Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.258
Filtrar
1.
Braz Oral Res ; 38: e078, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39258631

RESUMEN

The aim of this study was to assess the effect of adding arginine at different concentrations to commercial and experimental orthodontic resins on shear bond strength (SBS), as well as on the antimicrobial activity of arginine against S. mutans. Metal brackets were bonded onto the surface of 120 bovine incisors using Transbond, OrthoCem, and an experimental resin (ER), adding 0, 2.5, 5, and 7 wt.% of arginine. The SBS test was performed in deionized water at 37 ºC for 24 h, at 0.5 mm/min. SBS test results were subjected to two-way ANOVA and Tukey's test (α = 0.05). CFU/mL data (antimicrobial assessment) were assessed by Kruskal-Wallis and Dunn's tests (α = 0.05). No statistical difference between the resins was observed in untreated groups (p > 0.05). The addition of arginine at 2.5% (27.7 MPa) and 5% (29.0 MPa) increased the SBS of Transbond when compared (p < 0.05) to OrthoCem (18.5 and 15.6 MPa, respectively) and ER (16.3 and 18.1 MPa, respectively). Arginine at 7% improved the SBS of Transbond (24.1 MPa) and ER (21.0 MPa), which was statistically higher (p < 0.05) than OrthoCem (12.6 MPa). OrthoCem did not show a statistically significant difference at the three concentrations of arginine (p > 0.05). The addition of arginine to resins reduced the count of S. mutans (p < 0.05). As for ER, all concentrations of arginine significantly decreased CFU/mL (p < 0.05). Among commercial resins, only 7% of arginine significantly reduced CFU/mL. The addition of arginine did not interfere with the bond strength and demonstrated antibacterial activity against S. mutans.


Asunto(s)
Arginina , Ensayo de Materiales , Soportes Ortodóncicos , Cementos de Resina , Resistencia al Corte , Streptococcus mutans , Arginina/química , Arginina/farmacología , Animales , Bovinos , Streptococcus mutans/efectos de los fármacos , Análisis de Varianza , Cementos de Resina/química , Factores de Tiempo , Reproducibilidad de los Resultados , Propiedades de Superficie/efectos de los fármacos , Estadísticas no Paramétricas , Valores de Referencia , Recubrimiento Dental Adhesivo/métodos , Bisfenol A Glicidil Metacrilato
2.
Dental Press J Orthod ; 29(4): e242462, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39230115

RESUMEN

OBJECTIVE: The objective of this study was to evaluate the shear bond strength of metal brackets bonded with indirect bonding, under different surface treatment protocols. MATERIAL AND METHODS: 40 bovine teeth were randomly divided into four groups (n = 10), according to the type of surface treatment: G1 = 70% alcohol, G2 = air/water spray, G3 = 100-µm aluminum oxide blasting, G4 = direct boning. After drying, the standard Edgewise central incisor brackets were bonded with light-cured resin. The brackets were moved from the plaster models by means of a transfer tray made with condensation silicone, and bonded to the surface of the enamel with self-curing adhesive. The samples were submitted to shear tests by a universal test machine. Data were analyzed with SPSS 20.0 by the one-way ANOVA test and the Tukey post-test. RESULTS: No statistically significant difference (p=0.174) was observed between the mean forces measured between the group for shear strength values of the groups during the test: G1 (5.33 MPa), G2 (3.52 MPa) and G3 (4.58 MPa). CONCLUSION: The bracket surface treatment protocols presented similarities in shear bond strength test. However, alcohol 70% and oxide blasting presented higher absolute values of resistance than the water group.


Asunto(s)
Recubrimiento Dental Adhesivo , Esmalte Dental , Soportes Ortodóncicos , Resistencia al Corte , Propiedades de Superficie , Animales , Bovinos , Esmalte Dental/efectos de los fármacos , Recubrimiento Dental Adhesivo/métodos , Óxido de Aluminio/química , Análisis del Estrés Dental , Ensayo de Materiales , Cementos de Resina/química , Etanol , Agua/química , Distribución Aleatoria
3.
Biomed Res Int ; 2024: 5394652, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39220997

RESUMEN

Background: Adhesion to zirconia remains a significant dental challenge. This study is aimed at assessing the bond strength of zirconia based on surface treatment with pre or postsintering sandblasting associated with different chemical treatments and resin cements. Methods: Zirconia blocks were divided into 12 experimental groups based on the surface treatment (presintering sandblasting or postsintering sandblasting/tribochemical abrasion treatment), chemical treatment (none, Single Bond Universal, or Signum Zirconia Bond), and choice of cement (Panavia F or RelyX™ U200). The bond strength was measured by shear tests using a universal testing machine. The fracture analysis was performed using stereomicroscopy. Data were analyzed using three-way ANOVA and Tukey's test (α = 5%). Results: Triple and double factor's interactions were not significant (p > 0.05). Regarding the surface treatment factor, the bond strength following postsintering sandblasting treatment associated with tribochemical abrasion (9.15 ± 3.62 MPa) was significantly higher than presintering sandblasting treatment (5.24 ± 3.53 MPa). Concerning the chemical treatment factor, bond strengths were ranked as follows: Signum Zirconia Bond > Single Bond Universal > no treatment. The bond strength of the resin cements did not differ among them. Most fractures (67%) were classified as adhesive, and 32% were categorized as mixed fractures. Conclusion: Surface treatment via postsintering sandblasting combined with tribochemical abrasion demonstrated superior efficacy than in presintering sandblasting. Additionally, chemical treatment with zirconia primer increased the bond strength of zirconia irrespective of the surface physical treatment.


Asunto(s)
Recubrimiento Dental Adhesivo , Ensayo de Materiales , Cementos de Resina , Propiedades de Superficie , Circonio , Circonio/química , Cementos de Resina/química , Recubrimiento Dental Adhesivo/métodos , Resistencia al Corte , Cementos Dentales/química , Humanos
4.
Clin Oral Investig ; 28(8): 465, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39098966

RESUMEN

OBJECTIVE: To evaluate the effect of four different photoactivation protocols (according to "photoactivated faces" - mesial/distal, cervical/incisal or center - and "photoactivation time" - 6-3 s) of a high-power photo activator (Valo Cordless®-Ultradent) on the shear bond strength (SBS) between metal brackets and dental enamel and on the degree of conversion (DC) of an orthodontic resin. MATERIALS AND METHODS: 40 bovine incisor crowns were randomly assigned to 4 groups (n = 10). The brackets were bonded with Transbond XT® resin using 4 protocols according to the "photoactivation protocol" factor (which was subdivided into photoactivated faces and photoactivation time): V3C = 3 s + center; V6C = 6 s + center; V3M3D = 3 s on mesial + 3 s on distal; V3C3I = 3 s on cervical + 3 s on incisal. All the samples were stored for 4 months (water,37ºC) and then subjected to a SBS test (100KgF,1 mm/min). 40 resin discs were made to evaluate the monomer degree of conversion. Data from the SBS and DC were assessed by One-way ANOVA and Tukey's test (5%). Bond failures were analyzed according to the Adhesive Remnant Index (ARI) and evaluated by the Kruskal-Wallis test (5%). RESULTS: There was a statistically significant difference (p = 0.008) in the One-way ANOVA result for SBS values between all groups, but the protocols showed statistically similar results (p ≥ 0.05-Tukey's tests) concerning the photoactivated faces (V6C, V3M3D and V3C3I) and photoactivation time (V3C and V6C) factors individually. There was no statistically significant difference (p ≥ 0.05) in the One-way ANOVA result for DC values. CONCLUSION: The SBS and DC values will vary depending on the protocol applied. CLINICAL RELEVANCE: It is possible to maintain the bracket fixation quality with the use of a high-power LED photo activator associated with a shorter photoactivation time. However, it is assumed that not all types of protocols that might be applied will provide quality bonding, such as V3C, V3M3D and V3C3I, which may - depending on the SBS and DC values - affect the final treatment time, due to brackets debonding, or increase of possibility of damage to dental enamel during bracket removal. Clinical studies are suggested to confirm the hypotheses of this research.


Asunto(s)
Recubrimiento Dental Adhesivo , Esmalte Dental , Análisis del Estrés Dental , Ensayo de Materiales , Soportes Ortodóncicos , Distribución Aleatoria , Cementos de Resina , Resistencia al Corte , Animales , Bovinos , Recubrimiento Dental Adhesivo/métodos , Cementos de Resina/química , Esmalte Dental/química , Propiedades de Superficie , Técnicas In Vitro , Factores de Tiempo , Corona del Diente , Polimerizacion
5.
Meat Sci ; 216: 109579, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38959639

RESUMEN

Fatty acid profile, physicochemical composition, and carcass traits of 32 young Nellore bulls were assessed following the supplementation of Acacia mearnsii extract at levels of 0, 10, 30, and 50 g/kg of total dry matter (DM) in a completely randomized experiment with four treatments and eight replicates. Adding 50 g/kg DM of condensed tannins (CT) from Acacia mearnsii in the bulls' diet reduced DM intake, average daily gain, and meat lipid oxidation (P ≤ 0.05). The pH, centesimal composition, collagen, and meat color indexes of the longissimus muscle were not altered by the addition of Acacia mearnsii (P > 0.05). Cooling loss increased (P = 0.049) linearly. Including Acacia mearnsii in diet reduced the Warner-Bratzler shear force (WBSF, P = 0.018) of longissimus muscle of the bulls. The concentration of C16:0, C17:0, C24:0, t9,10,11,16-18:1, c9t11-18:2, C18:2n-6, C20:4n-6, 20:5n-3, 22:5n-3, and 22:6n-3 in the muscle increased due to the addition of Acacia in the diet (P ≤ 0.05), with the highest muscle concentrations caused by the addition of 10 to 30 g Acacia. c9-18:1 and t16-18:1 reduced linearly. Æ©SFA, Æ©BI, Æ©cis- and Æ©MUFA, Æ©n-3, Æ©n-6, and Æ©PUFA (P ≤ 0.05) quadratically increased at higher concentrations of addition of Acacia, above 30 g/kg DM. It is recommended to include Acacia mearnsii extract up to 30 g/kg total DM in diets for young bulls as it improves CLA, PUFA and TI and reduces lipid oxidation. Acacia mearnsii extract as source of CT at 50 g/kg DM negatively impacted the young bulls performance.


Asunto(s)
Acacia , Alimentación Animal , Dieta , Ácidos Grasos , Músculo Esquelético , Extractos Vegetales , Carne Roja , Animales , Bovinos , Acacia/química , Masculino , Carne Roja/análisis , Músculo Esquelético/química , Alimentación Animal/análisis , Ácidos Grasos/análisis , Dieta/veterinaria , Extractos Vegetales/química , Color , Resistencia al Corte , Suplementos Dietéticos
6.
Biomed Res Int ; 2024: 7457900, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38884017

RESUMEN

Objective: To evaluate the enamel bonding ability and orthodontic adhesive resin degree of conversion using the experimental bracket design. Material and Methods. Thirteen bovine teeth were used in the study. The experimental bracket was modified with a translucent region in the center of its body. After enamel etching, Orthocem orthodontic adhesive (FGM, Joinville, Brazil) was applied on the bracket base for bonding. The groups were divided as follows (n = 10 per group): (1) control (CB) with standard brackets and (2) spot bracket (SB) with experimental brackets featuring a 0.8 mm translucent region at the center using carbide bur. Shear bond strength (SBS) was evaluated after 24 hours in a universal testing machine and adhesive remnant index (ARI). The degree of conversion (DC) was analyzed using Raman spectroscopy (n = 3 per group). Data were then analyzed using Student's t-test and Mann-Whitney statistical methods. Results: The SB group exhibited a higher mean SBS (10.33 MPa) compared to the CB Group (8.77 MPa). However, there was no statistical difference between the groups (p = 0.376). Both SB and CB groups had a mean ARI score of 1. Raman analysis revealed a higher degree of conversion in the SB group (49.3%) compared to the CB group (25.9%). Conclusions: The experimental support showed a higher degree of adhesive conversion, although there was no significant increase in bond strength.


Asunto(s)
Resinas Compuestas , Recubrimiento Dental Adhesivo , Esmalte Dental , Soportes Ortodóncicos , Polimerizacion , Resistencia al Corte , Animales , Bovinos , Recubrimiento Dental Adhesivo/métodos , Esmalte Dental/química , Resinas Compuestas/química , Ensayo de Materiales , Cementos Dentales/química , Cementos de Resina/química
7.
Photobiomodul Photomed Laser Surg ; 42(5): 343-349, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38579157

RESUMEN

Objective: This in vitro study evaluates the shear bond strength (SBS) of yttria-stabilized tetragonal zirconia (Y-TZP) and resin cement after different surface treatments. Materials and methods: Forty-eight ceramic cubes were divided into four groups (n = 12): G1 (control) sandblasting with Al2O3; G2-sandblasting with silica-coated Al2O3 (Rocatec); G3-Rocatec + CO2 laser; and G4-CO2 laser + Rocatec. A metallic primer was applied to the pretreated ceramic. A rubber ring was adapted on the central area, and then, the resin cement was inserted into the matrix and photoactivated. The samples were evaluated regarding surface roughness (Ra), SBS, failure type, and qualitatively with scanning electron microscopy (SEM). The data were analyzed by one-way analysis of variance followed by Tukey's test (p < 0.05). Results: The mean values of Ra (µm) were as follows: G1-4.52a, G2-4.24a,b, G3-4.10a,b, and G4-2.90b and the mean values of SBS (MPa) were as follows: G1-7.84a , G2-4.41b , G3-4.61b and G4-6.14a,b. SEM analyses showed superficial irregularities for all groups, being more prominent for G1. The presence of silica deposits was observed for G2, G3, and G4, but in the last two groups there were some linear areas, promoted by the fusion of silica, due to the thermomechanical action of the CO2 laser. Conclusions: The surface treatment with CO2 laser + Rocatec, using one MDP-based cement, can be an alternative protocol for the adhesion cementation of Y-TZP ceramic since it was as effective as the conventional pretreatment with aluminum oxide sandblasting.


Asunto(s)
Cerámica , Recubrimiento Dental Adhesivo , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Cementos de Resina , Resistencia al Corte , Propiedades de Superficie , Itrio , Circonio , Circonio/química , Itrio/química , Cementos de Resina/química , Cerámica/química , Recubrimiento Dental Adhesivo/métodos , Láseres de Gas , Técnicas In Vitro , Dióxido de Silicio/química , Óxido de Aluminio/química
8.
Oper Dent ; 49(3): 325-335, 2024 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-38632867

RESUMEN

OBJECTIVES: This study aimed to evaluate the impact of various commercial silane brands with varied chemical compositions with or without the application of an adhesive layer on the microshear bond strength and durability of a resin luting agent to lithium disilicate glass ceramic. METHODS AND MATERIALS: Lithium disilicate glass ceramic discs (EMX, IPS e.max Press, Ivoclar Vivadent) measuring 10 mm in diameter and 3 mm in thickness were fabricated (n=240). Surfaces were etched using 5% hydrofluoric acid and randomly assigned to 10 groups based on the commercial brand of silane used (n=24): [RP] RelyX Ceramic Primer (3M ESPE); [PS] Prosil (FGM); [SA] Silano (Angelus); [SM] Silano (Maquira); [SU] Silane (Ultradent); [GL] GLUMA Ceramic Primer (Kulzer); [CB] Ceramic Bond (VOCO); [MB] Monobond N (Ivoclar Vivadent); [CP] Clearfil Ceramic Primer (Kuraray); and [DE] 2-step silane (Dentsply Sirona). Half of the EMXs (n=12) received a thin adhesive layer (+) after the silane and prior to resin luting agent, while the other half (n=12) did not receive an adhesive layer (-). For the microshear bond strength test (µSBS), four light-cured resin luting agent cylinders (1 mm in diameter) were created on each EMX surface. Half of these specimens were tested after 24 hours, while the other half were stored in deionized water for 6 months. The µSBS test was conducted using a universal testing machine (DL 500, EMIC) at a crosshead speed of 1 mm/min until failure. The obtained data underwent statistical analysis using analysis of variance (ANOVA) and the Tukey test (α=0.05). RESULTS: There was significant influence of the silane commercial brand on bond strength. Notably, "universal primers" yielded lower bond strength results compared to "pure" silane solutions. Water storage had a detrimental effect on microshear bond strength for certain silane commercial brands. Additionally, the application of an adhesive layer negatively impacted bond strength results for all silanes. CONCLUSIONS: This study confirms the importance of both silane commercial brand and chemical composition in relation to bond strength of resin luting agents to lithium disilicate glass ceramic. Furthermore, the application of an adhesive layer may have an adverse effect on bond stability over time.


Asunto(s)
Cerámica , Recubrimiento Dental Adhesivo , Porcelana Dental , Análisis del Estrés Dental , Ensayo de Materiales , Cementos de Resina , Resistencia al Corte , Silanos , Porcelana Dental/química , Silanos/química , Cerámica/química , Recubrimiento Dental Adhesivo/métodos , Cementos de Resina/química , Propiedades de Superficie , Cementos Dentales/química , Grabado Ácido Dental/métodos , Humanos
9.
Odovtos (En línea) ; 26(1): 76-85, Jan.-Apr. 2024. tab, graf
Artículo en Inglés | LILACS, SaludCR | ID: biblio-1558620

RESUMEN

Abstract The purpose of this study was to examine the effect of different decontamination agents on the bond strength of saliva-contaminated CAD/CAM blocks and repair composite materials. Two hunderd eighty 3-mm-thick specimens were prepared from four different CAD/CAM materials: Katana Zirconia UTML disc, IPS e.max CAD block, Shofu block, and Vita Enamic block. Each material was divided into seven different subgroups (N=70). Group 1 had a clean surface. The other groups were comprised of the samples, which were contaminated with human saliva: group 2: negative control (non-cleaned); group 3: cleaned with water spray; group 4: cleaned with 70% ethanol; group 5: cleaned with Ivoclean; group 6: cleaned with Katana Cleaner; and group 7: cleaned with phosphoric acid. After the decontamination protocols, the resin composite cylinders were bonded to the CAD/CAM surfaces with a thin layer of dual-cured resin cement. The samples were stored for 24 hours at 37°C in distilled water. Then, they were subjected to a shear bond strength test (SBS). The values were recorded, and fracture types were evaluated using a microscope. Data were analyzed using two-way ANOVA and Tukey's post-hoc test. Generally, all decontaminating agents improved the SBS of composites to Katana Zirconia UTML, IPS e.max, and Vita Enamic materials (p<0.05). However, for Shofu materials, group 6 samples exhibited significantly higher bond strength values as compared with group 2 samples (p=0.026). The highest SBS values were seen in the phosphoric acid-treated group in Katana zirconia materials (26.45 ± 9.38 MPa), whereas the lowest values were seen in group 2 samples in Shofu materials (13.17±3.40 MPa). Each decontaminant agent improved the bond strength of composites to the contaminated CAD/CAM materials. If saliva is not cleaned before adhesive procedure, SBS values may decrease. All decontamination agents can be used safely on zirconia, lithium-disilicate glass-ceramic, hybrid ceramic, and polymer-infiltrated ceramic surfaces.


Resumen El propósito de este estudio fue examinar el efecto de diferentes agentes descontaminantes sobre la fuerza de unión de bloques CAD/CAM contaminados con saliva y materiales compuestos de reparación. Se prepararon doscientas ochenta muestras de 3 mm de espesor a partir de cuatro materiales CAD/CAM diferentes: disco Katana Zirconia UTML, bloque IPS e.max CAD, bloque Shofu y bloque Vita Enamic. Cada material se dividió en siete subgrupos diferentes (N=70). El grupo 1 tenía una superficie limpia. Los otros grupos estaban compuestos por muestras que estaban contaminadas con saliva humana: grupo 2: control negativo (no limpio); grupo 3: limpiado con agua pulverizada; grupo 4: limpiado con etanol al 70%; grupo 5: limpiado con Ivoclean; grupo 6: limpiado con Katana Cleaner; y grupo 7: limpiado con ácido fosfórico. Después de los protocolos de descontaminación, los cilindros de composite de resina se adhirieron a las superficies CAD/CAM con una fina capa de cemento de resina de curado dual. Las muestras se almacenaron durante 24 horas a 37°C en agua destilada. Luego, fueron sometidos a una prueba de resistencia al corte (SBS). Se registraron los valores y se evaluaron los tipos de fracturas utilizando un microscopio. Los datos se analizaron mediante ANOVA de dos factores y la prueba post-hoc de Tukey. En general, todos los agentes descontaminantes mejoraron el SBS de los composites con los materiales Katana Zirconia UTML, IPS e.max y Vita Enamic (p<0,05). Sin embargo, para los materiales Shofu, las muestras del grupo 6 exhibieron valores de fuerza de unión significativamente más altos en comparación con las muestras del grupo 2 (p=0,026). Los valores más altos de SBS se observaron en el grupo tratado con ácido fosfórico en materiales de circonio Katana (26,45 ± 9,38 MPa), mientras que los valores más bajos se observaron en las muestras del grupo 2 en materiales Shofu (13,17 ± 3,40 MPa). Cada agente descontaminante mejoró la fuerza de unión de los composites a los materiales CAD/CAM contaminados. Si no se limpia la saliva antes del procedimiento adhesivo, los valores de SBS pueden disminuir. Todos los agentes descontaminantes se pueden utilizar de forma segura en superficies de circonio, cerámica de vidrio de disilicato de litio, cerámica híbrida y cerámica con infiltraciones de polímeros.


Asunto(s)
Descontaminación/métodos , Diseño Asistido por Computadora , Resistencia al Corte , Limpiadores de Dentadura
10.
Braz Dent J ; 35: e245581, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38537011

RESUMEN

The objective is to evaluate the effect of different surface treatments and storage on the shear strength of ultratranslucent zirconia. 36 blocks of ultra-translucent zirconia were fabricated (7x7x2mm) and sintered. Then, divided into 12 groups according to the "surface treatment" (C -Primer; Al -Sandblasting with Al2O3 + Primer; Si -Silicate + Primer; Gl -Glaze + HF + Primer; Z -Zirlink; Zp -Zirlink + Primer) and "storage" factors (ST-with 150 days/37º and without). After surface treatment, five cylinders (Ø=2mm; h=2.0mm) of resin cement (n=15) were constructed in each ceramic block; at the end, the shear strength test was performed (1mm/min, 50Kgf), and analysis of surface failures. 60 additional samples (2x2x2mm) were made for extras analysis (surface roughness, MEV, and EDS). Bond strength and surface roughness data were statistically evaluated by ANOVA (2 factors/1 factor), Tukey test (5%), and Weibull analysis, respectively. ANOVA (2-way) revealed that all factors were statistically significant for bond strength. The silicatization groups (SiST: 30.47AMPa; Si: 29.21AMPa) showed the highest bond strength values, regardless of storage (Tukey's test). While the groups treated with Zirlink (ZST: 2.76FMPa; Z: 5.27EFMPa) showed the lowest values, just similar to the GlST group (5.14EFMPa). The Weibull modulus (m) showed a statistical difference between groups (p=0.000). ANOVA (1 factor) revealed that the "surface treatment" factor (p=0.0000) was statistically significant for surface roughness. Therefore, the application of Zirlink and Glaze on pre-sintered zirconia did not promote efficient adhesion of the ultratranslucent zirconia to the resin cement, even when associated with a primer containing MDP.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Cementos de Resina/química , Circonio/química , Propiedades de Superficie , Ensayo de Materiales , Cerámica/química , Resistencia al Corte , Análisis del Estrés Dental
11.
J Dent ; 143: 104880, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38336019

RESUMEN

OBJECTIVE: To evaluate the influence of antioxidants (ATX) resveratrol, winter's bark, green tea and yerba mate on the bond strength between bleached enamel and the nanohybrid composite resin. METHODOLOGY: Bovine incisor crowns (n = 132) were randomly divided into 22 groups (n = 6) according to the application times (5, 10, 15, 30, and 60 min) of each antioxidant. Teeth restored without previous bleaching or ATX constituted the non-bleached control group (NB Ctrl) (n = 6), and teeth restored after bleaching and without ATX represented the bleached control group (B Ctrl) (n = 6). The 35 % hydrogen peroxide was applied for 45 min (3 application of 15 min) to the buccal enamel surface. ATX was used after bleaching for the specified time of each group and removed with air-water spray. The enamel was etched with 37 % phosphoric acid (30 s) and rinsed with air-water spray. The adhesive resin was applied to the enamel dry surface. Teeth were restored using 1 mm composite resin increments (10 × 10 × 3 mm) and sectioned in test specimens of 6 mm in length and 1 mm2 in cross-sectional area submitted to microtensile bond strength test (0.5 mm/min). The load (N) at failure was recorded, and the bond strength (σt) was calculated (MPa). The fracture area was analyzed under optical microscopy, and failures were classified as cohesive, mixed, or adhesive. Data was evaluated by Kruskal-Wallis and Dunn tests (p ≤ 0.05). RESULTS: B Ctrl group presented lower σt than NB Ctrl (p < 0.001). Applying resveratrol for 5 or 10 min, winter's bark for 10 or 15 min, green tea for less than 15 min, and yerba mate for 15 min provided similar σt between bleached enamel and nanohybrid composite to the control group. CONCLUSION: Restorative procedures performed immediately after tooth bleaching compromises adhesion. Experimental antioxidants applied to bleached enamel can increase the immediate bond strength of restorations performed directly after bleaching, with similar values to those observed in unbleached enamel. CLINICAL SIGNIFICANCE: This study presents promising results to support the use of antioxidants on the recently bleached enamel to allow adhesive tooth restorations. The immediate bonding obtained using antioxidants was similar to the one achieved in non-bleached enamel in brief application times. Green tea extract and resveratrol were able to restore the bond strength to bleached enamel in a short application time of 5 min. The reduction in the required application time holds the potential to decrease the overall duration of the clinical section, offering clinical advantages and improving the feasibility of using antioxidants on the bleached enamel prior to adhesive procedures.


Asunto(s)
Antiinfecciosos , Recubrimiento Dental Adhesivo , Blanqueamiento de Dientes , Animales , Bovinos , Antioxidantes/farmacología , Antioxidantes/química , Resveratrol/farmacología , Recubrimiento Dental Adhesivo/métodos , Cementos Dentales/farmacología , Cementos Dentales/química , Blanqueamiento de Dientes/métodos , Resinas Compuestas/farmacología , Resinas Compuestas/química , Esmalte Dental , Antiinfecciosos/farmacología , , Agua , Resistencia al Corte
12.
Clin Oral Investig ; 28(2): 149, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38355823

RESUMEN

OBJECTIVE: The study aims to evaluate the shear bond and flexural strength fatigue behavior of yttrium-stabilized zirconia (4YSZ) repaired using different resin composites. MATERIALS AND METHODS: Cylindric specimens of 4YSZ were obtained for the bond strength (Ø = 6 mm, 1.5 mm of thickness) and biaxial flexural strength (Ø = 15 mm, 1 mm of thickness) fatigue tests and divided into 3 groups according to the repair resin composite: EVO (nanohybrid), BULK (bulk-fill), and FLOW (flowable). The zirconia surface was air-abraded with alumina particles, a 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) primer was applied, and the resin composite was build-up over the zirconia. Fatigue shear bond strength and flexural fatigue strength tests were performed (n = 15). One-way ANOVA and Tukey post hoc tests were carried out for both outcomes, besides scanning electron microscopy and finite element analysis. RESULTS: The repair material affected the fatigue shear bond strength of zirconia ceramic. The BULK group (18.9 MPa) depicted higher bond strength values than FLOW (14.8 MPa) (p = 0.04), while EVO (18.0 MPa) showed similar results to both groups. No effect was observed for the mechanical behavior (p = 0.53). The stress distribution was similar for all groups. CONCLUSION: The repair of yttrium-stabilized zirconia (4YSZ) ceramics with bulk-fill resin composites was the best option for high fatigue bond strength. However, the fatigue mechanical performance was similar regardless of the applied repair material. CLINICAL RELEVANCE: The repair of yttrium-stabilized zirconia (4YSZ) monolithic restorations may be performed with nanohybrid and bulk-fill resin composites in order to promote longevity in the treatment.


Asunto(s)
Recubrimiento Dental Adhesivo , Metacrilatos , Recubrimiento Dental Adhesivo/métodos , Propiedades de Superficie , Ensayo de Materiales , Resinas Compuestas/química , Circonio/química , Cerámica/química , Resistencia al Corte , Itrio/química , Cementos de Resina/química , Análisis del Estrés Dental
13.
J Dent ; 145: 104836, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38199325

RESUMEN

OBJECTIVE: To investigate the impact of incorporating the antimicrobial nanomaterial ß-AgVO3 into orthodontic resin, focusing on degree of conversion, surface characteristics, microhardness, adhesion properties, and antimicrobial activity. METHODS: The 3 M Transbond XT resin underwent modification, resulting in three groups (Control, 2.5% addition, 5% addition) with 20 specimens each. Fourier transform infrared spectroscopy assessed monomer conversion. Laser confocal microscopy examined surface roughness, and microhardness was evaluated using Knoop protocols. Shear strength was measured before and after artificial aging on 36 premolar teeth. Microbiological analysis against S. mutans and S. sanguinis was conducted using the agar diffusion method. RESULTS: Degree of conversion remained unaffected by time (P = 0.797), concentration (P = 0.438), or their interaction (P = 0.187). The 5% group exhibited the lowest surface roughness, differing significantly from the control group (P = 0.045). Microhardness showed no significant differences between concentrations (P = 0.740). Shear strength was highest in the control group (P < 0.001). No significant differences were observed in the samples with or without thermocycling (P = 0.759). Microbial analysis revealed concentration-dependent variations, with the 5% group exhibiting the largest inhibition halo (P < 0.001). CONCLUSIONS: Incorporating ß-AgVO3 at 2.5% and 5% concentrations led to significant differences in surface roughness, adhesion, and antimicrobial activity. Overall, resin modification positively impacted degree of conversion, surface characteristics, microhardness, and antimicrobial activity. Further research is warranted to determine clinically optimal concentrations that maximize antimicrobial benefits while minimizing adverse effects on adhesion properties. CLINICAL SIGNIFICANCE: Incorporating ß-AgVO3 into orthodontic resin could improve patient quality of life by prolonging intervention durability and reducing the impact of cariogenic microorganisms. The study's findings also hold promise for the industry, paving the way for the development of new materials with antimicrobial properties for potential applications in the health sector.


Asunto(s)
Ensayo de Materiales , Nanopartículas del Metal , Resistencia al Corte , Plata , Streptococcus mutans , Propiedades de Superficie , Vanadatos , Streptococcus mutans/efectos de los fármacos , Humanos , Plata/química , Plata/farmacología , Vanadatos/química , Vanadatos/farmacología , Nanopartículas del Metal/química , Espectroscopía Infrarroja por Transformada de Fourier , Dureza , Cementos de Resina/química , Streptococcus sanguis/efectos de los fármacos , Soportes Ortodóncicos/microbiología , Microscopía Confocal , Nanoestructuras/química , Adhesión Bacteriana/efectos de los fármacos , Compuestos de Plata/farmacología , Compuestos de Plata/química
14.
Oper Dent ; 49(1): 52-64, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38019213

RESUMEN

The present study aimed to evaluate the influence of application mode on the short-term microshear bond strength longevity of self-etching and universal adhesive systems to enamel, the failure mode, and the resulting enamel surface micromorphology. Ninety enamel surfaces were obtained from sound third molars, planed, and randomly assigned to nine groups, according to the application mode and the adhesive system (n=10). There were three primer application modes: according to the manufacturer's recommended application time (control), using double the application time recommended for the primer and selective enamel etching. The adhesive systems used were: Clearfil SE Bond (Kuraray), FL-Bond II (SHOFU), and Futurabond U (Voco). At least two resin-bonded composite cylinders (Grandioso Light Flow, Voco) were placed on each enamel surface, and then evaluated for microshear bond strength at 24 hours and 180 days of storage in solution body fluid (SBF) at pH 7.4. Failure modes were evaluated with a stereoscopic microscope at 20× magnification. A micromorphological analysis of the enamel surface was performed under a scanning electron microscope at 5000× magnification before and after the treatments. Mixed models for repeated measures over time showed significant interaction among application modes, adhesive systems, and time periods (p=0.0331). The bond strength of FL-Bond II adhesive to enamel observed after performing selective enamel etching was significantly higher than that observed after applying the control treatment (p=0.0010) at both 24 hours and 180 days. However, no significant difference was observed between the application of this same adhesive at double the time recommended by the manufacturer and the other two application modes (p>0.05). There was also no significant difference in the microshear bond strength for the enamel treatments applied using Clearfil SE Bond and Futurabond U (p>0.05). A significant reduction in bond strength to enamel was observed at the 180-day storage time for all the adhesive systems when selective enamel etching was performed (p<0.0001). No significant association was observed between the adhesive system failure mode and the enamel treatments (p=0.1402 and p=0.7590 for 24 hours and 180 days, respectively). The most prevalent failure was the adhesive type.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos Dentales , Cementos Dentales/química , Recubrimiento Dental Adhesivo/métodos , Grabado Ácido Dental/métodos , Resinas Compuestas/química , Cementos de Resina/uso terapéutico , Cementos de Resina/química , Esmalte Dental , Ensayo de Materiales , Resistencia al Corte , Recubrimientos Dentinarios/química
15.
Pesqui. bras. odontopediatria clín. integr ; 24: e230017, 2024. tab, graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1564859

RESUMEN

ABSTRACT Objective: To assess the effect of Casein Phosphopeptide-Amorphous Calcium Phosphate (ACP) containing bonding agents on dentin shear bond strength and remineralization potential. Material and Methods: This in vitro study evaluated 45 extracted human premolars. The teeth were decoronated, and the tooth crown was split into buccal and lingual halves. The specimens were then flat-grounded by a 180-grit abrasive. The specimens were then randomized into three groups (n=15). Adper Scotchbond Multi-Purpose (SBMP) primer and adhesive were used for bonding in the control group. ACP in 10wt% and 20wt% concentrations was added to SBMP adhesive and used in groups 2 and 3, respectively. After the application of primer and adhesive and light-curing them for 10 s, a transparent silicon cylinder was placed on a dentin surface and cured for 10 s; then, the cylinder was filled with composite resin and was cured for the 40s from each side. The specimens underwent 3000 thermal cycles, and a universal testing machine measured the SBS. To assess the remineralization quality, a total of 6 dentin samples (2 specimens for group) were prepared and underwent X-ray diffraction, attenuated total reflection Fourier-transform infrared spectroscopy, and scanning electron microscopy-energy dispersive X-ray analysis. One-way analysis of variance was used to analyze the data. The level of p<0.05 was considered significant. Results: No significant difference in dentin shear bond strength was noted between the groups (p>0.05) - the addition of ACP to SBMP adhesive enhanced dentin remineralization. Increasing the ACP concentration from 10% to 20% increased the formation of hydroxyapatite. Conclusion: Adding amorphous calcium phosphate confers remineralizing property to SBMP adhesive without compromising its shear bond strength to dentin.


Asunto(s)
Humanos , Fosfopéptidos/química , Remineralización Dental , Cafeína/farmacología , Resinas Compuestas/química , Cementos Dentales/química , Distribución de Chi-Cuadrado , Análisis de Varianza , Estadísticas no Paramétricas , Resistencia al Corte
16.
Braz. dent. sci ; 27(2): 1-10, 2024. ilus, tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1563105

RESUMEN

Objective: To evaluate the effect of saliva contamination and different decontamination protocols on the microshear bond strength of a universal adhesive to dentin. Material and Methods: 84 bovine teeth were divided into three groups according to bonding stage at which salivary contamination occurred; before curing of the adhesive, after curing of the adhesive, and a control group with no salivary contamination. Each group was further subdivided into four subgroups according to the decontamination protocol used (n=7): no decontamination protocol, rinsing then reapplication of the adhesive, grinding with sandpaper silicon carbide grit 600 then reapplication of the adhesive and finally ethanol application then reapplication of the adhesive. Specimens were tested in micro-shear mode. Results: All the decontamination protocols used in this study to reverse effect of salivary contamination before curing significantly improved the bond strength to contaminated dentin (p<0.001). Meanwhile, after curing, ethanol decontamination protocol recorded highest bond strength followed by rinsing and grinding compared to no decontamination (p<0.001). Conclusion: Saliva contamination led to significant deterioration in the bond strength regardless of the bonding stage at which saliva contamination occurred. All decontamination protocols improved the immediate microshear bond strength when contamination occurred before curing of the adhesive, while ethanol seemed to be the most effective both before curing and after curing (AU)


Objetivo: Avaliar o efeito da contaminação por saliva e de diferentes protocolos de descontaminação na resistência de união ao microcisalhamento de um adesivo universal à dentina. Material e Métodos: 84 dentes bovinos foram divididos em três grupos de acordo com o passo operatório do protocolo adesivo em que ocorreu a contaminação por saliva: antes da polimerização do adesivo, ou após a polimerização do adesivo e um grupo controle sem contaminação por saliva. Cada grupo foi subdividido em quatro subgrupos de acordo com o protocolo de descontaminação utilizado (n=7): sem protocolo de descontaminação; lavagem seguida da reaplicação do adesivo; lixar a região com lixa de carbeto de silício de granulação 600 e reaplicar o adesivo; aplicar etanol e reaplicar o adesivo. Os espécimes foram testados no modo de micro-cisalhamento. Resultados: Todos os protocolos de descontaminação utilizados neste estudo em busca de reverter o efeito da contaminação do adesivo por saliva melhoraram significativamente a resistência de união à dentina contaminada (p<0,001). Enquanto isso, após a polimerização, o protocolo de descontaminação com etanol resultou na maior resistência de união, seguido pela lavagem, e depois pelo lixamento, em comparação com nenhum protocolo de descontaminação (p<0,001). Conclusão: A contaminação por saliva levou a uma deterioração significativa na resistência de união, independentemente do passo operatório do protocolo adesivo em que ocorreu a contaminação por saliva. Todos os protocolos de descontaminação melhoraram a resistência de união ao microcisalhamento imediato quando a contaminação ocorreu antes da polimerização do adesivo, enquanto o etanol pareceu ser o protocolo mais eficaz nos dois tipos de contaminação (antes e depois da polimerização).


Asunto(s)
Saliva , Descontaminación , Recubrimientos Dentinarios , Resistencia al Corte , Etanol
17.
Eur J Prosthodont Restor Dent ; 31(4): 332-345, 2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-37721539

RESUMEN

INTRODUCTION: Pit and fissure sealants are effective in preventing caries disease, however, they may present flaws that damage the physical barrier leading to treatment failure. OBJECTIVE: To answer the question ''Do pit and fissure sealants present good adhering to the dental structure when analyzed by their resistance to shear/microshear?". METHODS: This systematic review followed the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) and was recorded in Open Science Framework. Embase, PubMed, SCOPUS, and Web of Science databases were used for the search strategy. The articles were selected according to the eligibility criteria. The risk of bias was performed with the adaptation of the quasi-experimental studies tool by Joanna Briggs Institute (JBI). RESULTS: 1245 studies were found in the databases when applying the search strategy, after removal of duplicates 881 were evaluated and 44 were selected. After applying the JBI tool, 30 studies presented low risk and 15 moderate risk of bias. Meta-analysis was not possible to performed due to the heterogeneity of the studies. CONCLUSION: The adhesion is dependent on the application protocol, and among the protocols evaluated, conditioning with 37% phosphoric acid for 60 seconds and contamination of the substrate, as these can affect sealant adhesion.


Asunto(s)
Caries Dental , Selladores de Fosas y Fisuras , Humanos , Resistencia al Corte
18.
Phys Rev E ; 107(5): L052901, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37328967

RESUMEN

Granular materials are used in several fields and in a wide variety of processes. An important feature of these materials is the diversity of grain sizes, commonly referred to as polydispersity. When granular materials are sheared, they exhibit a predominant small elastic range. Then, the material yields, with or without a peak shear strength depending on the initial density. Finally, the material reaches a stationary state, in which it deforms at a constant shear stress, which can be linked to the residual friction angle ϕ_{r}. However, the role of polydispersity on the shear strength of granular materials is still a matter of debate. In particular, a series of investigations have proved, using numerical simulations, that ϕ_{r} is independent of polydispersity. This counterintuitive observation remains elusive to experimentalists, and especially for some technical communities that use ϕ_{r} as a design parameter (e.g., the soil mechanics community). In this Letter, we studied experimentally the effects of polydispersity on ϕ_{r}. In order to do so, we built samples of ceramic beads and then sheared these samples in a triaxial apparatus. We varied polydispersity, building monodisperse, bidisperse, and polydisperse granular samples; this allowed us to study the effects of grain size, size span, and grain size distribution on ϕ_{r}. We find that ϕ_{r} is indeed independent of polydispersity, confirming the previous findings achieved through numerical simulations. Our work fairly closes the gap of knowledge between experiments and simulations.


Asunto(s)
Resistencia al Corte , Estrés Mecánico , Fricción
19.
Dent Mater ; 39(7): 665-668, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37225538

RESUMEN

OBJECTIVES: To analyze the influence of different concentrations of 10-MDP and GPDM used, combined or not, on the bonding to zirconia. METHODS: Specimens of zirconia and a resin-composite (7 mm length, 1 mm width, and 1 mm thick) were obtained. The experimental groups were obtained according to the functional monomer (10-MDP and GPDM) and the concentrations (3 %, 5 %, and 8 %). For the groups with combined 10-MDP and GPDM, the agents were used with a proportion of 50 %/50 % wt until reaching the 3 %, 5 % and 8 % concentrations. All monomers were diluted in ethanol to obtain the primers. Two control groups were established: ethanol (negative control) and a commercial reference Monobond N (positive control). The zirconia surface treatment was performed with the primer application followed by the bonding to a resin-composite sample with a light-curing resin cement. Twenty-four hours after the adhesive procedure, a microtensile test was performed and the failure pattern of each sample was analysed with a stereoscopic magnifying glass. Data were analysed by a two-way ANOVA and Dunnet test. RESULTS: All experimental primers presented a higher bond strength than the negative control (ethanol). Excepting the 8 % GPDM primer, all groups presented statistically similar bond strength compared to the positive control, with a predominance of adhesive failure. SIGNIFICANCE: 10-MDP, GPDM, and the combination of both for the concentrations tested promote an effective chemical bonding to zirconia. However, using 10-MDP and GPDM in the same primer has no synergistic effect.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos Dentales , Cementos Dentales/química , Recubrimiento Dental Adhesivo/métodos , Cementos de Resina/química , Circonio/química , Metacrilatos/química , Resinas Compuestas , Ensayo de Materiales , Propiedades de Superficie , Resistencia al Corte , Análisis del Estrés Dental
20.
Oper Dent ; 48(2): E48-E59, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36928743

RESUMEN

OBJECTIVE: The objective of this study was to compare the effect of solvent in universal adhesives (UA) and the application of an extra layer of hydrophobic bonding resin on enamel shear bond strengths (SBS). METHODS AND MATERIALS: Crowns of 224 bovine mandibular incisors were embedded in acrylic resin, wet-polished up to 600-grit silicon carbide paper and assigned to 3 UAs with different solvents (n=32): ethanol-based UA (ADU, AdheSE Universal, Ivoclar Vivadent); isopropanol-based UA (PBU, Prime&Bond Universal, Dentsply Sirona); and acetone-based UA (OPT, OptiBond Universal, Kerr Co). The same UAs were also applied with an extra layer of a hydrophobic bonding resin (HLB, Heliobond, Ivoclar Vivadent): ADU + HLB; PBU + HLB; and OPT + HLB. HLB alone was used as control. Enamel was etched with 37.5% H3PO4 (Kerr Gel Etchant, Kerr Co) for 15 seconds, rinsed with water, and air dried. UAs were applied according to the respective manufacturer's instructions. After adhesive application, composite cylinders (Filtek Z250, 3M Oral Care) were built up and light-cured (40 seconds/increment, 40 J/cm2) keeping the light tip in contact with the mold. Specimens were stored in water for 24 hours (24H) or for 6 months (6M). A knife-edged metallic rod (Ø=2.8-mm semicircular notch) loaded the composite cylinders until fracture. Mode of failure was analyzed with optical microscopy (40×). Statistics included twoway analysis of variance (ANOVA; adhesive strategy and water storage) and Tukey honestly significant difference (HSD) post hoc test (α=95%). RESULTS: Mean enamel SBS ranged from 3.6 (±2.2) MPa (HLB/6M) to 24.7 (±7.1) MPa (ADU + HLB/6M). ANOVA revealed significant differences for adhesive strategy (p≤0.001) but no significant differences for water storage (p>0.05). All UAs resulted in similar mean enamel SBS with or without an extra layer of HLB at 24H. After 6M, only ADU resulted in higher enamel SBS when an extra layer of HLB was applied. All UAs resulted in higher mean enamel SBS than HLB (control). Most failures were adhesive exception for PBU/HLB/6M, which had mostly mixed failures. CONCLUSIONS: UAs resulted in statistically higher enamel SBS than the nonsolvated hydrophobic bonding resin (control), regardless of the solvent in their composition. Application of an extra layer of hydrophobic bonding resin over UAs did not improve mean enamel SBS for isopropanol- and acetone-based UAs but did improve mean enamel SBS for the ethanol-based UA after 6M. Resin composite bonding to enamel using a hydrophobic bonding resin alone is not recommended.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos Dentales , Animales , Bovinos , Cementos Dentales/uso terapéutico , Acetona , Recubrimientos Dentinarios/química , 2-Propanol , Recubrimiento Dental Adhesivo/métodos , Resinas Compuestas/uso terapéutico , Resinas Compuestas/química , Cementos de Resina/uso terapéutico , Cementos de Resina/química , Solventes , Esmalte Dental , Agua/química , Etanol , Ensayo de Materiales , Resistencia al Corte , Dentina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA