1.
PLoS One ; 19(9): e0309981, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39240983

RESUMEN

BACKGROUND: Oscillometry devices (also termed forced oscillation technique) devices such as MasterScreen-IOS® (Jaeger, Hochberg, Germany) and MostGraph-01® (Chest, Tokyo, Japan) are useful for obtaining physiological assessments in patients with obstructive lung diseases, including asthma. However, as oscillometry measurements have not been fully compared between MasterScreen-IOS® and MostGraph-01® in patients with asthma, it is unknown whether there are differences in the measurements between the devices. This study aimed to determine whether there is any difference in oscillometry measurements obtained using the two devices in patients with asthma. METHODS: Oscillometry measurements obtained using MasterScreen-IOS® and MostGraph-01® were retrospectively evaluated in 95 patients with asthma at Juntendo University Hospital between October 2009 and November 2009. RESULTS: There was a strong positive correlation in the measurements between the two devices. However, the values of R5, R20, ALX and Fres were lower when measured with MostGraph-01® than with MasterScreen-IOS®, and vice versa for the values of X5. The results were used in correction equations to convert oscillometry parameters measured using MasterScreen-IOS® to those measured using MostGraph-01®. CONCLUSIONS: To our knowledge, this is the first report to compare MostGraph-01® and MasterScreen-IOS® devices using practical clinical data obtained in patients with asthma. The values obtained by both devices can be interpreted in a similar way, although there is slight variation. The conversion equations produced in this study may assist to compare the oscillometry measurements obtained by each of the two devices.


Asunto(s)
Asma , Oscilometría , Humanos , Asma/fisiopatología , Asma/diagnóstico , Oscilometría/métodos , Oscilometría/instrumentación , Masculino , Femenino , Persona de Mediana Edad , Anciano , Adulto , Estudios Retrospectivos , Pruebas de Función Respiratoria/métodos , Pruebas de Función Respiratoria/instrumentación
2.
Folia Med (Plovdiv) ; 66(4): 453-460, 2024 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-39257264

RESUMEN

Obstructive lung diseases such as bronchial asthma, COPD, and cystic fibrosis are a burden on many patients across the globe. Spirometry is considered the gold standard for diagnosing airflow obstruction, but it can be difficult for pediatric patients to do and requires a lot of effort. As a result, healthcare providers need new, effortless methods to diagnose airway obstructions, particularly in young children and individuals unable to perform the spirometry maneuver. The forced oscillation technique is a modern method requiring only tidal breathing combined with the application of external, source of low-amplitude oscillations to evaluate the respiratory system's response. It might be essential for identifying early respiratory changes caused by smoking, childhood asthma, and may prove more sensitive than spirometry in identifying peripheral airway disturbances or evaluating the long-term success of therapy. This review describes the methodology and the indications for the forced oscillation technique and outlines its relevance in clinical practice.


Asunto(s)
Enfermedades Pulmonares Obstructivas , Humanos , Niño , Enfermedades Pulmonares Obstructivas/diagnóstico , Enfermedades Pulmonares Obstructivas/terapia , Enfermedades Pulmonares Obstructivas/fisiopatología , Espirometría/métodos , Asma/diagnóstico , Asma/terapia , Asma/fisiopatología , Fibrosis Quística/diagnóstico , Fibrosis Quística/terapia , Fibrosis Quística/fisiopatología , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Enfermedad Pulmonar Obstructiva Crónica/terapia , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Pruebas de Función Respiratoria , Oscilometría/métodos
3.
Respir Res ; 25(1): 300, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39113044

RESUMEN

BACKGROUND: In recent years, the incorporation of LAMAs into asthma therapy has been expected to enhance symptom control. However, a significant number of patients with asthma continue to experience poorly managed symptoms. There have been limited investigations on LAMA-induced airway alterations in asthma treatment employing IOS. In this study, we administered a LAMA to patients with poorly controlled asthma, evaluated clinical responses and respiratory function, and investigated airway changes facilitated by LAMA treatments using the IOS. METHODS: Of a total of 1282 consecutive patients with asthma, 118 exhibited uncontrolled symptoms. Among them, 42 switched their treatment to high-dose fluticasone furoate/umeclidinium/vilanterol (FF/UMEC/VI) (ICS/LABA/LAMA). The patients were then assessed using AHQ-33 or LCQ and ACT. Spirometry parameters (such as FEV1 or MMEF) and IOS parameters (such as R20 or AX) were measured and compared before and after exacerbations and the addition of LAMA. RESULTS: Of the 42 patients, 17 who switched to FF/UMEC/VI caused by dyspnea exhibited decreased pulmonary function between period 1 and baseline, followed by an increase in pulmonary function between baseline and period 2. Significant differences were observed in IOS parameters such as R20, R5-R20, Fres, or AX between period 1 and baseline as well as between baseline and period 2. Among the patients who switched to inhaler due to cough, 25 were classified as responders (n = 17) and nonresponders (n = 8) based on treatment outcomes. Among nonresponders, there were no significant differences in spirometry parameters such as FEV1 or PEF and IOS parameters such as R20 or AX between period 1 and baseline. However, among responders, significant differences were observed in all IOS parameters, though not in most spirometry parameters, between period 1 and baseline. Furthermore, significant differences were noted between baseline and period 2 in terms of FEV1, %MMEF, %PEF, and all IOS parameters. CONCLUSION: ICS/LABA/LAMA demonstrates superiority over ICS/LABA in improving symptoms and lung function, which is primarily attributed to the addition of LAMA. Additionally, IOS revealed the effectiveness of LAMA across all airway segments, particularly in the periphery. Hence, LAMA can be effective against various asthma phenotypes characterized by airway inflammation, even in real-world cases.


Asunto(s)
Asma , Antagonistas Muscarínicos , Oscilometría , Humanos , Femenino , Masculino , Persona de Mediana Edad , Antagonistas Muscarínicos/administración & dosificación , Asma/tratamiento farmacológico , Asma/fisiopatología , Asma/diagnóstico , Resultado del Tratamiento , Oscilometría/métodos , Adulto , Anciano , Combinación de Medicamentos , Quinuclidinas/administración & dosificación , Clorobencenos/administración & dosificación , Broncodilatadores/administración & dosificación , Antiasmáticos/administración & dosificación , Antiasmáticos/uso terapéutico
4.
Vet Anaesth Analg ; 51(5): 482-490, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39138049

RESUMEN

OBJECTIVE: To evaluate the agreement between measurements of invasive blood pressure (IBP) and oscillometric blood pressure from the tongue (OBPton) using a multiparameter monitor. STUDY DESIGN: Unblinded, prospective, experimental study. ANIMALS: A total of 12 female Large White crossbreed pigs. METHODS: Pigs undergoing experimental procedures that required arterial cannula placement were recruited. A blood pressure cuff with the closest width to 40% of the circumference of the tongue was placed rostral to the lingual frenulum. Systolic, mean and diastolic IBP and OBPton were measured simultaneously at 5 minute intervals. Agreement between paired measurements was examined using Bland-Altman analysis. Mean bias, precision (standard deviation of mean bias), 95% limits of agreement, correlation coefficients and percentage of measurements within 10 and 20 mmHg of IBP were calculated. RESULTS: The total numbers of paired measurements recorded were 124, 126 and 124 for systolic, mean and diastolic blood pressures, respectively. The mean bias, precision and 95% limits of agreement for systolic OBPton were 11.5, 11.5 (-11.1 to 34.2), for mean OBPton 5.6, 5.7 (-5.7 to 16.8) and for diastolic OBPton 7.6, 10.1 (-12.1 to 27.4) mmHg. Correlation coefficients were greater than 0.9 for mean OBPton only. More than 50% of measurements were within 10 mmHg of IBP and 80% of measurements were within 20 mmHg of IBP for mean and diastolic OBPton only. CONCLUSIONS AND CLINICAL RELEVANCE: The tongue as a cuff site for oscillometric blood pressure measurement is a useful site for measuring mean arterial, but not systolic or diastolic blood pressure in anaesthetized Large White crossbreed pigs. This technique fulfils the American College of Veterinary Internal Medicine criteria for measuring mean arterial pressure but not systolic or diastolic arterial pressure.


Asunto(s)
Determinación de la Presión Sanguínea , Presión Sanguínea , Oscilometría , Lengua , Animales , Femenino , Determinación de la Presión Sanguínea/veterinaria , Determinación de la Presión Sanguínea/métodos , Porcinos/fisiología , Oscilometría/veterinaria , Oscilometría/métodos , Lengua/fisiología , Presión Sanguínea/fisiología , Estudios Prospectivos
5.
BMC Anesthesiol ; 24(1): 221, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38961365

RESUMEN

BACKGROUND: This study aimed to evaluate the accuracy of ankle blood pressure measurements in relation to invasive blood pressure in the lateral position. METHODS: This prospective observational study included adult patients scheduled for elective non-cardiac surgery under general anesthesia in the lateral position. Paired radial artery invasive and ankle noninvasive blood pressure readings were recorded in the lateral position using GE Carescape B650 monitor. The primary outcome was the ability of ankle mean arterial pressure (MAP) to detect hypotension (MAP < 70 mmHg) using area under the receiver operating characteristic curve (AUC) analysis. The secondary outcomes were the ability of ankle systolic blood pressure (SBP) to detect hypertension (SBP > 140 mmHg) as well as bias (invasive measurement - noninvasive measurement), and agreement between the two methods using the Bland-Altman analysis. RESULTS: We analyzed 415 paired readings from 30 patients. The AUC (95% confidence interval [CI]) of ankle MAP for detecting hypotension was 0.88 (0.83-0.93). An ankle MAP of ≤ 86 mmHg had negative and positive predictive values (95% CI) of 99 (97-100)% and 21 (15-29)%, respectively, for detecting hypotension. The AUC (95% CI) of ankle SBP to detect hypertension was 0.83 (0.79-0.86) with negative and positive predictive values (95% CI) of 95 (92-97)% and 36 (26-46)%, respectively, at a cutoff value of > 144 mmHg. The mean bias between the two methods was - 12 ± 17, 3 ± 12, and - 1 ± 11 mmHg for the SBP, diastolic blood pressure, and MAP, respectively. CONCLUSION: In patients under general anesthesia in the lateral position, ankle blood pressure measurements are not interchangeable with the corresponding invasive measurements. However, an ankle MAP > 86 mmHg can exclude hypotension with 99% accuracy, and an ankle SBP < 144 mmHg can exclude hypertension with 95% accuracy.


Asunto(s)
Anestesia General , Tobillo , Determinación de la Presión Sanguínea , Humanos , Femenino , Anestesia General/métodos , Masculino , Estudios Prospectivos , Persona de Mediana Edad , Determinación de la Presión Sanguínea/métodos , Tobillo/irrigación sanguínea , Anciano , Oscilometría/métodos , Presión Sanguínea/fisiología , Hipertensión/fisiopatología , Hipertensión/diagnóstico , Hipotensión/diagnóstico , Hipotensión/fisiopatología , Adulto , Posicionamiento del Paciente/métodos
6.
Turk J Med Sci ; 54(2): 441-448, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39050388

RESUMEN

Background/aim: There is limited information on the pathologic changes in the small airways among obese and nonobese patients with obstructive sleep apnea syndrome (OSAS). Impulse oscillometry (IOS) measures airway resistance and reactance independently of patient effort. This study aimed to compare airway resistance in small airways using IOS between obese and nonobese patients with OSAS. Materials and methods: In this real-life cross-sectional study, demographic information was collected from obese and nonobese subjects diagnosed with moderate and severe OSAS without any other underlying diseases. Spirometry and IOS measurements were conducted, and the values of both groups were statistically analyzed. Results: The nonobese group had a mean age of 45.6 ± 11.7 years (median 45), while the obese group had a mean age of 48.4 ± 9.5 years (median 47.5). The mean body mass index (BMI) for the nonobese group was 26.2 ± 2.1 kg/m2 (median 27 kg/m2), and for the obese group, it was 35.6 ± 6.4 kg/m2 (median 33 kg/m2). Statistically significant differences were observed between the two groups in R5 - R20 percentage, reactance area (AX), and resonant frequency (Fres) values (p < 0.05). Conclusion: Among obese OSAS patients, there is an increase in resistance in small airways as indicated by IOS values. IOS shows promise as a potential screening tool for diagnosing OSAS.


Asunto(s)
Resistencia de las Vías Respiratorias , Obesidad , Oscilometría , Apnea Obstructiva del Sueño , Humanos , Apnea Obstructiva del Sueño/fisiopatología , Apnea Obstructiva del Sueño/diagnóstico , Persona de Mediana Edad , Masculino , Estudios Transversales , Obesidad/fisiopatología , Obesidad/complicaciones , Resistencia de las Vías Respiratorias/fisiología , Oscilometría/métodos , Femenino , Adulto , Espirometría/métodos , Índice de Masa Corporal
7.
Respir Res ; 25(1): 286, 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39048993

RESUMEN

BACKGROUND: The use of machine learning(ML) methods would improve the diagnosis of small airway dysfunction(SAD) in subjects with chronic respiratory symptoms and preserved pulmonary function(PPF). This paper evaluated the performance of several ML algorithms associated with the impulse oscillometry(IOS) analysis to aid in the diagnostic of respiratory changes in SAD. We also find out the best configuration for this task. METHODS: IOS and spirometry were measured in 280 subjects, including a healthy control group (n = 78), a group with normal spirometry (n = 158) and a group with abnormal spirometry (n = 44). Various supervised machine learning (ML) algorithms and feature selection strategies were examined, such as Support Vector Machines (SVM), Random Forests (RF), Adaptive Boosting (ADABOOST), Navie Bayesian (BAYES), and K-Nearest Neighbors (KNN). RESULTS: The first experiment of this study demonstrated that the best oscillometric parameter (BOP) was R5, with an AUC value of 0.642, when comparing a healthy control group(CG) with patients in the group without lung volume-defined SAD(PPFN). The AUC value of BOP in the control group was 0.769 compared with patients with spirometry defined SAD(PPFA) in the PPF population. In the second experiment, the ML technique was used. In CGvsPPFN, RF and ADABOOST had the best diagnostic results (AUC = 0.914, 0.915), with significantly higher accuracy compared to BOP (p < 0.01). In CGvsPPFA, RF and ADABOOST had the best diagnostic results (AUC = 0.951, 0.971) and significantly higher diagnostic accuracy (p < 0.01). In the third, fourth and fifth experiments, different feature selection techniques allowed us to find the best IOS parameters (R5, (R5-R20)/R5 and Fres). The results demonstrate that the performance of ADABOOST remained essentially unaltered following the application of the feature selector, whereas the diagnostic accuracy of the remaining four classifiers (RF, SVM, BAYES, and KNN) is marginally enhanced. CONCLUSIONS: IOS combined with ML algorithms provide a new method for diagnosing SAD in subjects with chronic respiratory symptoms and PPF. The present study's findings provide evidence that this combination may help in the early diagnosis of respiratory changes in these patients.


Asunto(s)
Aprendizaje Automático , Espirometría , Humanos , Masculino , Femenino , Persona de Mediana Edad , Adulto , Espirometría/métodos , Anciano , Oscilometría/métodos , Máquina de Vectores de Soporte , Pulmón/fisiopatología
8.
Kidney Blood Press Res ; 49(1): 667-675, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38934146

RESUMEN

INTRODUCTION: The aim of the presented prospective observational study was to evaluate the effect of fistula flow on peripheral wave morphology and pulse wave velocity by means of the oscillometric Vicorder®-device with the purpose of fistula surveillance. METHODS: Digitized and normalized curves of 53 haemodialysis patients at the fistula and non-fistula arm were analysed. Slope parameters and the areas under the curve of characteristic sections of pulse waves as well as the power spectrum of the pulse waves and their first and second derivatives were computed. Furthermore, the amplitude of volumetric change (AMP) was assessed. Duplex sonography served as a reference method. RESULTS: In the comprehensive set of novel pulse wave parameters significant inter-arm differences were demonstrated and a significant delay of the systolic maximum at the fistula arm in comparison to the non-fistula arm (204 ± 3.4 vs. 162 ± 5.3 ms, p < 0.001) was proven. Unexpectedly, pulse wave velocity apparently did not differ between both arms (7.85 vs. 8.05 m/s at the fistula/non-fistula side, p = 0.942). The inter-arm differences of the slope parameters were more pronounced in forearm than in upper arm fistulas. Finally, we showed that the inter-arm difference of AMP correlated with volume flow (r = 0.326 with p = 0.017). CONCLUSION: Pulse waves as assessed by oscillometric pulse wave analysis have distinct features at fistula and non-fistula arms. This is due to enhanced arteriovenous flow, i.e. in both the brachial artery and the fistula vein. The analysis of those alterations has the potential to assess fistula function.


Asunto(s)
Pletismografía , Análisis de la Onda del Pulso , Humanos , Femenino , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Pletismografía/métodos , Análisis de la Onda del Pulso/métodos , Anciano , Diálisis Renal , Oscilometría/métodos , Derivación Arteriovenosa Quirúrgica , Brazo/irrigación sanguínea , Adulto
9.
J Assoc Physicians India ; 72(5): 29-35, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38881107

RESUMEN

BACKGROUND: Spirometry is used extensively, but airway oscillometry is gaining acceptance for evaluating obstructive airway disorders. Moderate persistent asthma requires daily treatment with inhaled corticosteroids (ICS). MATERIALS AND METHODS: We aimed to examine the relationship between airway oscillometry and lung volumes, which are the markers of lung physiology in obstructive airway disease and spirometry in the real-world clinical setting. A total of 72 adults with moderate persistent asthma followed up in our outpatient department from November 2021 to August 2022, and their clinical details and tests of spirometry, forced oscillation technique (FOT), and lung volumes by body plethysmography (BP) performed before and after bronchodilator administration were analyzed. RESULTS: The mean age of the study population was 40 years, and the majority (57%) were females. FOT detected airflow limitation in 12 of the 31 patients with normal spirometry. BP detected abnormalities in more patients than both spirometry and FOT (91.6 vs 73.6%, p < 0.001). Respiratory resistance 5 (R5) had a negative correlation with functional residual capacity (FRC) and total lung capacity (TLC). Reactance 5 (X5) correlated positively with inspiratory capacity (IC) and TLC and negatively with reserve volume (RV)/TLC ratio. A positive correlation was found between IC/TLC% and postbronchodilator X5 and between R5 and 19 and RV/TLC. R5 had a negative and X5 had a positive correlation with forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC), FEV1/FVC, and maximal mid expiratory flow rates (MMEF). ∇X5 had a negative correlation with FEV1, MMEF, and FEV1/FVC. Spirometry detected postbronchodilator responsiveness in more patients than FOT when only the R5 criterion was used and in a comparable number when the X5 criterion was added. ∇X5 and R5-R19/R5 declined significantly after bronchodilators. CONCLUSION: We concluded that there is a moderate correlation between FOT and spirometry and lung volumes by BP. FOT and spirometry should be used together to identify airflow obstruction and postbronchodilator responsiveness in asthma. Lung volumes by BP identify more abnormalities in adults with asthma than both spirometry and FOT. Thresholds to define postbronchodilator responsiveness (PBDR) for ∇X5 and R5-R19 need to be defined.


Asunto(s)
Asma , Pletismografía Total , Espirometría , Humanos , Asma/tratamiento farmacológico , Asma/fisiopatología , Asma/diagnóstico , Femenino , Adulto , Masculino , Espirometría/métodos , Persona de Mediana Edad , Pletismografía Total/métodos , Oscilometría/métodos , Broncodilatadores/uso terapéutico , Broncodilatadores/administración & dosificación , Mediciones del Volumen Pulmonar/métodos , Pulmón/fisiopatología
10.
BMC Pulm Med ; 24(1): 270, 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38844887

RESUMEN

INTRODUCTION: The evaluation of the asthmatic patient is usually based on clinical and functional parameters that do not necessarily evidence the degree of airway inflammation. The aim of this study was to analyze whether clinical scores (CS) correlate with spirometry (S), impulse oscillometry (IO) and FeNO, in severe asthmatic children. MATERIAL AND METHODS: A multicentric, prospective, cross-sectional study was conducted over a 12-month period. All SA patients (6-18 years old) followed-up in the Pulmonology Department were recruited. CS, FeNO measurements, IO and S were consecutively performed on the same day. Asthma control was ascertained using ACT and GINAq. A cut-off value of ≥ 25 parts per billion (ppb) was used to define airway inflammation. RESULTS: Eighty-one patients were included. ACT: 75% (n 61) were controlled; GINAq: 44.5% (n 36) were controlled; 39.5% (n 32) were partly controlled, and 16% (n 13) were uncontrolled. FeNO had a median value of 24 ppb (IQR 14-41); FeNO ≥ 25 ppb was observed in 49% of patients (n 39). ROC AUC for FeNO vs. ACT was 0.71 (95%CI 0.57-0.86), PPV 0.47, NPV 0.87, SE 0.61, SP 0.80; FeNO vs. GINAq was ROC AUC 0.69 (95%CI 0.54-0.85), PPV 0.34, NPV 0.91, SE 0.62, SP 0.77; Youden cut-off FeNO > 39 ppb for both CS. CONCLUSION: In severe asthmatic children, current symptoms control as evidenced by ACT and GINA correlates with low FeNO values. Clinical scores showed good correlation with airway inflammation.


Asunto(s)
Asma , Óxido Nítrico , Oscilometría , Índice de Severidad de la Enfermedad , Espirometría , Humanos , Asma/diagnóstico , Asma/fisiopatología , Niño , Femenino , Masculino , Oscilometría/métodos , Estudios Transversales , Estudios Prospectivos , Adolescente , Óxido Nítrico/análisis , Óxido Nítrico/metabolismo , Curva ROC
11.
Clin Neurol Neurosurg ; 243: 108363, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38878643

RESUMEN

BACKGROUND: Divergence between intra-arterial catheters blood pressure (ABP) and noninvasive oscillometry (NIBP) may affect the care of children with brain arteriovenous malformations (bAVMs). We described the agreement between ABP and NIBP in these children. METHODS: We conducted a retrospective review of patients admitted to the pediatric intensive care unit between 2017 and 2023 with bAVM rupture. Paired ABP and NIBP measurements were collected. Bland-Altman analyses were used to assess agreement. Correlation analysis was conducted between higher ABP and divergence between systolic BP (SBP) measurements. Hypertension was defined as mean arterial pressure (MAP) exceeding age-based 95th percentile. RESULTS: Thirty-four patients with 1901 BP pairs were observed. Bias overall was acceptable, but standard deviation (SD) was high. The best agreement of MAP was in non-hypertensive (bias 1.23 mmHg, SD 8.03 mmHg) and radial arterial catheters (bias 1.83 mmHg, SD 9.08 mmHg) subgroups. Bias for SBP was higher in hypertension (10.98 mmHg) and in infratentorial bAVMs (7.42 mmHg), suggesting poorer agreement in these subgroups. There were significant correlations between intra-arterial MAP and SBP divergence (R = +0.346, p<.001) and between intra-arterial SBP and SBP divergence (R = +0.677, p<.001), suggesting divergence widens with higher BP. Around 25 % of measurement pairs diverged to where one measurement crossed the clinical threshold for treatment, while the other did not, with ABP being more frequently higher than NIBP. CONCLUSIONS: There is good agreement between ABP and NIBP, particularly in non-hypertensive ranges and with radial arterial catheters. Measurements, however, diverge in hypertension. Further research must define age-based thresholds, validate methods of BP measurement, and determine the effect of BP reduction on outcomes in these children.


Asunto(s)
Presión Arterial , Determinación de la Presión Sanguínea , Malformaciones Arteriovenosas Intracraneales , Oscilometría , Humanos , Niño , Malformaciones Arteriovenosas Intracraneales/fisiopatología , Femenino , Masculino , Estudios Retrospectivos , Determinación de la Presión Sanguínea/métodos , Adolescente , Presión Arterial/fisiología , Oscilometría/métodos , Preescolar , Hipertensión/fisiopatología , Presión Sanguínea/fisiología
12.
PLoS One ; 19(5): e0302793, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38739601

RESUMEN

BACKGROUND: In cardiology, cardiac output (CO) is an important parameter for assessing cardiac function. While invasive thermodilution procedures are the gold standard for CO assessment, transthoracic Doppler echocardiography (TTE) has become the established method for routine CO assessment in daily clinical practice. However, a demand persists for non-invasive approaches, including oscillometric pulse wave analysis (PWA), to enhance the accuracy of CO estimation, reduce complications associated with invasive procedures, and facilitate its application in non-intensive care settings. Here, we aimed to compare the TTE and oscillometric PWA algorithm Antares for a non-invasive estimation of CO. METHODS: Non-invasive CO data obtained by two-dimensional TTE were compared with those from an oscillometric blood pressure device (custo med GmbH, Ottobrunn, Germany) using the integrated algorithm Antares (Redwave Medical GmbH, Jena, Germany). In total, 59 patients undergoing elective cardiac catheterization for clinical reasons (71±10 years old, 76% males) were included. Agreement between both CO measures were assessed by Bland-Altman analysis, Student's t-test, and Pearson correlations. RESULTS: The mean difference in CO was 0.04 ± 1.03 l/min (95% confidence interval for the mean difference: -0.23 to 0.30 l/min) for the overall group, with lower and upper limits of agreement at -1.98 and 2.05 l/min, respectively. There was no statistically significant difference in means between both CO measures (P = 0.785). Statistically significant correlations between TTE and Antares CO were observed in the entire cohort (r = 0.705, P<0.001) as well as in female (r = 0.802, P<0.001) and male patients (r = 0.669, P<0.001). CONCLUSIONS: The oscillometric PWA algorithm Antares and established TTE for a non-invasive estimation of CO are highly correlated in male and female patients, with no statistically significant difference between both approaches. Future validation studies of the Antares CO are necessary before a clinical application can be considered.


Asunto(s)
Algoritmos , Gasto Cardíaco , Ecocardiografía Doppler , Análisis de la Onda del Pulso , Humanos , Masculino , Femenino , Gasto Cardíaco/fisiología , Anciano , Análisis de la Onda del Pulso/métodos , Ecocardiografía Doppler/métodos , Persona de Mediana Edad , Anciano de 80 o más Años , Oscilometría/métodos
13.
J Hypertens ; 42(6): 1075-1085, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38690906

RESUMEN

Most non-invasive blood pressure (BP) measurements are carried out using instruments which implement either the Ratio or the Maximum Gradient oscillometric method, mostly during cuff deflation, but more rarely during cuff inflation. Yet, there is little published literature on the relative advantages and accuracy of these two methods. In this study of 40 lightly sedated individuals aged 64.1 ± 9.6 years, we evaluate and compare the performance of the oscillometric ratio (K) and gradient (Grad) methods for the non-invasive estimation of mean pressure, SBP and DBP with reference to invasive intra-arterial values. There was no significant difference between intra-arterial estimates of mean pressure made via Korotkoff sounds (MP-OWE) or the gradient method (MP-Grad). However, 17.7% of MP-OWE and 15% of MP-Grad were in error by more than 10 mmHg. SBP-K and SBP-Grad underestimated SBP by 14 and 18 mmHg, whilst accurately estimating DBP with mean errors of 0.4 ±â€Š5.0 and 1.7 ±â€Š6.1 mmHg, respectively. Relative to the reference standard SBP-K, SBP-Grad and DBP-Grad were estimated with a mean error of -4.5 ±â€Š6.6 and 1.4 ±â€Š5.6 mmHg, respectively, noting that using the full range of recommended ratios introduces errors of 12 and 7 mmHg in SBP and DBP, respectively. We also show that it is possible to find ratios which minimize the root mean square error (RMSE) and the mean error for any particular individual cohort. We developed linear models for estimating SBP and SBP-K from a range of demographic and non-invasive OWE variables with resulting mean errors of 0.15 ±â€Š5.6 and 0.3 ±â€Š5.7 mmHg, acceptable according to the Universal standard.


Asunto(s)
Determinación de la Presión Sanguínea , Presión Sanguínea , Oscilometría , Humanos , Persona de Mediana Edad , Determinación de la Presión Sanguínea/métodos , Masculino , Femenino , Oscilometría/métodos , Anciano , Presión Sanguínea/fisiología
14.
Rev Paul Pediatr ; 42: e2023162, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38808869

RESUMEN

OBJECTIVE: To investigate the effect of bronchodilator on the respiratory mechanics and pulmonary function of children and adolescents with cystic fibrosis. METHODS: Cross-sectional study on clinically stable children and adolescents with cystic fibrosis aged from six to 15 years. Participants underwent impulse oscillometry and spirometry evaluations before and 15 minutes after bronchodilator inhalation. The Kolmogorov-Smirnov test was applied to verify the sample distribution, and the Student's t-test and Wilcoxon test were used to compare the data before and after bronchodilator inhalation. RESULTS: The study included 54 individuals with a mean age of 9.7±2.8 years. The analysis showed a statistically significant improvement in impulse oscillometry and spirometry parameters after bronchodilator inhalation. However, according to the American Thoracic Society (ATS) and European Respiratory Society (ERS) recommendations (2020 and 2021), this improvement was not sufficient to classify it as a bronchodilator response. CONCLUSIONS: The use of bronchodilator medication improved respiratory mechanics and pulmonary function parameters of children and adolescents with cystic fibrosis; however, most patients did not show bronchodilator response according to ATS/ERS recommendations.


Asunto(s)
Broncodilatadores , Fibrosis Quística , Oscilometría , Espirometría , Humanos , Fibrosis Quística/fisiopatología , Fibrosis Quística/tratamiento farmacológico , Niño , Adolescente , Estudios Transversales , Espirometría/métodos , Femenino , Masculino , Oscilometría/métodos , Broncodilatadores/uso terapéutico , Broncodilatadores/administración & dosificación , Mecánica Respiratoria/efectos de los fármacos , Mecánica Respiratoria/fisiología , Pruebas de Función Respiratoria/métodos
15.
J Hypertens ; 42(7): 1235-1247, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38690876

RESUMEN

There is little quantitative clinical data available to support blood pressure measurement accuracy during cuff inflation. In this study of 35 male and 5 female lightly anaesthetized subjects aged 64.1 ±â€Š9.6 years, we evaluate and compare the performance of both the oscillometric ratio and gradient methods during cuff deflation and cuff inflation with reference to intra-arterial measurements. We show that the oscillometric waveform envelopes (OWE), which are key to both methods, exhibit significant variability in both shape and smoothness leading to at least 15% error in the determination of mean pressure (MP). We confirm the observation from our previous studies that K1 Korotkoff sounds underestimate systolic blood pressure (SBP) and note that this underestimation is increased during cuff inflation. The estimation of diastolic blood pressure (DBP) is generally accurate for both the ratio and the gradient method, with the latter showing a significant increase during inflation. Since the gradient method estimates SBP and DBP from points of maximum gradient on each OWE recorded, it may offer significant benefits over the ratio method. However, we have shown that the ratio method can be optimized for any data set to achieve either a minimum mean error (ME) of close to 0 mmHg or minimum root mean square error (RMSE) with standard deviation (SD) of <5.0 mmHg. We conclude that whilst cuff inflation may offer some advantages, these are neither significant nor substantial, leaving as the only benefit, the potential for more rapid measurement and less patient discomfort.


Asunto(s)
Determinación de la Presión Sanguínea , Presión Sanguínea , Oscilometría , Humanos , Masculino , Determinación de la Presión Sanguínea/métodos , Determinación de la Presión Sanguínea/instrumentación , Persona de Mediana Edad , Femenino , Oscilometría/métodos , Anciano , Presión Sanguínea/fisiología
16.
BMC Pediatr ; 24(1): 296, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38702638

RESUMEN

BACKGROUND: Cough variant asthma (CVA) is one of the most common causes of chronic cough in children worldwide. The diagnosis of CVA in children remains challenging. This study aimed to assess the diagnostic utility of impulse oscillometry (IOS) pulmonary function in children with CVA. METHODS: This study included children aged 4 to 12 years diagnosed with CVA who underwent IOS pulmonary function and bronchodilation (BD) tests. A control group of healthy children was matched. Pre- and post-BD IOS parameters were recorded and presented as mean ± standard deviation or median. Receiver operating characteristic (ROC) curves were plotted, and the area under the curve (AUC) was calculated to evaluate the discriminatory potential of the IOS parameters for diagnosing CVA. RESULTS: A total of 180 patients with CVA and 65 control subjects were included. The baseline IOS parameters in the CVA group, except X5%pred, were significantly greater compared to the control group. After inhalation of salbutamol sulfate, all IOS parameters improved significantly in the CVA group. However, Z5%pred, R5%pred, and R20%pred remained greater in the CVA group compared to the control group. The improvement rates of IOS parameters in the CVA group significantly surpassed those in the control group. The ROC curve results for pre-BD IOS parameters and the improvement rate during the BD test showed that the combinations of pre-Z5%pred+△Z5% and pre-R5%pred+△R5% achieved the highest AUC value of 0.920 and 0.898, respectively. The AUC values of these combined parameters surpassed those of individual ones. CONCLUSIONS: This study highlights that children with CVA exhibit greater IOS parameters compared to healthy children. The changes in IOS parameters during the BD test provided valuable diagnostic information for CVA, and the combination of various parameters can help pediatricians accurately identify CVA in children.


Asunto(s)
Asma Variante con Tos , Oscilometría , Niño , Preescolar , Femenino , Humanos , Masculino , Albuterol , Broncodilatadores , Estudios de Casos y Controles , Tos/etiología , Tos/diagnóstico , Asma Variante con Tos/diagnóstico , Asma Variante con Tos/fisiopatología , Oscilometría/métodos , Pruebas de Función Respiratoria/métodos , Curva ROC
17.
IEEE Trans Biomed Eng ; 71(9): 2708-2717, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38625764

RESUMEN

OBJECTIVE: Oscillometric finger pressing is a smartphone-based blood pressure (BP) monitoring method. Finger photoplethysmography (PPG) oscillations and pressure are measured during a steady increase in finger pressure, and an algorithm computes systolic BP (SP) and diastolic BP (DP) from the measurements. The objective was to assess the impact of finger artery viscoelasticity on the BP computation. METHODS: Nonlinear viscoelastic models relating transmural pressure (finger BP - applied pressure) to PPG oscillations during finger pressing were developed. The output of each model to a measured transmural pressure input was fitted to measured PPG oscillations from 15 participants. A parametric sensitivity analysis was performed via model simulations to elucidate the viscoelastic effect on the derivative-based BP computation algorithm. RESULTS: A Wiener viscoelastic model comprising a first-order transfer function followed by a static sigmoidal function fitted the measured PPG oscillations better than an elastic model containing only the static function (median (IQR) error of 30.5% (25.6%-34.0%) vs 50.9% (46.7%-53.7%); p<0.01). In Wiener model simulations, the derivative algorithm underestimated SP, especially with high pulse pressure and low transfer function cutoff frequency (i.e., greater viscoelasticity). The mean of the normalized PPG waveform at the maximum oscillation beat was found to correlate with the cutoff frequency (r = -0.8) and could thus possibly be used to compensate for viscoelasticity. CONCLUSION: Finger artery viscoelasticity negatively impacts oscillometric BP computation algorithms but can potentially be compensated for using available measurements. SIGNIFICANCE: These findings may help in converting smartphones into truly cuffless BP monitors for improving hypertension awareness and control.


Asunto(s)
Arterias , Determinación de la Presión Sanguínea , Dedos , Modelos Cardiovasculares , Fotopletismografía , Teléfono Inteligente , Humanos , Dedos/fisiología , Dedos/irrigación sanguínea , Fotopletismografía/métodos , Masculino , Femenino , Adulto , Determinación de la Presión Sanguínea/métodos , Arterias/fisiología , Algoritmos , Oscilometría/métodos , Elasticidad/fisiología , Adulto Joven , Viscosidad , Procesamiento de Señales Asistido por Computador , Dinámicas no Lineales , Presión Sanguínea/fisiología
18.
Blood Press ; 33(1): 2338208, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38591393

RESUMEN

OBJECTIVE: Some brachial cuffs for oscillometric blood pressure (BP) measurement are claimed to cover a wide range of upper-arm circumferences; however, their validation is rarely conducted. Our aim was to compare oscillometric BP measurements obtained with a universal cuff with those obtained with an appropriately sized cuff. METHODS: We utilised the Microlife B6 Connect monitor, conducting oscillometric BP measurements in a random sequence with both a universal cuff (recommended for arm circumferences from 22 to 42 cm) and an appropriately sized cuff (medium for circumference 22-32 cm and large for 32-42 cm). We included 91 individuals with an arm circumference of 22-32 cm and 64 individuals with an arm circumference of 32-42 cm. RESULTS: For arm circumferences > 32 cm, systolic and diastolic BP measured with the universal cuff was higher than that measured with the large cuff (systolic 6.4 mmHg, 95% confidence interval [CI]). 3.9-8.8, diastolic 2.4 mmHg, 95%CI, 1.2-3.7, p < 0.001 for both). Overestimation of BP with the universal cuff was statistically significant after correcting for the sequence of measurements. No statistical difference was found between the universal cuff and medium cuff for circumferences in the 22-32 cm range. The bladder size in the universal cuff matched the dimensions of the medium-sized cuff; however, the cuff was larger. CONCLUSION: Overestimation of BP measured with a universal cuff in persons with large arm circumferences is clinically important. It poses the risk of unnecessary initiation or intensification of antihypertensive medication in persons using the universal cuff.


What is the context?Clinical guidelines recommend individualisation of the size of the cuff used for blood pressure measurement according to the circumference of the upper arm.Many blood pressure monitors are sold with a single "universal" cuff claimed to cover a wide range of upper arm sizes.We compared blood pressure obtained with the Microlife B6 Connect monitor and a "universal" cuff with the results obtained with individual sized cuffs (medium size for arm circumference between 22 and 32 cm and large size for arm circumference between 32 and 42 cm).What is new?In persons with large upper arm circumference is the systolic blood pressure 6.4 mmHg higher and the diastolic blood pressure 2.4 mmHg higher with the universal cuff than with the individual-sized large cuff.What is the impact?The universal cuff overestimates blood pressure in persons with large arm circumference.


Asunto(s)
Determinación de la Presión Sanguínea , Extremidad Superior , Humanos , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/métodos , Oscilometría/métodos , Diástole , Monitores de Presión Sanguínea
19.
Physiol Meas ; 45(5)2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38599216

RESUMEN

Objective. Diagnosing chronic obstructive pulmonary disease (COPD) using impulse oscillometry (IOS) is challenging due to the high level of clinical expertise it demands from doctors, which limits the clinical application of IOS in screening. The primary aim of this study is to develop a COPD diagnostic model based on machine learning algorithms using IOS test results.Approach. Feature selection was conducted to identify the optimal subset of features from the original feature set, which significantly enhanced the classifier's performance. Additionally, secondary features area of reactance (AX) were derived from the original features based on clinical theory, further enhancing the performance of the classifier. The performance of the model was analyzed and validated using various classifiers and hyperparameter settings to identify the optimal classifier. We collected 528 clinical data examples from the China-Japan Friendship Hospital for training and validating the model.Main results. The proposed model achieved reasonably accurate diagnostic results in the clinical data (accuracy = 0.920, specificity = 0.941, precision = 0.875, recall = 0.875).Significance. The results of this study demonstrate that the proposed classifier model, feature selection method, and derived secondary feature AX provide significant auxiliary support in reducing the requirement for clinical experience in COPD diagnosis using IOS.


Asunto(s)
Aprendizaje Automático , Oscilometría , Enfermedad Pulmonar Obstructiva Crónica , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Humanos , Oscilometría/métodos , Masculino , Femenino , Persona de Mediana Edad , Algoritmos , Anciano
20.
Pediatr Pulmonol ; 59(7): 1885-1893, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38560779

RESUMEN

BACKGROUND: Longitudinal measurements of intrabreath respiratory impedance (Zrs) in preschool-aged children may be able to distinguish abnormal lung function trajectories in children with a history of wheezing compared to healthy ones. METHODS: Children from a prospective, longitudinal community-based cohort performed annual intrabreath oscillometry (IB-OSC) measurements from age 3- to 7-years. IB-OSC was performed using a single 10 Hz sinusoid while clinically asymptomatic. Linear mixed-effects models were developed to explore the effects of wheezing phenotypes, growth, and sex on seven IB-OSC outcome variables over time: resistance at end-expiration (ReE), resistance at end-inspiration (ReI), the tidal change in resistance (∆R=ReE-ReI), reactance at end-expiration (XeE), reactance at end-inspiration (XeI), the tidal change in reactance (∆X=XeE-XeI), and ∆X normalized by tidal volume (∆X/VT). RESULTS: Eighty-five children produced 374 acceptable IB-OSC measurements. Subjects were classified into one of three wheeze groups: never (n = 36), transient (n = 34), or persistent (n = 15). After adjusting for height, children with persistent wheezing, compared to those who never wheezed, had +0.814 hPa s L-1 ReE (95% confidence interval [CI] +0.178 to +1.451, p = 0.015), -0.792 hPa s L-1 XeE (95% CI -1.203 to -0.381, p = 0.003), -0.538 hPa s L-1 ∆X (95% CI -0.834 to -0.242, p = 0.007) and -1.672 hPa s L-2 ∆X/VT (95% CI -2.567 to -0.777, p < 0.001). Increasing height had a significant effect on all IB-OSC resistance and reactance variables when adjusted for the effect of preschool wheezing. CONCLUSIONS: IB-OSC is feasible for tracking lung function growth in preschool-aged children and may allow abnormal lung function to be identified early in asymptomatic preschoolers with a history of persistent wheezing.


Asunto(s)
Ruidos Respiratorios , Humanos , Masculino , Preescolar , Femenino , Estudios Prospectivos , Ruidos Respiratorios/fisiopatología , Estudios Longitudinales , Niño , Oscilometría/métodos , Resistencia de las Vías Respiratorias/fisiología , Pruebas de Función Respiratoria/métodos , Volumen de Ventilación Pulmonar/fisiología