Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 499
Filtrar
1.
Future Cardiol ; 20(5-6): 281-286, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38975696

RESUMEN

One of the most common complications of tricuspid valve replacement is atrioventricular block (AVB), often requiring permanent pacing. The endocardial pacemaker lead, placed in the right ventricle, may sometimes interfere with the implanted prosthesis, causing its early dysfunction and the need for alternative sites of pacing. To the best of our knowledge, we present the first case of a successful combined percutaneous procedure consisting of the implantation of two leads in the coronary sinus for univentricular bifocal pacing and a transcatheter tricuspid valve-in-valve implantation in a young patient with severe dysfunction of the tricuspid bioprosthesis, requiring permanent pacing for a postsurgical complete atrioventricular block.


Tricuspid valve replacement with surgery can often lead to cardiac rhythm disorders requiring a permanent pacemaker. This device may occasionally damage the tricuspid prosthesis. We present the first case of a combined procedure of tricuspid valve replacement and device implantation distant from the prosthesis without the need for a surgical approach in a young patient with severe tricuspid prosthesis malfunctioning and permanent pacing.


Asunto(s)
Cateterismo Cardíaco , Estimulación Cardíaca Artificial , Seno Coronario , Implantación de Prótesis de Válvulas Cardíacas , Válvula Tricúspide , Humanos , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Seno Coronario/cirugía , Cateterismo Cardíaco/métodos , Estimulación Cardíaca Artificial/métodos , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/etiología , Bioprótesis , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico , Marcapaso Artificial , Femenino , Masculino , Adulto
2.
Artículo en Inglés | MEDLINE | ID: mdl-38967498

RESUMEN

In this case report, we describe the surgical treatment of a right coronary sinus aneurysm. A 69-year-old male patient was screened because of palpitations. He was finally diagnosed with an aneurysm of the sinus of Valsalva of the right coronary cusp. According to current aortic guidelines, surgical reconstruction was proposed. The patient underwent a cardiac operation through a median sternotomy under routine cardiopulmonary bypass. After aortic cross-clamping, the aorta was opened and the connection between the aorta and the aneurysm was clearly visualized, underneath the ostium of the right coronary artery. After excision of the right coronary button and the remaining right coronary sinus wall, this sinus was reconstructed with a Dacron graft, with subsequent coronary reimplantation. The postoperative course was uneventful. The patient was discharged on postoperative day 7. A complete sinus reconstruction was preferred over local patching of the defect because of the proximity of the aneurysm sac to the right coronary artery and the fragile, thin aortic tissue just underneath the coronary ostium.


Asunto(s)
Seno Coronario , Humanos , Masculino , Anciano , Seno Coronario/cirugía , Seno Aórtico/cirugía , Aneurisma Coronario/cirugía , Aneurisma Coronario/diagnóstico , Implantación de Prótesis Vascular/métodos , Resultado del Tratamiento , Puente Cardiopulmonar/métodos
5.
J Cardiothorac Surg ; 19(1): 186, 2024 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-38582866

RESUMEN

Coronary artery fistula (CAF) is characterized as a congenital or acquired abnormal communication between a coronary artery and any of the four chambers of the heart (coronary-cameral fistula) or great vessels (coronary arteriovenous fistula) bypassing the capillaries within myocardium. CAF is a rare disease, challenging to diagnose and treat depending on the anatomical location and type of the fistula and accompanying diseases. This study aims to report a case with multiple coronary artery to coronary sinus (CS) fistulas with giant left circumflex artery and multivalvular infective endocarditis.


Asunto(s)
Fístula Arteriovenosa , Enfermedad de la Arteria Coronaria , Seno Coronario , Anomalías de los Vasos Coronarios , Endocarditis Bacteriana , Endocarditis , Humanos , Seno Coronario/diagnóstico por imagen , Seno Coronario/cirugía , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Anomalías de los Vasos Coronarios/cirugía , Endocarditis Bacteriana/complicaciones , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/cirugía , Enfermedad de la Arteria Coronaria/complicaciones , Endocarditis/complicaciones , Fístula Arteriovenosa/diagnóstico por imagen , Fístula Arteriovenosa/cirugía
7.
J Invasive Cardiol ; 36(3)2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38441993

RESUMEN

We report the case of a 79-year-old male patient who benefited from the implantation of a coronary sinus reducer (CSR) (Reducer; Neovasc, Inc.) in the management of typical angina with mild exertion with optimal medical treatment.


Asunto(s)
Seno Coronario , Arteria Pulmonar , Masculino , Humanos , Anciano , Seno Coronario/diagnóstico por imagen , Seno Coronario/cirugía , Angina de Pecho/diagnóstico , Angina de Pecho/etiología , Angina de Pecho/terapia
9.
Int Heart J ; 65(1): 155-158, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38296570

RESUMEN

Unroofed coronary sinus syndrome is a rare congenital cardiac anomaly, involving some anatomical variations. Approximately 60% of patients with unroofed coronary sinus syndrome have a concomitant atrial septal defect, which is termed unroofed coronary sinus atrial septal defect (CSASD). The precise detection of these abnormalities has been usually difficult with conventional echocardiography, mostly due to its small and complex structures. Herein, we report a case with unroofed coronary sinus atrial septal defect, in which preoperative contrast-enhanced computed tomography (CT) was useful in the operative decision making. We successfully repaired the defective roof of the coronary sinus with a bovine patch, while eliminating the inter-atrial shunt. The patient's postoperative course was uneventful with no residual shunt.


Asunto(s)
Seno Coronario , Cardiopatías Congénitas , Defectos del Tabique Interatrial , Anciano , Humanos , Seno Coronario/diagnóstico por imagen , Seno Coronario/cirugía , Seno Coronario/anomalías , Ecocardiografía , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/cirugía , Síndrome , Tomografía Computarizada por Rayos X
10.
J Cardiovasc Electrophysiol ; 35(4): 856-861, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38297424

RESUMEN

INTRODUCTION: With the entry of pulsed-field ablation (PFA) into electrophysiology, new possibilities for ablation of different substrates such as epicardial foci of premature ventricular contractions (PVCs) from coronary venous system (CVS) have been opened. METHODS: This article focuses on a case of a 27-year-old patient with frequent monomorphic PVCs of epicardial origin, treated by radiofrequency ablation, followed by PFA. RESULTS: After unsuccessful focus ablation through CVS with RFA, successful ablations from the same region with PFA were achieved. CONCLUSION: This is the first described case of successful ablation of epicardial PVCs using PFA, which we hope will help in defining indications for this novel technology and enhance quality of treatment for patients with different arrhythmias.


Asunto(s)
Ablación por Catéter , Seno Coronario , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Humanos , Adulto , Seno Coronario/diagnóstico por imagen , Seno Coronario/cirugía , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ventrículos Cardíacos , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía , Complejos Prematuros Ventriculares/etiología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/etiología
11.
EuroIntervention ; 20(3): e216-e223, 2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38214677

RESUMEN

The coronary sinus Reducer (CSR) is an hourglass-shaped device which creates an artificial stenosis in the coronary sinus. Whilst placebo-controlled data show an improvement in angina, these results are unreplicated and are the subject of further confirmatory research. The mechanism of action of this unintuitive therapy is unknown. The Coronary Sinus Reducer Objective Impact on Symptoms, MRI Ischaemia, and Microvascular Resistance (ORBITA-COSMIC) trial is a randomised, placebo-controlled, double-blind trial investigating the efficacy of the CSR. Patients with (i) established epicardial coronary artery disease, (ii) angina on maximally tolerated antianginal medication, (iii) evidence of myocardial ischaemia and (iv) no further options for percutaneous coronary intervention or coronary artery bypass grafting will be enrolled. Upon enrolment, angina and quality-of-life questionnaires, treadmill exercise testing and quantitative stress perfusion cardiac magnetic resonance (CMR) imaging will be performed. Participants will record their symptoms daily on a smartphone application throughout the trial. After a 2-week symptom assessment phase, participants will be randomised in the cardiac catheterisation laboratory to CSR or a placebo procedure. After 6 months of blinded follow-up, all prerandomisation tests will be repeated. A prespecified subgroup will undergo invasive coronary physiology assessment at prerandomisation and follow-up. The primary outcome is stress myocardial blood flow on CMR. Secondary outcomes include angina frequency, quality of life and treadmill exercise time. (ClinicalTrials.gov: NCT04892537).


Asunto(s)
Angina Estable , Enfermedad de la Arteria Coronaria , Seno Coronario , Intervención Coronaria Percutánea , Humanos , Angina Estable/diagnóstico , Calidad de Vida , Seno Coronario/cirugía , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/terapia
14.
Ann Noninvasive Electrocardiol ; 29(1): e13100, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38115789

RESUMEN

BACKGROUND: Posteroseptal accessory pathways (APs) associated with coronary sinus (CS) diverticulum present a rare and challenge for ablation. This study aimed to compare the safety and efficacy of conventional approach and three-dimensional (3D) mapping system in the catheter ablation. METHODS AND RESULTS: This was a retrospective study of all patients (from January 2013 to July 2022) who underwent catheter ablation of posteroseptal AP associated with CS diverticula in our center. Patients who underwent catheter ablation using the traditional fluoroscopy method were included in the conventional method group (n = 13). Patients who underwent catheter ablation using the 3D mapping method were included in the 3D mapping group (n = 11). Clinical characteristics, ablation procedure, and outcomes were recorded and analyzed between the two groups. Out of 669 patients with posteroseptal APs, 24 of them (3.6%) were associated with CS diverticula. All patients in both groups successfully completed the electrophysiological study. In the conventional method group, two patients experienced complications (one patient with pericardial effusion and the other patient with femoral arterial hematoma), and two patients had recurrence. However, no patients suffered from complications or recurrence during follow-up. The procedure time and fluoroscopy time in the conventional method group were significantly longer than those in the 3D mapping method group. CONCLUSIONS: The utilization of 3D mapping led to reduced fluoroscopy time, shorter procedure duration, enhanced acute success rates, and decreased incidence of complications.


Asunto(s)
Fascículo Atrioventricular Accesorio , Ablación por Catéter , Seno Coronario , Divertículo , Cardiopatías Congénitas , Humanos , Seno Coronario/diagnóstico por imagen , Seno Coronario/cirugía , Estudios Retrospectivos , Electrocardiografía/métodos , Fascículo Atrioventricular Accesorio/diagnóstico por imagen , Fascículo Atrioventricular Accesorio/cirugía , Cardiopatías Congénitas/cirugía , Ablación por Catéter/métodos , Divertículo/complicaciones , Divertículo/diagnóstico por imagen , Divertículo/cirugía
15.
Curr Probl Cardiol ; 49(1 Pt C): 102200, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37956917

RESUMEN

In an adult patient, coronary artery fistula involving the circumflex artery (CX) connected to the coronary sinus caused aneurysm of the left main and CX associated with ectasia of the intermediate branch. The patient had posterolateral infarction with severe ischemic mitral regurgitation and moderate tricuspid regurgitation. A rare venous return anomaly was also present. The inferior vena cava, which was interrupted at the level of the liver, continued with the hemiazygos to drain into a persistent left superior vena cava, which in turn drained into the coronary sinus. Surgery included CX closure and mitral and tricuspid repair. The strategy had to be adapted to the anatomy. The fistula was dissected and snared for cardioplegia delivery, and venous return was achieved by cannulation of the superior vena cava and femoral vein. The procedure was uneventful, and 4 years later the patient is asymptomatic.


Asunto(s)
Seno Coronario , Fístula , Cardiopatías Congénitas , Humanos , Adulto , Seno Coronario/cirugía , Vena Cava Superior/anomalías , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Vena Cava Inferior/cirugía , Vena Cava Inferior/anomalías
16.
Ann Cardiol Angeiol (Paris) ; 72(6): 101683, 2023 Dec.
Artículo en Francés | MEDLINE | ID: mdl-37918330

RESUMEN

Coronary sinus Reducer implantation is a percutaneous technique used to treat patients suffering from refractory angina pectoris. The device narrows the coronary sinus, increases the back pressure in the myocardial venous system and forces redistribution of coronary blood flow from less ischemic subepicardium to the more ischemic subendocardium. Multiple clinical studies had proven its efficacy to alleviate myocardial ischemia and related symptoms, and to improve the quality of life of patients with refractory symptomatic chronic coronary artery disease for whom coronary revascularization is deemed unsuitable. This literature review aims to expose the device design, its mechanisms of action, and the clinical data supporting its use. Since November 2021 Reducer's reimbursement has been granted in France by the national health authority. It is the first device to be approved under a newly established reimbursement approval process. A transitional coverage is provided with opportunities for renewal before applying for full-time reimbursement. To fulfill the requirements of the National Commission for Evaluation of Medical Devices and Health Technologies, the French Society of Cardiology has been creating the France Reducer registry. This clinical registry has been collecting data from patients undergoing coronary sinus Reducer implantation regarding their clinical situation, periprocedural information, and one-year follow-up. It is crucial for the future of this emerging therapeutic option in France. To date, 215 patients from 28 centers have been included between June 2022 and September 2023.


Asunto(s)
Seno Coronario , Isquemia Miocárdica , Humanos , Seno Coronario/cirugía , Calidad de Vida , Resultado del Tratamiento , Isquemia Miocárdica/cirugía , Francia , Sistema de Registros
17.
J Interv Card Electrophysiol ; 66(9): 2153-2164, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37864653

RESUMEN

BACKGROUND: Intracoronary sinus ablations have been performed for various arrhythmical substrates. The aim of this study is to report our experience on pediatric patients of the safety and efficacy of ablations in the coronary sinus. METHODS: This is a retrospective study of all patients who underwent ablations in the coronary sinus from October 2013 to October 2021 at a single center. Clinical presentation, type of arrhythmia causing tachycardia, ablation procedure, and outcome were recorded. RESULTS: A total of 27 patients were included in the study. Nineteen (69%) of those followed up received a diagnosis of Wolff-Parkinson-White syndrome (WPW), 4 (15%) were cases of supraventricular tachycardia with concealed accessory pathway (AP), 2 (8%) were cases of focal atrial tachycardia, and 2 (8%) were cases of permanent junctional reciprocating tachycardia. Negative delta wave was noteworthy especially in lead II in 11/19 (58%) cases and coronary sinus diverticulum was detected in the WPW cases. Of those with manifest AP (19 cases), 15 (79%) had a high-risk AP and the AP in all WPW cases was adenosine unresponsive. Radiofrequency (RF) catheter ablation was performed in 25/27 (93%) cases during the procedure, and 16/25 (64%) of these were irrigated RF catheters. No complications were observed in the follow-up, including coronary artery injury. CONCLUSIONS: Catheter ablation of supraventricular tachyarrhythmias can be accomplished effectively and potentially safely within the coronary sinus. Coronary sinus diverticula should be suspected in patients with manifest posteroseptal APs who have a previous failed ablation and typical electrocardiographic signs.


Asunto(s)
Fascículo Atrioventricular Accesorio , Ablación por Catéter , Seno Coronario , Taquicardia Supraventricular , Síndrome de Wolff-Parkinson-White , Humanos , Niño , Seno Coronario/diagnóstico por imagen , Seno Coronario/cirugía , Estudios Retrospectivos , Síndrome de Wolff-Parkinson-White/cirugía , Fascículo Atrioventricular Accesorio/cirugía , Taquicardia Supraventricular/cirugía , Taquicardia/cirugía , Electrocardiografía
18.
BMC Cardiovasc Disord ; 23(1): 516, 2023 10 24.
Artículo en Inglés | MEDLINE | ID: mdl-37875809

RESUMEN

BACKGROUND: The vein of Marshall (VOM) ethanol infusion is increasingly performed in combination with catheter ablation in atrial fibrillation (AF). The cannulation of the VOM can sometimes be challenging. This study aimed to evaluate the double-wire technique in cases of difficult cannulation of the VOM. CASE PRESENTATION: Patients with AF scheduled for combined catheter ablation and VOM ethanol infusion were consecutively enrolled. The procedure was performed via the femoral vein. If the regular cannulation technique with one angioplasty wire failed or took more than 20 min, the double-wire technique using a stabilizing wire and a cannulation wire was performed. The unique technique was used mainly in two scenarios, when the Eustachian ridge was too prominent as a barrier for catheter manipulation or when the VOM ostium was close to the coronary sinus ostium. Of 162 patients scheduled for VOM ethanol infusion, the double-wire technique was applied in 6 (3.7%) patients and led to a 100% successful cannulation rate of the VOM. Of the six patients, two had a prominent Eustachian ridge, and four had a VOM ostium close to the coronary sinus ostium. The mean cannulation time was 33.3 ± 7.3 min. The ethanol infusion was successfully performed in 5 patients. One patient had a collateral circulation in the distal VOM, and ethanol infusion was not performed. CONCLUSIONS: The double-wire technique can facilitate VOM cannulation and ethanol infusion in challenging cases. WORD COUNT: 231.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Seno Coronario , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Cateterismo , Seno Coronario/cirugía , Vasos Coronarios , Etanol/administración & dosificación
19.
J Cardiovasc Electrophysiol ; 34(11): 2398-2402, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37727933

RESUMEN

INTRODUCTION: Herein, we present a rare case of the successful ablation of an accessory pathway (AP) involving the Marshall Bundle (MB) and coronary sinus musculature (CSM) in a 40-year-old man with Wolff-Parkinson-White syndrome. METHODS AND RESULTS: An orthodromic reciprocating tachycardia (ORT) was inducible with the earliest atrial activation site located at the posterolateral mitral annulus. The local conduction and the cycle length of ORT was prolonged by peri-mitral ablation; however, it failed to block the AP. The atrial insertion of the AP was identified by remapping during ORT at the left atrial ridge, which was away from the mitral annulus, where ablation was successful. Together with the electrophysiological findings in CSM potentials, we conclude that the epicardial MB-CSM connection functioned as the AP in this patient. CONCLUSION: The novel variant form of AP comprised of MB and CSM should be noted. The atrial insertion of the MB may be the target of catheter ablation.


Asunto(s)
Fascículo Atrioventricular Accesorio , Ablación por Catéter , Seno Coronario , Taquicardia Reciprocante , Síndrome de Wolff-Parkinson-White , Masculino , Humanos , Adulto , Seno Coronario/diagnóstico por imagen , Seno Coronario/cirugía , Fascículo Atrioventricular Accesorio/cirugía , Taquicardia Reciprocante/diagnóstico , Taquicardia Reciprocante/cirugía , Fascículo Atrioventricular , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/cirugía , Electrocardiografía
20.
J Cardiothorac Surg ; 18(1): 264, 2023 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-37752517

RESUMEN

Aberrant origin of coronary artery is a rare congenital anomaly associated with increased risk of myocardial ischemia and sudden death, with the highest risk lesions being those arising from the opposite sinus of Valsalva. We report a case with an aberrant right coronary artery arising superior to the left coronary cusp, with a slit-like ostium, having an inter-arterial and intramural course through the aortic root, that underwent repositioning of the right coronary artery. We believe such cases warrant surgical correction and reimplantation is a safe, effective and reproducible technique.


Asunto(s)
Enfermedad de la Arteria Coronaria , Seno Coronario , Isquemia Miocárdica , Humanos , Seno Coronario/diagnóstico por imagen , Seno Coronario/cirugía , Corazón
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA