Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.595
Filtrar
1.
IEEE J Transl Eng Health Med ; 12: 613-621, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39247845

RESUMEN

Children worldwide are becoming increasingly inactive, leading to significant wellness challenges. Initial findings from our research team indicate that robots could potentially provide a more effective approach (compared to other age-appropriate toys) for encouraging physical activity in children. However, the basis of this past work relied on either interactions with groups of children (making it challenging to isolate specific factors that influenced activity levels) or a preliminary version of results of the present study (which centered on just a single more exploratory method for assessing child movement). This paper delves into more controlled interactions involving a single robot and a child participant, while also considering observations over an extended period to mitigate the influence of novelty on the study outcomes. We discuss the outcomes of a two-month-long deployment, during which [Formula: see text] participants engaged with our custom robot, GoBot, in weekly sessions. During each session, the children experienced three different conditions: a teleoperated robot mode, a semi-autonomous robot mode, and a control condition in which the robot was present but inactive. Compared to our past related work, the results expanded our findings by confirming with greater clout (based on multiple data streams, including one more robust measure compared to the past related work) that children tended to be more physically active when the robot was active, and interestingly, there were no significant differences between the teleoperated and semi-autonomous modes in terms of our study measures. These insights can inform future applications of assistive robots in child motor interventions, including the guiding of appropriate levels of autonomy for these systems. This study demonstrates that incorporating robotic systems into play environments can boost physical activity in young children, indicating potential implementation in settings crafted to enhance children's physical movement.


Asunto(s)
Ejercicio Físico , Robótica , Humanos , Robótica/instrumentación , Niño , Masculino , Femenino , Promoción de la Salud/métodos , Juego e Implementos de Juego
2.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(4): 664-672, 2024 Aug 25.
Artículo en Chino | MEDLINE | ID: mdl-39218591

RESUMEN

Brain-computer interface (BCI) based on steady-state visual evoked potential (SSVEP) have attracted much attention in the field of intelligent robotics. Traditional SSVEP-based BCI systems mostly use synchronized triggers without identifying whether the user is in the control or non-control state, resulting in a system that lacks autonomous control capability. Therefore, this paper proposed a SSVEP asynchronous state recognition method, which constructs an asynchronous state recognition model by fusing multiple time-frequency domain features of electroencephalographic (EEG) signals and combining with a linear discriminant analysis (LDA) to improve the accuracy of SSVEP asynchronous state recognition. Furthermore, addressing the control needs of disabled individuals in multitasking scenarios, a brain-machine fusion system based on SSVEP-BCI asynchronous cooperative control was developed. This system enabled the collaborative control of wearable manipulator and robotic arm, where the robotic arm acts as a "third hand", offering significant advantages in complex environments. The experimental results showed that using the SSVEP asynchronous control algorithm and brain-computer fusion system proposed in this paper could assist users to complete multitasking cooperative operations. The average accuracy of user intent recognition in online control experiments was 93.0%, which provides a theoretical and practical basis for the practical application of the asynchronous SSVEP-BCI system.


Asunto(s)
Algoritmos , Interfaces Cerebro-Computador , Electroencefalografía , Potenciales Evocados Visuales , Robótica , Potenciales Evocados Visuales/fisiología , Humanos , Robótica/instrumentación , Análisis Discriminante
3.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(4): 833-839, 2024 Aug 25.
Artículo en Chino | MEDLINE | ID: mdl-39218611

RESUMEN

Lower limb exoskeleton rehabilitation robots are used to improve or restore the walking and movement ability of people with lower limb movement disorders. However, the required functions for patients differ based on various diseases. For example, patients with weak muscle strength require power assistance, patients with spinal cord injuries require motion compensation, patients with gait abnormalities require gait correction, and patients with strokes require neural rehabilitation. To design a more targeted lower limb exoskeleton rehabilitation robot for different diseases, this article summarised and compared existing lower limb exoskeleton rehabilitation robots according to their main functions and the characteristics and rehabilitation needs of various lower limb movement disorders. The correlations between the functions of existing devices and diseases were summarised to provide certain references for the development of new lower limb exoskeleton rehabilitation robots.


Asunto(s)
Dispositivo Exoesqueleto , Extremidad Inferior , Robótica , Traumatismos de la Médula Espinal , Rehabilitación de Accidente Cerebrovascular , Humanos , Extremidad Inferior/fisiopatología , Robótica/instrumentación , Traumatismos de la Médula Espinal/rehabilitación , Rehabilitación de Accidente Cerebrovascular/instrumentación , Rehabilitación de Accidente Cerebrovascular/métodos , Marcha/fisiología , Trastornos del Movimiento/rehabilitación , Caminata
4.
J Neuroeng Rehabil ; 21(1): 153, 2024 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-39232831

RESUMEN

BACKGROUND: To overcome the application limitations of functional electrical stimulation (FES), such as fatigue or nonlinear muscle response, the combination of neuroprosthetic systems with robotic devices has been evaluated, resulting in hybrid systems that have promising potential. However, current technology shows a lack of flexibility to adapt to the needs of any application, context or individual. The main objective of this study is the development of a new modular neuroprosthetic system suitable for hybrid FES-robot applications to meet these needs. METHODS: In this study, we conducted an analysis of the requirements for developing hybrid FES-robot systems and reviewed existing literature on similar systems. Building upon these insights, we developed a novel modular neuroprosthetic system tailored for hybrid applications. The system was specifically adapted for gait assistance, and a technological personalization process based on clinical criteria was devised. This process was used to generate different system configurations adjusted to four individuals with spinal cord injury or stroke. The effect of each system configuration on gait kinematic metrics was analyzed by using repeated measures ANOVA or Friedman's test. RESULTS: A modular NP system has been developed that is distinguished by its flexibility, scalability and personalization capabilities. With excellent connection characteristics, it can be effectively integrated with robotic devices. Its 3D design facilitates fitting both as a stand-alone system and in combination with other robotic devices. In addition, it meets rigorous requirements for safe use by incorporating appropriate safety protocols, and features appropriate battery autonomy, weight and dimensions. Different technological configurations adapted to the needs of each patient were obtained, which demonstrated an impact on the kinematic gait pattern comparable to that of other devices reported in the literature. CONCLUSIONS: The system met the identified technical requirements, showcasing advancements compared to systems reported in the literature. In addition, it demonstrated its versatility and capacity to be combined with robotic devices forming hybrids, adapting well to the gait application. Moreover, the personalization procedure proved to be useful in obtaining various system configurations tailored to the diverse needs of individuals.


Asunto(s)
Robótica , Traumatismos de la Médula Espinal , Humanos , Robótica/instrumentación , Robótica/métodos , Traumatismos de la Médula Espinal/rehabilitación , Masculino , Rehabilitación de Accidente Cerebrovascular/instrumentación , Rehabilitación de Accidente Cerebrovascular/métodos , Fenómenos Biomecánicos , Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/métodos , Marcha/fisiología , Persona de Mediana Edad , Femenino , Adulto , Prótesis Neurales , Diseño de Prótesis/métodos
5.
Nat Commun ; 15(1): 7929, 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39256389

RESUMEN

Despite recent advancements, artificial muscles have not yet been able to strike the right balance between exceptional mechanical properties and dexterous actuation abilities that are found in biological systems. Here, we present an artificial magnetic muscle that exhibits multiple remarkable mechanical properties and demonstrates comprehensive actuating performance, surpassing those of biological muscles. This artificial muscle utilizes a composite configuration, integrating a phase-change polymer and ferromagnetic particles, enabling active control over mechanical properties and complex actuating motions through remote laser heating and magnetic field manipulation. Consequently, the magnetic composite muscle can dynamically adjust its stiffness as needed, achieving a switching ratio exceeding 2.7 × 10³. This remarkable adaptability facilitates substantial load-bearing capacity, with specific load capacities of up to 1000 and 3690 for tensile and compressive stresses, respectively. Moreover, it demonstrates reversible extension, contraction, bending, and twisting, with stretchability exceeding 800%. We leverage these distinctive attributes to showcase the versatility of this composite muscle as a soft continuum robotic manipulator. It adeptly executes various programmable responses and performs complex tasks while minimizing mechanical vibrations. Furthermore, we demonstrate that this composite muscle excels across multiple mechanical and actuation aspects compared to existing actuators.


Asunto(s)
Robótica , Robótica/instrumentación , Robótica/métodos , Músculos/fisiología , Músculo Esquelético/fisiología , Humanos , Fenómenos Biomecánicos , Campos Magnéticos , Diseño de Equipo , Resistencia a la Tracción , Estrés Mecánico , Magnetismo
6.
Sci Robot ; 9(94): eadp3260, 2024 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-39259781

RESUMEN

The loss of a hand disrupts the sophisticated neural pathways between the brain and the hand, severely affecting the level of independence of the patient and the ability to carry out daily work and social activities. Recent years have witnessed a rapid evolution of surgical techniques and technologies aimed at restoring dexterous motor functions akin to those of the human hand through bionic solutions, mainly relying on probing of electrical signals from the residual nerves and muscles. Here, we report the clinical implementation of an interface aimed at achieving this goal by exploiting muscle deformation, sensed through passive magnetic implants: the myokinetic interface. One participant with a transradial amputation received an implantation of six permanent magnets in three muscles of the residual limb. A truly self-contained myokinetic prosthetic arm embedding all hardware components and the battery within the prosthetic socket was developed. By retrieving muscle deformation caused by voluntary contraction through magnet localization, we were able to control in real time a dexterous robotic hand following both a direct control strategy and a pattern recognition approach. In just 6 weeks, the participant successfully completed a series of functional tests, achieving scores similar to those achieved when using myoelectric controllers, a standard-of-care solution, with comparable physical and mental workloads. This experience raised conceptual and technical limits of the interface, which nevertheless pave the way for further investigations in a partially unexplored field. This study also demonstrates a viable possibility for intuitively interfacing humans with robotic technologies.


Asunto(s)
Amputados , Miembros Artificiales , Fuerza de la Mano , Imanes , Diseño de Prótesis , Robótica , Humanos , Amputados/rehabilitación , Fuerza de la Mano/fisiología , Robótica/instrumentación , Masculino , Músculo Esquelético/fisiología , Extremidad Superior , Mano/fisiología , Adulto , Electromiografía , Muñones de Amputación/fisiopatología , Contracción Muscular/fisiología , Implantación de Prótesis
7.
Bioinspir Biomim ; 19(5)2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39163889

RESUMEN

Autonomous ocean-exploring vehicles have begun to take advantage of onboard sensor measurements of water properties such as salinity and temperature to locate oceanic features in real time. Such targeted sampling strategies enable more rapid study of ocean environments by actively steering towards areas of high scientific value. Inspired by the ability of aquatic animals to navigate via flow sensing, this work investigates hydrodynamic cues for accomplishing targeted sampling using a palm-sized robotic swimmer. As proof-of-concept analogy for tracking hydrothermal vent plumes in the ocean, the robot is tasked with locating the center of turbulent jet flows in a 13,000-liter water tank using data from onboard pressure sensors. To learn a navigation strategy, we first implemented RL on a simulated version of the robot navigating in proximity to turbulent jets. After training, the RL algorithm discovered an effective strategy for locating the jets by following transverse velocity gradients sensed by pressure sensors located on opposite sides of the robot. When implemented on the physical robot, this gradient following strategy enabled the robot to successfully locate the turbulent plumes at more than twice the rate of random searching. Additionally, we found that navigation performance improved as the distance between the pressure sensors increased, which can inform the design of distributed flow sensors in ocean robots. Our results demonstrate the effectiveness and limits of flow-based navigation for autonomously locating hydrodynamic features of interest.


Asunto(s)
Biomimética , Peces , Hidrodinámica , Océanos y Mares , Robótica , Natación , Robótica/instrumentación , Animales , Peces/fisiología , Biomimética/métodos , Biomimética/instrumentación , Natación/fisiología , Movimientos del Agua , Algoritmos , Diseño de Equipo , Simulación por Computador
8.
Sensors (Basel) ; 24(16)2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39204948

RESUMEN

This study evaluates an innovative control approach to assistive robotics by integrating brain-computer interface (BCI) technology and eye tracking into a shared control system for a mobile augmented reality user interface. Aimed at enhancing the autonomy of individuals with physical disabilities, particularly those with impaired motor function due to conditions such as stroke, the system utilizes BCI to interpret user intentions from electroencephalography signals and eye tracking to identify the object of focus, thus refining control commands. This integration seeks to create a more intuitive and responsive assistive robot control strategy. The real-world usability was evaluated, demonstrating significant potential to improve autonomy for individuals with severe motor impairments. The control system was compared with an eye-tracking-based alternative to identify areas needing improvement. Although BCI achieved an acceptable success rate of 0.83 in the final phase, eye tracking was more effective with a perfect success rate and consistently lower completion times (p<0.001). The user experience responses favored eye tracking in 11 out of 26 questions, with no significant differences in the remaining questions, and subjective fatigue was higher with BCI use (p=0.04). While BCI performance lagged behind eye tracking, the user evaluation supports the validity of our control strategy, showing that it could be deployed in real-world conditions and suggesting a pathway for further advancements.


Asunto(s)
Realidad Aumentada , Interfaces Cerebro-Computador , Electroencefalografía , Tecnología de Seguimiento Ocular , Robótica , Interfaz Usuario-Computador , Humanos , Robótica/métodos , Robótica/instrumentación , Electroencefalografía/métodos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Adulto Joven , Movimientos Oculares/fisiología
9.
Sensors (Basel) ; 24(16)2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39205050

RESUMEN

Using lower limb exoskeletons provides potential advantages in terms of productivity and safety associated with reduced stress. However, complex issues in human-robot interactions are still open, such as the physiological effects of exoskeletons and the impact on the user's subjective experience. In this work, an innovative exoskeleton, the Wearable Walker, is assessed using the EXPERIENCE benchmarking protocol from the EUROBENCH project. The Wearable Walker is a lower-limb exoskeleton that enhances human abilities, such as carrying loads. The device uses a unique control approach called Blend Control that provides smooth assistance torques. It operates two models simultaneously, one in the case in which the left foot is grounded and another for the grounded right foot. These models generate assistive torques combined to provide continuous and smooth overall assistance, preventing any abrupt changes in torque due to model switching. The EXPERIENCE protocol consists of walking on flat ground while gathering physiological signals, such as heart rate, its variability, respiration rate, and galvanic skin response, and completing a questionnaire. The test was performed with five healthy subjects. The scope of the present study is twofold: to evaluate the specific exoskeleton and its current control system to gain insight into possible improvements and to present a case study for a formal and replicable benchmarking of wearable robots.


Asunto(s)
Dispositivo Exoesqueleto , Extremidad Inferior , Caminata , Dispositivos Electrónicos Vestibles , Humanos , Extremidad Inferior/fisiología , Caminata/fisiología , Masculino , Adulto , Robótica/instrumentación , Femenino , Andadores , Diseño de Equipo , Torque
10.
Sci Robot ; 9(93): eads6194, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39196953

RESUMEN

Optically actuated soft microrobotic tools were designed for cell transportation, manipulation, and cell-to-cell interactions.


Asunto(s)
Diseño de Equipo , Robótica , Robótica/instrumentación , Humanos , Animales , Comunicación Celular/fisiología , Micromanipulación/instrumentación , Microtecnología/instrumentación , Movimiento Celular
11.
Sci Robot ; 9(93): eadk8019, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39196952

RESUMEN

Living tissues are still far from being used as practical components in biohybrid robots because of limitations in life span, sensitivity to environmental factors, and stringent culture procedures. Here, we introduce fungal mycelia as an easy-to-use and robust living component in biohybrid robots. We constructed two biohybrid robots that use the electrophysiological activity of living mycelia to control their artificial actuators. The mycelia sense their environment and issue action potential-like spiking voltages as control signals to the motors and valves of the robots that we designed and built. The paper highlights two key innovations: first, a vibration- and electromagnetic interference-shielded mycelium electrical interface that allows for stable, long-term electrophysiological bioelectric recordings during untethered, mobile operation; second, a control architecture for robots inspired by neural central pattern generators, incorporating rhythmic patterns of positive and negative spikes from the living mycelia. We used these signals to control a walking soft robot as well as a wheeled hard one. We also demonstrated the use of mycelia to respond to environmental cues by using ultraviolet light stimulation to augment the robots' gaits.


Asunto(s)
Fenómenos Electrofisiológicos , Micelio , Robótica , Robótica/instrumentación , Micelio/fisiología , Diseño de Equipo , Caminata/fisiología , Potenciales de Acción/fisiología , Rayos Ultravioleta , Marcha/fisiología , Vibración
12.
Sci Robot ; 9(93): eadr9557, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39196951

RESUMEN

The recent movie Atlas misses fundamental robotics advances in self-stabilization and human-robot interaction.


Asunto(s)
Dispositivo Exoesqueleto , Películas Cinematográficas , Robótica , Humanos , Robótica/instrumentación , Robótica/estadística & datos numéricos , Atlas como Asunto , Sistemas Hombre-Máquina
13.
J Neuroeng Rehabil ; 21(1): 134, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39103946

RESUMEN

There are over 5.3 million Americans who face acquired brain injury (ABI)-related disability as well as almost 800,000 who suffer from stroke each year. To improve mobility and quality of life, rehabilitation professionals often focus on walking recovery soon after hospital discharge for ABI. Reduced propulsion capacity (force output of the lower limbs to counteract ground reaction forces) negatively impacts walking ability and complicates recovery during rehabilitation for brain injured people. We describe a method, using backward-directed resistance (BDR) in a robotic-based treadmill device, to allow measurement of maximum walking propulsion force (MWPF) that is not otherwise possible during overground walking assessment. Our objective was to test the construct validity of a maximum walking propulsion force (MWPF) measure that reflects a person's propulsive strength against applied BDR, while walking on a robotic treadmill-based device for participants with acquired brain injury (ABI). Our study enrolled 14 participants with ABI at an in inpatient rehabilitation in Galveston, TX from 8/1/21 - 4/31/22. The range of weight-adjusted MWPF was 2.6-27.1% body weight (%BW), mean 16.5 ± 8.4%BW, reflecting a wide range of propulsive force capability. The strongest correlation with overground tests was between the 6-minute walk test (6-MWT) distance and the MWPF values (r = 0.83, p < 0.001) with moderate correlations between the 10-meter walk tests at comfortable (CWS) and fast speeds (FWS). The Five Times Sit-to-Stand (used as a standard clinical measure of functional lower extremity strength) and MWPF tests were poorly correlated (r = 0.26, p = 0.4). Forward model selection included 6-MWT distance, age, and overground CWS as significant partial predictors of MWPF. We conclude that this novel MWPF measure is a valid representation of maximum propulsive force effort during walking for people post-ABI. Additional research could help determine the impact of interventions designed to increase propulsive force generation during rehabilitation training to improve overground walking performance.


Asunto(s)
Lesiones Encefálicas , Robótica , Caminata , Humanos , Masculino , Caminata/fisiología , Femenino , Persona de Mediana Edad , Lesiones Encefálicas/rehabilitación , Lesiones Encefálicas/fisiopatología , Adulto , Robótica/instrumentación , Prueba de Esfuerzo/métodos , Prueba de Esfuerzo/instrumentación , Anciano , Fenómenos Biomecánicos
14.
Sensors (Basel) ; 24(15)2024 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-39123940

RESUMEN

Physical therapy is often essential for complete recovery after injury. However, a significant population of patients fail to adhere to prescribed exercise regimens. Lack of motivation and inconsistent in-person visits to physical therapy are major contributing factors to suboptimal exercise adherence, slowing the recovery process. With the advancement of virtual reality (VR), researchers have developed remote virtual rehabilitation systems with sensors such as inertial measurement units. A functional garment with an integrated wearable sensor can also be used for real-time sensory feedback in VR-based therapeutic exercise and offers affordable remote rehabilitation to patients. Sensors integrated into wearable garments offer the potential for a quantitative range of motion measurements during VR rehabilitation. In this research, we developed and validated a carbon nanocomposite-coated knit fabric-based sensor worn on a compression sleeve that can be integrated with upper-extremity virtual rehabilitation systems. The sensor was created by coating a commercially available weft knitted fabric consisting of polyester, nylon, and elastane fibers. A thin carbon nanotube composite coating applied to the fibers makes the fabric electrically conductive and functions as a piezoresistive sensor. The nanocomposite sensor, which is soft to the touch and breathable, demonstrated high sensitivity to stretching deformations, with an average gauge factor of ~35 in the warp direction of the fabric sensor. Multiple tests are performed with a Kinarm end point robot to validate the sensor for repeatable response with a change in elbow joint angle. A task was also created in a VR environment and replicated by the Kinarm. The wearable sensor can measure the change in elbow angle with more than 90% accuracy while performing these tasks, and the sensor shows a proportional resistance change with varying joint angles while performing different exercises. The potential use of wearable sensors in at-home virtual therapy/exercise was demonstrated using a Meta Quest 2 VR system with a virtual exercise program to show the potential for at-home measurements.


Asunto(s)
Articulación del Codo , Nanocompuestos , Realidad Virtual , Dispositivos Electrónicos Vestibles , Humanos , Nanocompuestos/química , Articulación del Codo/fisiología , Robótica/instrumentación , Nanotubos de Carbono/química , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Rango del Movimiento Articular/fisiología , Carbono/química
15.
Bioinspir Biomim ; 19(5)2024 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-39146962

RESUMEN

In this paper, the innovative design of a robotic hand with soft jointed structure is carried out and a tendon-driven mechanism, a master-slave motor coordinated drive mechanism, a thumb coupling transmission mechanism and a thumb steering mechanism are proposed. These innovative designs allow for more effective actuation in each finger, enhancing the load capacity of the robotic hand while maintaining key performance indicators such as dexterity and adaptability. A mechanical model of the robotic finger was made to determine the application limitations and load capacity. The robotic hand was then prototyped for a set of experiments. The experimental results showed that the proposed theoretical model were reliable. Also, the fingertip force of the robotic finger could reach up to 10.3 N, and the load force could reach up to 72.8 N. When grasping target objects of different sizes and shapes, the robotic hand was able to perform the various power grasping and precision grasping in the Cutkosky taxonomy. Moreover, the robotic hand had good flexibility and adaptability by means of adjusting the envelope state autonomously.


Asunto(s)
Diseño de Equipo , Fuerza de la Mano , Mano , Robótica , Robótica/instrumentación , Mano/fisiología , Humanos , Fuerza de la Mano/fisiología , Dedos/fisiología , Biomimética/métodos , Tendones/fisiología , Modelos Biológicos
16.
Bioinspir Biomim ; 19(5)2024 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-39151462

RESUMEN

In order to adapt to complex and changing environments, animals have a wide variety of locomotor forms, which has inspired the investigation of their deformation and driving mechanisms. In this paper, we propose a computational design method for muscle-driven soft robots to satisfy desired deformations, aiming to mimic the deformation behavior of muscle-driven animals in nature. In this paper, we generate the ideal muscle-driven layout for the soft robot by inputting an initial shape and a desired shape, so that it can closely achieve the desired deformation. The material point method is utilized to simulate the soft medium so as to achieve the effect of coupling and coordinated deformation of arbitrary shapes. Our method efficiently searches for muscle layouts corresponding to various deformations and realizes the deformation behaviors of a variety of bio-inspired robots, including soft robots such as bionic snakes, frogs, and human faces. Experimental results show that for both the bionic snake and frog soft robots, the overlap of the geometric contour regions between the actual and simulated deformations is more than 90%, which validates the effectiveness of the method. In addition, the global muscle distributions of the bionic snake and human face soft robots during motion are generated and validated by effective simulation.


Asunto(s)
Biomimética , Simulación por Computador , Diseño de Equipo , Robótica , Robótica/instrumentación , Animales , Biomimética/métodos , Humanos , Músculo Esquelético/fisiología , Modelos Biológicos , Anuros/fisiología , Locomoción/fisiología
17.
J Neuroeng Rehabil ; 21(1): 136, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39103888

RESUMEN

BACKGROUND: In the last decade, notable progress in mechatronics paved the way for a new generation of arm prostheses, expanding motor capabilities thanks to their multiple active joints. Yet, the design of control schemes for these advanced devices still poses a challenge, especially with the limited availability of command signals for higher levels of arm impairment. When addressing this challenge, current commercial devices lack versatility and customizing options to be employed as test-beds for developing novel control schemes. As a consequence, researchers resort to using lab-specific experimental apparatuses on which to deploy their innovations, such as virtual reality setups or mock prosthetic devices worn by unimpaired participants. METHODS: To meet this need for a test-bed, we developed the Smart Arm platform, a human-like, multi-articulated robotic arm that can be worn as a trans-humeral arm prosthesis. The design process followed three principles: provide a reprogrammable embedded system allowing in-depth customization of control schemes, favor easy-to-buy parts rather than custom-made components, and guarantee compatibility with industrial standards in prosthetics. RESULTS: The Smart ArM platform includes motorized elbow and wrist joints while being compatible with commercial prosthetic hands. Its software and electronic architecture can be easily adapted to build devices with a wide variety of sensors and actuators. This platform was employed in several experiments studying arm prosthesis control and sensory feedback. We also report our participation in Cybathlon, where our pilot with forearm agenesia successfully drives the Smart Arm prosthesis to perform activities of daily living requiring both strength and dexterity. CONCLUSION: These application scenarios illustrate the versatility and adaptability of the proposed platform, for research purposes as well as outside the lab. The Smart Arm platform offers a test-bed for experimenting with prosthetic control laws and command signals, suitable for running tests in lifelike settings where impaired participants wear it as a prosthetic device. In this way, we aim at bridging a critical gap in the field of upper limb prosthetics: the need for realistic, ecological test conditions to assess the actual benefit of a technological innovation for the end-users.


Asunto(s)
Miembros Artificiales , Diseño de Prótesis , Robótica , Humanos , Diseño de Prótesis/métodos , Robótica/instrumentación , Brazo/fisiología
19.
Nat Commun ; 15(1): 6749, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39117667

RESUMEN

Ingestible electronics have the capacity to transform our ability to effectively diagnose and potentially treat a broad set of conditions. Current applications could be significantly enhanced by addressing poor electrode-tissue contact, lack of navigation, short dwell time, and limited battery life. Here we report the development of an ingestible, battery-free, and tissue-adhering robotic interface (IngRI) for non-invasive and chronic electrostimulation of the gut, which addresses challenges associated with contact, navigation, retention, and powering (C-N-R-P) faced by existing ingestibles. We show that near-field inductive coupling operating near 13.56 MHz was sufficient to power and modulate the IngRI to deliver therapeutically relevant electrostimulation, which can be further enhanced by a bio-inspired, hydrogel-enabled adhesive interface. In swine models, we demonstrated the electrical interaction of IngRI with the gastric mucosa by recording conductive signaling from the subcutaneous space. We further observed changes in plasma ghrelin levels, the "hunger hormone," while IngRI was activated in vivo, demonstrating its clinical potential in regulating appetite and treating other endocrine conditions. The results of this study suggest that concepts inspired by soft and wireless skin-interfacing electronic devices can be applied to ingestible electronics with potential clinical applications for evaluating and treating gastrointestinal conditions.


Asunto(s)
Ghrelina , Animales , Porcinos , Ghrelina/metabolismo , Ghrelina/sangre , Robótica/instrumentación , Mucosa Gástrica/metabolismo , Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/métodos , Femenino , Humanos , Suministros de Energía Eléctrica , Tracto Gastrointestinal , Electrodos
20.
Artículo en Inglés | MEDLINE | ID: mdl-39088505

RESUMEN

Transcutaneous spinal stimulation (TSS) is a promising rehabilitative intervention to restore motor function and coordination for individuals with spinal cord injury (SCI). The effects of TSS are most commonly assessed by evaluating muscle response to stimulation using surface electromyography (sEMG). Given the increasing use of robotic devices to deliver therapy and the emerging potential of hybrid rehabilitation interventions that combine neuromodulation with robotic devices, there is an opportunity to leverage the on-board sensors of the robots to measure kinematic and torque changes of joints in the presence of stimulation. This paper explores the potential for robotic assessment of the effects of TSS delivered to the cervical spinal cord. We used a four degree-of-freedom exoskeleton to measure the torque response of upper limb (UL) joints during stimulation, while simultaneously recording sEMG. We analyzed joint torque and electromyography data generated during TSS delivered over individual sites of the cervical spinal cord in neurologically intact participants. We show that site-specific effects of TSS are manifested not only by modulation of the amplitude of spinally evoked motor potentials in UL muscles, but also by changes in torque generated by individual UL joints. We observed preferential resultant action of proximal muscles and joints with stimulation at the rostral site, and of proximal joints with rostral-lateral stimulation. Robotic assessment can be used to measure the effects of TSS, and could be integrated into complex control algorithms that govern the behavior of hybrid neuromodulation-robotic systems.


Asunto(s)
Electromiografía , Dispositivo Exoesqueleto , Robótica , Traumatismos de la Médula Espinal , Torque , Extremidad Superior , Humanos , Robótica/instrumentación , Masculino , Adulto , Traumatismos de la Médula Espinal/rehabilitación , Femenino , Fenómenos Biomecánicos , Músculo Esquelético/fisiología , Médula Cervical , Voluntarios Sanos , Estimulación de la Médula Espinal/instrumentación , Estimulación de la Médula Espinal/métodos , Adulto Joven , Estimulación Eléctrica Transcutánea del Nervio/instrumentación , Estimulación Eléctrica Transcutánea del Nervio/métodos , Vértebras Cervicales , Algoritmos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA