Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97.377
Filtrar
3.
J Biomed Opt ; 29(Suppl 3): S33306, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39247899

RESUMEN

Significance: The arterial input function (AIF) plays a crucial role in correcting the time-dependent concentration of the contrast agent within the arterial system, accounting for variations in agent injection parameters (speed, timing, etc.) across patients. Understanding the significance of the AIF can enhance the accuracy of tissue vascular perfusion assessment through indocyanine green-based dynamic contrast-enhanced fluorescence imaging (DCE-FI). Aim: We evaluate the impact of the AIF on perfusion assessment through DCE-FI. Approach: A total of 144 AIFs were acquired from 110 patients using a pulse dye densitometer. Simulation and patient intraoperative imaging were conducted to validate the significance of AIF for perfusion assessment based on kinetic parameters extracted from fluorescence images before and after AIF correction. The kinetic model accuracy was evaluated by assessing the variability of kinetic parameters using individual AIF versus population-based AIF. Results: Individual AIF can reduce the variability in kinetic parameters, and population-based AIF can potentially replace individual AIF for estimating wash-out rate ( k ep ), maximum intensity ( I max ), ingress slope with lower differences compared with those in estimating blood flow, volume transfer constant ( K trans ), and time to peak. Conclusions: Individual AIF can provide the most accurate perfusion assessment compared with assessment without AIF or based on population-based AIF correction.


Asunto(s)
Verde de Indocianina , Imagen Óptica , Humanos , Imagen Óptica/métodos , Verde de Indocianina/química , Verde de Indocianina/farmacocinética , Femenino , Persona de Mediana Edad , Anciano , Masculino , Medios de Contraste/química , Adulto , Arterias/diagnóstico por imagen , Imagen de Perfusión/métodos , Simulación por Computador
5.
Radiology ; 312(3): e232815, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39254448

RESUMEN

Background Contrast-enhanced US (CEUS) can be used preoperatively for evaluating muscle invasion in bladder cancer, which is important for determining appropriate treatment. However, diagnostic criteria for assessing this at CEUS have not been standardized. Purpose To develop and validate a CEUS Vesical Imaging Reporting and Data System (VI-RADS) for evaluating muscle invasion in bladder cancer. Materials and Methods This single-center prospective study consecutively enrolled patients with suspected bladder cancer. Participants underwent transabdominal or intracavity CEUS between July 2021 and May 2023. Participants were divided into a training set and a validation set at a 2:1 ratio based on the chronologic order of enrollment. The training set was used to identify major imaging features to include in CEUS VI-RADS, and the likelihood of muscle invasion per category was determined using a pathologic reference standard. The optimal VI-RADS category cutoff for muscle invasion was determined with use of the maximum Youden index. The validation set was assessed by novice and expert readers and used to validate the diagnostic performance and interreader agreement of the developed system. Results Overall, 126 participants (median age, 64 years [IQR, 57-71 years]; 107 male) and 67 participants (median age, 64 years [IQR, 56-69 years]; 49 male) were included in the training and validation set, respectively. In the training set, the optimal CEUS VI-RADS category cutoff for muscle invasion was VI-RADS 4 or higher (Youden index, 0.77). In the validation set, CEUS VI-RADS achieved good performance for both novice and expert readers (area under the receiver operating characteristic curve, 0.80 [95% CI: 0.70, 0.90] vs 0.88 [95% CI: 0.80, 0.97]; P = .09). The interreader agreement regarding the evaluation of CEUS VI-RADS category was 0.77 (95% CI: 0.65, 0.85) for novice readers, 0.87 (95% CI: 0.79, 0.92) for expert readers, and 0.78 (95% CI: 0.70, 0.84) for all readers. Conclusion The developed CEUS VI-RADS showed good performance and interreader agreement for the assessment of muscle invasion in bladder cancer. Chinese Clinical Trial Registry no. ChiCTR2100049435 © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Morrell in this issue.


Asunto(s)
Medios de Contraste , Invasividad Neoplásica , Ultrasonografía , Neoplasias de la Vejiga Urinaria , Humanos , Neoplasias de la Vejiga Urinaria/diagnóstico por imagen , Neoplasias de la Vejiga Urinaria/patología , Masculino , Femenino , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Ultrasonografía/métodos , Invasividad Neoplásica/diagnóstico por imagen , Vejiga Urinaria/diagnóstico por imagen , Vejiga Urinaria/patología , Reproducibilidad de los Resultados
7.
ACS Biomater Sci Eng ; 10(9): 5496-5512, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39246058

RESUMEN

Ultrasound (US) is a type of mechanical wave that is capable of transmitting energy through biological tissues. By utilization of various frequencies and intensities, it can elicit specific biological effects. US imaging (USI) technology has been continuously developed with the advantages of safety and the absence of radiation. The advancement of nanotechnology has led to the utilization of various nanomaterials composed of both organic and inorganic compounds as ultrasound contrast agents (UCAs). These UCAs enhance USI, enabling real-time monitoring, diagnosis, and treatment of diseases, thereby facilitating the widespread adoption of UCAs in precision medicine. In this review, we introduce various UCAs based on nanomaterials for USI. Their principles can be roughly divided into the following categories: carrying and transporting gases, endogenous gas production, and the structural characteristics of the nanomaterial itself. Furthermore, the synergistic benefits of US in conjunction with various imaging modalities and their combined application in disease monitoring and diagnosis are introduced. In addition, the challenges and prospects for the development of UCAs are also discussed.


Asunto(s)
Medios de Contraste , Nanoestructuras , Ultrasonografía , Medios de Contraste/química , Humanos , Nanoestructuras/química , Nanoestructuras/uso terapéutico , Ultrasonografía/métodos , Animales
8.
J Plast Surg Hand Surg ; 59: 102-107, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39246152

RESUMEN

PURPOSE: This study aims to investigate whether contrast-enhanced ultrasound (CEUS) could be used to reveal the status of blood supply of the superficial flap of rat model in the early postoperative stage. METHODS: One viable and one ischemic random-pattern flap were prepared on the left and right back of the same rat respectively with a number of 40. CEUS examinations were applied within 12 h and 7 days postoperatively, and the quantitative measurements of microvascular blood volume (BV) of the base and the end of both flaps were expressed using acoustic intensity as a ratio to that of the healthy skin. RESULTS: Within 12 h post operation, there was a smaller BV value of the ischemic ends than that of both the ischemic bases and viable ends (p < 0.001), while no difference was indicated between ischemic bases and viable bases or between viable bases and viable ends. The same result was provided 7 days post operation. CONCLUSION: Microcirculation of superficial tissues such as random-pattern flaps in this rat model can be assessed quantitatively by CEUS. It could sensitively and accurately reveal the objective status of tissue perfusion in the early postoperative stage.


Asunto(s)
Medios de Contraste , Microcirculación , Colgajos Quirúrgicos , Ultrasonografía , Animales , Colgajos Quirúrgicos/irrigación sanguínea , Microcirculación/fisiología , Masculino , Ratas Sprague-Dawley , Ratas , Isquemia/diagnóstico por imagen , Periodo Posoperatorio , Volumen Sanguíneo
9.
Sci Rep ; 14(1): 20758, 2024 09 05.
Artículo en Inglés | MEDLINE | ID: mdl-39237747

RESUMEN

Contrast-enhanced magnetic resonance neurography (CE-MRN) holds promise for diagnosing brachial plexopathy by enhancing nerve visualization and revealing additional imaging features in various lesions. This study aims to validate CE-MRN's efficacy in improving brachial plexus (BP) imaging across different patient cohorts. Seventy-one subjects, including 19 volunteers and 52 patients with BP compression/entrapment, injury, and neoplasms, underwent both CE-MRN and plain MRN. Two radiologists assessed nerve visibility, with inter-reader agreement evaluated. Quantitative parameters such as signal intensity (SI), contrast-to-noise ratio (CNR), and contrast ratio (CR) of the C7 nerve were measured. Both qualitative scoring and quantitative metrics were compared between CE-MRN and plain MRN within each patient group. Patient classification followed the Neuropathy Score Reporting and Data System (NS-RADS), summarizing additional imaging features for each brachial plexopathy type. Inter-reader agreement for qualitative assessment was strong. CE-MRN significantly enhanced BP visualization and nerve-tissue contrast across all cohorts, particularly in volunteers and patients with injuries. It also uncovered additional imaging features such as hypointense signals in ganglia, compressed nerve sites, and neoplastic enhancements. CE-MRN effectively mitigated muscle edema and vascular contamination, enabling precise classification of BP injuries. Overall, CE-MRN consistently enhances BP visualization and provides valuable imaging features for accurate diagnosis.


Asunto(s)
Neuropatías del Plexo Braquial , Plexo Braquial , Medios de Contraste , Imagen por Resonancia Magnética , Humanos , Neuropatías del Plexo Braquial/diagnóstico por imagen , Neuropatías del Plexo Braquial/diagnóstico , Femenino , Masculino , Adulto , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Plexo Braquial/diagnóstico por imagen , Plexo Braquial/patología , Anciano , Adulto Joven
10.
J Nanobiotechnology ; 22(1): 528, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39218888

RESUMEN

Molecular ultrasound imaging with actively targeted microbubbles (MB) proved promising in preclinical studies but its clinical translation is limited. To achieve this, it is essential that the actively targeted MB can be produced with high batch-to-batch reproducibility with a controllable and defined number of binding ligands on the surface. In this regard, poly (n-butyl cyanoacrylate) (PBCA)-based polymeric MB have been used for US molecular imaging, however, ligand coupling was mostly done via hydrolysis and carbodiimide chemistry, which is a multi-step procedure with poor reproducibility and low MB yield. Herein, we developed a single-step coupling procedure resulting in high MB yields with minimal batch-to-batch variation. Actively targeted PBCA-MB were generated using an aminolysis protocol, wherein amine-containing cRGD was added to the MB using lithium methoxide as a catalyst. We confirmed the successful conjugation of cRGD on the MB surface, while preserving their structure and acoustic signal. Compared to the conventional hydrolysis protocol, aminolysis resulted in higher MB yields and better reproducibility of coupling efficiency. Optical imaging revealed that under flow conditions, cRGD- and rhodamine-labelled MB, generated by aminolysis, specifically bind to tumor necrosis factor-alpha (TNF-α) activated endothelial cells in vitro. Furthermore, US molecular imaging demonstrated a markedly higher binding of the cRGD-MB than of control MB in TNF-α activated mouse aortas and 4T1 tumors in mice. Thus, using the aminolysis based conjugation approach, important refinements on the production of cRGD-MB could be achieved that will facilitate the production of clinical-scale formulations with excellent binding and ultrasound imaging performance.


Asunto(s)
Enbucrilato , Microburbujas , Imagen Molecular , Ultrasonografía , Animales , Enbucrilato/química , Ratones , Imagen Molecular/métodos , Ultrasonografía/métodos , Humanos , Medios de Contraste/química , Femenino , Células Endoteliales de la Vena Umbilical Humana , Ratones Endogámicos BALB C , Línea Celular Tumoral , Factor de Necrosis Tumoral alfa/metabolismo
11.
J Diabetes Res ; 2024: 4905669, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39219990

RESUMEN

Background: Deposition of adipose tissue may have a promoting role in the development of diabetic complications. This study is aimed at investigating the relationship between adipose tissue thickness and risk of contrast-induced nephropathy (CIN) in patients with Type 2 diabetes mellitus (T2DM). Methods: A total of 603 T2DM patients undergoing percutaneous coronary angiography or angioplasty with suspicious or confirmed stable coronary artery disease were enrolled in this study. The thicknesses of perirenal fat (PRF), subcutaneous fat (SCF), intraperitoneal fat (IPF), and epicardial fat (ECF) were measured by color Doppler ultrasound, respectively. The association of various adipose tissues with CIN was analyzed. Results: Seventy-seven patients (12.8%) developed CIN in this cohort. Patients who developed CIN had significantly thicker PRF (13.7 ± 4.0 mm vs. 8.9 ± 3.6 mm, p < 0.001), slightly thicker IPF (p = 0.046), and similar thicknesses of SCF (p = 0.782) and ECF (p = 0.749) compared to those who did not develop CIN. Correlation analysis showed that only PRF was positively associated with postoperation maximal serum creatinine (sCr) (r = 0.18, p = 0.012), maximal absolute change in sCr (r = 0.33, p < 0.001), and maximal percentage of change in sCr (r = 0.36, p < 0.001). In receiver operating characteristic (ROC) analysis, the area under the curve (AUC) of PRF (0.809) for CIN was significantly higher than those of SCF (0.490), IPF (0.594), and ECF (0.512). Multivariate logistic regression analysis further confirmed that thickness of PRF, rather than other adipose tissues, was independently associated with the development of CIN after adjusted for confounding factors (odds ratio (OR) = 1.53, 95% CI: 1.38-1.71, p < 0.001). Conclusions: PRF is independently associated with the development of CIN in T2DM patients undergoing coronary catheterization.


Asunto(s)
Medios de Contraste , Angiografía Coronaria , Diabetes Mellitus Tipo 2 , Nefropatías Diabéticas , Humanos , Diabetes Mellitus Tipo 2/complicaciones , Femenino , Masculino , Medios de Contraste/efectos adversos , Persona de Mediana Edad , Anciano , Angiografía Coronaria/efectos adversos , Factores de Riesgo , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tejido Adiposo/diagnóstico por imagen , Tejido Adiposo/patología , Enfermedades Renales/inducido químicamente , Grasa Intraabdominal/diagnóstico por imagen , Cateterismo Cardíaco/efectos adversos , Creatinina/sangre
13.
Ultrasound Q ; 40(4)2024 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-39282951

RESUMEN

ABSTRACT: We aimed to measure cerebral, splanchnic, and renal transit times and the associated blood volumes using contrast ultrasound. In healthy individuals, regional transit times were calculated from time-intensity curves generated as ultrasound contrast passed through the associated inflow and outflow vessels. These included the internal carotid artery and internal jugular vein (brain), the superior mesenteric artery and portal vein (intestines), and the renal artery and renal vein (kidney). An organ's blood volume relative to the stroke volume delivered to that organ with each cardiac cycle was calculated from the product of heart rate and transit time of contrast passage through the associated vascular bed. The fraction of systemic stroke volume received by each organ was calculated from the respective velocity-time integral and inflow vessel cross-sectional area and used to estimate absolute organ blood volume. The cohort consisted of 16 participants (age: 42 ± 13 years; 5 female) without known cerebrovascular, gastrointestinal, or renal disease. Cerebral, splanchnic, and renal transit times were obtained for 15, 14, and 8 individuals, respectively. Anatomic variability of the renal vessels confounded the acquisition of renal transit times. For all organs, transit times were reproducible and the associated blood volumes were generally comparable to reference values. Cerebral, gastrointestinal, and renal transit times/blood volumes can be reasonably acquired from contrast ultrasound, although the latter is less reliably available. Assessment of the impact on regional blood volumes of pharmacologic or other interventions is a next step toward clinical application of this technique.


Asunto(s)
Volumen Sanguíneo , Medios de Contraste , Circulación Esplácnica , Ultrasonografía , Humanos , Femenino , Masculino , Adulto , Ultrasonografía/métodos , Volumen Sanguíneo/fisiología , Circulación Esplácnica/fisiología , Riñón/diagnóstico por imagen , Riñón/irrigación sanguínea , Circulación Cerebrovascular/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Encéfalo/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Persona de Mediana Edad , Reproducibilidad de los Resultados , Aumento de la Imagen/métodos , Determinación del Volumen Sanguíneo/métodos , Circulación Renal/fisiología
14.
Redox Rep ; 29(1): 2398380, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-39284588

RESUMEN

Purpose: To investigate the renal pathophysiological processes and protective effect of quercetin on contrast-induced acute kidney injury (CI-AKI) in mice with type 1 diabetic mellitus(DM) using diffusion tensor imaging(DTI).Methods: Mice with DM were divided into two groups. In the diabetic + contrast medium(DCA) group, the changes of the mice kidneys were monitored at 1, 24, 48, and 72 h after the injection of iodixanol(4gI/kg). The mice in the diabetic + contrast medium + quercetin(DCA + QE) group were orally given different concentrations of quercetin for seven days before injection of iodixanol. In vitro experiments, renal tubular epithelial (HK-2) cells exposed to high glucose conditions were treated with various quercetin concentrations before treatment with iodixanol(250 mgI/mL).Results: DTI-derived mean diffusivity(MD) and fractional anisotropy(FA) values can be used to evaluate CI-AKI effectively. Quercetin significantly increased the expression of Sirt 1 and reduced oxidative stress by increasing Nrf 2/HO-1/SOD1. The antiapoptotic effect of quercetin on CI-AKI was revealed by decreasing proteins level and by reducing the number of apoptosis-positive cells. In addition, flow cytometry indicated quercetin-mediated inhibition of M1 macrophage polarization in the CI-AKI.Conclusions: DTI will be an effective noninvasive tool in diagnosing CI-AKI. Quercetin attenuates CI-AKI on the basis of DM through anti-oxidative stress, apoptosis, and inflammation.


Asunto(s)
Lesión Renal Aguda , Medios de Contraste , Diabetes Mellitus Tipo 1 , Imagen de Difusión Tensora , Quercetina , Animales , Quercetina/farmacología , Quercetina/uso terapéutico , Ratones , Lesión Renal Aguda/inducido químicamente , Lesión Renal Aguda/tratamiento farmacológico , Lesión Renal Aguda/metabolismo , Lesión Renal Aguda/diagnóstico por imagen , Medios de Contraste/efectos adversos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/complicaciones , Masculino , Estrés Oxidativo/efectos de los fármacos , Diabetes Mellitus Experimental/tratamiento farmacológico , Diabetes Mellitus Experimental/complicaciones , Riñón/efectos de los fármacos , Apoptosis/efectos de los fármacos , Ácidos Triyodobenzoicos
15.
Int J Nanomedicine ; 19: 9213-9226, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39263631

RESUMEN

Introduction: Targeting, imaging, and treating tumors represent major clinical challenges. Developing effective theranostic agents to address these issues is an urgent need. Methods: We introduce an "all-in-one" tumor-targeted theranostic platform using CuFeSe2-based composite nanoparticles (CuFeSe2@PA) for magnetic resonance (MR) and computed tomography (CT) dual model imaging-guided hyperthermia tumor ablation. Plerixafor (AMD3100) is bonded to the surface of CuFeSe2 as a targeting unit. Due to the robust interaction between AMD3100 and the overexpressed Chemokine CXC type receptor 4 (CXCR4) on the membrane of 4T1 cancer cells, CuFeSe2@PA specifically recognizes 4T1 cancer cells, enriching the tumor region. Results: CuFeSe2@PA serves as a contrast agent for T2-weighted MR imaging (relaxivity value of 1.61 mM-1 s-1) and CT imaging. Moreover, it effectively suppresses tumor growth through photothermal therapy (PTT) owing to its high photothermal conversion capability and stability, with minimized side effects demonstrated both in vitro and in vivo. Discussion: CuFeSe2@PA nanoparticles show potential as dual-mode imaging contrast agents for MR and CT and provide an effective means of tumor treatment through photothermal therapy. The surface modification with Plerixafor enhances the targeting ability of the nanoparticles, performing more significant efficacy and biocompatibility in the 4T1 cancer cell model. The study demonstrates that CuFeSe2@PA is a promising multifunctional theranostic platform with clinical application potential.


Asunto(s)
Cobre , Imagen por Resonancia Magnética , Terapia Fototérmica , Receptores CXCR4 , Nanomedicina Teranóstica , Tomografía Computarizada por Rayos X , Animales , Receptores CXCR4/metabolismo , Nanomedicina Teranóstica/métodos , Terapia Fototérmica/métodos , Línea Celular Tumoral , Imagen por Resonancia Magnética/métodos , Ratones , Cobre/química , Compuestos Heterocíclicos/química , Compuestos Heterocíclicos/farmacología , Ratones Endogámicos BALB C , Femenino , Humanos , Medios de Contraste/química , Nanopartículas/química , Ciclamas/farmacología , Ciclamas/química , Bencilaminas/química
16.
Theranostics ; 14(13): 5022-5101, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39267777

RESUMEN

The potential of intranasal administered imaging agents to altogether bypass the blood-brain barrier offers a promising non-invasive approach for delivery directly to the brain. This review provides a comprehensive analysis of the advancements and challenges of delivering neuroimaging agents to the brain by way of the intranasal route, focusing on the various imaging modalities and their applications in central nervous system diagnostics and therapeutics. The various imaging modalities provide distinct insights into the pharmacokinetics, biodistribution, and specific interactions of imaging agents within the brain, facilitated by the use of tailored tracers and contrast agents. Methods: A comprehensive literature search spanned PubMed, Scopus, Embase, and Web of Science, covering publications from 1989 to 2024 inclusive. Starting with advancements in tracer development, we going to explore the rationale for integration of imaging techniques, and the critical role novel formulations such as nanoparticles, nano- and micro-emulsions in enhancing imaging agent delivery and visualisation. Results: The review highlights the use of innovative formulations in improving intranasal administration of neuroimaging agents, showcasing their ability to navigate the complex anatomical and physiological barriers of the nose-to-brain pathway. Various imaging techniques, MRI, PET, SPECT, CT, FUS and OI, were evaluated for their effectiveness in tracking these agents. The findings indicate significant improvements in brain targeting efficiency, rapid uptake, and sustained brain presence using innovative formulations. Conclusion: Future directions involve the development of optimised tracers tailored for intranasal administration, the potential of multimodal imaging approaches, and the implications of these advancements for diagnosing and treating neurological disorders.


Asunto(s)
Administración Intranasal , Encéfalo , Humanos , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Animales , Medios de Contraste/administración & dosificación , Medios de Contraste/farmacocinética , Neuroimagen/métodos , Sistemas de Liberación de Medicamentos/métodos , Barrera Hematoencefálica/metabolismo , Barrera Hematoencefálica/diagnóstico por imagen , Nanopartículas/química , Nanopartículas/administración & dosificación , Distribución Tisular , Imagen por Resonancia Magnética/métodos
17.
Fluids Barriers CNS ; 21(1): 72, 2024 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-39285434

RESUMEN

BACKGROUND: Pathways for intravenously administered gadolinium-based-contrast-agents (GBCAs) entering cerebrospinal-fluid (CSF) circulation in the human brain are not well-understood. The blood-CSF-barrier (BCSFB) in choroid-plexus (CP) has long been hypothesized to be a main entry-point for intravenous-GBCAs into CSF. Most existing studies on this topic were performed in animals and human patients with various diseases. Results in healthy human subjects are limited. Besides, most studies were performed using MRI methods with limited temporal resolution and significant partial-volume effects from blood and CSF. METHODS: This study employs the recently developed dynamic-susceptibility-contrast-in-the-CSF (cDSC) MRI approach to measure GBCA-distribution in the CSF immediately and 4 h after intravenous-GBCA administration in healthy subjects. With a temporal resolution of 10 s, cDSC MRI can track GBCA-induced CSF signal changes during the bolus phase, which has not been investigated previously. It employs a long echo-time (TE = 1347 ms) to suppress tissue and blood signals so that pure CSF signal is detected with minimal partial-volume effects. GBCA concentration in the CSF can be estimated from cDSC MRI. In this study, cDSC and FLAIR MRI were performed immediately and 4 h after intravenous GBCA administration in 25 healthy volunteers (age 48.9 ± 19.5 years; 14 females). Paired t-tests were used to compare pre-GBCA and post-GBCA signal changes, and their correlations with age were evaluated using Pearson-correlation-coefficients. RESULTS: At ~ 20 s post-GBCA, GBCA-induced cDSC signal changes were detected in the CSF around CP (ΔS/S = - 2.40 ± 0.30%; P < .001) but not in the rest of lateral ventricle (LV). At 4 h, significant GBCA-induced cDSC signal changes were observed in the entire LV (ΔS/S = - 7.58 ± 3.90%; P = .002). FLAIR MRI showed a similar trend. GBCA-induced CSF signal changes did not correlate with age. CONCLUSIONS: These results provided direct imaging evidence that GBCAs can pass the BCSFB in the CP and enter ventricular CSF immediately after intravenous administration in healthy human brains. Besides, our results in healthy subjects established a basis for clinical studies in brain diseases exploiting GBCA-enhanced MRI to detect BCSFB dysfunction.


Asunto(s)
Plexo Coroideo , Medios de Contraste , Imagen por Resonancia Magnética , Humanos , Medios de Contraste/administración & dosificación , Plexo Coroideo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Masculino , Adulto , Femenino , Gadolinio/administración & dosificación , Persona de Mediana Edad , Voluntarios Sanos , Adulto Joven , Administración Intravenosa
18.
BMC Urol ; 24(1): 189, 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39218886

RESUMEN

OBJECTIVE: Contrast-enhanced computed tomography (CECT) improves lesion contrast with surrounding tissues through the injection of contrast agents. This enhancement allows for more precise lesion characterization, aiding in the early diagnosis of clear cell renal cell carcinoma (ccRCC). This meta-analysis aims to assess the diagnostic efficacy of CECT in ccRCC and to provide an ideal imaging examination method for the preoperative diagnosis of ccRCC. METHODS: We conducted a comprehensive search across six major online databases: PubMed, Web of Science, Cochrane Library, WANFANG DATA, China National Knowledge Infrastructure, and Chinese BioMedical Literature Database (CBM). The objective was to collate and analyze studies that evaluate the diagnostic utility of CECT in the identification of ccRCC. Meta-disc 1.4 and Stata 16.0 were used to conduct a meta-analysis and evaluate the diagnostic accuracy of CECT for ccRCC. RESULTS: The meta-analysis included 17 relevant studies investigating the diagnostic value of CECT for ccRCC. The combined sensitivity and specificity of CECT were 0.88 (95% confidence interval: 0.83-0.91) and 0.82 (95%CI: 0.75-0.87), respectively. Positive diagnostic likelihood ratio = 4.87 (95%CI: 3.47-6.84), negative diagnostic likelihood ratio = 0.15 (95%CI: 0.11-0.21), and diagnostic odds ratio = 32.67 (95%CI: 18.21-58.61). In addition, the area under the ROC curve was 0.92 (95%CI: 0.89-0.94), indicating that CECT has a decent discriminative ability in diagnosing ccRCC. CONCLUSIONS: CECT is recognized as a highly effective imaging tool for diagnosing ccRCC. It provides valuable guidance in the preoperative assessment and planning of surgical strategies for patients with ccRCC.


Asunto(s)
Carcinoma de Células Renales , Medios de Contraste , Neoplasias Renales , Tomografía Computarizada por Rayos X , Humanos , Carcinoma de Células Renales/diagnóstico por imagen , Neoplasias Renales/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
19.
Wiad Lek ; 77(8): 1525-1532, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39231323

RESUMEN

OBJECTIVE: Aim: To assess the initial results of using 3 Tesla contrast-enhanced breast magnetic resonance imaging in Ukraine. PATIENTS AND METHODS: Materials and Methods: Our study included 498 diagnostic breast magnetic resonance imaging performed in Neuromed medical center in Kyiv, between March 2020 and December 2022. Patients were positioned prone, with breasts suspended in a dedicated 7-channel bilateral breast coil. MR-images were acquired with the PHILIPS Achieva 3.0Tesla x-series scanner. All studies were made by standard protocol: localizer, morphological and dynamic studies were performed. RESULTS: Results: Our study revealed a statistically significant increase in problem-solving contrast-enhanced breast magnetic resonance examinations compared to other indications. Additionally, we observed a higher incidence of women with a greater amount of fibroglandular tissue (p-value<0.05). CONCLUSION: Conclusions: The utilization of 3Tesla contrast-enhanced breast magnetic resonance imaging has become prevalent in Ukraine as a problem-solving tool for inconclusive findings in ultrasound (US) or/and mammography (MG). It is particularly useful in preoperative local breast cancer staging for women with a significant amount of fibroglandular breast tissue. However, the implementation of breast magnetic resonance imaging in Ukraine is in its nascent stages and requires further investigation, especially in middle-income country settings.


Asunto(s)
Neoplasias de la Mama , Imagen por Resonancia Magnética , Humanos , Femenino , Ucrania , Adulto , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico , Persona de Mediana Edad , Mama/diagnóstico por imagen , Mama/patología , Anciano , Medios de Contraste
20.
BMJ Open ; 14(9): e069788, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39231551

RESUMEN

OBJECTIVE: The objective is to evaluate the diagnostic effectiveness of contrast-enhanced spectral mammography (CESM) in the diagnosis of breast cancer. DESIGN: DATA SOURCES: PubMed, Embase and Cochrane libraries up to 18 June 2022. ELIGIBILITY CRITERIA FOR SELECTING STUDIES: We included trials studies, compared the results of different researchers on CESM in the diagnosis of breast cancer, and calculated the diagnostic value of CESM for breast cancer. DATA EXTRACTION AND SYNTHESIS: Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) evaluated the methodological quality of all the included studies. The study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses specification. In addition to sensitivity and specificity, other important parameters were explored in an analysis of CESM accuracy for breast cancer diagnosis. For overall accuracy estimation, summary receiver operating characteristic curves were calculated. STATA V.14.0 was used for all analyses. RESULTS: This meta-analysis included a total of 12 studies. According to the summary estimates for CESM in the diagnosis of breast cancer, the pooled sensitivity and specificity were 0.97 (95% CI 0.92 to 0.98) and 0.76 (95% CI 0.64 to 0.85), respectively. Positive likelihood ratio was 4.03 (95% CI 2.65 to 6.11), negative likelihood ratio was 0.05 (95% CI 0.02 to 0.09) and the diagnostic odds ratio was 89.49 (95% CI 45.78 to 174.92). Moreover, there was a 0.95 area under the curve. CONCLUSIONS: The CESM has high sensitivity and good specificity when it comes to evaluating breast cancer, particularly in women with dense breasts. Thus, provide more information for clinical diagnosis and treatment.


Asunto(s)
Neoplasias de la Mama , Medios de Contraste , Mamografía , Sensibilidad y Especificidad , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico , Mamografía/métodos , Femenino , Curva ROC
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA