Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.793
Filtrar
1.
Medicine (Baltimore) ; 103(36): e39618, 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39252307

RESUMEN

To investigate the safety of pancreatic body suspension (PBS) technique in laparoscopic splenectomy combined with pericardial devascularization for patients. A retrospective study inclusive of 16 patients who underwent laparoscopic splenectomy combined with pericardial devascularization from 2017 to 2022 was performed. A total of 5 patients underwent PBS technique and 11 underwent the traditional technique. There was no significant difference in age, sex, body mass index (BMI), preoperative serum white cell count (WBC), platelets (PLT), hemoglobin (HB), albumin (ALB), prothrombin time (PT), total bilirubin (TBIL), or spleen size between the 2 groups (P > .05). In the PBS group, the operation time was 280 minutes. The estimated intraoperative blood loss (EBL) was 250 mL. The mean postoperative hospitalization length was 11.2 days. There was no conversion to an open procedure or postoperative bleeding. In the traditional method group, the mean operation time was 240.91 minutes. The EBL was 290.91 mL. There were 2 cases of conversion to open, 3 cases of postoperative bleeding, and 1 reoperation. The incidence of postoperative short-term complications (postoperative bleeding, reoperation) was significantly higher in the traditional method group than in the PBS group (36.36% vs 0%, P = .034). PBS technique improved the safety of laparoscopic splenectomy combined with pericardial dissection and is worthy of clinical promotion.


Asunto(s)
Laparoscopía , Tempo Operativo , Pericardio , Esplenectomía , Humanos , Esplenectomía/métodos , Esplenectomía/efectos adversos , Masculino , Femenino , Laparoscopía/métodos , Laparoscopía/efectos adversos , Estudios Retrospectivos , Persona de Mediana Edad , Adulto , Pericardio/trasplante , Pericardio/cirugía , Pérdida de Sangre Quirúrgica/estadística & datos numéricos , Páncreas/cirugía , Páncreas/irrigación sanguínea , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Hemorragia Posoperatoria/epidemiología , Hemorragia Posoperatoria/etiología , Tiempo de Internación/estadística & datos numéricos
2.
Artículo en Inglés | MEDLINE | ID: mdl-39258523

RESUMEN

In treating aortic root diseases, the Bentall procedure offers reliable and stable results. However, it requires a prosthetic valved conduit, which presents inherent challenges due to the need for anticoagulation. The Ozaki procedure, which uses pericardium for aortic valve neocuspidization, is an alternative to prosthetic valves and does not need anticoagulation. We developed a surgical technique combining the Bentall and Ozaki procedures to treat patients with aortic root disease, which we describe in this article. Because the risk of bleeding due to anticoagulation after prosthetic valve replacement was a concern, we combined the Bentall and Ozaki procedures with a graft conduit using bovine pericardial patch neocuspidization. Postoperative echocardiography showed a competent aortic valve with no regurgitation. We believe that this novel procedure provides hope for a more adaptable and patient-friendly option.


Asunto(s)
Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Bovinos , Pericardio/trasplante , Masculino , Implantación de Prótesis Vascular/métodos , Bioprótesis/efectos adversos , Femenino , Resultado del Tratamiento , Animales , Persona de Mediana Edad
3.
Artículo en Inglés | MEDLINE | ID: mdl-39198196

RESUMEN

PURPOSE: Aortic valve neocuspidization (AVNeo) is a relatively recent advancement in surgical AV replacement. Data on its performance beyond the short term are limited. We assessed the mid-term outcomes in patients undergoing AVNeo, focusing on feasibility, perioperative details, and its role in AV pathology treatment. METHODS: Sixty-five consecutive patients underwent AVNeo between December 2016 and February 2018. Clinical data were prospectively collected and retrospectively analyzed. Tricuspid reconstruction with autologous pericardium was performed in all cases. Echocardiographic follow-up was conducted post-discharge, at 6 and 12 months, and annually thereafter. RESULTS: The mean age was 62.6 ± 18.7 years. AVNeo was feasible in all cases. Concomitant procedures were performed in 43 (66.2%) patients. Mean bypass and cross-clamp times were 119.2 ± 30.3 and 87.1 ± 22.9 minutes, respectively. Postoperative transvalvular hemodynamics was excellent. There was one (1.5%) in-hospital death. Follow-up (mean 66.72 ± 12.77 months) was complete in 58 patients (89.2%). There were no detected valve-related or thromboembolic events. Transvalvular hemodynamic parameters were stable during the observation period: peak pressure gradient at discharge and follow-up was 15.3 ± 4.6 mmHg and 15.01 ± 6.3 mmHg, respectively (ρ = 0.346). CONCLUSIONS: AVNeo demonstrated the feasibility and favorable mid-term outcomes. Studies with longer-term observation are warranted to evaluate its durability.


Asunto(s)
Válvula Aórtica , Estudios de Factibilidad , Implantación de Prótesis de Válvulas Cardíacas , Pericardio , Trasplante Autólogo , Humanos , Persona de Mediana Edad , Masculino , Femenino , Pericardio/trasplante , Anciano , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Resultado del Tratamiento , Estudios Retrospectivos , Factores de Tiempo , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Adulto , Hemodinámica , Recuperación de la Función , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Procedimientos de Cirugía Plástica/efectos adversos , Procedimientos de Cirugía Plástica/métodos , Anciano de 80 o más Años
4.
Clin Breast Cancer ; 24(7): e613-e621, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39003171

RESUMEN

Breast reconstructive surgery has evolved significantly over the years. One of the recent advancements is the use of prepectoral implants in combination with synthetic and biological material as a natural and effective coverage. To date, there is little published data on breast reconstruction using acellular bovine pericardium matrix and most concern submuscular breast reconstruction. This study aimed to describe the multicentric-multisurgeon experience in performing direct to implant (DTI) prepectoral breast reconstructions using acellular bovine pericardium matrix (ABPM) pocket. A retrospective multicentric data collection of the all the immediate prepectoral breast reconstructions using acellular bovine pericardium was carried out by the authors. Surgical data including type of mastectomy, axillary surgery, type and size of implant, size of ABPM, duration of surgery were collected for each patient. Postoperative data including adjuvant treatments, complications, necessity to perform other interventions, patient's satisfaction were collected. Cosmetic results were also evaluated by 7 different observers at minimum 1 year follow-up. A total of 65 breast reconstruction were included in the study. Mean follow up was 21.3 months. Average surgical time was 1,42 hours. Minor complications occurred in 4 breasts; major complications occurred in 2 breasts. After 6 months follow-up, 7 patients underwent fat grafting to correct any rippling and /or wrinkling. Breast aesthetic and patients reported outcomes were satisfactory. Not significant capsular contracture was noted at the follow up control. To date, this is the largest study about prepectoral breast reconstruction with ABPM. On the basis of our results, prepectoral breast reconstruction ABPM assisted is a reliable, safe and suitable option providing good patient satisfaction outcomes.


Asunto(s)
Neoplasias de la Mama , Mastectomía , Pericardio , Humanos , Femenino , Pericardio/trasplante , Estudios Retrospectivos , Neoplasias de la Mama/cirugía , Neoplasias de la Mama/patología , Persona de Mediana Edad , Bovinos , Animales , Adulto , Mastectomía/métodos , Satisfacción del Paciente , Mamoplastia/métodos , Implantes de Mama , Implantación de Mama/métodos , Implantación de Mama/instrumentación , Implantación de Mama/efectos adversos , Estudios de Seguimiento , Anciano , Complicaciones Posoperatorias/etiología
5.
Ann Vasc Surg ; 108: 475-483, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39025221

RESUMEN

BACKGROUND: Biofilm formation is one of the greatest challenges encountered in vascular graft infections. Our aim is to compare the efficacy of 5 antibiotics against methicillin-susceptible Staphylococcus aureus (MSSA) biofilms on the surface of 4 vascular grafts. METHODS: In vitro study of 2 clinical MSSA strains (MSSA2 and MSSA6) and 4 vascular grafts (Dacron, Dacron-silver-triclosan (DST), Omniflow-II, and bovine pericardium). After a 24-hr incubation period, the graft samples were divided into 6 groups: growth control (no treatment), ciprofloxacin 4.5 mg/L, cloxacillin 100 mg/L, dalbavancin 300 mg/L, daptomycin 140 mg/L, and linezolid 20 mg/L. Quantitative cultures were obtained and results expressed as log10 colony-forming units per milliliter (CFU/mL). Analysis of variance was performed to compare biofilm formation between the different groups. RESULTS: The mean ± standard deviation MSSA2 count on the growth control Dacron graft was 10.05 ± 0.31 CFU/mL. Antibiotic treatment achieved a mean reduction of 45%; ciprofloxacin was the most effective antibiotic (64%). Baseline MSSA2 counts were very low on the DST (0.50 ± 1.03 CFU/mL) and Omniflow-II (0.33 ± 0.78 CFU/mL) grafts. On the bovine pericardium patch, the count was 9.87 ± 0.50 CFU/mL, but this was reduced by a mean of 45% after antibiotic treatment (61% for ciprofloxacin). The mean MSSA6 count on the growth control Dacron graft was 9.63 ± 0.53 CFU/mL. Antibiotics achieved a mean reduction of 48%, with ciprofloxacin performing best (67% reduction). The baseline MSSA6 count on the DST graft was 8.54 ± 0.73 CFU/mL. Antibiotics reduced biofilm formation by 72%; cloxacillin was the most effective treatment (86%). The MSSA6 count on the untreated Omniflow-II graft was 1.17 ± 1.52 CFU/mL. For the bovine pericardium patch, it was 8.98 ± 0.67 CFU/mL. The mean reduction after antibiotic treatment was 46%, with cloxacillin achieving the greatest reduction (68%). CONCLUSIONS: In this in vitro study, ciprofloxacin and cloxacillin performed best at reducing biofilms formed by clinical MSSA strains on the surface of biological and synthetic vascular grafts.


Asunto(s)
Antibacterianos , Biopelículas , Prótesis Vascular , Infecciones Relacionadas con Prótesis , Staphylococcus aureus , Biopelículas/efectos de los fármacos , Biopelículas/crecimiento & desarrollo , Prótesis Vascular/efectos adversos , Antibacterianos/farmacología , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Staphylococcus aureus/efectos de los fármacos , Staphylococcus aureus/crecimiento & desarrollo , Animales , Bovinos , Pericardio/trasplante , Diseño de Prótesis , Bioprótesis , Tereftalatos Polietilenos , Daptomicina/farmacología , Pruebas de Sensibilidad Microbiana , Infecciones Estafilocócicas/microbiología , Infecciones Estafilocócicas/tratamiento farmacológico , Ciprofloxacina/farmacología , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos
6.
J Med Case Rep ; 18(1): 314, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38978082

RESUMEN

BACKGROUND: The current study presents a novel and precise surgical technique for complete reconstruction of the aortic valve using glutaraldehyde-treated autologous pericardium in a patient with aortic valve disease and endocarditis. The technique aims to provide a more effective and reproducible method for aortic valve repair, with the goal of improving outcomes and quality of life for patients with aortic valve disease. CASE PRESENTATION: A 35-year-old Iranian male with aortic valve disease and endocarditis underwent aortic valve reconstruction surgery. Preoperative echocardiography showed a degenerative aortic valve with severe regurgitation, reduced left ventricular ejection fraction, and specific aortic root dimensions. The surgical technique involved precise measurements and calculations to design the size and shape of the new aortic valve cusps using autologous pericardium, with the goal of optimizing coaptation and function. The surgeon calculated the intercommissural distance based on the aortic annulus diameter to determine cusp size and shape. He tailored the pericardial cusps to have a height equal to 80% of the coaptation margin length. Detailed suturing techniques were used to ensure proper alignment and coaptation of the new cusps. Intraoperative evaluation of the valve function using suction and transesophageal echocardiography showed good coaptation and minimal residual regurgitation. At the 3-year follow-up, the patient had a well-functioning aortic valve with only trivial leak and was in satisfactory clinical condition. CONCLUSIONS: Glutaraldehyde-treated autologous pericardium is a validated leaflet alternative, and the causes of its failure are late annular dilatation and other technique breakdowns. Current evidence reveals that aortic valve reconstruction with glutaraldehyde-treated autologous pericardium is associated with many advantages with the potential to improve patient outcomes and quality of life. Further clinical studies are warranted to evaluate the long-term durability and efficacy of this approach.


Asunto(s)
Válvula Aórtica , Glutaral , Pericardio , Humanos , Masculino , Pericardio/trasplante , Adulto , Glutaral/uso terapéutico , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Trasplante Autólogo , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Procedimientos de Cirugía Plástica/métodos , Enfermedad de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Ecocardiografía Transesofágica , Ecocardiografía , Endocarditis/cirugía
7.
Gen Thorac Cardiovasc Surg ; 72(10): 690-692, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38907082

RESUMEN

We report on the "Triple-FP technique," a novel surgical approach for secondary spontaneous pneumothoraces, which combines a free pericardial fat pad, fibrin glue, and polyglycolic acid sheets. In our experience with 13 patients suffering from secondary spontaneous pneumothoraces, this method effectively prevented postoperative air leaks and re-operations. The technique includes the following steps: (1) harvesting free pericardial fat; (2) suturing around the lung parenchymal defect with the needles and thread left outside the thoracic cavity; (3) ensuring contact between the mediastinal pleural side of the fat and the lung; (4) applying fibrin glue to both the lung and fat before suturing; (5) securing the fat to the lung via the suture thread, reinforced with fibrin glue; and (6) stabilization with polyglycolic acid sheets and additional fibrin glue. This innovative technique is a reliable and effective treatment strategy for secondary spontaneous pneumothoraces, especially for patients with fragile lung tissue.


Asunto(s)
Tejido Adiposo , Adhesivo de Tejido de Fibrina , Pericardio , Neumotórax , Ácido Poliglicólico , Adhesivos Tisulares , Humanos , Adhesivo de Tejido de Fibrina/uso terapéutico , Neumotórax/cirugía , Pericardio/trasplante , Pericardio/cirugía , Ácido Poliglicólico/uso terapéutico , Femenino , Masculino , Adhesivos Tisulares/uso terapéutico , Tejido Adiposo/trasplante , Persona de Mediana Edad , Adulto , Resultado del Tratamiento , Técnicas de Sutura , Anciano
8.
J Cardiothorac Surg ; 19(1): 379, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38926836

RESUMEN

BACKGROUND: For acute type A aortic dissection involving the aortic root with root diameter no more than 45 mm, there are various aortic root repair techniques. In this study, a novel surgical technique using a pericardial autograft for aortic root repair was introduced. We described its surgical steps in detail and compare its clinical outcomes with direct suture technique. METHODS: Between July 2017 and August 2022, 95 patients with acute type A aortic dissection who underwent aortic root repair were enrolled, including aortic root repair using pericardial autograft (group A, n = 49) or direct suture (group B, n = 46). The patient's clinical data were retrospectively analyzed, and a 5-year follow-up was conducted. RESULTS: The 30-day mortality, re-exploration for bleeding, postoperative new-onset renal failure requiring continuous renal replacement therapy, stroke, and paraplegia occurred in 3%, 4%, 11%, 5%, and 2% of the overall patients, respectively. There was no significant difference in the 30-day mortality and complication rate between the two groups. The 30-day mortality and re-exploration for bleeding marked the primary endpoint events. Logistic regression analysis indicated that there was a significant correlation between the primary endpoint events and surgical technique (odds ratio, 0.002; 95% confidence interval, 0-0.159; P = 0.026). The aortic valve insufficiency of the two groups were significantly improved after operation (group A, P < 0.001; group B, P < 0.001). During follow-up, there was no significant difference in short-term survival between the two groups after surgery (log-rank P = 0.75), and all patients were free from reoperation for aortic disease. CONCLUSIONS: Patients who underwent aortic root repair using pericardial autograft tended to have reduced 30-day mortality and a lower risk of re-exploration for bleeding. Using pericardial autograft for aortic root repair is a safe and useful approach for patients with acute type A aortic dissection involving the aortic root.


Asunto(s)
Disección Aórtica , Pericardio , Humanos , Disección Aórtica/cirugía , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Pericardio/trasplante , Resultado del Tratamiento , Autoinjertos , Aneurisma de la Aorta Torácica/cirugía , Anciano , Enfermedad Aguda , Complicaciones Posoperatorias , Implantación de Prótesis Vascular/métodos , Trasplante Autólogo , Estudios de Seguimiento
10.
Asian Cardiovasc Thorac Ann ; 32(4): 194-199, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38767039

RESUMEN

BACKGROUND: Valvular heart diseases (VHDs) have become prevalent in populations due to aging. Application of different biomaterials for cardiac valve regeneration and repair holds a great promise for treatment of VHD. Aortic valve replacement using tissue-engineered xenografts is a considered approach, and the pericardium of different species such as porcine and bovine has been studied over the last few years. It has been suggested that the animal origin can affect the outcomes of replacement. METHODS: So, herein, we at first decellularized and characterized the camel pericardium (dCP), then characterized dCP with H&E staining, in vitro and in vivo biocompatibility and mechanical tests and compared it with decellularized bovine pericardium (dBP), to describe the potency of dCP as a new xenograft and bio scaffold. RESULTS: The histological assays indicated less decluttering and extracellular matrix damage in dCP after decellularization compared to the dBP also dCP had higher Young Modulus (105.11), and yield stress (1.57 ± 0.45). We observed more blood vessels and also less inflammatory cells in the dCP sections after implantation. CONCLUSIONS: In conclusion, the results of this study showed that the dCP has good capabilities not only for use in VHD treatment but also for other applications in tissue engineering and regenerative medicine.


Asunto(s)
Bioprótesis , Camelus , Prótesis Valvulares Cardíacas , Pericardio , Medicina Regenerativa , Ingeniería de Tejidos , Andamios del Tejido , Animales , Pericardio/trasplante , Medicina Regenerativa/métodos , Bovinos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Ensayo de Materiales , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/patología , Diseño de Prótesis , Matriz Extracelular Descelularizada/química , Xenoinjertos , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/fisiopatología , Enfermedades de las Válvulas Cardíacas/patología , Regeneración
11.
Tex Heart Inst J ; 51(1)2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38711341

RESUMEN

A 62-year-old woman who had undergone mitral valve replacement 24 years ago was admitted to the hospital with congestive heart failure. She needed heart transplantation for stage D heart failure. Preoperative cardiac computed tomographic scans showed a severely calcified left atrium and a large right atrium. Given that the left atrium's calcification was too severe to suture, the calcified left atrial wall was broadly resected, and the resected left atrial wall was reconstructed with a bovine pericardial patch for anastomosis with the donor's left atrial wall. The operation was completed without heavy bleeding, and the patient was discharged from the hospital with no complications.


Asunto(s)
Calcinosis , Atrios Cardíacos , Insuficiencia Cardíaca , Trasplante de Corazón , Cardiopatía Reumática , Tomografía Computarizada por Rayos X , Humanos , Femenino , Cardiopatía Reumática/cirugía , Cardiopatía Reumática/complicaciones , Cardiopatía Reumática/diagnóstico , Trasplante de Corazón/métodos , Persona de Mediana Edad , Calcinosis/cirugía , Calcinosis/diagnóstico , Calcinosis/complicaciones , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/diagnóstico , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Pericardio/trasplante , Pericardio/cirugía
12.
Artículo en Inglés | MEDLINE | ID: mdl-38712707

RESUMEN

In a 39-year-old male with mitral valve endocarditis, after 6 weeks of intravenous antibiotics, echocardiography confirmed multiple vegetations on both leaflets, a flail posterior leaflet flail and contained perforation of the anterior leaflet in a windsock-like morphology. All vegetations, diseased and ruptured chords and the windsock-like contained rupture of the anterior leaflet were carefully resected via a right minithoracotomy and with femoral cannulation. Three repair techniques were blended to reconstruct the valve: (1) A large, infected portion of the prolapsing posterior leaflet was resected in a triangular fashion, and the edges were re-approximated using continuous 5-0 polypropylene sutures. (2) The anterior leaflet defect was repaired with a circular autologous pericardial patch that had been soaked in glutaraldehyde. (3) A set of artificial chords for P2 was created using CV-4 polytetrafluoroethylene sutures and adjusted under repeated saline inflation. A 38-mm Edwards Physio-I annuloplasty ring was implanted. The artificial chords were adjusted again after annuloplasty and then tied. Transoesophageal echocardiography (TEE) confirmed the absence of residual mitral regurgitation and systolic anterior motion and a mean pressure gradient of 3 mmHg. The patient was discharged after 5 days with a peripherally inserted central catheter to complete an additional 4 weeks of intravenous antibiotics and had an uneventful recovery.


Asunto(s)
Ecocardiografía Transesofágica , Válvula Mitral , Humanos , Masculino , Adulto , Válvula Mitral/cirugía , Anuloplastia de la Válvula Mitral/métodos , Endocarditis Bacteriana/cirugía , Endocarditis Bacteriana/diagnóstico , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico , Técnicas de Sutura , Implantación de Prótesis de Válvulas Cardíacas/métodos , Endocarditis/cirugía , Endocarditis/diagnóstico , Pericardio/trasplante
13.
Artículo en Inglés | MEDLINE | ID: mdl-38749719

RESUMEN

An 82-year-old male patient underwent a left upper lobectomy with anterolateral thoracotomy for lung cancer. Although a complete left-pericardial defect was observed during surgery, the pericardial repair was not performed because the left lower lobe remained and the heart was considered stable. Postoperative pathological examination revealed primary synchronous double-lung squamous-cell carcinoma (pathological stage pT2a(2)N0M0 stage IB). He was discharged without complications on postoperative day 8. Leftward displacement of the heart and left diaphragmatic elevation, suspected of phrenic-nerve paralysis, were found in the chest X-ray after discharge. However, the patient's overall condition remained unaffected at the 5-month postoperative follow-up. To assess the need for pericardial repair, we compared cases of complete pericardial defects observed during lobectomy or pneumonectomy reported in the literature. Only one of 12 cases occurred postoperative death despite pericardial repair, and that case combined pectus excavatum and pericardial defects. Our assessment indicated that pericardial repair might not be necessary, excluding complex cases.


Asunto(s)
Carcinoma de Células Escamosas , Hallazgos Incidentales , Neoplasias Pulmonares , Pericardio , Neumonectomía , Humanos , Masculino , Neoplasias Pulmonares/cirugía , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Neumonectomía/efectos adversos , Pericardio/trasplante , Anciano de 80 o más Años , Resultado del Tratamiento , Carcinoma de Células Escamosas/cirugía , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/patología , Toracotomía , Tomografía Computarizada por Rayos X , Cardiopatías Congénitas/cirugía , Cardiopatías Congénitas/diagnóstico por imagen , Estadificación de Neoplasias
14.
Artículo en Inglés | MEDLINE | ID: mdl-38787287

RESUMEN

Aortic root reconstruction during aortic root replacement for a patient with prosthetic valve endocarditis and aortic root abscess can be a difficult procedure with many possible complications. In this video case report, we describe our novel technique using a single bovine pericardial patch that avoids deep stitches or external sutures to support the friable annulus. Compared with more standard methods, this approach has shorter cross-clamp and cardiopulmonary bypass times and is less demanding technically.


Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Animales , Bovinos , Humanos , Masculino , Válvula Aórtica/cirugía , Endocarditis/cirugía , Endocarditis Bacteriana/cirugía , Endocarditis Bacteriana/diagnóstico , Implantación de Prótesis de Válvulas Cardíacas/métodos , Pericardio/trasplante , Procedimientos de Cirugía Plástica/métodos , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/etiología , Anciano
15.
Ann Vasc Surg ; 105: 177-188, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38599483

RESUMEN

BACKGROUND: The use of biological grafts provides acceptable mid- and long-term results in native or prosthetic vascular infections. Several reports describe the successful use of bovine pericardium in case of vascular infections, mainly as a large patch to be sutured as a tubular graft. Recently, a novel prefabricated bovine pericardium graft (Biointegral Surgical No-React® Inc, Mississauga, ON, Canada) has been introduced in clinical practice with promising results. In this study, we report our preliminary experience utilizing Biointegral Surgical graft in case of native and or prosthetic aorto-iliac and infrainguinal infection. METHODS: We retrospectively analyzed data from 20 patients with native or prosthetic aorto-iliac and infrainguinal infection who underwent in situ reconstruction (ISR) with a Biointegral Surgical No-React bovine pericardium prosthesis between October 2020 and February 2023 at the Vascular Surgery Unit of the Fondazione Policlinico Universitario Gemelli - IRCCS in Rome, Italy. All patients followed a standardized protocol including postoperative anticoagulation and long-term intravenous antibiotics. RESULTS: The indication for surgery was: mycotic aortic aneurysm in 4 patients (20%), graft infection after abdominal aortic repair in 11 patients (55%), peripheral graft infection in 5 patients (25%). Complete excision of the infected aorta or prosthetic graft, surgical debridement and ISR were performed in all patients. Hospital mortality rate was 5% (n = 1) and graft-related mortality of 0%. During follow-up (median 13 months, range 6-34 months), reinfection was 5.2% and primary graft patency 94.7%. CONCLUSIONS: The use of prefabricated bovine pericardial grafts represents a promising option for the treatment of native and prosthetic aorto-iliac and infrainguinal infections. The application of this biological graft with a standardized postoperative protocol has been associated with a satisfactory patency and reinfection rate without increased bleeding complications.


Asunto(s)
Bioprótesis , Implantación de Prótesis Vascular , Prótesis Vascular , Pericardio , Diseño de Prótesis , Infecciones Relacionadas con Prótesis , Humanos , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/mortalidad , Prótesis Vascular/efectos adversos , Estudios Retrospectivos , Pericardio/trasplante , Masculino , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Anciano , Resultado del Tratamiento , Femenino , Persona de Mediana Edad , Animales , Bovinos , Factores de Tiempo , Xenoinjertos , Anciano de 80 o más Años , Arteria Ilíaca/cirugía , Antibacterianos/administración & dosificación , Factores de Riesgo , Grado de Desobstrucción Vascular , Aneurisma Infectado/cirugía , Aneurisma Infectado/microbiología , Aneurisma Infectado/mortalidad , Aneurisma Infectado/diagnóstico por imagen , Reoperación
16.
Jpn J Ophthalmol ; 68(3): 192-199, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38553632

RESUMEN

PURPOSE: To evaluate the changes in thickness of tissues, specifically the pericardium patch graft (PPG) covering the silicone tube in Ahmed Glaucoma Valve (AGV) surgery. STUDY DESIGN: Prospective observational study. METHODS: This study included cases with refractory glaucoma that underwent AGV implantation with PPG coverage. Conjunctival epithelium, stroma and PPG thickness covering the tube were measured using anterior segment optical coherence tomography (AS-OCT) at 1, 6 and 12 months. Additionally, the same measurements were taken 1500 µm away from the tube as a control for the central measurements. RESULTS: Twenty-seven eyes of 27 patients were evaluated in the study. Although PPG thickness decreased significantly in both regions, the amount of reduction was more pronounced centrally. Centrally, the reduction rate was 21.2% and 34.8% during the 1-6 months period and 6-12 months period, while peripherally it was 3.5% and 5.1%, respectively. No change was observed in the thickness of the epithelium during the follow-up period. There was a significant thinning of the stroma in the central and peripheral regions during the 1-6 months period (30.5% and 17%, respectively). No cases of exposure were observed during the follow-up period. CONCLUSION: Although the most evident thinning of the layers covering the tube was observed in the early postoperative period, PPG showed a stable decrease even in the late period. The progressive reduction in the PPG thickness observed also in the peripheral region indicates that factors beyond mechanical forces contribute to this degenerative process. AS-OCT could be a valuable non-invasive tool in clarifying this process.


Asunto(s)
Segmento Anterior del Ojo , Implantes de Drenaje de Glaucoma , Glaucoma , Presión Intraocular , Pericardio , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Masculino , Femenino , Estudios Prospectivos , Pericardio/trasplante , Presión Intraocular/fisiología , Glaucoma/cirugía , Glaucoma/fisiopatología , Glaucoma/diagnóstico , Persona de Mediana Edad , Segmento Anterior del Ojo/diagnóstico por imagen , Anciano , Estudios de Seguimiento , Adulto , Anciano de 80 o más Años
17.
BMC Cardiovasc Disord ; 24(1): 163, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38504187

RESUMEN

BACKGROUND: Aortic valve reconstruction using glutaraldehyde-treated autologous pericardium, also called Ozaki procedure, is a surgical procedure for patients with aortic valve disease. Gratifying results have been reported in adult patients, however, limited published data is available in paediatric population. This study looked at clinical characteristics and early outcomes of children who underwent Ozaki procedure at our Institute. METHODS: This was a retrospective descriptive study conducted on children who underwent aortic valve reconstruction at Jakaya Kikwete Cardiac Institute (JKCI) from January 2019 through December 2022. Medical records of these children were reviewed to extract data on demographics, clinical characteristics, redo surgical interventions and survival. RESULTS: A total of 10 children underwent Ozaki procedure during the study period. Eight children had severe aortic regurgitation while 2 had severe aortic stenosis preoperatively. All children had either none or trivial aortic regurgitation immediately after surgery. None of them had redone operations throughout the follow-up period. There was no in-hospital mortality, however, one child died one-year after surgery. The mean follow-up period was 1.6 years with the longest follow-up time of 4 years. CONCLUSION: Ozaki procedure showed encouraging early results among children with aortic valve disease who underwent surgical repair by this technique. Future studies with larger sample sizes and longer follow up periods to evaluate long-term results in this population are recommended.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Adulto , Niño , Humanos , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Tanzanía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Pericardio/trasplante , Resultado del Tratamiento
18.
Ann Vasc Surg ; 102: 181-191, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38307226

RESUMEN

BACKGROUND: Infected aortic grafts and mycotic aneurysms represent one of the most complex challenges faced by vascular surgeons. Treatment has progressed from extra-anatomical bypass to in situ reconstruction. Additionally, bovine pericardium reconstruction (BPR) has increased, due to accessibility and reduced lower limb morbidity. There remains, however, limited evidence for its use. The aim is to pool all known data to understand outcomes following BPR of mycotic aneurysms or infected vascular grafts. METHODS: A systematic review was conducted in November 2021 with subsequent computerized meta-analysis of the pooled results and a final search in March 2022. Three databases, Excerpta Medica dataBASE (EMBASE), Cumulative Index of Nursing and Allied Health Literature (CINAHL), and National Institutes of Health PubMed (PubMed), were searched for the search term "(bovine OR xenoprosthetic) AND (aneurysm)", according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. RESULTS: From 9 studies, there were 133 patients: 67% graft infections and 33% mycotic aneurysms. Fifty-seven percent of reconstructions were in the abdominal aorta and 33% were in the thoracic aorta. One hundred fifty-eight pathogens were identified, including Staphylococcus aureus (23%), Candida albicans (13%), and Escherichia coli (13%). In 12%, no microorganisms were identified. Thirty-day mortality was 19.14% (CI 10.83-28.71), late mortality was 19.08% (confidence interval [CI] 7.76-32.83), and overall mortality was 40.20% (CI 29.82-50.97). One patient died intraoperatively. There were a total of 151 in-hospital complications after 30 days postoperation. Common complications were acute renal failure (17%), pneumonia (14%), delirium (12%), respiratory insufficiency (11%) and renal insufficiency (7%). Lower limb ischemia was low, occurring in 5.66% (CI 0.54-13.82) of patients. Loss of graft patency leading to reintervention occurred in 1.20% (CI 0.00-7.71) of the grafts. Reinfection rate was 0.00% (CI 0.00-1.21). CONCLUSIONS: This meta-analysis highlights low reinfection and high graft patency using BPR with medium-length follow-up; however, there remain limited long-term and comparative data regarding options for aortic reconstruction. As expected in this complex cohort, the complication rate and 30-day mortality remain high.


Asunto(s)
Aneurisma Infectado , Bioprótesis , Implantación de Prótesis Vascular , Prótesis Vascular , Xenoinjertos , Pericardio , Infecciones Relacionadas con Prótesis , Aneurisma Infectado/cirugía , Aneurisma Infectado/microbiología , Aneurisma Infectado/mortalidad , Aneurisma Infectado/diagnóstico por imagen , Humanos , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Animales , Pericardio/trasplante , Resultado del Tratamiento , Bovinos , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/mortalidad , Factores de Riesgo , Masculino , Femenino , Factores de Tiempo , Anciano , Persona de Mediana Edad , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta/microbiología , Aneurisma de la Aorta/mortalidad , Aneurisma de la Aorta/diagnóstico por imagen , Medición de Riesgo , Anciano de 80 o más Años
19.
Eur J Vasc Endovasc Surg ; 67(6): 997-1005, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38341175

RESUMEN

OBJECTIVE: This study examines outcome and durability of physician made bovine pericardial tube grafts in aortic infections in all anatomical locations. METHODS: This was a retrospective and prospective international multicentre study. Peri-operative and long term outcomes of patients undergoing in situ aortic reconstruction for native or graft infections with physician made bovine pericardial tube grafts between January 2008 and December 2020 in four European tertiary referral centres were analysed. The primary endpoint was recurrent aortic infection. Secondary endpoints were persistent infection, aortic re-operation for infection, graft related complications, and death. RESULTS: One hundred and sixty eight patients (77% male, mean age 67 ± 11 years) were identified: 38 (23%) with native and 130 (77%) with aortic graft infection. The thirty day mortality rate was 15% (n = 26) overall, 11% (n = 4), and 17% (n = 22) for native and aortic graft infections, respectively (p = .45). Median follow up was 26 months (interquartile range [IQR] 10, 51). Estimated survival at one, two, three, and five years was 64%, 60%, 57%, and 50%, and significantly better for native (81%, 77%, 77%, and 69%) than for graft infections (58%, 55%, 51%, and 44%; p = .011). Nine patients (5.3%) had persistent infection and 10 patients (6%) had aortic re-infection after a median of 10 months (IQR 5, 22), resulting in an estimated freedom from re-infection at one, two, three, and five years of 94%, 92%, 90%, and 86%. Estimated freedom from graft complications at one, two, three, and five years was 91%, 89%, 87%, and 87%. CONCLUSION: This multicentre study demonstrates low re-infection rates when using physician made bovine pericardial tube grafts, comparable to those of other biological grafts. The rate of graft complications, mainly anastomotic aneurysms and stenoses, was low, while graft degeneration was absent. Physician made bovine pericardial tube grafts are an excellent tool for in situ reconstruction in the setting of native aortic infection or aortic graft infection.


Asunto(s)
Bioprótesis , Implantación de Prótesis Vascular , Prótesis Vascular , Pericardio , Infecciones Relacionadas con Prótesis , Reoperación , Humanos , Masculino , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Relacionadas con Prótesis/mortalidad , Infecciones Relacionadas con Prótesis/microbiología , Anciano , Femenino , Prótesis Vascular/efectos adversos , Bovinos , Pericardio/trasplante , Estudios Retrospectivos , Persona de Mediana Edad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Europa (Continente) , Bioprótesis/efectos adversos , Reoperación/estadística & datos numéricos , Estudios Prospectivos , Animales , Resultado del Tratamiento , Recurrencia , Diseño de Prótesis , Aorta/cirugía , Factores de Tiempo
20.
Braz J Cardiovasc Surg ; 38(6): e20220370, 2023 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-37797236

RESUMEN

INTRODUCTION: Aortic stenosis (AS) is the most common valvular heart disease and the most common indication for aortic valve replacement in adults. Aortic valve neocuspidization (AVNeo) with fixed autologous pericardium, also known as the Ozaki procedure, is a possible alternative treatment of AS. Autopericardial valves save the dynamics and physiological anatomy of the aortic root, however, the service life of autopericardial leaflets is limited. There is no data about factors that may influence the development of AVNeo insufficiency. Here, we assessed the effect of autopericardial leaflet symmetry on the development of aortic insufficiency after Ozaki procedure. METHODS: This study included 381 patients with AS who underwent Ozaki procedure. Patients were divided into group 1 (171 patients with symmetric aortic root) and group 2 (210 patients with asymmetric aortic root). RESULTS: The maximum observation period was up to 65 months. Sixteen cases of aortic insufficiency were detected in group 1, and 33 cases were detected in group 2. Based on the results of Cox regression, the predictors of aortic insufficiency in the late postoperative period are age and asymmetry of neocusps. According to results of Kaplan-Meier analysis, insufficiency of AVNeo in the maximum follow-up period after surgical correction of AS for group 1 patients was significantly lower than for group 2 patients (P=0.006). CONCLUSION: Asymmetric neocusps increase the risk of aortic insufficiency in the mid-term period after Ozaki procedure. And the older the patients at the time of surgery, the less likely they develop AVNeo insufficiency.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Adulto , Humanos , Válvula Aórtica/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Estenosis de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Pericardio/trasplante , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA