation (AF). OBJECTIVES: FLOW-AF (A Randomized Controlled Study to Evaluate the Reliability of the Ablacon Electrographic FLOW [EGF] Algorithm Technology [Ablamap Software] to Identify AF Sources and Guide Ablation Therapy in Patients With Persistent Atrial Fibrillation) was multicenter, randomized controlled study of EGF mapping to: 1) stratify a nonparoxysmal AF population undergoing redo ablation; 2) guide ablation of these extrapulmonary vein AF sources; and 3) improve AF recurrence outcomes. METHODS: FLOW-AF enrolled persistent atrial fibrillation (PerAF)/long-standing PerAF patients undergoing redo ablation at 4 centers. One-minute EGF maps were recorded from standardized biatrial basket positions. Patients with source activity ≥26.5% were randomized 1:1 to PVI + EGF-guided ablation vs PVI only; patients without sources ≥26.5% threshold were not randomized. Follow-up and electrocardiographic monitoring occurred at 3, 6, and 12 months. RESULTS: We enrolled 85 patients (age 65.6 ± 9.3 years, 37% female, 24% long-standing PerAF). Thirty-four (40%) patients had no sources greater than threshold; at least 1 source greater than threshold was present in 46 (60%) (EGF-guided ablation, n = 22; control group, n = 26). Patients with sources were older (68.2 vs 62.6 years; P = 0.005) with higher CHA2DS2-VASc scores (2.8 vs 1.9; P = 0.001). The freedom from safety events was 97.2%, and 95% of EGF-identified sources were successfully ablated. In randomized patients, AF-free survival at 12 months was 68% for EGF-guided ablation vs 17% for the control group (P = 0.042); freedom from AF/atrial tachycardia/atrial flutter at 12 months was 51% vs 14% (P = 0.103), respectively. CONCLUSIONS: In nonparoxysmal AF patients undergoing redo ablation, EGF mapping identified AF sources in 60% of patients, and could be successfully ablated in 95%. Compared with PVI alone, PVI + source ablation improved AF-free survival by 51% on an absolute basis. (FLOW-AF: A Study to Evaluate the Ablacon Electrographic FLOW EGF Technology [A Randomized Controlled Study to Evaluate the Reliability of the Ablacon Electrographic FLOW (EGF) Algorithm Technology (Ablamap Software) to Identify AF Sources and Guide Ablation Therapy in Patients With Persistent Atrial Fibrillation]; NCT04473963).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Femenino , Masculino , Persona de Mediana Edad , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Anciano , Reoperación/estadística & datos numéricos , Técnicas Electrofisiológicas Cardíacas/métodos , Resultado del Tratamiento , Algoritmos , Electrocardiografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA