Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 13.078
Filtrar
1.
Methods Mol Biol ; 2852: 47-64, 2025.
Artículo en Inglés | MEDLINE | ID: mdl-39235736

RESUMEN

Electrochemical approaches, along with miniaturization of electrodes, are increasingly being employed to detect and quantify nucleic acid biomarkers. Miniaturization of the electrodes is achieved through the use of screen-printed electrodes (SPEs), which consist of one to a few dozen sets of electrodes, or by utilizing printed circuit boards. Electrode materials used in SPEs include glassy carbon (Chiang H-C, Wang Y, Zhang Q, Levon K, Biosensors (Basel) 9:2-11, 2019), platinum, carbon, and graphene (Cheng FF, He TT, Miao HT, Shi JJ, Jiang LP, Zhu JJ, ACS Appl Mater Interfaces 7:2979-2985, 2015). There are numerous modifications to the electrode surfaces as well (Cheng FF, He TT, Miao HT, Shi JJ, Jiang LP, Zhu JJ, ACS Appl Mater Interfaces 7:2979-2985, 2015). These approaches offer distinct advantages, primarily due to their demonstrated superior limit of detection without amplification. Using the SPEs and potentiostats, we can detect cells, proteins, DNA, and RNA concentrations in the nanomolar (nM) to attomolar (aM) range. The focus of this chapter is to describe the basic approach adopted for the use of SPEs for nucleic acid measurement.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Electrodos , Grafito , Grafito/química , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Ácidos Nucleicos/análisis , Humanos , ADN/análisis
2.
Food Chem ; 462: 140990, 2025 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-39208725

RESUMEN

The frequent occurrence of food safety incidents has aroused public concern about food safety and key contaminants. Foodborne pathogen contamination, pesticide residues, heavy metal residues, and other food safety problems will significantly impact human health. Therefore, developing efficient and sensitive detection method to ensure food safety early warning is paramount. The aptamer-based sensor (aptasensor) is a novel analytical tool with strong targeting, high sensitivity, low cost, etc. It has been extensively utilized in the pharmaceutical industry, biomedicine, environmental engineering, food safety detection, and in other diverse fields. This work reviewed the latest research progress of aptasensors for food analysis and detection, mainly introducing their application in detecting various key food contaminants. Subsequently, the sensing mechanism and performance of aptasensors are discussed. Finally, the review will examine the challenges and opportunities related to aptasensors for detecting major contaminants in food, and advance implementation of aptasensors in food safety and detection.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Contaminación de Alimentos , Inocuidad de los Alimentos , Nanoestructuras , Contaminación de Alimentos/análisis , Aptámeros de Nucleótidos/química , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Nanoestructuras/química , Humanos , Análisis de los Alimentos/métodos , Análisis de los Alimentos/instrumentación
3.
Food Chem ; 462: 140939, 2025 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-39208731

RESUMEN

Phoxim, extensively utilized in agriculture as an organothiophosphate insecticide, has the potential to cause neurotoxicity and pose human health hazards. In this study, an electrochemical enzyme biosensor based on Ti3C2 MXene/MoS2@AuNPs/AChE was constructed for the sensitive detection of phoxim. The two-dimensional multilayer structure of Ti3C2 MXene provides a robust framework for MoS2, leading to an expansion of the specific surface area and effectively preventing re-stacking of Ti3C2 MXene. Additionally, the synergistic effect of self-reduced grown AuNPs with MoS2 further improves the electrical conductivity of the composites, while the robust framework provides a favorable microenvironment for immobilization of enzyme molecules. Ti3C2 MXene/MoS2@AuNPs electrochemical enzyme sensor showed a significant response to phoxim in the range of 1 × 10-13 M to 1 × 10-7 M with a detection limit of 5.29 × 10-15 M. Moreover, the sensor demonstrated excellent repeatability, reproducibility, and stability, thereby showing its promising potential for real sample detection.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Frutas , Oro , Nanopartículas del Metal , Nanocompuestos , Compuestos Organotiofosforados , Titanio , Oro/química , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Nanocompuestos/química , Frutas/química , Nanopartículas del Metal/química , Técnicas Biosensibles/instrumentación , Compuestos Organotiofosforados/análisis , Titanio/química , Límite de Detección , Contaminación de Alimentos/análisis , Molibdeno/química , Insecticidas/análisis , Insecticidas/química , Residuos de Plaguicidas/análisis , Residuos de Plaguicidas/química
4.
Food Chem ; 462: 140922, 2025 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-39213967

RESUMEN

Rapid screening for foodborne pathogens is crucial for food safety. A rapid and one-step electrochemical sensor has been developed for the detection of Escherichia coli (E. coli), Staphylococcus aureus (S. aureus) and Salmonella typhimurium (S. typhimurium). Through the construction of aptamer/two-dimensional carboxylated Ti3C2Tx (2D C-Ti3C2Tx)/two-dimensional Zn-MOF (2D Zn-MOF) composites, the recognition elements, signal tags, and signal amplifiers are integrated on the electrode surface. Pathogens are selectively captured using the aptamer, which increases the impedance of the electrode surface,leads to a decrease in the 2D Zn-MOF current. Bacteria can be rapidly quantified using a one-step detection method and the replacement of aptamers. The detection limits for E. coli, S. aureus, and S. typhimurium are 6, 5, and 5 CFU·mL-1, respectively. The sensor demonstrated reliable detection capabilities in real-sample testing. Therefore, the one-step sensor based on the 2D Zn-MOF and 2D C-Ti3C2Tx has significant application value in the detection of foodborne pathogens.


Asunto(s)
Técnicas Electroquímicas , Escherichia coli , Salmonella typhimurium , Staphylococcus aureus , Zinc , Staphylococcus aureus/aislamiento & purificación , Salmonella typhimurium/aislamiento & purificación , Zinc/análisis , Escherichia coli/aislamiento & purificación , Técnicas Electroquímicas/instrumentación , Técnicas Biosensibles/instrumentación , Estructuras Metalorgánicas/química , Microbiología de Alimentos , Titanio/química , Límite de Detección , Electrodos , Contaminación de Alimentos/análisis
5.
Food Chem ; 462: 141026, 2025 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-39216373

RESUMEN

Quantitative monitoring of the concentrations of epigallocatechin gallate (EGCG) and cysteine (Cys) is of great significance for promoting human health. In this study, iron/aluminum bimetallic MOF material MIL-53 (Fe, Al) was rapidly prepared under room temperature using a co-precipitation method, followed by investigating the peroxidase-like (POD-like) activity of MIL-53(Fe, Al) using 3,3',5,5'-tetramethylbenzidine (TMB) as a chromogenic substrate. The results showed that the Michaelis -Menten constants of TMB and H2O2 as substrates were 0.167 mM and 0.108 mM, respectively. A colorimetric sensing platform for detecting EGCG and Cys was developed and successfully applied for analysis and quantitative detection using a smartphone. The linear detection range for EGCG was 15∼80 µM (R2=0.994) and for Cys was 7∼95 µM (R2=0.998). The limits of detection (LOD) were 0.719 µM and 0.363 µM for EGCG and Cys, respectively. This work provides a new and cost-effective approach for the real-time analysis of catechins and amino acids.


Asunto(s)
Antioxidantes , Técnicas Biosensibles , Catequina , Colorimetría , Teléfono Inteligente , Colorimetría/métodos , Colorimetría/instrumentación , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Antioxidantes/análisis , Antioxidantes/química , Catequina/análisis , Catequina/análogos & derivados , Catequina/química , Cisteína/análisis , Cisteína/análogos & derivados , Límite de Detección , Análisis de los Alimentos/métodos , Análisis de los Alimentos/instrumentación
6.
Biomaterials ; 313: 122810, 2025 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-39243673

RESUMEN

The development of biosensing electronics for real-time sweat analysis has attracted increasing research interest due to their promising applications for non-invasive health monitoring. However, one of the critical challenges lies in the sebum interference that largely limits the sensing reliability in practical scenarios. Herein, we report a flexible epidermal secretion-purified biosensing patch with a hydrogel filtering membrane that can effectively eliminate the impact of sebum and sebum-soluble substances. The as-prepared sebum filtering membranes feature a dual-layer sebum-resistant structure based on the poly(hydroxyethyl methacrylate) hydrogel functionalized with nano-brush structured poly(sulfobetaine) to eliminate interferences and provide self-cleaning capability. Furthermore, the unidirectional flow microfluidic channels design based on the Tesla valve was incorporated into the biosensing patch to prevent external sebum contamination and allow effective sweat refreshing for reliable sensing. By seamlessly combining these components, the epidermal secretion-purified biosensing patch enables continuous monitoring of sweat uric acid, pH, and sodium ions with significantly improved accuracy of up to 12 %. The proposed strategy for enhanced sweat sensing reliability without sebum interference shows desirable compatibility for different types of biosensors and would inspire the advances of flexible and wearable devices for non-invasive healthcare.


Asunto(s)
Técnicas Biosensibles , Hidrogeles , Sebo , Sudor , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Humanos , Sebo/metabolismo , Hidrogeles/química , Sudor/química , Epidermis/metabolismo , Dispositivos Electrónicos Vestibles , Microfluídica/métodos , Ácido Úrico/análisis , Membranas Artificiales , Concentración de Iones de Hidrógeno
7.
Anal Chim Acta ; 1325: 343117, 2024 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-39244304

RESUMEN

BACKGROUND: Diabetic retinopathy (DR), a chronic and progressive microvascular complication of diabetes mellitus, substantially threatens vision and is a leading cause of blindness among working-age individuals worldwide. Traditional diagnostic methods, such as ophthalmoscopy and fluorescein angiography are nonquantitative, invasive, and time consuming. Analysis of protein biomarkers in tear fluid offers noninvasive insights into ocular and systemic health, aiding in early DR detection. This study introduces a surface acoustic wave (SAW) microchip that rapidly enhances fluorescence in bead-based immunoassays for the sensitive and noninvasive DR detection from human tear samples. RESULTS: The device facilitated particle mixing for immunoassay formation and particle concentration in the droplet, resulting in an enhanced immunofluorescence signal. This detachable SAW microchip allows the disposal of the cover glass after every use, thereby improving the reusability of the interdigital transducer and minimizing potential cross-contamination. A preliminary clinical test was conducted on a cohort of 10 volunteers, including DR patients and healthy individuals. The results demonstrated strong agreement with ELISA studies, validating the high accuracy rate of the SAW microchip. SIGNIFICANCE: This comprehensive study offers significant insights into the potential application of a novel SAW microchip for the early detection of DR in individuals with diabetes. By utilizing protein biomarkers found in tear fluid, the device facilitates noninvasive, rapid, and sensitive detection, potentially revolutionizing DR diagnostics and improving patient outcomes through timely intervention and management of this vision-threatening condition.


Asunto(s)
Retinopatía Diabética , Lágrimas , Humanos , Lágrimas/química , Retinopatía Diabética/diagnóstico , Inmunoensayo/métodos , Sonido , Técnicas Biosensibles/instrumentación , Biomarcadores/análisis , Propiedades de Superficie
8.
ACS Nano ; 18(36): 24792-24802, 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39252606

RESUMEN

This study explores the fusion of a field-effect transistor (FET), a paper-based analytical cartridge, and the computational power of deep learning (DL) for quantitative biosensing via kinetic analyses. The FET sensors address the low sensitivity challenge observed in paper analytical devices, enabling electrical measurements with kinetic data. The paper-based cartridge eliminates the need for surface chemistry required in FET sensors, ensuring economical operation (cost < $0.15/test). The DL analysis mitigates chronic challenges of FET biosensors such as sample matrix interference, by leveraging kinetic data from target-specific bioreactions. In our proof-of-concept demonstration, our DL-based analyses showcased a coefficient of variation of <6.46% and a decent concentration measurement correlation with an r2 value of >0.976 for cholesterol testing when blindly compared to results obtained from a CLIA-certified clinical laboratory. These integrated technologies have the potential to advance FET-based biosensors, potentially transforming point-of-care diagnostics and at-home testing through enhanced accessibility, ease-of-use, and accuracy.


Asunto(s)
Técnicas Biosensibles , Aprendizaje Profundo , Papel , Transistores Electrónicos , Técnicas Biosensibles/instrumentación , Cinética , Colesterol/análisis , Humanos
9.
Biosens Bioelectron ; 266: 116736, 2024 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-39226751

RESUMEN

In photoelectrochemical (PEC) sensors, traditional detection modes such as "signal-on", "signal-off", and "polarity-switchable" limit target signals to a single polarity range, necessitating novel design strategies to enhance the operational scope. To overcome this limitation, we propose, for the first time, a "polarity-transcendent" design concept that enables a continuous response across the polarity spectrum, significantly broadening the sensor's concentration detection range. This concept is exemplified in our new "background-enhanced signal-off polarity-switchable" (BESOPS) mode, where the model analyte let-7a activates a cascade shearing reaction of a DNAzyme walker in conjunction with CRISPR/Cas12a, quantitatively peeling off Cu2O-H2 strands at the Cu2O/TiO2 electrode interface to expose the TiO2 surface. This exposure generates an anodic photocurrent at the expense of the cathodic photocurrent from Cu2O/TiO2, facilitating a seamless transition of the target signal from cathodic to anodic. Through systematic experiments and comparative analyses, the BESOPS sensor demonstrates highly sensitive and precise quantification of let-7a, with a detection limit of 2.5 aM and a broad operating range of 10 aM to 10 nM. Its performance exceeds most reported sensor platforms, highlighting the significant potential of our polarity-transcendent design in expanding the operational range of PEC sensors. This innovative approach paves the way for developing next-generation PEC sensors with enhanced applicability and heightened sensitivity in various critical fields.


Asunto(s)
Técnicas Biosensibles , Cobre , Técnicas Electroquímicas , Límite de Detección , Titanio , Técnicas Biosensibles/instrumentación , Técnicas Electroquímicas/métodos , Cobre/química , Titanio/química , MicroARNs/análisis , Humanos , Diseño de Equipo , Sistemas CRISPR-Cas , Electrodos
10.
Sensors (Basel) ; 24(17)2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39275446

RESUMEN

Particle plasmon resonance (PPR), or localized surface plasmon resonance (LSPR), utilizes intrinsic resonance in metal nanoparticles for sensor fabrication. While diffraction grating waveguides monitor bioaffinity adsorption with out-of-plane illumination, integrating them with PPR for biomolecular detection schemes remains underexplored. This study introduces a label-free biosensing platform integrating PPR with a diffraction grating waveguide. Gold nanoparticles are immobilized on a glass slide in contact with a sample, while a UV-assisted embossed diffraction grating is positioned opposite. The setup utilizes diffraction in reflection to detect changes in the environment's refractive index, indicating biomolecular binding at the gold nanoparticle surface. The positional shift of the diffracted beam, measured with varying refractive indices of sucrose solutions, shows a sensitivity of 0.97 mm/RIU at 8 cm from a position-sensitive detector, highlighting enhanced sensitivity due to PPR-diffraction coupling near the gold nanoparticle surface. Furthermore, the sensor achieved a resolution of 3.1 × 10-4 refractive index unit and a detection limit of 4.4 pM for detection of anti-DNP. The sensitivity of the diffracted spot was confirmed using finite element method (FEM) simulations in COMSOL Multiphysics. This study presents a significant advancement in biosensing technology, offering practical solutions for sensitive, rapid, and label-free biomolecule detection.


Asunto(s)
Técnicas Biosensibles , Oro , Nanopartículas del Metal , Resonancia por Plasmón de Superficie , Resonancia por Plasmón de Superficie/métodos , Oro/química , Nanopartículas del Metal/química , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Refractometría , Análisis de Elementos Finitos , Límite de Detección
11.
Sensors (Basel) ; 24(17)2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39275538

RESUMEN

Wearable sensors for sweat trace metal monitoring have the challenges of effective sweat collection and the real-time recording of detection signals. The existing detection technologies are implemented by generating enough sweat through exercise, which makes detecting trace metals in sweat cumbersome. Generally, it takes around 20 min to obtain enough sweat, resulting in dallied and prolonged detection signals that cannot reflect the endogenous fluctuations of the body. To solve these problems, we prepared a multifunctional hydrogel as an electrolyte and combined it with a flexible patch electrode to realize real-time monitoring of sweat Zn2+. Such hydrogel has magnetic and porous properties, and the porous structure of hydrogel enables a fast absorption of sweat, and the magnetic property of the addition of fabricated Fe3O4 NPs not only improves the conductivity but also ensures the adjustable internal structures of the hydrogel. Such a sensing platform for sweat Zn2+ monitoring shows a satisfied linear relationship in the concentration range of 0.16-16 µg/mL via differential pulsed anodic striping voltammetry (DPASV) and successfully detects the sweat Zn2+ of four volunteers during exercise and resting, displaying a promising path for commercial application.


Asunto(s)
Hidrogeles , Sudor , Dispositivos Electrónicos Vestibles , Zinc , Zinc/química , Sudor/química , Humanos , Hidrogeles/química , Porosidad , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Electrodos , Iones/química , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación
12.
Sensors (Basel) ; 24(17)2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39275547

RESUMEN

Prevalence estimates of Parkinson's disease (PD)-the fastest-growing neurodegenerative disease-are generally underestimated due to issues surrounding diagnostic accuracy, symptomatic undiagnosed cases, suboptimal prodromal monitoring, and limited screening access. Remotely monitored wearable devices and sensors provide precise, objective, and frequent measures of motor and non-motor symptoms. Here, we used consumer-grade wearable device and sensor data from the WATCH-PD study to develop a PD screening tool aimed at eliminating the gap between patient symptoms and diagnosis. Early-stage PD patients (n = 82) and age-matched comparison participants (n = 50) completed a multidomain assessment battery during a one-year longitudinal multicenter study. Using disease- and behavior-relevant feature engineering and multivariate machine learning modeling of early-stage PD status, we developed a highly accurate (92.3%), sensitive (90.0%), and specific (100%) random forest classification model (AUC = 0.92) that performed well across environmental and platform contexts. These findings provide robust support for further exploration of consumer-grade wearable devices and sensors for global population-wide PD screening and surveillance.


Asunto(s)
Enfermedad de Parkinson , Dispositivos Electrónicos Vestibles , Humanos , Enfermedad de Parkinson/diagnóstico , Masculino , Femenino , Persona de Mediana Edad , Anciano , Aprendizaje Automático , Estudios Longitudinales , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos
13.
Sensors (Basel) ; 24(17)2024 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-39275589

RESUMEN

This review explores the emerging role of screen-printed electrodes (SPEs) in the detection of breast cancer biomarkers. We discuss the fundamental principles and fabrication techniques of SPEs, highlighting their adaptability and cost-effectiveness. The review examines various modification strategies, including nanomaterial incorporation, polymer coatings, and biomolecule immobilization, which enhance sensor performance. We analyze the application of SPEs in detecting protein, genetic, and metabolite biomarkers associated with breast cancer, presenting recent advancements and innovative approaches. The integration of SPEs with microfluidic systems and their potential in wearable devices for continuous monitoring are explored. While emphasizing the promising aspects of SPE-based biosensors, we also address current challenges in sensitivity, specificity, and real-world applicability. The review concludes by discussing future perspectives, including the potential for early screening and therapy monitoring, and the steps required for clinical implementation. This comprehensive overview aims to stimulate further research and development in SPE-based biosensors for improved breast cancer management.


Asunto(s)
Biomarcadores de Tumor , Técnicas Biosensibles , Neoplasias de la Mama , Electrodos , Humanos , Neoplasias de la Mama/diagnóstico , Biomarcadores de Tumor/análisis , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Femenino
14.
Sensors (Basel) ; 24(17)2024 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-39275599

RESUMEN

The quality and authenticity of milk are of paramount importance. Cow milk is more allergenic and less nutritious than ewe, goat, or donkey milk, which are often adulterated with cow milk due to their seasonal availability and higher prices. In this work, a silicon photonic dipstick sensor accommodating two U-shaped Mach-Zehnder Interferometers (MZIs) was employed for the label-free detection of the adulteration of ewe, goat, and donkey milk with cow milk. One of the two MZIs of the chip was modified with bovine κ-casein, while the other was modified with bovine serum albumin to serve as a blank. All assay steps were performed by immersion of the chip side where the MZIs are positioned into the reagent solutions, leading to a photonic dipstick immunosensor. Thus, the chip was first immersed in a mixture of milk with anti-bovine κ-casein antibody and then in a secondary antibody solution for signal enhancement. A limit of detection of 0.05% v/v cow milk in ewe, goat, or donkey milk was achieved in 12 min using a 50-times diluted sample. This fast, sensitive, and simple assay, without the need for sample pre-processing, microfluidics, or pumps, makes the developed sensor ideal for the detection of milk adulteration at the point of need.


Asunto(s)
Técnicas Biosensibles , Caseínas , Equidae , Cabras , Leche , Animales , Leche/química , Leche/inmunología , Bovinos , Caseínas/análisis , Caseínas/inmunología , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Ovinos , Inmunoensayo/métodos , Contaminación de Alimentos/análisis , Fotones
15.
Sensors (Basel) ; 24(17)2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39275614

RESUMEN

Musculoskeletal Disorders (MSDs) stand as a prominent cause of injuries in modern agriculture. Scientific research has highlighted a causal link between MSDs and awkward working postures. Several methods for the evaluation of working postures, and related risks, have been developed such as the Rapid Upper Limb Assessment (RULA). Nevertheless, these methods are generally applied with manual measurements on pictures or videos. As a consequence, their applicability could be scarce, and their effectiveness could be limited. The use of wearable sensors to collect kinetic data could facilitate the use of these methods for risk assessment. Nevertheless, the existing system may not be usable in the agricultural and vine sectors because of its cost, robustness and versatility to the various anthropometric characteristics of workers. The aim of this study was to develop a technology capable of collecting accurate data about uncomfortable postures and repetitive movements typical of vine workers. Specific objectives of the project were the development of a low-cost, robust, and wearable device, which could measure data about wrist angles and workers' hand positions during possible viticultural operations. Furthermore, the project was meant to test its use to evaluate incongruous postures and repetitive movements of workers' hand positions during pruning operations in vineyard. The developed sensor had 3-axis accelerometers and a gyroscope, and it could monitor the positions of the hand-wrist-forearm musculoskeletal system when moving. When such a sensor was applied to the study of a real case, such as the pruning of a vines, it permitted the evaluation of a simulated sequence of pruning and the quantification of the levels of risk induced by this type of agricultural activity.


Asunto(s)
Postura , Dispositivos Electrónicos Vestibles , Humanos , Postura/fisiología , Enfermedades Musculoesqueléticas/fisiopatología , Agricultura/métodos , Agricultura/instrumentación , Muñeca/fisiología , Fenómenos Biomecánicos/fisiología , Adulto , Masculino , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Movimiento/fisiología
16.
Sensors (Basel) ; 24(17)2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-39275680

RESUMEN

Continuous Glucose Monitoring (CGM) not only can be used for glycemic control in chronic diseases (e.g., diabetes), but is increasingly being utilized by individuals and athletes to monitor fluctuations in training and everyday life. However, it is not clear how accurately CGM reflects plasma glucose concentration in a healthy population in the absence of chronic diseases. In an oral glucose tolerance test (OGTT) with forty-four healthy male subjects (25.5 ± 4.5 years), the interstitial fluid glucose (ISFG) concentration obtained by a CGM sensor was compared against finger-prick capillary plasma glucose (CPG) concentration at fasting baseline (T0) and 30 (T30), 60 (T60), 90 (T90), and 120 (T120) min post OGTT to investigate differences in measurement accuracy. The overall mean absolute relative difference (MARD) was 12.9% (95%-CI: 11.8-14.0%). Approximately 100% of the ISFG values were within zones A and B in the Consensus Error Grid, indicating clinical accuracy. A paired t-test revealed statistically significant differences between CPG and ISFG at all time points (T0: 97.3 mg/dL vs. 89.7 mg/dL, T30: 159.9 mg/dL vs. 144.3 mg/dL, T60: 134.8 mg/dL vs. 126.2 mg/dL, T90: 113.7 mg/dL vs. 99.3 mg/dL, and T120: 91.8 mg/dL vs. 82.6 mg/dL; p < 0.001) with medium to large effect sizes (d = 0.57-1.02) and with ISFG systematically under-reporting the reference system CPG. CGM sensors provide a convenient and reliable method for monitoring blood glucose in the everyday lives of healthy adults. Nonetheless, their use in clinical settings wherein implications are drawn from CGM readings should be handled carefully.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Humanos , Masculino , Adulto , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/métodos , Automonitorización de la Glucosa Sanguínea/instrumentación , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Prueba de Tolerancia a la Glucosa/métodos , Adulto Joven , Voluntarios Sanos , Líquido Extracelular/química
17.
Sensors (Basel) ; 24(17)2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39275708

RESUMEN

The refractive index (RI) of biological tissues is a fundamental material parameter that characterizes how light interacts with tissues, making accurate measurement of RI crucial for biomedical diagnostics and environmental monitoring. A Janus sensor (JBS) is designed in this paper, and the photonic spin Hall effect (PSHE) is used to detect subtle changes in RI in biological tissues. The asymmetric arrangement of the dielectric layers breaks spatial parity symmetry, resulting in significantly different PSHE displacements during the forward and backward propagation of electromagnetic waves, thereby realizing the Janus effect. The designed JBS can detect the RI range of 1.3~1.55 RIU when electromagnetic waves are incident along the +z-axis, with a sensitivity of 96.29°/refractive index unit (RIU). In the reverse direction, blood glucose concentrations are identified by the JBS, achieving a sensitivity of 18.30°/RIU. Detecting different RI range from forward and backward scales not only overcomes the limitation that single-scale sensors can only detect a single RI range, but also provides new insights and applications for optical biological detection through high-sensitivity, label-free and non-contact detection.


Asunto(s)
Técnicas Biosensibles , Fotones , Refractometría , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Humanos , Glucemia/análisis
18.
J R Soc Interface ; 21(218): 20240279, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39257282

RESUMEN

Bioelectronic bone implants are being widely recognized as a promising technology for highly personalized bone/implant interface sensing and biophysical therapeutic stimulation. Such bioelectronic devices are based on an innovative concept with the ability to be applied to a wide range of implants, including in fixation and prosthetic systems. Recently, biointerface sensing using capacitive patterns was proposed to overcome the limitations of standard imaging technologies and other non-imaging technologies; moreover, electric stimulation using capacitive patterns was proposed to overcome the limitations of non-instrumented implants. We here provide an innovative low-power miniaturized electronic system with ability to provide both therapeutic stimulation and bone/implant interface monitoring using network-architectured capacitive interdigitated patterns. It comprises five modules: sensing, electric stimulation, processing, communication and power management. This technology was validated using in vitro tests: concerning the sensing system, its ability to detect biointerface changes ranging from tiny to severe bone-implant interface changes in target regions was validated; concerning the stimulation system, its ability to significantly enhance bone cells' full differentiation, including matrix maturation and mineralization, was also confirmed. This work provides an impactful contribution and paves the way for the development of the new generation of orthopaedic biodevices.


Asunto(s)
Técnicas Biosensibles , Técnicas Biosensibles/instrumentación , Humanos , Estimulación Eléctrica , Prótesis e Implantes , Interfase Hueso-Implante/fisiología , Animales
19.
Biosens Bioelectron ; 266: 116725, 2024 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-39232434

RESUMEN

Surface-enhanced Raman spectroscopy (SERS) is a powerful method in analytical chemistry, but its application in real-life medical settings has been limited due to technical challenges. In this work, we introduce an innovative approach that is meant to advance the automation of microfluidics SERS to improve reproducibility and label-free quantification of two widely used therapeutic drugs, methotrexate (MTX) and lamotrigine (LTG), in human serum. Our methodology involves a miniaturized solid-phase extraction (µ-SPE) method coupled to a centrifugal microfluidics disc with incorporated SERS substrates (CD-SERS). The CD-SERS platform enables simultaneous controlled sample wetting and accurate SERS mapping. Together with the assay we implemented a machine learning method based on Partial Least Squares Regression (PLSR) for robust data analysis and drug quantification. The results indicate that combining µ-SPE with CD-SERS (µ-SPE to CD-SERS) led to a substantial improvement in the signal-to-noise ratio compared to combining CD-SERS with ultrafiltration or protein precipitation. The PLSR model enabled us to obtain the limit of detection and quantification for MTX as 2.90 and 8.92 µM, respectively, and for LTG as 10.76 and 32.29 µM. We also validated our µ-SPE to CD-SERS method for MTX against HPLC and immunoassay (p-value <0.05), using patient samples undergoing MTX therapy. In addition, we achieved a satisfactory recovery rate (80%) for LTG when quantifying it in patient samples. Our results show the potential of this newly developed approach as a strategy for therapeutic drugs in point-of-care clinical settings and highlight the benefits of automating label-free SERS assays.


Asunto(s)
Lamotrigina , Metotrexato , Extracción en Fase Sólida , Espectrometría Raman , Humanos , Extracción en Fase Sólida/métodos , Lamotrigina/sangre , Espectrometría Raman/métodos , Metotrexato/sangre , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Límite de Detección , Microfluídica/métodos , Diseño de Equipo , Centrifugación
20.
Biosens Bioelectron ; 266: 116713, 2024 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-39232436

RESUMEN

Textile sweat sensors possess immense potential for non-invasive health monitoring. Rapid in-situ sweat capture and prevention of its evaporation are crucial for accurate and stable real-time monitoring. Herein, we introduce a unidirectional, pump-free microfluidic sweat management system to tackle this challenge. A nanofiber sheath layer on micrometer-scale sensing filaments enables this pumpless microfluidic design. Utilizing the capillary effect of the nanofibers allows for the swift capture of sweat, while the differential configuration of the hydrophilic and hydrophobic properties of the sheath and core yarns prevents sweat evaporation. The Laplace pressure difference between the cross-scale fibers facilitates the management system to ultimately expulse sweat. This results in microfluidic control of sweat without the need for external forces, resulting in rapid (<5 s), sensitive (19.8 nA µM-1), and stable (with signal noise and drift suppression) sweat detection. This yarn sensor can be easily integrated into various fabrics, enabling the creation of health monitoring smart garments. The garments maintain good monitoring performance even after 20 washes. This work provides a solution for designing smart yarns for high-precision, stable, and non-invasive health monitoring.


Asunto(s)
Técnicas Biosensibles , Diseño de Equipo , Sudor , Textiles , Sudor/química , Técnicas Biosensibles/instrumentación , Humanos , Dispositivos Electrónicos Vestibles , Nanofibras/química , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/instrumentación , Microfluídica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA