Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Intervalo de año de publicación
1.
Braz. arch. biol. technol ; Braz. arch. biol. technol;50(1): 153-159, Jan. 2007. graf, ilus
Artículo en Inglés | LILACS | ID: lil-452560

RESUMEN

The aim of this work was to study herbicide degradation through selected microorganisms from humus and soil subjected to different plantation systems. The following bacterial species were identified: Klebsiella pneumoniae pneumoniae GC s.B strain 1, Pseudomonas alcaligenes, Enterobacter aerogenes GC s.A and Klebsiella pneumoniae pneumoniae GC s.B strain 2. Growth studies yet suggested the possibility of a very long lag phase. Although, culture with the herbicide presented biofilm formation and there were color changes in the herbicide that could have interfered with the espectrophotometry readings. After 5 days of incubation at 35°C, the difference in the concentration of herbicide was 14.42 percent on average and after 10 days, 35.01 percent.


Os herbicidas representam 65 por cento do consumo geral, sendo que o S-Metolachlor é um dos mais utilizados e está trazendo preocupações ambientais. Objetivamos detectar a degradação do S-Metolachlor por microorganismos de solos sob plantio. Foram identificadas as espécies bacterianas: Klebsiella pneumoniae pneumoniae GC s.B linhagem 1, Pseudomonas alcaligenes, Enterobacter aerogenes GC s.A e Klebsiella pneumoniae pneumoniae GC s.B linhagem 2. Resultados da curva de crescimento por espectrofotometria não permitiram definir diferentes fases, levando a pensar em uma fase Lag longa. Frascos de cultura demonstraram a formação de biofilme, provocando mudança na cor do herbicida, interferindo na leitura do crescimento. É possível a existência de fase Log, mas não detectável pelo método. Após 5 dias de incubação a 35°C, a diferença média de concentração do S-Metolachlor foi de 14.42 por cento, e em 10 dias, 35.01 por cento. Observou-se o aparecimento de um halo em volta das colônias, o que corrobora a hipótese de degradação microbiana do herbicida.


Asunto(s)
Biodegradación Ambiental , Biopelículas , Enterobacter aerogenes , Herbicidas , Klebsiella pneumoniae , Pseudomonas alcaligenes
2.
Arq Bras Oftalmol ; 69(3): 327-31, 2006.
Artículo en Portugués | MEDLINE | ID: mdl-16936954

RESUMEN

PURPOSE: To quantify and compare the in vitro adherence of Staphylococcus epidermidis and Pseudomonas alcaligenes to different intraocular lenses (IOLs). METHODS: Fourteen intraocular lenses were used in the experiment. Four of polymethylmethacrylate (PMMA), four of silicone, four of hydrogel and two of acrylic. Eight intraocular lenses were placed in eight test tubes containing 4 ml of Pseudomonas alcaligenes suspension, and six intraocular lenses were placed in six test tubes containing 4 ml of Staphylococcus epidermidis suspension. The bacterial suspension used for adherence tests was 10(8) colony-forming units per milliliter (CFU/mL) which corresponds to 0.5 in the scale of McFarland. The lenses were incubated at 37 degrees for two hours. After this, intraocular lenses were removed from the test tubes and dried twice with the use of distilled and sterile water. The material was spread on blood-agar for cultivation at 35-37 degrees C and was evaluated every 24 hours up to 72 hours. In the samples where there was bacterial growth, the colonies were counted using the conventional laboratory methods. All assays were performed in duplicate. RESULTS: Adherence of Staphylococcus epidermidis to PMMA intraocular lenses was lower than to hydrogel and silicone intraocular lenses. Adherence of Pseudomonas alcaligenes to hydrogel intraocular lenses was lower than to PMMA, acrylic and silicone intraocular lenses. CONCLUSIONS: Results suggest that in vitro adherence of Staphylococcus epidermidis and Pseudomonas alcaligenes to intraocular lenses is influenced by type of material of the lens and by microorganism species. Bacterial adherence may play a role in the pathogenesis of some forms of endophthalmitis after cataract surgery. More in vitro and clinical studies are necessary to elucidate the mechanisms by which Staphylococcus epidermidis and Pseudomonas alcaligenes cause endophthalmitis.


Asunto(s)
Adhesión Bacteriana/fisiología , Lentes Intraoculares/microbiología , Pseudomonas alcaligenes/crecimiento & desarrollo , Staphylococcus epidermidis/crecimiento & desarrollo , Recuento de Colonia Microbiana
3.
Arq. bras. oftalmol ; Arq. bras. oftalmol;69(3): 327-331, maio-jun. 2006. ilus, graf
Artículo en Portugués | LILACS | ID: lil-433795

RESUMEN

OBJETIVO: Quantificar e comparar a aderência in vitro das bactérias Staphylococcus epidermidis e Pseudomonas alcaligenes em diferentes tipos de lentes intra-oculares (LIOs). MÉTODOS: Quatorze lentes intra-oculares foram usadas no experimento. Quatro de polimetilmetacrilato (PMMA), quatro de silicone, quatro de hidrogel e duas de acrílico. Oito lentes intra-oculares foram colocadas em oito tubos de ensaio contendo 4 ml de suspensão de Pseudomonas alcaligenes, e seis lentes intra-oculares foram colocadas em seis tubos de ensaio contendo 4 ml de suspensão de Staphylococcus epidermidis. A concentração do caldo utilizada para o teste de aderência foi de 10(8) unidades formadoras de colônias por mililitro (CFU/mL) que corresponde a 0,5 na escala de McFarland. As lentes foram incubadas a 37° por duas horas. Após, foram removidas dos caldos e enxaguadas em água destilada estéril por duas vezes. As lentes foram cultivadas em placas de ágar-sangue a 35-37° e evaliadas a cada 24h por um período de 72h. Nas amostras que tiveram crescimento bacteriano, foram contadas as colônias utilizando os métodos convencionais de laboratório. Todos os ensaios foram executados em duplicata. RESULTADOS: A aderência do Staphylococcus epidermidis nas lentes de PMMA foi menor se comparada com as de silicone e de hidrogel. A aderência daPseudomonas alcaligenes nas lentes de hidrogel foi menor se comparada com as de silicone, PMMA e acrílico. CONCLUSÃO: Os resultados sugerem que a aderência do Staphylococcus epidermidis e da Pseudomonas alcaligenes nas lentes intra-oculares é influenciada pelo tipo de material da lente e pela espécie do microorganismo. A aderência bacteriana pode ter papel importante na patogenicidade da endoftalmite pós-cirurgia de catarata.


Asunto(s)
Adhesión Bacteriana/fisiología , Lentes Intraoculares/microbiología , Pseudomonas alcaligenes/crecimiento & desarrollo , Staphylococcus epidermidis/crecimiento & desarrollo , Recuento de Colonia Microbiana
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA